Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹2.0 L+₹4,511 (2.28%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | HARMUKH INFRASTRUCTURE PRIVATE LIMITED L1 | MANNAN ELECTRICALS L2 |
|---|---|---|---|---|---|
| 1.01 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles with pit excavation [IS 2713 410 SP 33] | 2 | Nos | 41,998 ₹41,998 | 33,000 ₹33,000 Lowest |
| 1.02 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles with pit excavation [IS 2713 410 SP 15] | 2 | Nos | 31,998 ₹31,998 | 30,000 ₹30,000 Lowest |
| 1.03 | Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and Laying of 0.05 ACSR Conductor | 0.3 | KM | 17,400 ₹17,400 | 16,500 ₹16,500 Lowest |
| 1.04 | Supply,installation, testing and commissioning of Gapless Surge Arrestor, 9kV, 10KA LA with polymer housing, station type. | 1 | Set | 5,999 ₹5,999 | 5,100 ₹5,100 Lowest |
| 1.05 | Supply,installation, testing and commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A | 1 | Set | 5,999 ₹5,999 | 2,400 ₹2,400 Lowest |
| 1.06 | Supply,installation, testing and commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole,200 Amp, Vertical Type | 1 | Set | 15,999 ₹15,999 | 6,500 ₹6,500 Lowest |
| 1.07 | Providing & fixing of GI Channel cross-arm (100 x 50x6mm) / 75x40x40 x6mm including back clamps of 50X8 mm for fixing Cross arm and pole top bracket, Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing Cross arm and pole top bracket . . | 240 | Kgs | 38,400 ₹38,400 Lowest | 40,800 ₹40,800 |
| 1.08 | Supply,installation, testing and commissioning of 11 KV Polymeric Composit pin with insulator insulator 12 KV, 5 KN,Light Impulse 75 KVPositive and 80 KV Negative ,Creepage distance 320 mm | 3 | Nos | 897 ₹897 Lowest | 1,050 ₹1,050 |
| 1.09 | Supply,installation, testing and commissioning of 11 KV Polymeric Disc Insulator with insulator insulator 12 KV, 5 KN,Light Impulse 75 KVPositive and 80 KV Negative ,Creepage distance 320 mm | 1 | Nos | 599 ₹599 | 320 ₹320 Lowest |
| 1.10 | Providing & Painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) | 4 | Nos | 1,996 ₹1,996 | 1,400 ₹1,400 Lowest |
Tender Value
₹2.0 L
EMD Value
₹4,100
Closing Date
29 Sept 2025, 4:00 pmClosed
Ex Engineer ED Ganderbal
Office of the Ex Engineer ED Ganderbal
Shifting of 250 KVA Sayeed Basti Transformer at Surfraw-B under DDC Grants
2025_PDD_286767_1
EDG/V/064 OF 2025-26
Open Tender
Electrical Works
Lump-sum
20 days
GANDERBAL
Please refer Tender documents.
5 documents required · 5 mandatory
₹200
Ex Engineer ED Ganderbal
₹4,100
3 Oct 2025
3 Sept 2025
30 Sept 2025
3 Sept 2025
29 Sept 2025
3 Sept 2025
3 Sept 2025 - 4 Sept 2025
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles with pit excavation [IS 2713 410 SP 33]
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles with pit excavation [IS 2713 410 SP 15]
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and Laying of 0.05 ACSR Conductor
Supply,installation, testing and commissioning of Gapless Surge Arrestor, 9kV, 10KA LA with polymer housing, station type.
Supply,installation, testing and commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply,installation, testing and commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole,200 Amp, Vertical Type
Providing & fixing of GI Channel cross-arm (100 x 50x6mm) / 75x40x40 x6mm including back clamps of 50X8 mm for fixing Cross arm and pole top bracket, Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing Cross arm and pole top bracket . .
Supply,installation, testing and commissioning of 11 KV Polymeric Composit pin with insulator insulator 12 KV, 5 KN,Light Impulse 75 KVPositive and 80 KV Negative ,Creepage distance 320 mm
Supply,installation, testing and commissioning of 11 KV Polymeric Disc Insulator with insulator insulator 12 KV, 5 KN,Light Impulse 75 KVPositive and 80 KV Negative ,Creepage distance 320 mm
Providing & Painting of each Pole 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
Supply,installation, testing and commissioning of Galvanized Nuts and Bolts of sizes.
Providing & Laying of Cement bottoming 1:2:4 mix as per Standards 0.40 cum per pole for ( 8 Mtr)
Providing & Laying of Cement bottoming 1:2:4 mix as per Standards 0.45 cum per pole for ( 9 Mtr)
Providing & fixing of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm
Providing & Laying of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm No.minal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover
Providing and fixing of GI Wire
Supply,installation, testing and commissioning of LT Fuse Set
Supply,installation, testing and commissioning of 16 KN Polymer Shackle Insulators LT
Supply,installation, testing and commissioning of GI Mukey for Shackle Insulator with Bolt of (50x6)mm
Supply,installation, testing and commissioning of GI Barbed Wire for Anticlimbing
Supply,installation, testing and commissioning of Anticlimbing Device with clamps
Dismentalling and Reinstallation of 250 KVA Distribution Transformer
Providing of Stencil and Spray Painting (Black in Colour) on each Pole at an height of 4.5 feet above ground levelwith following specification: 1.The Dimension of the Stensil should be not less than 21"x9" per pole. 2.The following details are to be recorded on each pole with the Spray paint. a). Name of the Work b)Year c). name of the Contractor d). SR of the pole The said Stensil should be approved by EDV Ganderbal
Pre and post Geo tagged photographic Evidence consisting of 5x7 inch Photographs in coffee table book and autocad single line diagram
MANNAN ELECTRICALS (BID ID -2535769)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .