Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC TAIDU P O P S TAIDU GOMATI DISTRICT TRIPURA 799101 | TAIDU | GOMATI | TRIPURA | 799101 | ₹10.9 L | L1 | Accepted-AOC The bidder is Technically and Financially responsive being L1. |
| 2 | L2₹11.5 LRejected-AOC | ₹11.5 L | L2 | Rejected-AOC The bidder is Technically and Financially responsive. |
Tender Value
₹11.0 L
EMD Value
₹21,906
Closing Date
25 Feb 2026, 3:00 pmClosed
Executive Engineer, DWS Division, Amarpur,
O/O The Executive Engineer, DWS Division, Amarpur,
Improvement and widening AT road to kaifung Para PMGSY road to Sadhu Para ( L407)(Length-0.62),2.No Regrouping Colony to Ompi Raban Para PMGSY Road ( L402) (Length-0.771),Regrouping colony to Ompi Raban PMGSY road ( L401) (Length-0.793 km) under
2026_CEDWS_70551_1
82/DNIeT/EE/DWS/AMP/2025-26
Open Tender
Civil Works - Water Works
60 days
Ampi
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
₹21,906
24 Mar 2026
18 Feb 2026
25 Feb 2026
18 Feb 2026
25 Feb 2026
18 Feb 2026
18 Feb 2026 - 25 Feb 2026
Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cement conforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. A. Class - 3 ( working pressure 6.0 kg / cm2) i) 40mm OD
iii) 90mm OD
iv)110mm OD
Providing, fixing and laying fabricated UPVC bend of required degree conforming to IS : 10124 ( part 8 / 9 / 10 / 11 / 12 / 13 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. iii) 90 mm dia
iv) 110 mm dia
Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. iii) 90 mm dia
Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. iii) 100 x 100 mm dia
Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. ii) 110 x 90 mm dia
Providing, fixing and laying flanged fabricated UPVC tailpiece with MS flange ( 8 mm thick ) conforming to IS : 10124 ( Part6 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. i) 90 mm dia
ii) 110 mm dia
Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. i) 80 mm dia. A. PN - 1.0
ii) 100 mm dia. A. PN - 1.0
Providing and fixing GI pipes of medium class as per IS: 1239 with latest amendment complete with GI fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specifications and direction of the Engineer-in-charge. A. External work ii) 40 mm dia nominal bore
Providing and laying of flexible PVC pipe (conforming to IS:7634) complete including earth work as per specification and direction of the Engineer - in - charge (cost of fittings will be paid separately). i) 15 mm dia
Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm (slope-1 in 200)including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge. A) For UPVC pipes in new work. a. In all kind of Soils i) For pipes not exceeding 90 mm dia
ii) For pipes exceeding 90mm dia but not exceeding 300mm dia.
Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. 1) 15 mm dia
Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer - in - charge. i) 15 mm dia
i) 40 mm dia
Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge. i) 15 mm dia
i) 40 mm dia
Providing & fitting fixing of G.I. flange ( 10 mm wall thickness ) by welding with G.I. / MS pipe and placing position as per specification and the direction of the Engineer-in-charge. ii) 80 mm dia
Making road crossing by horizontal boring for smooth laying of UPVC/CI/DI/GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge. A. By manual means
Charges for dismantling PVC/ HDPE pipe after necessary excavation of earth including washing stacking of pipes properly at site with leads and lifts and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming,watering etc complete as per specification & direction of the engineer- in - charge. i) 90 mm dia
ii) 100 mm dia
Constructing masonry Chamber 90 x 90 x 100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160mm bottom diameter and 190 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design: A. With Second Class bricks.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_71797.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.56 MB
FDNIeT82.pdf
Tender Documents • 4.03 MB
BOQ_71797.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid