Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹35.4 L+₹1.8 L (5.33%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L2 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
6 Sept 2021, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2021_MES_467099_1
GE MAINT EZHIMALA 8402
Open Tender
Civil Works
Item Rate
270 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹80,000
Yes
20 Sept 2021
11 Aug 2021
8 Sept 2021
11 Aug 2021
6 Sept 2021
25 Aug 2021
12 Aug 2021 - 19 Aug 2021
Amount
Repair/replacement old U/s LT panel board with out door type double door floor mounted free standing dust and vermin proof panel with IP-65 protection fabricated out of 3.15mm thick CRCA sheet of size 1.2m x 1.2 m x 0.6 m duly pretreated in seven tank proces for degreasing ,de-rusting and phosphated primer powder coated then painted with final coat of epoxy based powder coated panel shall be having front and rear opening for installation of seperate cable alleys with proper locking arrangement with busbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended busbar links/terminals to be provided for heat dissipation. Suitable size knockout holes for cable glands shall be provided.Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items.The panel shall be duly supported on angle iron of size 40x40x4mm thick and panel shall include the following accessories:-
(a) Busbar chamber (4 nos TP&N 400 amp rating) (Aluminium bus bar) SET 01 (with proper colour code). (b) Phase indicator LED lamp assembly- 03 No. (c) Complete wiring of panel with suitable gauge multi stranded copper conductor with proper colour code. (d) Digital multi functional meter to measure current,voltage,power factor etc-01 , with connected CT's of suitable size. Panel should have separate chambers and busbar extensions to accomodate the following switch gears:- i) MCCB TPN 250 A as incomer - 01 No ii)outgoing MCCB 160 A - 02 Nos iii)MCB TPN 63 A -10 Nos iv) Contactor MCX12, 4 pole,415 volts, 63 Amps - 01 No (v) Digital time switch day/weeks programme with reserve 30 minutes- 01 No Notes:- (a) Existing serviceable switch gears obtained from old panel board will be reused and new switch gears replaced will be measured and paid separetly. (b) Panels shall be procured from firms having CPRI approval certificate. (c) Quoted rate is deemed to be inclusive of necessary earthwork & PCC.
Repair/replacement old U/s LT panel board with out door type double door floor mounted free standing dust and vermin proof panel with IP-65 protection fabricated out of 3.15mm thick CRCA sheet of size 1.5m x 1.2 m x 0.6 m duly pretreated in seven tank proces for degreasing ,de-rusting and phosphated primer powder coated then painted with final coat of epoxy based powder coated. panel shall be having front and rear opening for installation of seperate cable alleys with proper locking arrangement with busbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended busbar links/terminals to be provided for heat dissipation. Suitable size knockout holes for cable glands shall be provided.Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items.The panel shall be duly supported on angle iron of size 40x40x4mm thick and panel shall include following accessories:-
(a) Busbar chamber (4 nos TP&N 630 amp rating) (Aluminium bus bar) SET 01 (with proper colour code) (b) Phase indicator LED lamp assembly - 03 No (c) Complete wiring of panel with suitable gauge multi stranded copper conductor with proper colour code. (d) Digital multi functional meter to measure current,voltage,power factor etc-01 , with connected CT's of suitable size. Panel should have separate chambers and busbar extensions to accomodate following switch gears:- i) MCCB TPN 400 A as incomer - 01 No ii) Outgoing MCCB 250 A - 03 Nos iii) Outgoing MCCB 160 A - 01 Nos iii) MCB TPN 63 A - 6 Nos iv) Contactor MCX12, 4 pole,415 volts, 63 Amps - 01 No (v) Digital time switch day/weeks programme with reserve 30 minutes - 01 No Note:- a) Existing serviceable switch gears obtained from old panel board will be reused and new switch gears replaced will be measured and paid separately. b) Panels shall be procured from firms having CPRI approval certificate. (c) Quoted rate is deemed to be inclusive of necessary earthwork & PCC.
Repair/replacement old U/s LT panel board with out door type double door floor mounted free standing dust and vermin proof panel with IP-65 protection fabricated out of 3.15mm thick CRCA sheet of size 1m x 1m x 0.6m duly pretreated in seven tank proces for degreasing ,de-rusting and phosphated primer powder coated then painted with final coat of epoxy based powder coated. panel shall be having front and rear opening for installation of seperate cable alleys with proper locking arrangement with busbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended busbar links/terminals to be provided for heat dissipation. Suitable size knockout holes for cable glands shall be provided.Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items.The panel shall be duly supported on angle iron of size 40x40x4mm thick and panel shall include the following accessories:-
(a) Busbar chamber (4 nos TP&N 630 amp rating)(Aluminium bus bar) SET 01 (with proper colour code ) (b) Phase indicator LED lamp assembly - 03 No (c) Complete wiring of panel with suitable gauge multi stranded copper conductor with proper colour code. (d) Digital multi functional meter to measure current,voltage,power factor etc-01 , with connected CT's of suitable size. Panel should have separate chambers and busbar extensions to accomodate following switch gears:- i) MCCB TPN 630 A as incomer - 01 No ii) Outgoing MCCB 250 A - 03 Nos iii) Outgoing MCCB 160 A - 01 Nos Note:- a) Existing serviceable switch gears obtained from old panel board will be reused and new switch gears replaced will be measured and paid separetly. b) Panels shall be procured from firms having CPRI approval certificate. (c) Quoted rate is deemed to be inclusive of necessary earthwork & PCC.
Repair/ replacement old U/s LT panel board with out door type double door floor mounted free standing dust and vermin proof panel with IP-65 protection fabricated out of 3.15mm thick CRCA sheet of size 1 m x 1.2 m x 0.6m duly pretreated in seven tank proces for degreasing ,de-rusting and phosphated primer powder coated then painted with final coat of epoxy based powder coated. panel shall be having front and rear opening for installation of seperate cable alleys with proper locking arrangement with busbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended busbar links/terminals to be provided for heat dissipation. Suitable size knockout holes for cable glands shall be provided.Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items.The panel shall be duly supported on angle iron of size 40x40x4mm thick and panel shall include the following accessories:-
(a) Busbar chamber (4 nos TP&N 400 amp rating) (Aluminium bus bar ) SET 01 (with proper colour code ) (b) Phase indicator LED lamp assembly - 03 No (c) Complete wiring of panel with suitable gauge multi stranded copper conductor with proper colur code. (d) Digital multi functional meter to measure current,voltage,power factor etc-01, with connected CT's of suitable size. Panel should have separate chambers and busbar extensions to accomodate following switch gears:- i) MCCB TPN 250 A as incomer - 01 No ii) Outgoing MCCB 160 A - 01 Nos iii) MCB TPN 63 A - 8 Nos iv) Contactor MCX12, 4 pole,415 volts, 63 Amps - 01 No (v) Digital time switch day/weeks programme with reserve 30 minutes - 01 No Note:- a) Existing serviceable switch gears obtained from old panel board will be reused and new switch gears replaced will be measured and paid separetly. b) Panels shall be procured from firms having CPRI approval certificate. (c) Quoted rate is deemed to be inclusive of necessary earthwork & PCC.
Repair/ replacement old U/s LT panel board with out door type double door floor mounted free standing dust and vermin proof panel with IP-65 protection fabricated out of 3.15mm thick CRCA sheet of size 1 m x 1 m x 0.6m duly pretreated in seven tank proces for degreasing ,de-rusting and phosphated primer powder coated then painted with final coat of epoxy based powder coated. panel shall be having front and rear opening for installation of seperate cable alleys with proper locking arrangement with busbar chamber and switch gear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 400 mm to be kept from floor level for switch gear compartment. Extended busbar links/terminals to be provided for heat dissipation. Suitable size knockout holes for cable glands shall be provided.Paint shall be epoxy based approved shade of colour and make and size of panel duly mentioned the size of each component and switch gear layout drawing shall be submitted for the approval of Engr-in-charge before ordering the items.The panel shall be duly supported on angle iron of size 40x40x4mm thick and panel shall include following accessories:-
(a) Busbar chamber (4 nos TP&N 160 amp rating) (Aluminium bus bar ) SET 01 (with proper colour code ) (b) Phase indicator LED lamp assembly -03 No (c) Complete wiring of panel with suitable gauge multi stranded copper conductor with proper colur code. (d) Digital multi functional meter to measure current,voltage,power factor etc-01 , with connected CT's of suitable size. Panel should have separate chambers and busbar extensions to accomodate following switch gears:- i) MCCB TPN 100 A as incomer - 01 No ii) Outgoing MCCB 63 A - 03 Nos iii) MCB TPN 32 A -4 Nos iv) Contactor MCX12, 4 pole,415 volts, 63 Amps - 02 No (v) Digital time switch day/weeks programme with reserve 30 minutes - 02 No Note:- a) Existing serviceable switch gears obtained from old panel board will be reused and new switch gears replaced will be measured and paid separetly. b) Panels shall be procured from firms having CPRI approval certificate. (c) Quoted rate is deemed to be inclusive of necessary earthwork & PCC.
Supply and fix in replacement of MCCB 630 Amp 50 KA/415 volt rating four pole adjustable type complete all as specified and as directed.
Supply and fix in replacement of MCCB 400 Amp 36 KA/415 volt rating four pole adjustable type complete all as specified and as directed.
Supply and fix in replacement of MCCB 250 Amp 25 KA/415 volt rating four pole adjustable type complete all as specified and as directed.
Supply and fix in replacement of MCCB 160 Amp 16 KA/415 volt rating four pole adjustable type complete all as specified and as directed.
Supply and fix in replacement of MCCB 100 Amp 16 KA/415 volt rating four pole adjustable type complete all as specified and as directed.
Supply and fix in replacement of MCCB 63 Amp 16 KA/415volt rating four pole adjustable type complete all as specified and as directed.
Supply and fix in replacement of MCB 63 Amps TPN 240/415 Volts, 'C' curve complete all as specified and as directed.
Supply and fix in replacement of MCB 32 Amps TPN 240/415 Volts, 'C' curve complete all as specified and as directed.
Supply and fix in replacement of digital time switch day programme single phase complete all as specified and as directed by Engr in charge.
Supply and fix in replacement of contactor four pole 415 volt 63 Amp MCX 12 complete all as specified and directed by Engr in charge.
Repair/replacement of heat shrinkable type LT sleeves of capacity 1100V upto 1m length, suitable for cable size 16 to 50 sqmm complete all as specified and directed by Engr-in-charge.
All as per item no 16 above but suitable for size 70 to 120 sqmm complete all as specified and directed by Engr-in-charge.
All as per item no 16 above but suitable for size 150 and above complete all as specified and directed by Engr-in-charge.
M&L for jointing LT straight through joint kit 1100 volt , size up to 70 Sqmm 3.5/4 core complete all as specified and directed by Engr-in-charge.
M&L for jointing LT straight through joint kit 1100 volt , size of 70 to 300 Sqmm 3.5/4 core complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of 05 kVAr (heavy duty) aluminium can type (gas filled) capacitor 440 Volts complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of 10 kVAr (heavy duty) aluminium can type (gas filled) capacitor 440 Volts complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of 15 kVAr (heavy duty) aluminium can type (gas filled) capacitor 440 Volts complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of 20 kVAr (heavy duty) aluminium can type (gas filled) capacitor 440 Volts complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of 30 kVAr (heavy duty) aluminium can type (gas filled) /squire typecapacitor 440 Volts complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of 12.5 kVAr Capacitor Duty Contactor (0 No +01 NC) 440 Volts complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of 16.7 kVAr Capacitor Duty Contactor (0 No +01 NC) 440 Volts complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of 20 kVAr Capacitor Duty Contactor with auxilary contact (01 No +01 NC) 415 Volts complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of 25 kVAr Capacitor Duty Contactor with auxilary contact (01 No +01 NC) 415 Volts complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of 33.3 kVAr Capacitor Duty Contactor with auxilary contact (01 No +01 NC) 415 Volts complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of 40 kVAr Capacitor Duty Contactor with auxilary contact (0 1No +01 NC) 415 Volts complete all as specified and as directed by Engr-in-charge.
Material and labour for servicing of LT capacitor panel outdoor / indoor type of any sizes including welding,cleaning, greasing and tightening of joint complete all as specified and as directed by Engr-in-charge.
Material and labour for servicing of LT panel outdoor/indoor type of any sizes including welding,cleaning, greasing ,tightening of joint and minor patchings using weldings and rewiring complete all as specified and as directed by Engr-in-charge.
Material and labour for rewiring of of LT panel/capacitor panel of outdoor/indoor type of any sizes including metering equipments, bus connectors and replacement of connector links and spreaders complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of APFC relay ,440 volt, as per existing site requirement of suitable make and model complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of surface mounted device LED indicator(Red,green,yellow), low power consumption,surge and low voltage glow protection as on site requirement complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of digital 3 phase ammeter of class 1440 volt, complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of digital 3 phase voltmeter of class 1440 volt, 8 stage complete all as specified and as directed by Engr-in-charge.
Taking down the unserviceable LT UG cable of size of 95 to 300 sqmm 3.5 core/04 core including removing electrical connection and keeping side serviceable cable include removal of cable protection cover etc complete all as specified and as directed by Engr-in-charge.
All as per item no 39 above but size up to 70 sqmm complete all as specified and as directed by Engr-in-charge.
Exacavation in trenches not exceeding 1.5 mtr in width and depth and getting out in hard/dense soil complete all as specified and as directed by Engr-in-charge. Note:- The excavation has to be done manually only.
Returing and filling in including levelling watering and well ramming into layers not exceeding 25 cm in hard/dense soil complete all as specified and as directed by Engr-in-charge.
Removal of excavated soil to a distance not exceeding 50 mtrs and depositing at a level not exceeding 1.5 mtr from starting point complete all as specified and as directed by Engr-in-charge.
Supply and spreading riddled earth for cushioning of the UG cable in trenches complete all as specified and as directed by Engr-in-charge. Note:- Punned thickness shall be measured for payment purpose.
Supply and lay PCC un reinforced cable cover of size 250 mmx150mmx40mm , class LV type I flat for cable protection complete all as specified and as directed by Engr-in-charge. Note:- Contractor has to produce PCC cable cover test certificate from the manufacturer.
Relaying of PCC un reinforced LTcable cover of size 250 mm x 150mm x40mm item obtained from ser no 39 & 40 complete all as specified and directed by Engr in charge.
Supply and laying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs,glands XLPE insulated heavy duly galvanised steel strip armoured LT 1100 volt grade with aluminium conductors of size 150 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
All as per item no.47 above but size of 120 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
All as per item no.47 above but size of 95 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
All as per item no.47 above but size of 70 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
All as per item no.47 above but size of 50 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
All as per item no.47 above but size of 35 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
All as per item no.47 above but size of 25 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
Relaying cable obtained from taking out in trench/fixing to walls/pipe/pole with proper saddles XLPE insulated heavy duly galvanised steel strip armoured LT cable size upto 70 sqmm 3/3.5/4 core complete all as specified and as directed by Engr-in-charge.
All as per item no.54 above but cable of size 95 to 300 sqmm 3.5 core complete all as specified and as directed by Engr-in-charge.
ANAND REFRIGERATION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .