| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 CrAccepted-AOC 11 JAMES HICKEY SARANI FORMALLY KNOWN AS DACRES LANE 2ND FLOOR KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | ₹30.0 Cr | L1 | Accepted-AOC BEING LOWEST TENDER |
| 2 | L2₹30.4 CrRejected-Finance 3A RAM MOHAN MULICK GARDEN LANE UNIT NO 6A 3RD FLOOR KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | ₹30.4 Cr | L2 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 3 | L3₹30.9 CrRejected-Finance | ₹30.9 Cr | L3 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 4 | L4₹30.9 CrRejected-Finance | ₹30.9 Cr | L4 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 5 | L5₹31.0 CrRejected-Finance | ₹31.0 Cr | L5 | Rejected-Finance HIGHER THAN LOWEST TENDER |
Tender Value
₹29.6 Cr
EMD Value
₹25.8 L
Closing Date
28 Dec 2023, 6:00 pmClosed
BRIG SUSHIL KUMAR CHIEF ENGINEER
HQ CHIEF ENGINEER KOLKATA ZONE MILITARY ENGINEER SERVICES BALLYGUNGE MAIDAN CAMP GURUSADAY ROAD KOLKATA 700019
PROVN OF FASF AT PANAGARH
2023_MES_624634_1
89068/E8
Open Tender
Civil Works
720 days
GE (PROJECT) PANAGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Yes
GE (PROJECT) PANAGARH
₹25.8 L
Yes
3 Feb 2024
23 Oct 2023
30 Dec 2023
23 Oct 2023
28 Dec 2023
21 Dec 2023
Amount
NOTE (Applicable for all items/parts):- The bidders/contractors are advised to refer Notes on BOQ/SCH'A' before entry/quoting the rates. Lumpsum price workedout by the tenderer for BUILDINGS WORKS as listed in Schedule ‘A’ Part-I.
Construction of Igloo Building for 75 MT NEC 36m x 9.5m x 4.2m (LxBxH) as per CFEES drg dt 10 Nov 2014 with all fittings & fixtures etc. including RCC Retaing wall, toe wall, NAT, VIFT and compacted earth filling complete all as shown on drawing and as specified.
Construction of Igloo Building for 25 MT NEC 18m x 9.5m x 4.2m (LxBxH) as per CFEES drg dt 10 Nov 2014 with all fittings & fixtures etc. including RCC Retaing wall, toe wall, NAT, VIFT and compacted earth filling complete all as shown on drawing and as specified.
Construction of Igloo Building for 5 MT NEC 7m x 7m x 3.6m (LxBxH) as per CFEES drg dt 10 Nov 2014 with all fittings & fixtures etc. including RCC Retaing wall, toe wall, NAT, VIFT and compacted earth filling complete all as shown on drawing and as specified.
Construction of 01xESH for White Phosphorus Ammunition of size 18mx12m complete all as shown on drawing and as specified.
Construction of 2x ESH for 1.2 UNHD capacity 20MT Amn Road served of size 18mx12m complete all as shown on drawing and as specified.
Construction of Guard post cum watch tower complete all as shown on drawing and as specified.
Construction of Sentry Post complete all as shown on drawing and as specified.
Construction of static water tank 50000 glns capacity with all fittings & fixtures etc complete all as shown on drawing and as specified.
Construction of Fire Point with all fittings & fixtures etc complete all as shown on drawing and as specified.
Lumpsum price workedout by the tenderer for EARTH WORK AND EXCAVATION as listed in Schedule ‘A’ Part-II.
Lumpsum price workedout by the tenderer for EXPLOSIVE LIMIT BOARDS as listed in Schedule ‘A’ Part-III.
Lumpsum price workedout by the tenderer for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-IV.
Lumpsum price workedout by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-V.
Lumpsum price workedout by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-VI.
Lumpsum price workedout by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VII.
Lumpsum price workedout by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VIII.
Lumpsum price workedout by the tenderer for ROAD/PATH/CULVERT/ HARD STANDING as listed in Schedule ‘A’ Part-IX.
Lumpsum price workedout by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-X.
Lumpsum price workedout by the tenderer for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-XI.
Lumpsum price workedout by the tenderer for RCC DUNNAGE BLOCKS as listed in Schedule ‘A’ Part-XII.
Lumpsum price workedout by the tenderer for CHAIN LINK FENCING & GATE as listed in Schedule ‘A’ Part-XIII.
Lumpsum price workedout by the tenderer for DEMOLITION & DISMANTLING as listed in Schedule ‘A’ Part-XIV.
Sch 'A' Part-XV (MISC B&R AND E&M ITEMS) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only. SITE CLEARENCE
Material and labour for mixing of lime @ 2.5% by weight with earthin filling of traverse . Note- Only lime and mixing with rotavator is to be paid under this item .laying ,spreading and compaction etc is incl in forming embankment of earth.
INTERNAL ELECTRIFICATION
Supply & fixing LED bulb 10 watt, B22 suitable for fitting in lamp holder batten type complete all as specified and as directed.
Supply and fixing flame proof cum water proof LED bulk Head light fitting of 20 Watt, certified by CMRI, suitable for gas/ vapor group of IIA & IIIB, Zone 1 & 2 as per IS-2148 (1981) and IS-2206 Part-I having IP 66 degree of protection, cast aluminum alloy material and heat and impact resistance toughen 'A' clear glass having anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connected up with three core flexible copper conductor cable with suitable size complete all as specified and as directed.
Supply and fixing flame proof LED light fitting 40 Watt, certified by CMRI, suitable for gas/ vapor group of IIA & IIIB, Zone 1 & 2 as per IS-2148 (1981) and IS-2206 Part-I having IP 65 degree of protection as per IS-2147 (1962) of die cast aluminum alloy LM-6 construction, light grade epoxy powder coating finish of shade number 631 as per IS-5 having provisioning of one number internal earth and two numbers external screws of M4/M5 size 'O' ring endless neoprene rubber gasket, stainless steel hardware, two number 3/4 inch cable entry, cable glands, all internal electrical components pre-wired, inside white and outside light gray, internal driver type epoxy powder coating, clear heat resistance well glass complete all as specified and as directed. .
Supply and fixing flame proof distribution board, flame proof as certified by CMRI, SPN 8 way with DIN rail, suitable for isolators, MCBs and ELCBs, suitable for group-I, IIB as per IS 2148 (1981), IP-65 as per IS-2147 (1962), cast aluminium alloy LM-6 conastruction, light gray epoxy shade No 632 of IS-5 powder coating having having 'O' ring neoprene rubber gasket, hardware in external steel construction complete all as specified and directed. (Note:- Isolators, MCBs and ELCBs shall be measured and paid separately).
EXTERNAL ELECTRIC SUPPLY
Supply laying old size fly ash burnt building bricks, laid in trenches over Sand Cushion laid with axis of bricks perpendicular to the axis of LT cable for Cable Protection, complete all as specified and as directed.
Dismentling / Taking down of cradles hexagonal / rectangular fabricated with galvanised steel wire any shape and size complete all as specified and as directed.
Taking down old U/S Danger Notice Plate any type and size complete all as specified and as directed.
Taking Up/Out HT UG Cables of any Cross Sectional Area and connections and joints including Pipes, Bricks, etc of size 120 Sqmm 3 core laying in trenches or fixing with Walls/Poles, segreating serviceable Bricks/Precast covers, Pipes, Cables etc, and keep in safe custody for reuse, complete all as specified and as directed.
Relaying of HT UG cable (Serviceable cable obtained from Item No. 24 here-in- before) of size 120 Sqmm 3 core complete all as specified and as directed. NOTE : Earthworks, Sand Cushioning, Pre-cast concrete cable cover, GI Pipe, etc. will be measured and paid under appropriate Items.
Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface / footpath with the help of GI Tubing not exc. 80mm bore (dia) for passing of UG Cable, complete all as specified and as directed. NOTE: GI Pipe laid will be measured and paid separately under appropriate Item.
Material and labour for cable route indicator of cast iron for LT/HT cable (Colour Brown/Blue respectively) with 35x35x4mm MS angle iron post 1.00 Mtr long embedded in PCC 1:3:6 type C1 foundation concrete 150mm x 150mm x 300mm deep complete all as specified and as directed.
Supply, install, testing and commissioning of LT panel board outdoor type, conforming to the norms of CPRI, factory made, weather proof dust proof, powder coated confirming to IS 61439 part 1 & 2, platform mounted factory made of size 1.2 x 1.0 x 0.6m, totally enclosed dust and vermin proof openable from both front and rear side made out of 14 SWG (3 mm) thick CRCA MS Sheet and built upon suitable size angle iron frame work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. The panel should be suitable for 415 volts , 50Hz , 3 phase 4 wire system and internal connection should be provided with copper strips of suitable size, 04 Nos copper bus bar 200 Amps and necessary foundation work and comprising following:-
Supply, install, testing and commissioning of LT panel board outdoor type, conforming to the norms of CPRI, factory made, weather proof dust proof, powder coated confirming to IS 61439 part 1 & 2, platform mounted factory made of size 1.2 x 1.0 x 0.6m, totally enclosed dust and vermin proof openable from both front and rear side made out of 14 SWG (3 mm) thick CRCA MS Sheet and built upon suitable size angle iron frame work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. The panel should be suitable for 415 volts , 50Hz , 3 phase 4 wire system and internal connection should be provided with copper strips of suitable size, 04 Nos copper bus bar 160 Amps and necessary foundation work and comprising following:-
Supply and fixing LED street light fitting 45 Watt 230 V AC, luminous efficacy 120 Lumens/Watt outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including GI bracket of required shape & size as recommended by manufacturer, clamp of required length including nuts & bolts fixed on street poles complete. Make: Jaquar, Model No:LSRT02S045XC or Equivalent in Havells/Bajaj. (Note:- 34 Nos street light to be fitted on LT OH Line Pole)
Supply and fixing Junction box with terminals of size 155 x 210 x 92mm or nearest higher size made of polycarbonate body with IP 66/67 degree of protection, dust proof, water tight, shock proof, fire retardant, with internally embedded gasket fitted with heat treated bakelite terminals block and PVC glands for cable entry complete all as directed. Make: Hensel; Cat No-KF1616G.
Supply, laying & testing PVC insulated, PVC sheathed electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm, 3 core, 1100 Volts grade to connect street light to junction box complete all as specified and as directed.
Supply and fixing LED Search light with mororised system, LED light should be 300Watt, 230 V long range type with horizontal & vertical operational controls by remote control unit.
Supply and fixing All-in-one outdoor solar LED street light 30 watt with minimum 150 lumens, with in built SCC, 100Wp high efficiency Mono Crystalline Solar PV Module, minimum 12.8 V, 36 Ah capacity Lithium Ferro Phosphate battery, HDG Tubular Pole 7 mtr complete all as specified and as directed. Make: Havells/Bajaj/Jaquar. Note: PCC foundation to erect the Solar light pole shall be as per manufacturer recommendation and included in item rate.
EXTERNAL WATER SUPPLY
Supply and laying of pipe ductile Iron, socket & spigot type, Class “K-9”, 200 mm nominal dia complete all as specified and as directed.
Supply and laying of pipe ductile Iron, socket & spigot type, Class “K-9”, 150 mm nominal dia complete all as specified and as directed.
Supply and laying of pipe ductile Iron, socket & spigot type, Class “K-9”, 100 mm nominal dia complete all as specified and as directed.
Material & labour for DI specials like Bends (any type, radius and angle) tapers any type (straight, bend, increasing,decreaing or double socket etc) Tee pieces single branch "Y" junction, double branch, cross for DI pipe upto 200 mm bore complete all as specified and as directed.
Material and labour for Construction of brick masonry chamber of 90 cm x 90 cmx 90 cm [internal dimensions] suitable for 150 mm/200 mm bore sluice valve with PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundation brick wall with sub class ‘B’ brick, old size built in CM 1:6 PCC [1:2:4] type B1 [using 20 mm graded stone aggregate for coping rendering in CM [1.4] 15 MM thick including provision of MS sheet cover 3 mm thick including handle, hinges locking arrangements etc with two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces and locking arrangement including necessary excavation and earth work in any type of soil complete all as specified.
Material and labour Construction of brick masonry chamber of 60 cm x 60 cmx 60 cm [internal dimensions] suitable for 50mm bore sluice valve with PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundation brick wall with sub class ‘B’ brick, old size built in CM 1:6 PCC [1:2:4] type B1 [using 20 mm graded stone aggregate for coping rendering in CM [1.4] 15 MM thick including provision of MS sheet cover 3 mm thick including handle, hinges locking arrangements etc with two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces and locking arrangement including necessary excavation and earth work in any type of soil complete all as specified.
ROAD/PATH/CULVERT
Material & Labour for mixing of fly ash, clinker & stone dust in proportion of 1:3 :6 (i.e 10% Fly ash, 30% Clinker and 60% Stone dust materials) laying thickness of 600mm(compacted thickness) in 3 layers , watering , ramming and compacting with vibratory roller to get min CBR value 8% and Dry density 97 % placed at required camber and gradient complete as directed by Engr-in-Charge Note: - Design mix is mandatory, The unit rate quoted is deemed to include this aspect. The design mix shall be approved by the GE.
Material & Labour for 225 mm th (compacted th) wet mix macadam (WMM) (laid in three layer of 75mm each) using 40mm graded aggregates , spread using mechanical paver as specifed, rolled with power roller exc 10 tonne not exc 12 tonne and consolidated as specified gradient and camber complete as specified and as directed.
Material & Labour for cleaning and preparing the road surface and marking good for road marking applying reflective thermoplastic white road marking paint (Hot application) conforming to BIS 3262 laid down through modern propelled road marking machine in a layer of CRYSTALEX and use of all ingredients such as binder, glass ,beads,titanium dioxide ,calcium carbonate ,interfiller thermoplastic reqd for glass beads per Sqm by incorporating the white glass beads for reflectivity in 100mm width complete all as specified and directed.
Material and labour for applying evenly a tack coat with paving bitumen VG-10 grade confirming to IS : 73 at a rate of application of 0.30 to 0.40 Kg/ Sqm on bituminous surface as specified in Table 500-5 of MoRTH Specification for road and bridge work 2013, using mechanical sprayer complete all as specified and as directed.
Material and labour for bituminous premix semi dense asphaltic concrete of grade VG-30, 40 mm consolidated thickness with paving bitumen of any penetration, 5.5% binder content by weight of total mix laid using mechanical paver machine rolled and compacted to required camber and gradient complete all as specified.
Preparing unsurfaced WMM surfaces by brushing with wire brushes and removing caked mud etc sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all lose dirt etc and applying evenly a prime coat of Catinic bitumen Emulsion SS1 confirming to IS : 8887 at a rate of application of 0.70 to 1.00 Kg/ Sqm on surface of WMM/WBM as specified in Table 500-3 of MoRTH Specification for road and bridge work 2013, using mechanical sprayer complete all as specified and as directed.
FIRE FIGHTING SYSTEM
Supply and fixing Portable Fire Extinguisher water CO2 type, 9 ltr capacity confirming to IS:940/6234 suitable for fire fighting system.
Supply and fixing Portable Fire Extinguisher powder type suitable for fire type A B or C, of 10 Kg capacity confirming to IS: 13849/14609 suitable for fire fighting system.
Supply and fixing Portable Fire Extinguisher CO2 type, 5 Kg capacity confirming to IS:2878 suitable for fire fighting system.
Supply and fixing Ceiling Hook confirming to IS:927 suitable for fire fighting system
Supply and fixing Fire beater confirming to IS:8096 suitable for fire fighting system
Supply and fixing Fire bucket made out of MS Irin, 9 ltr capacity confirming to IS:2546 suitable for fire fighting system.
Supply and fixing Shovel suitable for fire fighting system
Supply and fixing Fire gong/ hand siren confirming to IS: 6026 suitable for fire fighting system
Supply and fixing Fire axe suitable for fire fighting system
DIGITEL TEMP & HUMIDITY METER
Supply, testing, commissioning and fixing of Temperature & Humidity Data Logger with the following specifications:- (a) Max / Min : Temperature reading over 0 to 100% RH : 40 degree Celsius to 70 degree Celsius. (b) Measurement ranges by PC with USB interface with data card and LCD monitor (c) Memory for 32700 readings (16350 temperatures and 16350 humidity readings) with long life battery pack with accessories including locking arrangement complete with fixing on wall.
ELECTRIC SIREN
Supply, install, test and commission electric motor siren for heavy-duty application, ideal auidable range (Diametrical) 8.0 Kms, Motor 5 HP( 2880 RPM) insulation class F/B, IP-44 , 415 volts, 3 phase, frequency 50 Hz, aluminium casting bodied, horizontal impeller complete with all mounting and accessories including canopy made out of MS channel, CGI as required to protect from heavy rain fall complete all as specified and as directed.
Supply and fixing DOL starter suitable for electric motor upto 5 HP, 415 volts, 3 phase complete all as specified and as directed.
DG SET
Supply,installation,Testing and Commissio-ning silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc. of capacity 50 KVA.Technical Specification : Stroke- 4, No. Of cylinders- 4, RPM- 1500, Cyl. Configuration - vertical lnline, Dirction of Rotation - Counter clockwise viewed from flywheel end, Method of aspiration- Turbo charged after cooled, Method of cooling- Coolant cooled, Type of Governor- Electronic, Starting system-12V Electric start, Overload capacity- 10% for 1hr. in every 12hrs. running, Duty- Continuous, Safety control- Low lube oil pressure, High coolant temp, Applicable standards - ISO 3046,BS 5514, Bore & Stroke- 97x128mm, Displacement-3.84Ltrs, Compres-sion ratio-17.5 :1, Lube oil sump cap- 9 Ltrs, Coolant capacity with engine jacket- 15 Ltrs.
Alternator. Rating: 50KVA Type: Brushless, Excitation: Self excited, self regulated (AVR), Enclosure: SPDP, Enclosure protection: IP-23, Rating: Continuous, Rated voltage: 415V, No of phases: 3Ph, Rated current: 50KVA-208Amps, Frequency: 50Hz, Power factor: 0.8pf, Class of insulation: H, Voltage Regulation: + 1%, Overload capacity10% for 1hr for every 12hrs running, Applicable standards: IS 4722/BS 5000. Accessories. Fuel tank suitable for 8hrs. Capacity shall be supplied and to be mounted inside the canopy, Exide make batteries 1 No.x12V, 90AH capacity, Battery lead, Anti-Vibration mounting pads (fitted inside the canopy), Residential silencer (fitted on inside/top of canopy), First fill of lube oil & coolant.
AMF Control Panel. The AMF control panel shall be made of 16SWG CRCA sheet, set/floor mounted, indoor type, dust and vermin proof and powder coated and suitable for 415V,3Phase, 50Hz system. The panel will be incorporated inside the canopy and shall consist of the following features: Microprocessor based AMF controller having safety features with display of following engine & Alternator parameters:- Engine Display features-Low lube oil pressure, High water temperature, overspeed, low fuel level, RPM, No. of hours run, battery voltage. Safeties- LLOP, HWT, LFL, Over Speed & earth fault relay. Alternator Display features- Ampere, Voltage, Frequency, Power Factor, Kw, Kwh, KVAR. Safeties- Over current, over/ under frequency, short circuit, current transformers of suitable ratio, 2 Nos suitalby rated 4 Pole power contactor for DG & Mains, 1 No. suitably rated MCCB with short circuit & overload protection as outgoing, Indicating Lamps for DG ON/ load ON/Mains ON, MCB for control protection, Battery charger with auto trickle & boost charging facility, Toggle switch for control ON/Off. Note: All engine & alternator parameters will be displayed through above controller only.
DEMOLITION & DISMANTLING
Taking down DB/main switch of any size and making good disturbed surface of wall/floor complete all as specified.
SEWAGE DISPOSAL
Construction of RCC Septic tank coventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 25 users.
Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 M dia X 3.0 M effective depth.
NARSINGH DEVELOPERS LLP
surendra infrastructure pvt ltd
NAND LAL PURI AND SONS PRIVATE LIMITED
Adhunik Infrastructures Pvt Ltd
Ktech Engineer Builders Co. Pvt. Ltd
M/s. Mohan Lal Jain
VERMA BROTHERS
UNITED ROAD CONSTRUCTIONS PVT LTD
LUMOS INFRA PVT LTD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid