Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.5 L+₹1.1 L (8.81%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTER SARU SECTION ROAD JAMNAGAR 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L2 | Rejected-Finance L2 | |
| 3 | L3₹13.8 L+₹1.4 L (11.1%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹14.4 L+₹1.9 L (15.6%)Rejected-Finance BLOCK NO 11 VIMLNATH APARTMENT PRATAP VILAS ROAD NEAR SATYA SAI SCHOOL JAMNAGAR GUJARAT 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L4 | Rejected-Finance L4 | |
| 5 | L5₹14.4 L+₹2.0 L (15.7%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
18 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Amit Bhat
Garrison Engineer (AF) No.1 Military Engineer Service Air Force Station No.1 Jamnagar 361 003
PROVISION OF THREE PHASE POWER SUPPLY AT MAIN GATE AND PROVN OF RAIN WATER CHANNELISATION WORK AT RADAR HEAD AND CERTAIN MAJOR REVENUE WORKS AT AF STATION SAMANA UNDER GE AF JAMNAGAR NO.1
2020_MES_327640_2
8720/E8
Open Tender
Miscellaneous Works
Item Wise
120 days
77 SU
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF JAMNAGAR NO.1
₹29,000
Yes
25 Jun 2020
4 Jun 2020
19 Jun 2020
4 Jun 2020
18 Jun 2020
4 Jun 2020
60 days
Amount
Demolition of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including removal of debries to a distance exc 1.5 Km but n. exc 2 Km, complete all as specified & directed by Engg-in-charge.
M&L for 18 to 20 mm thick machine cut & machine polished Kota stone slab as in flooring laid over and including 20 mm thick cement screed base in CM 1:6, laid, jointed & pointed with grey cement slurry including rubbing and mirror polishing complete.
M&L for 40 mm thick plain cement concrete 1:2:4, type B0 (using 12.5 mm graded stone aggregate) as in flooring, finishing the surface even and fair without using extra cement, including supply & mixing of liquid water proofing compound @ 200 ml per 50 kg of cement consumed, complete all as specified & directed by Engineer - in - charge.
Supply & fix 180 mm size UPVC (Unplasticized Polyvinyl Chloride) half round gutter of pressure rating 2.5 kg / Sqcm, fixed in position including all fitting & fixture such as, Joint Bracket, Running Outlet, Short Stop End, Support Bracket & clamp etc complete all as specified & directed by Engineer - in - charge.
Make:- Prince ( Rainfit) / Supream / JAIN IRRIGATION SYS / kisan / FINOLEX
S&F PVC (SWR) pipes 150 mm dia single socketed, in any length, joined with solvent cement, fixed on walls or floors with clamp complete all as specified and as directed. Make:- Prince / Supream / JAIN IRRIGATION SYS / kisan / FINOLEX
S&F PVC (SWR) bends 150 mm dia any radius all as specified and directed. Make:- Prince / Supream / JAIN IRRIGATION SYS / kisan / FINOLEX
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa as in roof covering / cladding to wall, molding / folding in circular / semicircular of any position and height fixed with self tapping screws as specified, as directed by Engr-in-charge
S&F Steel work in trusses fabricated with rectangular / Square hollow section, including special shaped, washers etc including cutting welding, bending in shape etc using tube of YST 310 grade confirming to to IS-4923 complete all as specified & directed by Engg-in-charge.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified & directed by Engg-in-charge.
Supply and fix hot dip galvanised mild steel section for post and struts for fencing including cutting top to shape as directed, drilling hole notching for wire etc. or flat iron fillet (for securing wire mesh etc) including all necessary drilling, bolting, using steel section of grade E-165 ( Fe-290) complete all as specified & directed by Engg-in-charge.
Note :- Coating of hot dipped galvanisation shall not be less than 86 micron (610 gram/sqm) thick. Contractor shall produce certificate regarding hot dipped galvanised steel work from the Govt Agency. All the testing charges shall be borne by the Contractor.
Supply only chain link fencing made out of mild steel galvanised wire, conforming to IS 2721 all as specified & directed. Note:- Fixing only fencing will be measured and paid separately in subsequent item of BOQ.
Fixing only chain link fencing of description fixed to steel post with mild steel flat & nut bolt etc. Note: (i)Supply only fencing will be measured and paid separately. (ii)Supply and fix mild steel nut bolt, line wire and flat will be measured and paid separately in subsequent item of BOQ.
S&F hot dip galvanised Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed at the other, or screwed at both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long & dia of shank 11 to 15 mm long.
Supply and fix hot dip galvanised 10 mm dia mild steel round bar as in line wire for chain link fencing fixed with GI wire complete all as specified & directed by Engg-in-charge.
Excavation in post holes in soft / loose soil (or similar holes) each n.exc 0.5 cum, getting out, returning, refilling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in any type of soil removing surplus soil to a distance n exc 50 m complete all as specified & directed by Engg-in-charge.
Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil all as specified.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick using excavated soil all as specified & directed by Engg-in-charge.
Removing excavated soil to distance exc 50 m but n.exc 100 m and depositing where directed at a level n.exc 1.5 m above the starting point.
M&L for PCC 1:3:6 type C 2 using 40 mm graded stone aggregate as in foundation, filling, mass concrete complete all as specified & directed by Engg-in-charge.
M&L for precast cement concrete (1:5:8) (using 20 mm graded stone aggregate) solid building blocks exe 10 cm thick, in width (with plain or inter locking joints as directed) setting in CM 1:6 complete in wall or pillars all as specified & directed by Engg-in-charge.
M&L for rendering 10 mm thick on brick / concrete surface of walls in cement mortar 1:6 finished even & smooth without using extra cement complete all as specified & directed by Engg-in-charge.
M&L for rendering 15 mm thick on brick / concrete surface of walls in cement mortar 1:4 finished even & smooth without using extra cement complete all as specified & directed by Engg-in-charge.
M&L for prepation of plastered surface of wall and applying two coats of Distemper oil emulsion over one coat of primer, after application of cement base wall care putty all as specified & directed by Engg-in-charge.
M&L for 75 mm thick plain cement concrete 1:4:8 type B2, using 40 mm graded stone aggregate, as in sub base to floors and paving etc complete all as specified & directed by Engg-in-charge.
Removal of existing roof treatment consisting of screed bed, tar felts etc, including removal of debries to a distance exc 1.5 Km but n. exc 2 Km.
M&L for plain cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregate, (Avg 50 mm thickness) in roof for padding to achieve the 1:40 slope complete all as specified & directed by Engg-in-charge.
M&L for screed bed 10 mm thick on concrete surface in cement mortar (1:4) finishing the surface even and smooth without using extra cement, including supply & mixing of liquid water proofing compound @ 200 ml per 50 kg of cement consumed complete all as specified & directed by Engineer - in - charge.
Material and labour for water proofing treatment by applying one coat of oil base bituminous primer @ 0.3 Kg / Sqm with brush / roller, laying of 3 mm thick APP based polymer modified membrane (mineral finish) reinforced non-woven polyester, weight not less than 3.50 Kg / Sqm and sealing all the over laps 100 mm in length side and 100 mm in width side of membranes laid with torch application complete all as specified & directed by Engg-in-charge.
S & F Collapsible steel gates, top hung, consisting for channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with roller, holdfasts and brackets, fixed in existing opening and making good to disturbed surface complete all as specified & directed by Engg-in-charge.
Supply fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron of approved color) door shutter with frame, partly glazed with 5 mm thick tinted glass and partly panelled with 9 mm thick prelaminated particle board with both side decorative laminated including rubber bead joining cleat for fixing in position, aluminium door handle 150 mm size, aluminium barrel tower bolt 200 mm size etc all as specified below complete all as specified and directed.
(a) Frame (top & side) section shall of size 101.60 x 44.75 x 2.4 mm ( Section No 14021) (b) Vertical Members of shutter Section shall be of size 85.00 x 44.45 x 2.00 mm (Section No 19560) (c) Top Members of shutter Section shall be of size 83.50 x 44.45 x 2.00 mm (Section No 19581)......
(d) Lock rail (Middle member) of shutter Section shall be of size 150.00 x 44.45 x 3.00 mm (Section No 19596) (e) Bottom Members of shutter Section shall be of size 150.00 x 44.45 x 3.10 mm (Section No 19584) (f) Glazing clip for securing glass of shutters shall be of 0.80 mm thick (Section No 19370).
Note:- (i) Section No given above are of make Jindal, Contractor may use similar section of other make mention in Appx B. (ii) Floor door spring & lock will be measured & paid separately.
S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed
S&F 100 mm size 4-lever mild steel mortise lock vertical type with two keys etc complete.
M&L for providing dry river sand as in sand cushioning to under ground PVC cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: For measurement purpose, puned thicness of sand will be considered.
Supply & lay ISI marked & confirming to IS - 5820 - 1970, unreinforced precast concrete cable cover, Class LV , Type I , flat size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified & directed by Engg-in-charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 10 Sqmm 04 core laid in trench / passing through duct and connecting and testing complete all as specified & directed by Engg-in-charge.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 50 Sqmm 3.5 core laid in trench / passing through duct and connecting and testing complete all as specified & directed by Engg-in-charge.
S&F Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way, vertical type with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, double door type 415 volts, fixed flush to wall complete all as specified and directed.
S&F Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 230 volts, double door type, fixed flush to wall complete all as specified and directed.
Supply and fix MCB’s single pole 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix MCB’s single pole & neutral, 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix MCB’s triple pole & neutral, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix MCCB 63 Amp, triple pole & neutral, breaking capacity 16 KA, 415 V - 50 Hz, fixed thermal and magnetic setting type, fixed in and including factory made powder coated sheet metal enclouser & connecting complete all as specified & directed by Engr in charge.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC conduit not less than 25 mm bore with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete.
Note: 2 Runs of main cable and one run earth wire with PVC conduit will be measured as one RM for payment.
Supply and fix / laid in trenches 80 mm bore galvanised steel water tubing, light grade for protection of cable, including necessary fittings / fixture etc complete all as specified and as directed by Engineer-in-Charge.
M&L for 100 mm thick PCC 1:2:4 type B2 using 20 mm graded stone aggregate for making good disturbed surface of road cutting , finish the surface fair & even complete.
S&F LED Flood Light fitting 240 watt, lumen Efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, .......
………..Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed in position with MS flat iron clamp & nut bolt etc & connecting complete all as directed by Eng-in-charge.
Supply & fix round, 2 core cable, PVC insulated and PVC sheathed, copper conductor of size 4 Sqmm, for electric connection from feeder / looping box / street light over head line to street light fitting drawn through and including mild steel ERW conduit not less than 20 mm dia.
S&F Sheet moulding compound (SMC) junction box of size 280 mm x 170 mm x 130 mm, comprising three phase aluminium bus bar and one No MCB SP, 06 Amps C type, fixed on pole with mild steel clamps, nuts and bolts complete.
M & L Surface excavation n exc 30cm deep and averaging 15cm deep and getting our soft/loose soil complete.
M&L for 100mm thick cement concrete 1:4:8, type D-2, (using 40 mm graded stone aggregate) as in Sub base / path/ flooring complete all as speicified and as directed.
M&L for 100mm thick cement concrete 1:2:4, type B-1, (using 20 mm graded stone aggregate) as complete all as speicified and as directed.
M/s SK Traders
Jagdamba Engineering
Nirmal Construction
MAHENDRA ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .