Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹29.8 L+₹1.3 L (4.47%)Rejected-Finance 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L3₹29.8 L+₹1.3 L (4.57%)Rejected-Finance 578 AVAS VIKAS JANAKPURI B IZATNAGAR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | L3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L4₹29.9 L+₹1.4 L (4.77%)Rejected-Finance GE WEST BAREILLY | L4 | Rejected-Finance Over all rates are higher than L-1. | |
| 5 | L5₹30.0 L+₹1.5 L (5.13%)Rejected-Finance C 3 SHAHDANA COLONY BAREILLY 243005 | BAREILLY | BAREILLY | UTTAR PRADESH | 243005 | L5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
9 Sept 2023, 6:00 pmClosed
GE WEST BAREILLY
GE WEST BAREILLY
SPECIAL REPAIR TO BLDG NO P-64 OF COMMUNICATION COMPLEX AND PROVISION OF COVERED PARKING SHED WITH HARDSTANDING FOR UB AREA SIGNAL REGT UNDER AGE B/R - I OF GE WEST BAREILLY.
2023_MES_614653_1
8145/C/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE WEST BAREILLY
₹96,000
Yes
4 Oct 2023
19 Aug 2023
11 Sept 2023
19 Aug 2023
9 Sept 2023
4 Sept 2023
Amount
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 including Demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed.
M & L for rendering (on internal surfaces) 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth without using extra cement including taking down existing cement plaster complete all as specified and directed.
M & L for rendering (on external surfaces) 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and smooth without using extra cement with mixing of water proofing compound including taking down existing cement plaster complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified.
M & L for rendering 5 mm thick cement plaster on cement concrete surfaces of ceiling with cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of new plastered or previously untreated surfaces of walls and applying two coats of oil bound distemper and applying 2 mm thick putty by washing rubbing down and stopping of ditempered and painted surfaces complete all as specified and directed
M & L for preparation of old plastered or previously untreated surfaces of walls and applying two coats of oil bound distemper and applying 2 mm thick putty by washing rubbing down and stopping of ditempered and painted surfaces complete all as specified and directed
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of 2 mm thick wall care putty complete all as specified and directed.
M & L for preparing old plastered wall surfaces and applying one coat of cement base paint over one coat of 2 mm thick wall care putty complete all as specified and directed.
M & L for preparation of newly plastered or un-plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
M & L for preparation of old plastered surfaces of ceilings and applying one coat of white wash complete all as specified and directed.
M & L for providing 25 mm thick cement concrete 1:2:4 type B-0, using 12.5 mm graded in floors, finished rough to receive floor tiles complete all as specified and directed.
M & L for vitrified ceramic light shade coloured tiles 10 mm thick (Square or Rectangular) polished, area of each tile not exc. 0.36 Sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile, including 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough, including Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
All as per S.No 14 above but in Vertical Surfaces and over 10 mm thick screed bed or backing layer in cement mortar 1:4 complete all as specified and directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough including Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M & L for glazed ceramic white tiles 450 mm X 350 mm X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile, rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and smooth, including dismantling floor, hearth or wall tiling / stone slabs and removing servicable tiles to store and rubbish off the premises complete all as specified and directed.
S & F of 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like, set in over and including 15 mm thick cement screed in cement mortar 1:4 and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including formwork, pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with round bull nosing edging including Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-1, using 20 mm graded stone aggregate as in plinth protection finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 12 mm wide joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed.
M & L for use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200 mm thick horizontal or slopping in rough finished surface of concrete complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in chajjas and the like complete all as specified and directed
Taking down Chowkats or frames with shutters (Without taking off shutters from the frames) exceeding 1.5 sqm but not exceeding 4.0 Sqm each including iron mongries, hold fast etc and making good the disturbed portions of walls in Cement Mortar 1:4 complete all as specified and directed.
Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) and removing from site and making good the disturbed portions of walls in Cement Mortar 1:4 complete all as specified and directed.
S & F of anodised powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators or partitions with one or more rebates including joining cleat etc. for fixing complete all as specified and directed.
S & F of anodised powder coated (minimum thickness of powder coating 50 micron) aluminium door shutters, aluminium section weighing 0.55 Kg per running metre including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos. in each door, hinges, anodised aluminum snap beading, screws etc. complete all as specified and directed.
S & F of anodised powder coated (minimum thickness of powder coating 50 micron) aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg per running metre including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as one No. 150 mm long peg stay, two Nos. 100 mm size B-21 type hinges, one No. suitable size handle etc. complete all as specified and directed.
S&F Aluminium Grill with Bulb height 4.5m square shape fixed on frame including necessary fixing arrangement like U-Clip, flat aluminium section matching with window & dia of grill complete all as specified and directed.
S&F tinted Sheet glass 5.5 mm thick, pin head type in squares exc 0.5 sqm in each pane in Aluminium Window, door and partition wall and complete all as specified and directed.
S & F of galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S & F of 4 mm thick E-board classic (everest / equivalent) tiles for insulation and accoustic purpose 60 x 60 cm with and including powder coated galvanium iron snap grid with 32 x 25 x 1.5 mm thick tee section and 32 x 25 x 1.5 mm thick angle section with all hanging / supporting arrangements as in false ceiling with and including taking down old ceiling with frame and making good disturbed surfaces complete all specified and directed.
S & F of 5 mm thick and 35 mm wide PVC sheet fillet for fixing of wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing given on MES schedule Part – II (2020) complete all as specified and directed.
M & L for 5mm thick Prelam Coloured PVC sheet with required angle, strips, & channel feathered at the edges for fixing on solid PVC lining, insulated PVC wall lining, and solid PVC partitions inclusive of solvent cement and fixing at site, inclusive of taking down old wall panelling complete all as specified and directed.
S & F of solid PVC door frame of size 50 mm X 47 mm made out of 5 mm thick plain coloured PVC sheet reinforced with mild steel square tube as per specification and drawing given on MES schedule Part-II (2020) complete all as specified and directed.
S & F of 30 mm thick (style thickness) factory made solid panel PVC shutter consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheets beading and joined together with solvent cement as per specification and drawing given on MES schedule Part-II (2020) complete all as specified and directed.
S & F of 300 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S & F of 150 mm long extruded anodised aluminium alloy handle, fabricated type complete all as specified and directed.
S & F of 100 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed.
S & F of 500 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part-I and hoisted, fixed in position, inclusive of dismantling of water tank exc. 250 Litre but not exc. 500 Litre capacity complete all as specified and directed.
S & F of 20 mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gram) complete all as specified and directed.
S & F in repairs 20 mm bore gunmetal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S & F of 15 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors, including taking up or down 15 mm bore steel water tubing and connection complete all as specified and directed.
S & F of 20 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors, including taking up or down 20 mm bore steel water tubing and connection complete all as specified and directed.
S & F in repairs Vitreous China wash basin white, flat back size 580 x 450 mm including waste coupling brass, waste pipe, chain and plug and porcelain stopper, brackets complete all as specified and directed.
S & F of fancy type 15 mm bore brass chromium plated mixer for mixing hot and cold water screwed down for iron pipe and fixed to WHB complete all as specified and directed
S & F in repair 15 mm bore bib tap, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repair 450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
S & F of 15 mm bore fancy type, chromium plated angle valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F of 20 mm dia brass chromium plated tubular towel rail ‘D’ type 60 cm long between flanges, including one pair of fixing brackets complete all as specified and directed.
S&F in repairs Vitreous China Wash down water closet (Pedestal Pattern) white complete, including connection to drain pipe and to flushing pipe, jet spray, anti syphonage pipe, etc complete all as specified and directed.
S&F in repairs plastic water closet white seat cover closed pattern with flat bottom cover and mild steel chromium plated or aluminized hinging device complete all as specified and directed.
S & F of PVC low level white flushing cistern 10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, brass screws, handle etc complete all as specified and directed.
S&F vitreous china bowl urinal flat back, size (465 x 355 x 265) mm white (minimum) with grating, waste pipe and union for discharge pipe complete all as specified and directed.
M & L for rendering on roof, vertical surface of mortar, 15mm thick in CM 1:4 over roof slabs for laying water proofing treatment mixed with using water proofing liquid @ 150ml per bag of cement including application of cement slurry over existing roof @ 3kg/Sqm complete all as specified and directed. Note Water Proofing liquid shall be measured and paid seperately.
S&F brass chromium plated health faucet with 1.0m long flexible tube and wall hook screwed for iron pipe fancy type long body and hanging arrangement complete all as specified and directed.
S & F of 140 mm dia grating stainless steel (minimum weight 50 gram) complete all as specified and directed.
S & F in repair fancy type glass corner 300 mm radius of 10mm thick toughened glass with CP railing fixed with fancy type screws complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint laid in trenches or in floors or wall with necessary fittings, including demolition and breaking up drain pipes of 100 mm bore (salt glazed stoneware, AC or reinforced concrete or PVC) set in cement mortar complete all as specified and directed.
S & F 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
M & L for providing 100 mm thick cement concrete 1:3:6 type C-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor finished even and rough complete all as specified and directed.
M & L for chequered cement concrete tiles of size 250 X 250 X 22 mm thick with grey cement and pigment set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in floor complete all as specified and directed.
M & L for 25 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in sub floor over RCC roof slab, finished even and rough complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster in cement mortar 1:4 including mixing of water proofing compound as per manufacturer’s instructions on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement for laying water proofing treatment complete all as specified and directed. NOTE: - WATER PROOFING COMPOUND SHALL BE MEASURED AND PAID SEPARATELY AS SUPPLY ONLY.
NOTE FOR ITEM NO 66.00 :- (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate with using Dr fixit pidilite LW(+) , of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 85/25 confirming to IS-73, [email protected] Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.30 Kg/Sqm (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen (v) Exposed surfaces of APP membrane shall be applied with two coat of bituminous aluminium paint @ 150 ml/Sqm. (vi) Above aspects are deemed to be included in quoted rate.
Dismantling of corrugated or semi corrugated asbestos cement sheets in roof covering complete all as specified and directed.
S & F of rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantry, rails, fastening, heavy bracket framing (Beam, tee, angle, channel or flat section), including distance pieces, cleats etc. confirming to Fe-410-S including cutting, welding etc. complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F in repair stainless steel drapery rod 20mm dia of 1 mm thick of approved quality with decorative design as approved brackets including fitting with 80mm long SS screw with 75mm long wooden gitty of appropriate size in each end and intermediate support fixed in brick / concrete wall complete all as specified and directed.
Surface dressing not exc. 15 cm deep as in soft / loose soil complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc. 0.50 Cum, getting out in soft / loose soil, returning, filling and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm watering and removing surplus soil to a distance not exc. 50 m and making good surface complete all as specified and directed.
M & L for providing plain cement concrete, type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M & L for providing 100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor finished even and rough complete all as specified and directed.
M & L for 75 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in sub floor of floor finishes, finished even and rough for receiving tiles complete all as specified and directed.
M & L for 80 mm thick, M-40 grade machine pressed pre-cast concrete interlocking paver block confirming to IS 15658-2006 with grey cement and pigment in any shape and size, laid dry over and including 25 mm thick sand cushioning complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S & F in repair, LED light fitting, high lumens batten type, housed in extruded from powder coated aluminium, 20 Watt for soft diffuser lighting with and including lamp and connecting up complete with PVC insulated and PVC Sheathed round flexible three core copper conductor cable of suitable size and testing on completion complete all as specified and directed
S & F in repair 2' x 2' LED ceiling mounted LED light fitting 36 watt complete all as specified and directed.
M & L for in repair earthing complete with galvanised iron earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 15 mm bore including testing on completion of job complete all as specified and directed.
Taking Down Ceiling Fan of any size and place in safe custody by the contractor complete all as specified and directed
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed
S & F of 1100 volts grade heavy duty 4.00 Sqmm size two single core PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC conduit medium grade not less than 20 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of 4.0 Sqmm size stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. NOTE: - TWO SINGLE CORE CABLES ALONG WITH EARTH WIRE AND PVC CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH.
S & F in repair sheet metal enclosure Box with MCB 20 Amp Single Pole Complete all as specified and directed.
Taking Down Split AC indoor and outdoor unit including copper piping and connected items and placed it in safe custody by the contractor and reinstallation it into the same locationand replaced unservicable copper piping and connected accessories to make it servicable and completing the work complete all as specified and directed. Note Quoted rate shall be deemded to be inclusive of Cost of Unservicable copper piping, Jointing Accessories, and Gas Changing.
S & F Split AC Copper Piping of Standard size connecting to indoor unit to outdoor unit complete all as specified and directed.
M & L for point for One light point / fan point (Independent point), controlled by one, one way switchwiring with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (FRLS) drawn into and including non-metallic PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed with and including necessary chase cutting on brick / stone masonry walls and making good as per existing and sunk cast iron or 1.2 mm thick pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded copper conductor cable (FRLS) as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed.
S & F of switch piano flush button single pole 230 volts, one-way 15 Ampere complete all as specified and directed.
S & F of ceiling rose three phase, PVC / polycarbonate isolated body complete all as specified and directed.
S & F for Distribution board (DB) IP 42 made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar neutral bar earth bar ,single pole and neutral 240 volts ,flush to wall complete for fixing of MCBs, Isolators etc complete all as specified and directed
S & F MCB, SPN, type Curve 'C', 10KA, P, 32 Amps, 240 Volts complete all as specified and directed
S & F MCB, type Curve 'C', 10KA, SP, 6 to 32 Amps complete all as specified and directed
Supply, laying and testing UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm, 2 core fixed on wall / floor with fixing arrangement such as saddle, clips, etc complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for sand cushioning with layer of sand 8cm before laying of cable and 15cm after laying of cable in trenches complete all as specified and directed. Note:- Punning thickness of 18cm shall be considered for payment.
Supply & laying of sub class old 'B' burnt bricks laid as cable protection cover complete all as specified and directed.
S&F galvanised, steel water tubes 40mm bore of pipe medium grade with all fittings laid in trenches complete all as specified and directed
S & FLED light fitting, high lumens batten type, housed in extruded from powder coated aluminium, 20 Watt for soft diffuser lighting with and including lamp and connecting up complete with PVC insulated and PVC Sheathed round flexible three core copper conductor cable of suitable size and testing on completion complete all as specified and directed
NOTE- Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
R K CONSTRUCTION
UTTRAKHAND BUILDERS
Goel Enterprises
hardeep singh enterprises
Builders Harpal
Harsha Consultant and Builders
VISHAL CONSTRUCTIONS
REHAN CONSTRUCTIONS
M/S YASHCON CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .