Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹21.3 L+₹93,246 (4.57%)Rejected-Finance 364 MAHAVEERPURAM BEHIND FUN WORLD CHOPASNI ROAD JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹22.2 L+₹1.8 L (8.70%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹22.7 L+₹2.3 L (11.2%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹22.8 L+₹2.4 L (11.9%)Rejected-Finance 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 UDYAM RJ 01 0091182 | AJMER | RAJASTHAN | 305001 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹32.7 L
EMD Value
₹65,500
Closing Date
18 Aug 2020, 6:00 pmClosed
Garrison Engineer Banar
Garrison Engineer Banar, Jodhpur-342027
SPECIAL REPAIR TO PERIMETER CABLES,POLES,LIGHTS FROM GUARD POST NO 15TO39 OF 19 FAD,PROVN OF 09XDESERT COOLER WITH STAND FOR 751 (I) TPT PL ASC CIV GT,PROVN OF 50XDESERT COOLER FOR OR LINE OF 19 FAD AND PROVN OF 186XCEILING FAN AT BANAR
2020_MES_358967_3
8820/07/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
BANAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer Banar
₹65,500
Yes
5 Oct 2020
28 Jul 2020
20 Aug 2020
28 Jul 2020
18 Aug 2020
4 Aug 2020
Amount
Part-I
Taking down old unserviceable LT UG cable and Supply, laying,testing, commissioning in replacement of LT under ground cables of 1100 volts grade XLPE insulated, PVC sheathed heavy duty armoured with multi stranded aluminum conductors with IS-1554 marked, laid in trenches or fixed to wall/ poles, passing through pipe, of cross sectional area 16 Sqmm x 2 Core complete all as specified and direct.
All as per item No 2.00 above but cross sectional area of 16 sqmm x 4 core complete all as specified and direct.
All as per item No 2.00 above but cross sectional area of 35 sq mm x 3.5 core complete all as specified and direct.
All as per item No 2.00above but cross sectional area of 70 sq mm x 3.5 core complete all as specified and direct. Note : The heavy duty lugs/thimbles to crimp the LT cable deemed to be included in the rate qoted against items No 2.00 to 5.00
Excavation in trenches in any type of soil not exc 1.5 mtr in depth and 1.5 mtr wide and getting out for laying of cables complete all as specified and directed by Engr-in-charge.
All as per ser No 6.00 above but depth exc 1.5 mtr but not exc 3.00 mtr
Returning and filling in including spreading, leveling , watering and well ramming in layers not exceeding 25 cm thick of excavated earth complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing at a leval not exceeding 1.5 mtrs above the starting point complete all as specified and directed.
M&L for tibba sand filling in trenches dry and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed. Note :- (a) Punned down thickness only shall be measured and paid. Punned thickness shall not be less than 18 cm. (b) Contractor shall produce documentary evidence in support of tibba sand brought from outside MOD land
Labor only for relaying the jodhpur stone quarry stone slab cover 25 to 30cm in width, 60cm long and 40 to 50mm thick laid in trenches and abutting each other with gap between adjacent slab not exceeding 10mm over sand covered under ground cables complete all as specified and directed by Engr-in-charge. Note :- Old Jodhpur stone obtained from serial items No 2.00 to 5.00 shall be re-used after cleaning.
M&L for laying jodhpur stone quarry stone slab cover 25 to 30cm in width, 60cm long and 40 to 50mm thick laid in trenches and abutting each other with gap between adjacent slab not exceeding 10mm over sand covered under ground cables complete all as specified and directed by Engr-in-charge.
S&F in replacement of galvanised tubes 50 mm bore light grade with all necessary fittings like bend, elbow etc for passing of cable including all necessary clamps if required and all as specified and directed.
S&F in replacement of galvanised tubes 80 mm bore light grade with all necessary fittings laid in trenches including all necessary clamps if required and all as specified and directed.
Supply and Fixing the flexible PVC pipe green and white colour mixed (spiral pipe) 50 mm dia to fit with GI pipe to make free curve to run the LT cable inside LT pole coping with proper bracing clamps and all as specified and directed. Make:- Supreme/ Prince/ Finolex/ Prayag
Supply and errecting in replacement of Prestressed concrete pole, 9.0 meter long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 including painting alternative black & white strips of 30 cm width upto 1.5 mtr above ground level and including dismantling and taking out the damaged/old PCC pole and setting aside within 50 mtr distance and opening the street light bracket, street light fitting from old pole and refixing the same on new pole for street light fitting and all as required at site or directed by Engr-in-charge.
S&F in replacement of 40 mm dia GI pipe bracket (light grade) bent to shape of length not less than 1.2 mtr including fixing on wall/pole using flat iron clamps of size 25 x 3mm, nuts,bolts,washers etc includig painting with two coats of alluminium paint over one coat of red oxide primer suitable for street light fittings all as specified and directed by Engr-in-charge.
M&L for plain cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregate) for foundation of pole / stay including necessary form work etc complete all as specified and shown in SSR.
M&L PCC (1:3:6) Type C1 using 20 mm graded stone aggregate for coping of poles or in base of plate form including form work & including dismantling the old broken coping of existing poles with taking out the existing GI pipe and cables, keeping aside for reuse in any situtaion as required and directed at site
M&L for earthing complete with galvanised steel earth plate electrode size 600x600x6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead wire 4.0 mm dia means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh refilling with vegetable soil without bolders and stones, gravels and aggregate etc,and CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion. Note:- (a)The earth pit shall be refilled by boulders free from vegetable soil. (b) Earth shall be tested by the contractor in presence of Engr-in-Charge and record shall be maintained for ready reference.
Surface excavation not exceeding 30cm deep and averaging 15 cm deep and getting out in any type of soil all as required at site or as directed.
Supply and Fixing in replacement of loop-in/loop-out box of outer size 250x210x115mm made out of FRP body (hot moulded type) with IP-63 protection and locking with screws alongwith 5/6 Amp rating MCB SP-01 No, up to 50 Amp rated 3 pole connector suitable to insert the cable size 25 Sqmm-01 No,with neutral link and din rail suitable for mounting the MCB/Connector etc complete in side box and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and out going cales and all as specified and directed.
Supply and Fixing in replacement of Rigid non-metallic PVC conduit (ISI marked) 20 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends andfixing accessoriessuch as couplers, locknuts, saddles, pipe hooks etc on steel tubular/PCC/RCC Poles and all as specified and directed.
Supply installation, testing and commissioning in replacement of panel board 3 phase and neutral 415 volt outdoor type factory made free standing, inter locking arrangement, floor mounting, dust and vermin proof cubical type IP-54 protection fabricated with 3.15 mm CRCA sheet outer shell and 2.0 mm thick CRCA sheet of inner shell with anti corrosive coating and finally polyester powder coating in finite gray shade fully compartmentalized design with 4 No’s of aluminum bus bar of 300 Amp pre-wired with suitable size of Aluminum strip with sleeves of suitable colour including suitable GI strip (for earth) and 25x3 mm thick angle iron and PCC work for foundation up to 45cm above the ground level including taking down the old unsv LT panel and all as specified with supply and fixing all as required and directed at site for the following :-
(a) Incoming :- (i) MCCB 160 Amps 36 KA, 4 pole 415 volts thermal magnetic release type - 01 No. (ii) Ammeter 0 to 300 Amp digital type with suitable ratio of CT's. (iii) Voltmeter 0 to 500 volts digital type having arrangement to check phase to phase, phase to neutral (iv) LED Indicating lamp. (v) Bus bar chamber having insulated aluminum bus bar 300 Amp and neutral. (vi) Chamber of suitable size for incoming and out going cables with arranging of suitable size cable glands.
(b) Outgoing:- (i)MCCB 63 Amps 25 KA 415 volts 4 pole with adjustable thermal release -2 No (ii)MCB 40 Amps 10 KA 230 volts single pole and neutral 'C' series -2 Nos (iii)MCB TPN 63 Amps 415 volts 10KA 'C'Series-01 No. (iv) Contactor TP 50 amps -01 Nos with operating coil 240 volts (v) Digital Time switch 2 module type 24 hrs with DC battery for power back up. (vi) By pass arrangements with tggle switch to operate the street lights for maintinance/checking as per requirement. (vii) Necessary connection with 4 Sqmm copper wire for all measuring meters and other connected instruments to smooth function of measuring instruments all as required and directed
M&L for earthing in replacement with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth, GI strip of size 32X6 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point on completion with and including 40 mm bore GI light grade protection pipe for earth, GI strip 32x6 mm dia, PCC pit with angle iron frame 300 x 300mm size, CI made pit cover in PCC 1:2:4 type B-1 reinforced with 8 mm dia tor bars @ 80mm C/C, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work complete all as specified and directed by Engr in Chanrge. Note :- (a)The earth pit shall be refilled by boulders free from vegetable soil. (b) Earth shall be tested by the contractor in presence of Engr-in-Charge and record shall be maintained for ready reference.
Supply and connecting PVC wire 4 sqmm nominal area 3 Core multi stranded aluminum conductor PVC sheathed and weather proof round/flat shape and drawn through PVC conduit and connecting to Street light fittinf on PCC/RCC/Steel pole alla s specified and directed at site by Engr-in-charge.
Part-II
Fixing only desert cooler ,electrically driven, directly coupled with single phase,230 Volt,50Hz electric motor connected control wiring with 1.5 sq mm x 3 core PVC insulated FRLS grade sheathed copper conductor complete all as directed by Engineer in charge. NOTE: 1. Water proof ply wood of suitable size, 4mm thick for closing/packing the air gap of window are deemed to be inclusive in the rate quoted for fixing of desert cooler. 2. The desert cooler shall be issued under sch 'B' free for fixing only.
M&L for Point wiring complete with 1.5 Sqmm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable in and incl PVC casing capping 25mm wide (ISI marked) with accessories fixed to surface of wall/ceiling with PVC sleeves/dash fasteners and cadmium plated screws as per relevant IS incl pressed steel terminal boxes (sunk in wall) with 3.00mm thick plastic laminated sheet top cover with 1.5 sqmm insulated in sheathed PVC covered copper conductor FRLS common earth and connecting to earth dolly for one socket outlet 3 pin 5 Amp on independent board.
Supply and fixing switch socket combination 2 in 1, 5pin, 5Amp single pole, flush type all as specified and directed by Engr-in-Charge.
M&L for float valve 15mm dia with PVC float complete all as specified and directed by Engr-in-Charge.
M&L for rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) of capacity 250 Ltrs hoisted and fixed in position complete all as specified and directed
M&L for GI tubing 15mm dia medium grade with all fittings complete laid in trenches or fixed to walls all as specified and directed by Engineer-in-Charge.
M&L for stop valve, cast copper alloy, screwed down ,high pressure, with crutch or butterfly handle, screwed both ends for iron pipes or for unions and fixed of size 15mm bore complete all as specified and directed
M&L for PVC connections 15mm size with PTMT nuts of length 600mm length complete all as specified and directed
M&L for desert cooler stand made out of MS angle of size 40x40x6mm and MS flat 40x6mm suitable for size 0.8x0.8mtr with angular support duly fixed on wall by fastner or by grouting incluidng painting with tow coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and directed
Supply and fix in repair ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or brass ferrule 15mm bore complete all as specified and directed
Cutting and threading of existing 25mm dia GI tubing in position and S&F Tee (25x25x15 mm)-01 No, Nipple 150 mm in length 15mm dia 01 No. socket 15mm dia 01 No, union 25mm dia 01 No. for water filling arrangement in desert cooler all as directed by Engr-in-charge.
Part-III
Hanging only ceiling fan of 1400 mm sweep and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed by Engr-in-Charge Note :- Ceiling fan shall be issued under Sch 'B' free for fixing only
Supply and fixing, ceiling fan regulator electronic stepped flush type 230 Volts, ISI marked with valid CML No and connecting up on the existing phenotic laminated sheet complete all as specified and directed by Engr-in-Charge.
M&L for provided fan hook with suitable size anchor farshner including hook with drilling and making good the surface with cement concrete etc all as directed by Engr-in-Chage.
M/s. Dhananjay Construction
Shri Electrical Enterprises
MAHARISHI GAUTAM CONSTRUCTIONS
M/S JAGDAMBA ENTERPRISES
Surendra Singh
M/S Balkishan Panwar Construction
KRISHNA CONSTRUCTION COMPANY
M/S AUTOMATION AND SWITCHGEAR CONTROL
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .