Loading…
Loading…
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
15 Sept 2026, 6:00 pmDue today
GE (AF) Jodhpur
GE (AF) Jodhpur
REPAIR/ MAINT OF FLAME PROOF FITTINGS, WIRING AND CONNECTED ITEMS IN CERTAIN TECH BLDGS AT AF STN JODHPUR
2026_MES_786701_1
8504/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Jodhpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹80,000
Yes
27 Aug 2026
27 Aug 2026
17 Sept 2026
27 Aug 2026
15 Sept 2026
10 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully copper/ aluminium point wiring of light, fan, socket or power complete including removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors etc. complete all as specified and as directed by Engineer-in-Charge. | 315 | POINT | - | - |
| 2 | M&L for cutting chases, pinning in brick wall, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and as directed. | 150 | RM | - | - |
| 3 | M&L for cutting chases, pinning in concreate/ stone wall, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and as directed. | 175 | RM | - | - |
| 4 | M&L for point wiring complete with 1.5 Sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade IS-694 (Phase - Red/ Blue/ Yellow, Netural -Black and earth continuity conductor 1.50 Sqmm Green) drawn through and including stove enameled steel conduit not less than 20mm x 12mm, ISI marked including accessories like bends, tees junction boxes, etc. fixed on wall or ceiling etc. including 1.5 Sqmm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size white sheet cover for mounting swiches, sockets, fan regulators etc. complete for one flame proof light point/ flame proof fans/ flame proof exhaust fans point controlled by one flame proof rotary switch 6/ 10/ 16 Amp complete all as specified and as directed.
Note:- Necessary chases cuttings for concealed wiring and making a good of distrubed surfaces are measured and paid under relevant items. | 150 | POINT | - | - |
| 5 | All as per Item No. 04 above but with 2.5 Sqmm cable for independent one 6 pin 6/ 16/ 32 Amps socket outlet in and including 2.5 Sqmm PVC insulated copper conductor unsheathed 1100 V grade IS -694 FRLS cable for continuous earth wire. | 85 | POINT | - | - |
| 6 | M&L for point wiring for modular accessories with modular metal flush box and cover plate with frame of suitable size complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade, drawn through and including casing caping/ open conduit including 1.5 Sqmm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire terminated in new modular sunken boxes and modular metal flush box of required size at site including all connected accessories, box made from thickness not less than 1.6mm GI sheet, factory made for one 3 pin socket outlet, 5 Amps on independent board complete all as specified and as directed.
Note:- Necessary chases cuttings for concealed wiring and making a good of distrubed surfaces are measured and paid under relevant items. | 40 | POINT | - | - |
| 7 | All as per Item No. 06 above but with cable of size 2.5 Sqmm PVC insulated cable on independent board for power plug 15 Amps. | 40 | PER POINT | - | - |
| 8 | S&F in repair modular switch, 01 way, 06 Amps, 240 Volts complete all as specified and as directed. | 40 | EACH | - | - |
| 9 | S&F in repair modular switch, 01 way, 16 Amps, 240 Volts complete all as specified and as directed. | 40 | EACH | - | - |
| 10 | S&F in repair modular socket, 02 module, 06 Amps, 240 Volts complete all as specified and as directed. | 40 | EACH | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
8504TENDER.pdf
Tender Documents • 1.05 MB
BOQ_881608.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .