JSD Katrain
Restoration of rain damages to FIS Bashing GP Bashing in Tehsil Distt Kullu HP SHCO Main Channel at RD 0 to 50500 to 550 3000to 3050 mtrs
2026_HPIPH_148644_1
7006-40 dated 23-11-2026
Open Tender
Civil Works
Item Rate
KATRAIN
Please refer Tender documents.
2 documents required · 2 mandatory
₹350
Yes
₹3,753
Yes
25 Nov 2026
25 Nov 2026
5 Dec 2026
25 Nov 2026
5 Dec 2026
25 Nov 2026
60 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing and installation of suitable Submersible pumpset (water field) of standard make such as Kirlosker/KSB/Crompton/Sabar/all approved make confirming to ISI Code 8034-1976 with up to date ammenments. The Pump suitable for lifting water 234.00 metre head with (+) 10% and (-) 25% head range, Single phase AC supply Motor type UMAI (S) 100 suitable for operation on 220 (+/-) 5% volts 50 cycles / second single phase AC electric supply. The discharge of pump should be 1.30 litre/Sec. at duty point complete as per the satisfaction of Engineer-in-charge with in all leads and lifts. | 1 | Set | - | - |
| 1.01 | Discharge:- 1.30LPS | - | - | - | - |
| 1.02 | Total Head:- 234.00 meter | - | - | - | - |
| 2 | Providing and installation of PVC insulated copper conductor cable of Havells/all approved make of suitable size and suitable for motor offered under item no. 1 complete with flexible pipe and couplers from HPSEB meter to panel. Starter complete job, The type and size shall be subject to approval of electrical authorities and in case of its non acceptance the same shall be replaced free of cost by the tenderer complete in all respect with in all leads and lifts and to entire satisfaction of engineer -in -charge | 30 | Rmt | - | - |
| 3 | Providing supplying and installation of control panel with required accessories for motor offered above and having protection of motor on occurance of faults { Triping on occurance of fault(s) i.e. Moisture, high motor temperature, dry running, reverse rotation, Single phasing, voltage imbalance, overload and short circuit } and indication thereof by glowing fault lamp ; for motors above 15 KW another protection of Mechanical seal failure shall also be provided in addition to above protections complete in all respect with in all leads and lifts and to entire satisfaction of engineer -in -charge | 1 | Set | - | - |
| 4 | Erection Charges including labour charges, electrical connection , lowering of etc complete in all respect as per the entire satisfaction of Engineer-in-charge. | 1 | Job | - | - |
| 5 | Excavation in foundations, trenches etc., in earth work lift upto 1.50 Metres stacking the eacavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15cm. layers, when required in to plinths sides of foundations etc., consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed with in a lead of 20 metres to the entire staisfaction of Engineer-in-charge with in all leads and lifts. | 60 | Cum. | - | - |
| 6Laying, jointing (by way of circumfrential butt welded joints by electrical arc welding) and testing of G.I. pipe of following dia meters confirming to IS1239-2001(latest with upto date amendments) having wall thickness as specified below with bevelled/plain ends in a random length of 4 to 7 meters, including manufacturing reducers/tapers, all short pieces, bends etc. as per site requirements made from parent tubes. The laying of pipe will include all operation such as cutting, welding and jointing, fabrication of bends, tees, etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The damaged portion of the pipes and specials made from the parent tube during welding or otherwise shall be provided anticorrisive treatment by applying two coats of anticorrosive bituminous paints over a priming coat as per AWWA specifications C-203-1978. The welding electrods shall be as per IS 814 of Advani Oerlikon/L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfation & direction of Engineer in charge with in all leads and lifts(Earth work in trenches will be measured and paid for separately) (Labour rate) | |||||
| 6.01 | 50mm dia WT 3.60 (M) | 95 | Rmt. | - | - |
| 7Laying, jointing and testing in trenches to be levelled to grades, GI flanged pipes of following diameter confirming to IS:1239-2001( Part-II) having minimum wall thickness as per IS code and class of pipes specified below, provided and jointed with flanges conforming to tables as specified below of BIS 6392-1971 welded at both ends according to relevant BIS standards and detailed specifications and provided with nut & bolts of required sizes, 3mm thick compressed asbestos fiber jointing gasket / synthetic rubber gasket confirming to relevant BIS codes including all kinds of flanged short pieces, bends, tees & other specials etc made from parent tubes & welded with flanges of tables as applicable for the particular reach as per site conditions including flushing, cleaning & hydraulic testing as per directions of Engineer-in-charge. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.42 MB
BOQ_222447.xls
BOQ • 0.29 MB
PWD8.pdf
Tender Documents • 0.84 MB
PWD6.pdf
Tender Documents • 0.23 MB
tc.pdf
Tender Documents • 0.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .