Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC | ₹4.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹4.9 LRejected-Finance VILL P O KALINAGAR SOUTH 24 PARGANAS PIN 743610 | KALINAGAR | SOUTH 24 PARGANAS | WEST BENGAL | 743610 | ₹4.9 L | L2 | Rejected-Finance L2 |
| 3 | L3₹5.3 LRejected-Finance | ₹5.3 L | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | KAUSHIK ENTERPRISE L1 | S.S. ELECTRICAL ENTERPRISE L3 | B.S. ELECTRICAL L2 |
|---|---|---|---|---|---|---|
| 1.00Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [D-9, D-10/13] | ||||||
| 1.01 | 2+6 way Enclosure [Make:Siemens Enclosure (8GB32102RC08) or equivalent model of L&T/ABB/Legrand/Crabtree as approved by E.I.C] [D-9/13] | 2 | nos | 1,320 ₹2,640 | 1,390 ₹2,780 | 1,337 ₹2,674 |
| 2.00Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand /Siemens/ Crabtree/L&T as approved by E.I.C) [D-5/6] | ||||||
| 2.01 | 40 Amp DP Isolator | 2 | Nos | 330 ₹660 | 400 ₹800 | 358 ₹716 |
| 3.00Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make: Legrand /Siemens/ Crabtree/L&T as approved by E.I.C) [D-6/7] | ||||||
| 3.01 | 6-32 Amps SP MCB | 12 | nos | 187 ₹2,244 | 220 ₹2,640 | 198 ₹2,376 |
| 4.00 | Supplying and fixing of 240V,32 Amp DP with fuse on L&N Sheet steel Main Switches on flat iron frame on wall. [Make:Havells/Standard/Anchor as per the choice of EIC] [D1:1a] | 2 | nos | 1,270 ₹2,540 | 1,300 ₹2,600 | 1,290 ₹2,580 |
| 5.00Supply of 4/3.5/2 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Havells/ Gloster /KEI /Polycab/Mescab cable as approved by E.I.C] | ||||||
| 5.01 | 4 core 16 sq.mm. | 80 | Mtr | 229 ₹18,320 | 280 ₹22,400 | 238 ₹19,040 |
| 5.02 | 2 core 16 sq.mm. | 120 | Mtr | 149 ₹17,880 | 198 ₹23,760 | 170 ₹20,400 |
Tender Value
Refer Docs
EMD Value
₹9,700
Closing Date
18 Feb 2026, 3:00 pmClosed
AE/KRESD/PWDte
Office of The Assistant Engineer, Kolkata Raj Bhavan Electrical Sub Division, P.W.Dte., 2 Larkin Lane, Kolkata-700062
Replacement of old wiring with additional electrical points and associated EI works at Main Building and associated compound of Barrackpore Flagstaff House including Rose Garden compound under Kolkata Raj Bhavan.
2026_WBPWD_1000529_1
WBPWD/AE-KRESD/NIQ-50/2025-26
Open Tender
ELECTRICAL WORKS M/R
45 days
Barrackpore Flagstaff House
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,700
15 May 2026
6 Feb 2026
20 Feb 2026
6 Feb 2026
18 Feb 2026
6 Feb 2026
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [D-9, D-10/13]
2+6 way Enclosure [Make:Siemens Enclosure (8GB32102RC08) or equivalent model of L&T/ABB/Legrand/Crabtree as approved by E.I.C] [D-9/13]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand /Siemens/ Crabtree/L&T as approved by E.I.C) [D-5/6]
40 Amp DP Isolator
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make: Legrand /Siemens/ Crabtree/L&T as approved by E.I.C) [D-6/7]
6-32 Amps SP MCB
Supplying and fixing of 240V,32 Amp DP with fuse on L&N Sheet steel Main Switches on flat iron frame on wall. [Make:Havells/Standard/Anchor as per the choice of EIC] [D1:1a]
Supply of 4/3.5/2 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Havells/ Gloster /KEI /Polycab/Mescab cable as approved by E.I.C]
4 core 16 sq.mm.
2 core 16 sq.mm.
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. [F-2/1(a)]
Laying of cable on wall/surfaceincl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
upto 2 core 25 sqmm. [F-1/2(a)]
upto 3/4 core 25 sqmm. [F-1/2(b)]
Supplying and fixing compression type gland and finishing the ends of following XLPE / PVC armoured AL. cable (2/4 / 3.5)Core as per GS. [F-4 & F-5]
i) 4 Core 16 Sq. mm [[7(c)/F4 & 8(b)(xii) /F5]]
i) 2 Core 16 Sq. mm [[7(a)/F4 & 8(b)(iv) /F5]]
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan /call bell points with Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA with choice of colour as approved by E.I.C) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
i) Average run 12 mtr [E-25/4(g)]
Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
25 mm dia 3 mm thick polythene pipe without earth continuity wire [E-2/4(a)]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
3 x 22/0.3 (1.5 sqmm) [E-9/1(b)]
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [E-9/C1(s)]
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [E-9/C1(v)]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-5/9]
i) 2.5sqmm [F-5/9(i)]
ii)10 sqmm [F-5/9(iv)]
Supply & Delivery of 250V, 70 Watt LED Street Light fittings having luminous efficacy- 110lm/W with die cast aluminium housing, heat resistant toughened glass cover & IP66 Protection [Philips/Crompton/ Wipro or manufacturer with own NABL accredited Lab with valid Test certificate as approved by E.I.C]
Supply & Delivery of 250V,250 Watt LED flood Light fittings having luminous efficacy- 110lm/W with die cast aluminium housing, heat resistant toughened glass cover & IP66 Protection [Philips/Crompton/ Wipro or manufacturer with own NABL accredited Lab with valid Test certificate as approved by E.I.C]
Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure. [C-3/20(a)]
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sq.mm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. [C-3/18]
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener. [C-2/14(b)]
Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length.[C-2/15]
Disconnection & dismantling existing old Electrical installation, Switch-board, wiring, SFU, Electrical fitting/fixtures etc with owns tools & takles incl. mending good damages as per GS and clearing/removing from the site.
Add. G.S.T.@ 18% on total value.
Add. LWC.@ 1% on total value
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.13 MB
2911_ii.pdf
Tender Documents • 0.50 MB
BOQ_2451354.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid