Loading…
Loading…
Tender Value
₹2.7 Cr
EMD Value
₹2.8 L
Closing Date
22 Apr 2026, 6:00 pmClosed
Deputy Municipal Commissioner
Construction of New Community Hall at T. P. Scheme no. 47 (Bhestan), F. P. 18, Bhestan Gam in South Zone-A (Udhana), Surat.
295383
DMC/SZ-A/20/2025-26 ,WORK NO. 07
Open
Civil Works
Surat
3 documents required · 3 mandatory
₹4,248
Commissioner, Surat Municipal Corporation
₹2.8 L
8 Apr 2026
8 Apr 2026
8 Apr 2026
22 Apr 2026
8 Apr 2026
Schedule - B SOR 2024-25
Sr. No. Description Qty. Rate Unit
Work up to Plinth Level
Excavation for foundation includ.sorting out &
stacking of useful materials & disposing of the
1 excavated stuff upto 50 mt. Lead & all lift, watering
(A) Loose or Soft soil Executed With Mechanised
Efforts / Machinaries
Boring holes 3.5 mt.deep in ordinary soil ( for cast in
situ piles) & disposal of the surplus excavated soil as
2 directed within a lead of 50 M. For following diameter
250mm dia 63.00 334.80 Rmt
Providing and filling rubbles including hand packing
3 and filling interstices with quarry spalls behind 113.00 1,094.11 C.M.
abutments and between returns as directed.
Providing & laying C.C 1:3:6 (1cement :3 coarse sand
:6 Crushed stone agg 20m.m Nominal size)&curing
comp. excl. cost of form work in :(a) foundation &
(A) Foundation 63.00 3,095.25 C.M.
(C) Grade Slab 60.00 3,095.25 C.M.
Providing & laying cement concrete 1:2:4 (1
cement:2 sand:4 graded stone agg. 20 mm nominal
size)& curing comp. Includ.cost of form work but
exclu. Cost of reinforcement for reinforced concrete
work in : (A) Foundation, footing, Base of columns
and Mass concrete
(C) Grade slab 60.00 3,741.69 C.M.
Sr. No. Description Qty. Rate Unit
Providing, mixing, placing, compacting by machine
vibrator, curing, testing M25 Design mix concrete as
6 per IS 456:2000 (latest revision) and as per tender
specification in all items including cost of form work
and rendering but excluding cost of reinforcement
(A) foundation, footing, base of columns and mass
Providing, mixing, placing, compacting by machine
vibrator, curing, testing M25 Design mix concrete as
7 per IS 456:2000 (latest revision) and as per tender
specification in all items including cost of form work
and rendering but excluding cost of reinforcement
(1) Having cross sectional area up to 0.085sq.mt. 0.00 12,930.68 C.M. -
(2) Having cross sectional area more than 0.085 sqmt
& up to 0.12 sqmt.
(3) Having cross sectional area more than 0.12 sq. mt. 22.00 9,288.03 C.M.
(1)Having cross sectional area upto 0.08 sq.mt. 0.00 9,083.57 C.M. -
(2)Having cros sectional area more than 0.08 sqmt and
upto 0.12 sqmt.
(3) Having cross sectional area more than 0.12 sq. mt . 48.50 7,067.84 C.M.
Providing, mixing, placing, compacting by machine
vibrator, curing, testing M35 Design mix concrete as
8 per IS 456:2000 (latest revision) and as per tender
specification in all items including cost of form work
and rendering but excluding cost of reinforcement
(1) Having cross sectional area up to 0.085sq.mt. 0.00 13,194.99 C.M. -
(2) Having cross sectional area more than 0.085 sqmt
& up to 0.12 sqmt.
(3) Having cross sectional area more than 0.12 sq. mt. 19.00 9,552.35 C.M.
(1)Having cross sectional area upto 0.08 sq.mt. 0.00 9,347.88 C.M. -
(2)Having cros sectional area more than 0.08 sqmt and
upto 0.12 sqmt.
(3) Having cross sectional area more than 0.12 sq. mt . 37.50 7,332.16 C.M.
Sr. No. Description Qty. Rate Unit
Providing & laying C.C 1:3:6 (1cement :3 coarse sand
9 :6 crushed stone agg. 20 m.m Nominal size)& curing
comp. incl. cost of from work in: wall caps/ copings.
Providing & fixing IS Mark TMT Bar FE 500D
10 reinforcement for R.C.C. work incl. bending, binding
& placing in position etc.comp.
Upto G.L./P.L. 30695.00 77.29 Kg.
Brick work using common burnt clay building bricks
having crushing strength not less than 35 kg./Sq.Cm.
in Cement Mortar 1:6 (1- Cement : 6 -fine sand) (C)
Filling available excavated earth (excluding rock) in
trenches. plinth, sides of foundations etc. in layers not
exceeding 20 cm. in depth consolidating each
disposited layer by ramming and watering.
Filling in foundation and plinth with murrum or
13 selected soil in layers of 20cm. thickness including 631.00 301.78 C.M.
watering, ramming and consolidating etc. complete.
Carring out plinth treatment to post construction /
existing structure by spraying chemical solution for
termite control treatment including labour and
material consistment with ISI specification. Using
Chlordene and Chiorpurfiles 20 EC. As per
6131_paret-II Consentration Weight one percent is
recommended i.e. one litre 20 EC chemical emulsion
with 19 liter give 1% concrentration inclusive of one
litre chemical emulsion appication at the rate of 5 litre
chemical / Sqm of surface is recommended as per IS.
Providing & Applying 20mm. Th. Heavy Roller
plaster on walls or similar surfaces at all floor levels
consisting of 12 mm av. Th. Backing coat of C.M.
1:3 (1 cement:3 sand) & 8 mm. th. Finishing coat of
C.M. 1:1 (1 cement: 1 sand) apply thick cement slurry
and apply roller horizontal as well as vartical ( two
times ) up to good quality and size of grain in
elevation as per directed by engineer incharge.
Sr. No. Description Qty. Rate Unit
Providing & applying two coats of weather shield
max paint (3 coats may be required in case of darker
colours.) of ICI Dulux or Apex Ultima of Asian Paint
including applying exterior acrylic primer coat as per
manufacturers specification and directions in shade
and colour approved by architects, on exterior surfaces
of the building including scaffolding, preparing the
surface, watering, curing etc. complete and as directed
by the architects and manufacturers. Surface
Preparation : surface is thoroughly clean, dry and free
from all loose dirt, chalk, grease, fungi, algae and
16 flaking paint. This can be achieved by brushing with a 107.00 82.00 S.M
wire/ stiff coir brush, followed by water jetting if
required. Fill up all minor cracks and defects with
white cement and sand mixture in the ratio 1:3. For
application on previously painted wall, previous
coatings of paint must be thoroughly scraped off and
Clean the surface thoroughly using wire brushes.
Priming: Apply a liberal coat of exterior acrylic primer
and allow it to dry for 4-5 hours. Application of putty
is not recommended. Minimum 4-6 hours duration is
required between each coat of weather shield max
Work Above Plinth
Providing, mixing, placing, compacting by machine
vibrator, curing, testing M25 Design mix concrete as
17 per IS 456:2000 (latest revision) and as per tender
specification in all items including cost of form work
and rendering but excluding cost of reinforcement
(1) Having cross sectional area up to 0.085sq.mt.
Ground Floor 0.00 12,930.68 C.M. -
Terrace Floor 0.00 12,971.23 C.M. -
(2) Having cross sectional area more than 0.085 sq. mt
.up to 0.12 sqmt.
Ground Floor 0.00 11,253.32 C.M. -
Terrace Floor 0.00 11,293.87 C.M. -
(3) Having cross sectional area more than 0.12 sq.mt.
Ground Floor 33.00 9,288.03 C.M.
Terrace Floor 11.00 9,328.58 C.M.
SC Floor 2.00 9,369.13 C.M.
(1) Having cross sectional area upto 0.08 sq.mt.
Ground Floor 0.00 9,083.57 C.M. -
Terrace Floor 0.00 9,124.12 C.M. -
(2) Having cros sectional area more than 0.08 sq. mt
and upto 0.12 sq.mt.
Sr. No. Description Qty. Rate Unit
Ground Floor 0.00 8,155.37 C.M. -
Terrace Floor 0.00 8,195.92 C.M. -
(3) Having cross sectional area more than 0.12 sq.mt.
Ground Floor 43.00 7,067.84 C.M.
Terrace Floor 5.00 7,108.39 C.M.
(2) Slabs having more than 8 Cm & upto 10 Cm
Ground Floor ( 1ST SLAB ) 0.00 7,965.38 C.M. -
SC Floor (2nd Slab) 0.00 8,005.93 C.M. -
(3) Slabs having more than 10 Cm & upto 13 Cm
Ground Floor ( 1ST SLAB ) 0.00 7,377.92 C.M. -
SC Floor (2nd Slab) 0.00 7,418.47 C.M. -
(4) Having more than 13 cm. Thickness
Ground Floor ( 1ST SLAB ) 65.00 6,793.97 C.M.
SC Floor (2nd Slab) 5.00 6,834.52 C.M.
Ground Floor ( 1ST SLAB ) 16.00 9,963.33 C.M.
SC Floor (2nd Slab) 3.00 10,003.88 C.M.
Ground Floor ( 1ST SLAB ) 2.00 7,119.46 C.M.
SC Floor (2nd Slab) 3.00 7,160.01 C.M.
Providing, mixing, placing, compacting by machine
vibrator, curing, testing M35 Design mix concrete as
18 per IS 456:2000 (latest revision) and as per tender
specification in all items including cost of form work
and rendering but excluding cost of reinforcement
(1) Having cross sectional area up to 0.085sq.mt.
Ground Floor 0.00 13,194.99 C.M. -
Terrace Floor 0.00 13,235.54 C.M. -
(2) Having cross sectional area more than 0.085 sq. mt
Ground Floor 0.00 11,517.64 C.M. -
Terrace Floor 0.00 11,558.19 C.M. -
(3) Having cross sectional area more than 0.12 sq.mt.
Ground Floor 31.00 9,552.35 C.M.
Terrace Floor 10.00 9,592.90 C.M.
(1) Having cross sectional area upto 0.08 sq.mt.
Ground Floor 0.00 9,347.88 C.M. -
Terrace Floor 0.00 9,388.43 C.M. -
(2) Having cros sectional area more than 0.08 sq. mt
Sr. No. Description Qty. Rate Unit
Ground Floor 0.00 8,419.68 C.M. -
Terrace Floor 0.00 8,460.23 C.M. -
(3) Having cross sectional area more than 0.12 sq.mt.
Ground Floor 61.00 7,332.16 C.M.
Terrace Floor 0.00 7,372.71 C.M. -
(2) Slabs having more than 8 Cm & upto 10 Cm
Ground Floor ( 1st SLAB ) 0.00 8,229.69 C.M. -
SC Floor (2nd Slab) 0.00 8,270.24 C.M. -
(3) Slabs having more than 10 Cm & upto 13 Cm
Ground Floor ( 1ST SLAB ) 0.00 7,642.24 C.M. -
SC Floor (2nd Slab) 0.00 7,682.79 C.M. -
(4) Having more than 13 cm. Thickness
Ground Floor ( 1ST SLAB ) 55.00 7,058.28 C.M.
SC Floor (2nd Slab) 0.00 7,098.83 C.M. -
Designing, providing and executing Bonded/
Unbonded Post-tensioning works for slabs/beams/drop
panels, etc. Including decoiling the strands, cutting to
the required lengths, supplying and laying of sheathing
(GI corrugated ducts), jointing with couplers and
inserting the strands, profiling, fixing live anchorages
suitable for tendons, grout vents, making dead end
anchorages including lowering the strands, fixing
tendon support bars, supervising the fixing of anti-
bursting reinforcement, stressing the cables, end
trimming, grouting the cables with cement and
admixtures, with required plants and machinery tools
and tackles, consumables etc. including co-ordinating
with Architectural/Structural consultants drawings and
19 obtaining approval from client/consultant/Project 6450.00 180.00 Rmt.
Manager for the work done as per the requirement of
Architect/Structural Consultant at site. Also include
Area marking for Post tensioned elements. Area for
the same shall be measured within peripheral RCC
beams/walls (Walls/beams not included) or boundary
of the slab etc. including all requisite as per Structural
Engineer instructions.Including all PT memberes (slab
& beam) stagging, shuttering and reproping shall be
carried out as per structural engineer's instruction and
suggestion.(1) All Post Tensioned Beams Detail Shall
Only Be Provided After Finalization Of Pt Vender By
Contractor. (2) Rates Of PT beams Includes All
Ancillary Work/Facility/Item To Be Carried Out By
Contractor For Successful Execution Of PT Work. (3)
Sr. No. Description Qty. Rate Unit
Providing, mixing, placing, compacting by machine
vibrator, curing, testing M20 Design mix concrete as
per IS 456:2000 (latest revision) and as per tender
specification in all items including cost of form work
and rendering but excluding cost of reinforcement
wall caps/ copings.
Ground Floor ( 1ST SLAB ) 4.66 9,928.51 C.M.
Second Floor (2nd Slab) 5.00 9,969.06 C.M.
Stair cabin top 2.00 10,009.61 C.M.
Providing, mixing, placing, compacting by machine
vibrator, curing, testing M25 Design mix concrete as
21 per IS 456:2000 (latest revision) and as per tender
specification in all items including cost of form work
and rendering but excluding cost of reinforcement
(F) Stair cases including landing etc.
GROUND FLOOR (1 no. of staircase) 7.00 7,765.80 C.M.
(B) Vertical and horizontal fins
Ground Floor ( 1ST SLAB ) 0.00 9,483.21 C.M. -
First Floor (2nd Slab) 0.00 9,523.76 C.M. -
Providing & fixing IS Mark TMT Bar FE 500D
22 reinforcement for R.C.C. work incl. bending, binding
& placing in position etc.comp.---
Ground Floor ( 1ST SLAB ) 47867.00 77.29 Kg
First Floor (2nd Slab) 9110.00 78.34 Kg
Above SC Slab 820.00 79.39 Kg
Brick work using common burnt clay building bricks
having crushing strength not less than 35 kg./Sq.Cm.
in Cement Mortar 1:6 (1- Cement : 6 -fine sand) (C)
Ground Floor ( 1ST SLAB ) 235.00 4,729.83 C.M.
First Floor (2nd Slab) 64.00 5,018.55 C.M.
Above SC Slab 14.00 5,307.27 C.M.
Half brick masonry in common brunt clay building
bricks having crushing strength not less than
24 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -
coarse sand ) in foundation and plinth (C)Fly Ash
Ground Floor ( 1ST SLAB ) 313.00 712.81 S.M.
Terrace Floor (2nd Slab) 0.00 719.37 S.M. -
Sr. No. Description Qty. Rate Unit
Providing & Applying 15mm.th.cement plaster in
single coat on brick/concrete walls similar surfaces
for plastering & finished even & smooth with a
25 floating coat of cement slurry mixed with admixture of
lime or neeru in required proportion etc. comp. in C.M
1:3 (1 cement : 3sand) (A) For wall and similar
Ground Floor ( 1ST SLAB ) 1850.00 249.39 S.M
Terrace Floor (2nd Slab) 87.00 277.53 S.M
Providing & Applying 10mm.th.cement plaster in
single coat on brick/ concrete walls similar surfaces
for plastering & finished even & smooth with a
26 floating coat of cement slurry mixed with admixture of
lime or neeru in required proportion etc. comp. in
C.M 1:3 (1 cement : 3sand) (A) For wall and similar
(B) for ceilings and soffits of stairs
Ground Floor ( 1ST SLAB ) 731.00 225.34 S.M
Terrace Floor (2nd Slab) 31.00 254.89 S.M
Providing and fixing 150 mm wide, approved
quality chicken wire mesh (FRP / PVC)at junction
of brick work and RCC work or two dissimilar
surfaces, at all heights fixed by nails, rowal plugs or
tag by cement mortar 1:3 before applying the plaster,
including curing, scaffolding all complete as directed.
Ground Floor ( 1ST SLAB ) 130.00 102.00 S.M.
Terrace Floor (2nd Slab) 6.00 102.00 S.M.
Providing & Applying 20mm. Th. Heavy Roller
plaster on walls or similar surfaces at all floor levels
consisting of 12 mm av. Th. Backing coat of C.M.
1:3 (1 cement:3 sand) & 8 mm. th. Finishing coat of
C.M. 1:1 (1 cement: 1 sand) apply thick cement slurry
and apply roller horizontal as well as vartical ( two
times ) up to good quality and size of grain in
elevation as per directed by engineer incharge.
Ground Floor ( 1ST SLAB ) 681.00 324.00 S.M
Terrace Floor (2nd Slab) 471.00 324.00 S.M
Above SC Slab 73.00 324.00 S.M
Providing throating or plaster drip and moulding it
to R.C.C. chajja etc. comp.. For all floor
Ground Floor ( 1ST SLAB ) 107.50 43.74 R.M
Terrace Floor (2nd Slab) 4.50 43.74 R.M
Sr. No. Description Qty. Rate Unit
Providing 20 mm deep finished groove in plaster in
line and level etc. Comp. For all Floor (M.R.)
Ground Floor ( 1ST SLAB ) 107.50 50.00 R.M
Terrace Floor (2nd Slab) 4.50 50.00 R.M
Providing and laying Vitrified tiles 8 to 10 mm thick,
24" x 24" in flooring treads of steps and landing
31 laid on a bed of 12mm thick cement mortar 1:3 (1
cement : 3 coarse sand) finishing with flush pointing
in white cement.
Ground Floor ( 1ST SLAB ) 134.00 1,092.37 S.M
Terrace Floor (2nd Slab) 0.00 1,092.37 S.M -
Providing and laying Vitrified tiles 8 to 10 mm thick,
24" x 24" in skrting risers of steps and dedo on
10mm thick cement plaster 1:3 (1 cement : 3 coarse
sand) and jointed with white cement slurry.
Ground Floor ( 1ST SLAB ) 433.00 1,135.80 S.M
Terrace Floor (2nd Slab) 0.00 1,135.80 S.M -
Providing & laying Vitrified tiles of 8mm thick of
Orient, Kajaria, Jhonson, Nitco, Somani, Bell, Asian
or Euro make in flooring,treads of steps & Landing
laid on bed of 20 mm (Average) base of cement
mortar 1:6 (1 Cement : 6 Coarse sand) on new
surface or fixing on existing flooring by adhesive
material including dismentaling of existing flooring
and jointed with colour cement slurry including
finished with flush pointing & cleaning the surface etc.
comp.Size 24" x 24" For Antiskid tiles
Ground Floor 28.50 1,467.72 S.M
Providing and laying polished Kota stone slab
flooring over 20mm (Average) thick base of cement
mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5
34 (1-Lime putty :1.5 - coarse sand) laid over and jointed
with grey cement slurry mixed with pigment to match
the shade of slab including rubbing and polishing etc.
complete. (A) 25mm thick
Ground Floor 498.00 1,019.39 S.M
Sr. No. Description Qty. Rate Unit
Providing and laying polished kota stone slab 25mm
thick in risers of steps,skirting Dedo and pillars
laid on 10mm thick cement mortar 1:3 (1- Cement :
3 coarse sand) and jointed with gray cement slury
mixed with pigment to match the shade of slab
including rubbing and polishing etc. complete.
Ground Floor 30.00 1,130.79 S.M
Providing and constructing sandwitch type Granite
stone cooking platform 0.6 mt. wide & 0.75 mt.
height, including one end side granite stone
(Double Polish) of 1.25 mt. height & front granite
stone patti of 10 cm wide, vertical partitions of half
B.M. wall in C.M. 1:4 and 10mm th. plaster in 1:3
with finishing smooth with cement slurry as required
and Stainless Steel sink of 0.45 mt x 0.45 mt size of
approved quality and make with required all fitings &
fixitures etc. comp as per instruction given by site in
charge at all floors. (Basic rate of Granite Rs.1,200.00
ALL FLOOR 25.00 3,128.00 R.M.
Providing and filling in depressions of Bath and
W.C. At all floor levels, after completing plumbing
work of pans, pipes,traps etc.with cinder or fly ash as
directed by Engineer in charge etc. comp..
All Floor 14.00 500.00 S.M
Providing & fixing 35mm.th. Indian teak wood
shutters for doors, windows & clearstory windows
incl. Indian teak wood frames of finished size 12cm
x 7cm.incl. anodized aluminum fixtures & fastenings
incl. Primer coat of approved quality & two coats of
oil painting etc. For all Floor
All Floor 24.00 5,533.68 S.M
Sr. No. Description Qty. Rate Unit
Providing and fixing FRP FRAME size 125 x 65 mm
and 35 mm thick FRP shutter with wood grain
raised panneled design finish shutter having extra
reinforcement on sides & edges in Gel coat finish. The
core of the shutter & frame is to be filed up with
injected polyurethene foam done in situ along with
embedded wooden pieces for stiffening & also taking
hinges & fixtures. The whole FRP frame & shutter
is to be water proof weather proof,termite proof
&resistance to mild acid/alkali. Rates are to be
inclusive of S.S.hinges with fastener sleeve &
alluminium fixtures & fastentings.
Providing & fixing 35mm.th. Flush Door Solid
Double Core type Both Face water proof Ply
Vennered & 1.5 mm th.laminate shall be pasted on
both side with adhesives as specified by the
40 manufacturers. The laminate shall be as per approved 0.00 3,720.00 S.M -
shade & texture, of make incl. Sal wood frames of
finished size 12cm x 7cm.incl. S.S. Hinges with
nessary screws & Anodized aluminum fixtures &
fastenings For all Floor
Same as Above But Without Frame
All Floor 39.00 2,520.00 S.M
Providing and fixing window having extruded
aluminium Powder Coated section frame main
outer size 63.50 x 38.10 x1.95 mm (of Jindal section
no.4605, @ Wt. 1.094Kg/mt) horizontal Two track
member size 61.85 mm x 31.75 mm x 1.20 mm (of
jindal section no:8687, @ Wt. 0.695 Kg/mt.) vertical
member of size 61.85 mm x 31.75 mm x 130 mm (of
jindal section no:8758 @ wt. of 0.659 kg/mt) with
41 sliding shutters of horizontal member size 40 mm x18
mm x 1.29 mm ( of jindal section no:8949, @ Wt. of
.456 Kg/mt) vertical member of size 40 mm x 18 mm
x 1.29 mm (of jindal section no:8947, @ Wt. of
Kg/mt/section 8948, @ Wt. of 0.457 Kg/mt) with
mm thick tranparent bronze colour tineted float glass
with powder coated aluminium fittings and fixtures
and transparent silicon sealant glass fixing to frame as
per details etc. complete for window.
(A) Same as above but colour anodized 25.00 1,705.67 S.M
Sr. No. Description Qty. Rate Unit
Providing and fixing window having extruded
aluminium Powder Coated section frame main
outer size 95 mm x 24 mm x 1.17 mm (of jindal
section no:2459 @ Wt. of 0.738 Kg/mt), horizontal
Three track member size 92 mm x 31.75 mm x
mm (of jindal section no;8688, @ Wt. 1.07 Kg/mt),
vertical member of size 92 mm x 31.75 mm x
mm (of jindal section no:8933, @ Wt. 1.06 Kg/mt)
with sliding shutters of horizontal member size 40 mm
x 18 mm x 1.29 mm (of jindal section no:8947 @ wt.
of 0.456 kg/mt), vertical member of size 40 mm x
mm x 1.29 mm (of jindal section no:8949 @ wt. of
0.456 kg/mt) with 5 mm thick transparent bronze
colour tinted float glass with powder coated
aluminium fittings & fixtures and transparent silicon
sealant glass fixing to frame as per details etc.
(A) Same as above but colour anodized
All Floor 33.00 1,591.87 S.M
Providing and fixing standared extruded of aluminium
section of size 61 x 37.0x0.90 mm (of Jindal section
no.14080, @ Wt. 0.471 Kg per mt) with colour
powder coated alluminium frame for Lovered Glass
ventilation with 5 mm thick Frosted glass as details
etc. complete for ventilation
All Floor 0.00 1,175.56 S.M -
A) Same as above but Colour anodized 5.50 1,175.56 S.M
Providing & laying granite slab 18mm thick in
Window-Door seal Frame Etc laid on 10mm thick
cement mortar 1:4 (1 Cement : 4 Coarse sand) with
nessary adhesive material and finished with flush
pointing in white or colour cement, including rubbing
& polishing comp.. (Basic Rate:- Rs.1000.0/S.M.)
For all Floors. 84.00 2,026.00 S.M
Labour Charges For Edge Finished For Granite for all
For all Floors. 808.00 43.43 R.M
Sr. No. Description Qty. Rate Unit
Providing & fixing Powder Coated Aluminium
partly glazed and partly panelled partition using
medium duty sections of Hindalco,Zindal, Narmada,
Banco or Equivalent approved make having section
63.50 mm x 38.10mm ( Frame-.758 kg/rmt & Middle
section- 0.819 Kg./rmt), Galzing Clip with 5 mm thick
clear float glass of approved make including all other
necessary fittings and fixtures. Entire work will have
to be made water proof using necessary rubber
sectioned wherever required. Gaps all round the frame
to be filled with approved water proof sealent. Bottom
portion of doors both side to be covered with 12mm
thick prelaminated particle board of approved make
and quality and as per design.
(A) Same as above but Colour anodized
For all Floors. 0.00 2,400.00 S.M -
Providing & fixing partly panel & partly glass
Powder Coated Aluminium doors with aluminium
section of Hindalco, Jindal , Narmada,Banco or
Equivalent approved make having Poder Coated outer
frame Leg Partition section of 63.50 mm x 38.10 mm
having weight 1.158 kg. / R.M. shutter section having
size 83.5 mm x 44.45mm ( top & bottom:
47 kg./rmt. and middle 1.139 kg./rmt.) door vertical
47.62mm x 44.45 mm ( vertical:0.881 kg./rmt. & top
hing side:0.974 kg./mt.), Glazing Clip (Jindal Section
No. 19370 Wt. 0.109 Kg./ Mt.) with 5mm thick sheet
glass in acid frogting and 12 mm thick prelaminated
sheet of Greenlam, Panama or archid make as
approved by Engineer-in-charge including fixing brass
pivot, handle, lock etc. complete.
(A) Same as above but Colour anodized
For all Floors. 0.00 3,237.00 S.M -
Providing & fixing M.S.Grills of required pattern to
wooden frames of windows etc. At all floor levels
with M.S. flats at required spacing & frame around
square or round bars with round headed bolts & round
headed bolts and nuts or by screws incl. Priming coat
of Red lead paint etc. comp.
(A) Plain grill For all Floors. 2955.00 109.41 Kg.
Sr. No. Description Qty. Rate Unit
Painting two coat (excluding priming coat) on new
steel and other metal surface with synthetic enemal
49 paint, burshing to give an even shade including
cleaning the surface of all dirt, dust and other foreign
For all Floors 148.00 68.57 S.M
Providing and fixing stainless steel ( Grade 304)
railing made of Hollow tubes, channels, plates etc.,
including welding, grinding, buffing, polishing and
making curvature (wherever required) and fitting the
same with necessary stainless steel nuts and bolts
complete, i/c fixing the railing with necessary
50 accessories & stainless steel dash fasteners , stainless 379.00 450.00 Kg.
steel bolts etc., of required size, on the top of the floor
or the side of waist slab with suitable arrangement as
per approval of Engineer-incharge, (for payment
purpose only weight of stainless steel members shall
be considered excluding fixing accessories such as
nuts, bolts, fasteners etc.)
(1) The whole work is to be executed through
specialized agency with a guarantee of 10 (Ten) years
51 given on a prescribed proforma duly stamped (2) The
rate shall include for work at all floors & conducting
water proof test as directed. (M.R.)
B) Providing and laying integral cement based water
proofing treatment including preparation of surface as
required for treatment of roofs, balconies, terraces etc.
consisting of following operations. (a) Applying and
grouting a slurry coat of neat cement using
kg/sqm of cement admixed with proprietary water
proofing compound comforming to IS:2645 over the
R.C.C. slab including cleaning the surface before
tratment.(b) Laying cement concrete using broken
bricks/brick bats 25 mm to 100 mm size with 50% of
cement mortar 1:5 (1 Cement : 5 Coarse sand)
admixed with proprietary water proofing compound
conforming to IS:2645 ,brick bats is finally covered by
jointless cement plaster 20mm th. in C.M. 1:4 added
with special water proofing compound confirming to
IS:2645 & top smooth finished with trowel with false
chequered marking of 300 mm.size.The treatment is
carried along the vertical surface of the parapet &
other adjoining wall up to height of about 300 mm in a
shape of quarter round vata Incl. curing etc. Comp.
With average thickness of 120 mm and minimum
thickness at khurra as 65 mm.(c) The whole terrace so
finished shall be flooded with water for a minimum
period of two weeks for curing and for final test. All
Sr. No. Description Qty. Rate Unit
(c) The whole terrace so finished shall be flooded
with water for a minimum period of two weeks for
curing and for final test. All above operations to be
down in order and as directed and specified by the
engineer-in-charge. With average thickness of 120 mm
and minimum thickness at khurra as 65 mm. (Cement
consumption 0.511 Bags / S.M.)
Terrace and staircabin top 846.00 511.00 S.M
(A) Providing and laying water proofing treatment to
vertical and horizontal surfaces of depressed portions
of W.C.,kitchen and the like consisting of : (a) I course
of applying cement slurry @ 4.4 kg/sqm mixed with
water proofing compound conforming to IS : 2645 in
recommended proportions. (b) II course of a layer of
plaster in C.M. 1:3 with water proofing compound
confirming to IS:2645 about 25 mm. th' in the floor of
the depression & about 18mm th' On the side walls of
the depression up to the floor level, water proofing
plaster about 18 mm. th' be continued on the walls
above the floor level for a height of 600 mm. with
surface suitable to receive further treatment (c)
Finishing top with stone aggregate 10mm to 12mm
nominal size spreading @0.008 C.M./S.M.,
thoroughly embedad in plaster layer. as per
specifications & instructions of Engineer in charge
(Cement consumption 0.316 Bags / S.M.)
For all Floors 55.00 296.00 S.M
Providing and laying broken china mosaic flooring
for terrace using 12mm to 20mm broken pieces of
glazed tiles to be laid over cement mortar 1:3 to
plain or slope and to be tempered to bring mortar
creme out upto surface using white cement including
rounding off junctions and extending them upto 15 cm
along the wall clearing with water and oxalic acid etc.
Apply two coats of putty and two coats of primer of
approved brand and manufacture on new wall surface
53 to give an even shade including thoroughly brushing
the surface free from mortar dropping and other matter
and sand papered smooth.
(A) for wall and similar surfaces
For all Floors 1937.00 40.59 S.M
(B) for ceilings and soffits
Sr. No. Description Qty. Rate Unit
For all Floors 762.00 40.59 S.M
Wall painting (two coats) with plastic emulsion paint
of approved brand and manufacture on undecorated
54 wall surface to give an even shade including throughly
brushing the surface free from mortar droppings and
other foreign matter and sand papered smooth.
(A) for wall and similar surfaces
For all Floors 1937.00 83.36 S.M
(B) for ceilings and soffits
For all Floors 762.00 83.36 S.M
Providing & applying two coats of weather shield
max paint (3 coats may be required in case of darker
colours.)of ICI Dulux or Apex Ultima of Asian
Paint including applying exterior acrylic primer coat
as per manufacturers specification and directions in
shade and colour approved by architects, on exterior
surfaces of the building including scaffolding,
preparing the surface, watering, curing etc. complete
and as directed by the architects and manufacturers.
Surface Preparation : surface is thoroughly clean, dry
and free from all loose dirt, chalk, grease, fungi, algae
55 and flaking paint. This can be achieved by brushing
with a wire/ stiff coir brush, followed by water jetting
if required. Fill up all minor cracks and defects with
white cement and sand mixture in the ratio 1:3. For
application on previously painted wall, previous
coatings of paint must be thoroughly scraped off and
Clean the surface thoroughly using wire brushes.
Priming: Apply a liberal coat of exterior acrylic primer
and allow it to dry for 4-5 hours. Application of putty
is not recommended. Minimum 4-6 hours duration is
required between each coat of weather shield max
For all Floors 1225.00 82.00 S.M
Providing & laying granite slab 18mm thick in
flooring, treads of steps and landing laid on bed of
20mm thick cement mortar 1:6 (1 Cement : 6 coarse
56 sand) or lime mortar 1:1.5 laid and finished with flush
pointing in white or colour cement including rubbing
and polishing complete. (Basic Rate:-
For all Floors. 28.00 2,410.00 S.M
Sr. No. Description Qty. Rate Unit
Providing & laying granite slab 18mm thick in
skirting, risers of steps, dedo and pillars laid on
10mm thick cement mortar 1:4 (1 Cement : 4 Coarse
sand) and finished with flush pointing in white or
colour cement including rubbing & polishing comp..
(Basic Rate:- Rs.1347.46/S.M.)
Providing and fixing M.S. Fan clamps type 1 to
mm dia M.S. bar bent to shpe with hooked ends to
58 RCC slabs curing, layig including painting the
exposed portion of loops, all as per standard design
For all Floors. 34.00 135.47 Nos
Steel work welded in built up sections, framed work
59 including cutting, hoisting, fixing in position and
applying a priming coat of red lead paint
(A) in beams & joists channels angles, tees, flats with
connection plates or angle cleats as in main & cross
beams,hip & trussed purlins connected to common
raffers & the like.
For all Floors. 0.00 9,108.48 Qtl. -
Providing & fixing in position collapsible steel
shutters with vertical channels 20 x10 x 2 mm.
Braced with flat iron diagonals 20 x5mm size with top
60 & bottom rails of T-iron 40x40x6mm. with 38mm dia.
steel pulleys comp. with bolts, locking arrangements,
stoppers, handles incl. applying a priming coat of
Redlead paint etc. comp.
Ground Floor 36.00 6,158.35 S.M
Providing and fixing rolling shutters of approved
make made of 80 mm wide M.S. laths inter locked
together through their entire lenght and jointed
together at the ends by end locks mounted on specially
designed pipe shaft with bracket plates, guide channels
and arrangements for inside and outside locking with
push-pull operation including the cost of hood cover
and spring etc. complete.
(B) Shutters having width 3.5 M and above
Ground Floor 0.00 4,546.01 S.M -
Providing & fixing at all floor levels,both face
polished machine cut edge Marble slab for urinal
62 partition joined with grey/White cement slurry (1:1) 2.00 1,050.00 S.M
incl. Rubbing & polishing etc. complete. (M.R.)
(Basic Cost- Rs. 450/S.M.)
Sr. No. Description Qty. Rate Unit
63 Wall Vinyl Sticker 40.00 28.00 SqFt.
Eco Solvent Vinyl Sticker (120 gsm) with Lamination
Solvent Vinyl Sticker (120 gsm) with Lamination (100
66 5mm PVC sheet Eco Vinyl (Any size) 40.00 55.46 SqFt.
Decorative theme base designing & painting with all
waterproof materials
Designing, Approving, Providing and Supplying of
Flex Banner with MS (mild steel) Frame with
necessary welding, red oxide painting of support/
additional support if require including red oxide/ Anti
corrosive paint As per requirement & Direction of
Engineer in Charge
Any size 240 GSM ( Pipe Size 25x25x1.5mm) 100.00 53.10 SqFt.
Designing, Approving, Providing and Supplying of
Cloth Banner 140 GSM with MS (mild steel ) frame
with necessary welding,red oxide painting of
support/additional support if required including red
oxide/Anti corrossive paint As per requirement &
Direction of Engineer in Charge.
Upto 8 X 4 Feet 140 gsm ( Pipe Size 25x25x1.5mm) 100.00 65.00 SqFt.
Decorative wall painting with designing,Painting at
Place including necessary surface preparation,
cleaning, removal of dust & other foreign material and
back ground priming coat over the surface.
Slogan writing on walls with designing,Painting at
Place including necessary surface preparation,
cleaning, removal of dust & other foreign material and
back ground priming coat over the surface.
Providing, fixing, fitting S.S. Latter of quality SS
or with colour powder coating incliuding Necessary
fixture & Fastaning with scaffolding etc. complete. As
per requirement & Direction of Engineer in Charge.
Sr. No. Description Qty. Rate Unit
Providing, Approving designing computer Graphics
design, Echo solvent Vinyl printing, matt Lamination
pasting on 6mm PVC sheet, spot fitting with both side
4mm Tape & silicon etc. complete.
Providing, Approving designing and supplying 6mm
thick white Acrylic computer Laser cutting Latter
including necessary scaffolding, pasting on ACP sheet
or similar surfaces, etc. complete.
Designing, Approving, Providing and Supplying of
Fixing 3mm ACP sheet silver colour including
printing with graphic design in red & blue colour paint
75 latters / logo and brush finished and framing etc. 50.00 300.00 SqFt.
complete for inangration/ foundation stone takti with
decorative wooden/PVC moulding 2"x1" as per
approved by Engineer in charge.
Extra for additional height of propping and centering
where the height of propping and centering exceeds
76 .O M between supporting floor to ceiling including 719.00 390.34 Sqm
temporary brick or stone pillars for supporting as
required. (i)Height more than 4.0 M.and upto 5.0 M.
Extra for additional height of propping and centering
where the height of propping and centering exceeds
77 .O M between supporting floor to ceiling including 4.00 688.83 Sqm
temporary brick or stone pillars for supporting as
required. (ii) Height more than 5.0 M.and upto 6.0 M.
Water Supply & Sanitation
Prov.& Fixing water closet squatting pan (Orissa type
W.C.pan) at all floor levels, size 500mm x 400 mm
incl. 100 mm size "P'or "S" trap for water closet
78 squatting pan joining the trap with the pan & soil pipe
in C.M. 1:1 (1cement :1 fine sand) etc. Comp.(A)
Vitreous china long
Make- Cera S3010109, Jaquar, HindWare 20143 2.00 3,277.39 Nos.
Providing and fixing Wash Down Water closet
European type W.C. pan with integral P or S trap with
79 normal closing seat cover L bend ncluding jointing the
trap with soil pipe in cement mortar 1:1 (1 cement :
find sand) (A) Viterous china pattern - I
Sr. No. Description Qty. Rate Unit
Make- Cera CONVENTIONAL B1510121, HindWare
sleek 20011, Jaquar- CNS-WHT-751P180SPPZ
Providing and fixing plastic seat and cover for wash
80 down water closet with C.P. brass hinges and rubber
buffers (B) Plastic seat and cover.
For all Floors. 8.00 291.33 Nos
Providing & fixing Wash Hung basin with single
hole for pillar tap , Size- 550 x 400 mm at all floor
81 levels, with C.I. or M.S. Brackets painted white incl.
cutting holes & making good the same etc. complete.
Make- Cera Cat. No. S2040121, Jaquar SLS- WHT -
6801, HindWare10004
Providing & fixing 600 mm.x 450 mm. mirror of
superior glass at all floor levels, mounted on 6 mm.
82 th. A.C. sheet or plywood sheet & fixed to wooden
plugs with C.P.brass screws and washers etc. For all
All Floor 6.00 859.41 Nos
Providing & fixing C.P. brass pillar cock with copper
connection, C.P. brass screws complete
Make- Cera F2013101, HindWare Cat. No.: F650003,
Jaquar FLR-5011N
Providing & Fixing 15 mm Dia bib tap with wall
Flange at all floor levels, polished bright etc. comp
All floor 20.00 1,353.77 NO
Providing flush cock consisting lever, cartridge sleeve
& flange & concealed part
Make- Cera EXPOSED PART F2013751 &Concealed
part F4060101 , Jaquar FLR 5083 KN , CONCEALED
BODY ALD-081,HindWare F730013 &
CONCEALED STOP COCK F850095
Providing & fixing 15mm C.P. brass angle valve
(Stop Cock) with C.P. copper connecting pipe
86 mm long and nuts, washer and brass flange complete,
including cutting and making good the wall where
Make- Cera F1020362, HindWare Cat. No.: F440020
F850094, jaquar CON 053 KN
Sr. No. Description Qty. Rate Unit
Providing and fixing Towel Ring fabricated from
seamless stainless steel tube 2mm thick in bath room
with polished wall flange at end of bars with heavy
duty anchor fasteners & accessories.
Make- Cera F5014115CH, Jaqua ACN 1121N
,HindWare F880007
For all Floors. 8.00 924.24 Nos
Providing & Fixing stainless steel recessed type Soap
88 dish of approved make. Including providing & fixing
screws, washers, cutting & making good the walls.
Make- Cera F5007106, Jaquar ACN-1131N
,HindWare F880011
For all Floors. 8.00 839.91 Nos
Providing and fixing PVC SWR Nahni trap IS
for drain - 110x110 mm diameter with jali of the
89 following nominal diameter of self cleaning design
with C.I. scread down or hinged grating including the
cost of cutting and making good the walls.
All floor 15.00 586.27
Providing & Fixing U-PVC pipe (SWR) confirming
to IS no. 13592 (Type "B") of Prince/ Supreme/ Jain/
Astral/ Tulsi/ Finolex make for soil and waste
discharge system at all floor levels incl. All fixtures
like bends, tees, shoe etc. jointed with resin of
approved brand & manufacture etc. comp. (M.R.)
Providing & fixing U-PVC pipes Confirming to IS
no. 13592 (Type "A") of Prince/Supreme/Jain/Astral/
Tulsi/ Finolex make for rain water at all floor levels
incl. fixtures like bends, tees, shoe etc joined with
resin of approved brand & manufacture etc. comp.
Providing & Fixing in position PVC Cowl vent to
92 pipes of Prince/Supreme/Jain/Astral/Tulsi/Finolex
Sr. No. Description Qty. Rate Unit
Providing & Fixing Kathi around the vertical PVC
drainage pipes for concealing with cement plaster
mm avg thickness(CM 1:3 [1 cement :3 coarse sand])
finishing as per instruction given by Eng. incharge. for
(A) 75 mm PVC PIPE 20.00 173.00 R.M
(B) 100 mm /110 mm PVC PIPE 20.00 180.00 R.M
Providing, Laying and jointing on true line and level
UPVC pipe (SCH-40) line of Prince/ Supreme/
Jain/ Astral/ Tulsi/ Finolex make including fittings
make or equivalent as approved by angineer-in-charge.
94 Pipe shall be fixed on the wall the help of clamp at
every two meter C/C or shall be concealed as directed
including necessary fittings etc. including testing of
pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
Providing & Fixing P.V.C. pipes (SCH-80) of
Prince/ Supreme/ Jain/ Astral/ Tulsi/Finolex make
for water supply line at all floor levels incl. fixtures
like bends, tees, shoe etc joined with resin of approved
brand & manufacture etc. comp. Pipe shall be fixed on
the wall the help of clamp at every two meter C/C or
shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and
fixing the same with adhesive solvent, including cost
of all materials.
Providing and fixing M.S. holder bat clamps at all
floor level,of approved design to C.I. or S.C.I pipes
including cost of cutting holes and making good the
wall etc. comp. (M.R)
Providing & fixing Z - clamps at all floor levels of
97 approved design to C.I. S.C.I. or PVC pipes including
the cost of cutting holes & making good the wall etc.
Sr. No. Description Qty. Rate Unit
(C) 150 mm to 200 mm dia 20.00 98.00 NO
Providing & Fixing gun metal check or non return
98 full way wheel valve at all floors levels, etc.
Providing & Fixing abonite ball cock of approved
qualities directed etc. comp.
Providing, Lowering & laying joining R.C.C. NP2
CLASS Pipe In C.M. 1:1 of following nominal
internal diameters incl. Testing of pipes and joints etc.
Prov. & Fixing S.W. Gully trap with C.I.grating brick
masonary (C.M 1:5)chamber & water tight C.I. cover
with frame of 300mmx300mm size (inside) with
weight includ. plastering smooth inside & outside
15mm. th' in C.M.1:3 etc. comp. (i) Square mouth
traps---(A) 100mm x 100mm Size -P type
Prov. & Fix. 10 cm.x15 cm.(4" x 6") S.W. trap with
Inside dimension ,455 x 610 mm & 450 mm deep
sewer trap chamber with 23 cm th' B.B. masonary
walls in C.M 1:5 with cement plaster 15 mm th' in
102 C.M. 1:3 inside & outside to exposed faces, R.C.C. top 0.00 3,166.77 No. -
slab with 1:2:4 mix ( 1 cement: 2 Sand : 4 Grade stone
aggregate 20mm size) ,Foundation concrete 1:5:10 &
fixing C.I. cover with frame to be not less than 38 kg.
On top etc. comp. for single pipe.
(A).Same as above but Precast RCC heavy duty Cover
instead of C.I. Cover
Extra for every additional depth of 0.1 mt.beyond
Sr. No. Description Qty. Rate Unit
Providing & construction simple chamber of 23 cm.
th' B.B. Masonary in C.M 1:5 with cement plaster
mm th' in C.M. 1:3 inside & outside to exposed faces,
R.C.C. top slab with 1:2:4 mix ( 1 cement: 2 Sand :
103 Grade stone aggregate 20mm size) ,Foundation 0.00 2,932.93 No. -
concrete 1:5:10 & fixing C.I. cover with frame to be
not less than 38 kg. On top etc. comp. Inside
dimension,455 x 610 mm &450 mm deep for single
(A).Same as above but Precast RCC heavy duty Cover
instead of C.I. Cover
Extra for every additional depth of 0.1 mt.beyond
Providing and fixing C.I. manhole cover 0.60 mt. x
104 0.45 mt. size having weight not less than 35 kg. etc. 5.00 958.17 NO
Providing and fixing G.I, Rain water spout of 50 mm
dia and 30 cm Length
Providing & fixing white vitreous china urinal of size
450 x325mm as per IS-2556 (Part-2 ) with C.I.
hangers and 15mm dia. C.P. spreader,32mm dia CP
bottle trap and pipe to wall with C.P. flange complete
including cutting and making good the walls and
floors wherever required.
Make- CeraCat. No. S4020103, Jaquar URS-
WHT 13261H ,HindWare BACK SMALL
Providing & fixing at all floor levels,both face
polished machine cut edge Marble slab for urinal
107 partition joined with grey/White cement slurry 3.00 1,050.00 S.M
(1:1) incl. Rubbing & polishing etc. complete. (M.R.)(
Basic Cost- Rs. 450/S.M.)
Sr. No. Description Qty. Rate Unit
Providing & laying ordinary C.C.1:1.5:3 mix for
R.C.C. work incl. boxing, centering, vibrating, curing
& mixed with approved water proofing cement
compound or "CEMWET"or"PIDICRETE
LW"integral water proofing admixture as water
proofing agent to be mixed with 50 kg. cement bag
shall be as recommended by the manufacture of the
water proofing material, concrete work for top, bottom
slab & side pardi for Under ground Tank & Item incl.
Necessary excavation & refilling the available earth,
15 cm th' C.C 1:4:8 for bedding concrete, Half B.M. in
C.M. 1:4 outside wall, inside R.C.C. pardi as per
design, 10mm.th. water proofing cement plaster in
C.M. 1:3 with smooth finishing,watering etc.Comp.to
all inner face & bottom of tank curing etc. comp. incl.
Locking arrangement, outlet, inlet, overflow & wash
out pipe arrangement as necessary & C.I. Cover 0.60 x
.045 weight not less then 35kg. etc. com. as per
structural drawing excluding Steel & as directed by
Engineer in-charge
Under Ground water Tank 100000.00 6.87 Lit
Providing & Laying white glazed tiles 6mm. th. of
Orient, Kajaria, Jhonson,Nitco,Somani ,Bell make at
all floor levels, in flooring, treads of steps &
landings laid on a bed of 12 mm. Av.
Th.C.M.1:3(1cement :3 sand) finished with flush
pointing in white cement etc.com. For all floors
Under Ground water Tank 53.50 900.29 SM
Providing & Laying white glazed tiles 6mm. th. Of
Orient, Kajaria, Jhonson,Nitco,Somani,Bell make at
all floor levels in skirting risers of steps & dado on
mm. th. C.M.1:3(1cement :3 sand) including necessary
cement paste for fixing and joined with white cement
slurry etc. complete. For all floors
Under Ground water Tank 114.00 932.02 SM
SMC SOR, Page no4, It No.35
Providing & fixing IS Mark TMT Bar FE 500D
111 reinforcement for R.C.C. work incl. bending, binding
& placing in position etc. comp. Upto G.L./P.L.
Upto G.L./P.L. 3680.00 77.29 Kg.
Providing erecting and fixing double coated Sintex /
Super / Reno PVC (ISI) mark water tank of required
capacity each with all necessary fittings & connection
etc. complete on terrace.
Sr. No. Description Qty. Rate Unit
(A) Paver block & VDS Road
Box Cutting the road surface to proper slope and
camber for making base includinng removing the
excavated stuff and depositing on the road side slope
as directed up to 50 mt. lead.
Preparation of subgrade with Compacting, Levelling
and consolidation of subgrade with miniroller /plate
2 vibrator machine including watering and filling in 910.00 9.00 S.M.
depressions which occur during the process as directed
by engineer in charge.
Providing & laying Granular sub base (GSB)
confirming to Grading-V of Table 400.0 of compacted
thick of 150mm with specified graded stone metal and
sand mixed in place and laid with mechanical means
3 spreading with motor grader and compacting with 0.00 1,469.00 C.M. -
vibratory roller having minimum 80-100 KN static
weight to acheve desired density of 98% of MDD
including all material, labour, machinery with all leads
and lift etc. complete.
Providing & Laying C.C1:5:10 (1cement :5coarse
sand :10 graded stone agg. 40 m.m Nominal size )&
curing comp. excl. cost of from work in :Foundation
Providing and laying 200 micron plastic sheet on
prepared sub base For V.D.S Concrete
Supplying & filling fine sand(pana) in 75 mm /
mm / 150 mm compacted thickness over the base
including necessary compaction, watering etc.
complete. Item includes leveling by using vibratory
plates compacted machine and as directed by engineer
Providing 100mm thick readymade C.C. kerb of
strength M-20 (size 300mm x 380mm) purchased
from SMC's approved paverblock manufacturer &
setting in line, level and in truly vertical position,
7 including filling joints in C.M. 1:1 (1 part of cement :
1 part of stone dust) smooth pointing in C.M. 1:1 (1
part of cement : 1 part of coarse sand) including
watering etc. complete and as directed by engineer in
R.C.C kerb 380 mm depth and 300 mm width 125.00 228.00 R.MT
Sr. No. Description Qty. Rate Unit
Providing interlocking type Rubber moulded cement
concrete paver block of approved shape, design &
colour having 60mm thickness (M-35) purchased
from SMC's approved paverblock manufacturer only
& fixing of fine sand bedding. Item includes levelling
by using vibratory plates compacted machine. Item
also includes all materials, labour, equipments, tools,
plants, watering, cleaning etc. complete.
With colour 459.00 524.00 S.M.
Without colour 459.00 524.00 S.M.
Providing & filling with Mix soil in layers of 20 cm.
9 Th'. Incl. watering, ramming & consolidation etc. 279.00 225.00 C.M.
Filling in foundation and plinth with murrum or
10 selected soil in layers of 20cm. thickness including 50.00 301.78 C.M.
watering, ramming and consolidating etc. complete.
Providing & laying cement concrete Pavement using
1:1.5:3 (1 cement:1.5 sand:3 graded stone agg. 20 mm
11 nominal size) & Vaccuum Dewatering technique
including floating surface with a skim powder floater,
curing etc. complete
Internal road 0.00 5,981.00 C.M. -
Cutting of Groove 5 to 7 mm thick in VDS for depth
12 1/3 of total thickness with filling of epoxy sealent as 150.00 50.00 150
directed by engineer in charge
Providing and fixingTMT/CRS bar reinforcement for
13 R.C.C. work including binding and placing in position
Upto G.L./P.L. 0.00 77.29 Kg. -
Demolition including stacking of serviceable materials
1 and disposal of unserviceable materials with all lead 6.00 577.92 C.M.
and lift (ii) Unreinforced cement concrete
Demolition including stacking of serviceable materials
2 and disposal of unserviceable materials with all lead 9.00 1,110.75 C.M.
and lift (i) RCC work
Demolition of brick work and stone masonary
including stacking of serviceable materials and
disposal of unserviceable materials with all lead and
Sr. No. Description Qty. Rate Unit
Dismentalling tiled or stone floors laid in mortar
4 including stacking of serviceable material and disposal 30.00 50.11 S.M.
of unserviceable material with all lead and lift
Removing the scraping of old deteriosted plaster of
5 any thickness from wall/R.C.C. member and disposal 105.00 20.55 S.M.
of unserviceable from site of work with all lead.
Providing and fixing rebar of following diameter using
chemical grout of Swanchore/Hilti/Fischer or
equivalent make including cost of all equipments,
tools, material, labour, etc. Standard procedure as
mentioned in manufacturer's specifications shall be
strictly followed, which shall be submitted and got
approved from the authority prior to start of work. The
rate shall also include cost of drilling of hole of
required diameter and depth as mentioned in
manufacturer's specification, cleaning the hole with
required air blower and other necessary tools and
tackles, positioning, providing and grouting chemical,
allied fixtures and fasteners, etc. but excluding the cost
of reinforcing bar etc. complete. Item
includes necessary scaffolding, staging, labour, tools
and equipments, etc. complete as directed by the
engineer-in charge.
Dismentalling of R.C.C work by electric breaker, rate
to include all lead, lift , scaffoulding, transportation,
and labour etc. complete. As directed by engg.
(C) Compound wall
Boring holes 3.5 mt.deep in ordinary soil ( for cast in
situ piles) & disposal of the surplus excavated soil as
directed within a lead of 50 M. For following diameter
loose or soft soil
for 250 mm dia 91.00 334.80 R.M
for 300 mm dia 40.00 401.28 R.M
Sr. No. Description Qty. Rate Unit
Excavation for foundation includ.sorting out &
stacking of useful materials & disposing of the
2 excavated stuff upto 50 mt. Lead & all lift, watering
etc. Comp. (A) Loose or Soft soil Executed With
Mechanised Efforts / Machinaries
( 1 ) up to 1.5 mt. Depth 22.00 123.13 C.M.
Providing & laying cement concrete 1:4:8 (1 cement:4
coarse sand:8 graded stone agg. 40 mm nominal size)
& curing comp. excl.cost of form work in (A)
Foundation and Plinth
(A) Foundation and plinth 3.50 2,769.69 C.M.
Providing & laying cement concrete 1:2:4 (1 cement:2
sand:4 graded stone agg. 20 mm nominal size)&
curing comp. Includ.cost of form work but exclu. Cost
of reinforcement for reinforced concrete work in :
(A) foundation, footing, base of columns and mass
Providing & laying ordinary cement con.1:2:4 (1
cement: 2 sand: 4 graded stone agg. 20 mm nominal
5 size) finishing smooth curing etc. comp. Incld. Cost of
form work but excl. Cost of reinforcement for R.C.C.
Work in : Up to G.L./P.L
( B ) Ground Beam:
(1)Having c/s area up to 0.08s.mt
upto G.L./P.L. 9.00 8,593.80 C.M.
(2) Having cross sectional area 0.08 to 0.12 sq. mt .
Providing & laying ordinary cement con.1:2:4 (1
cement: 2 sand: 4 graded stone agg. 20 mm nominal
6 size) finishing smooth curing etc. comp. Incld. Cost of
form work but excl. Cost of reinforcement for R.C.C.
Work in : Up to G.L./P.L
(1) Having c/s area up to 0.08 sq.mt. 6.00 12,335.51 C.M.
Providing & laying C.C 1:3:6 (1cement :3 coarse sand
7 :6 crushed stone agg. 20 m.m Nominal size)& curing 5.00 4,085.83 C.M.
comp. incl. cost of from work in: wall caps/ copings.
Sr. No. Description Qty. Rate Unit
Filling available excavated earth (excluding rock) in
trenches. plinth, sides of foundations etc. in layers not
exceeding 20 cm. in depth consolidating each
disposited layer by ramming and watering.
Providing and fixingTMT/CRS bar reinforcement for
9 R.C.C. work including binding and placing in position
Upto G.L./P.L. 3530.00 77.29 Kg.
Brick work using common burnt clay building bricks
having crushing strength not less than 35 kg./Sq.Cm.
in Cement Mortar 1:6 (1- Cement : 6 -fine sand)(C)
At ground floor 46.00 4,729.83 C.M.
Half brick masonry in common brunt clay building
bricks having crushing strength not less than
11 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -
coarse sand ) in foundation and plinth (C)Fly Ash
At ground floor 0.00 712.81 S.M. -
Providing & Applying 10mm.th.cement plaster in
single coat on brick/ concrete walls similar surfaces
for plastering & finished even & smooth with a
floating coat of cement slurry mixed with admixture of
lime or neeru in required proportion etc. comp. in C.M
1:3 (1 cement : 3sand)
(A) For wall and similar surfaces
At Ground Floor 0.00 199.28 S.M. -
(B) For ceilings & soffits
At Ground Floor 0.00 225.34 S.M. -
Providing and applying 20mm. thick sand faced
cement plaster on walls or similar surfaces at all
13 floor levels,consisting of 12mm avrerage thick backing
coat of C.M. 1:3 (1 cement :3 sand ) and 8mm thick
finishing coat of C.M. 1:1(1 cement :1sand).
At Ground Floor 503.00 347.42 S.M.
Providing 35 mm wide throating or plaster drip and
moulding it to R. C. C. chajja etc. comp.. For all floor
At Ground Floor 0.00 43.74 R.M. -
15 Pro. smooth plaster patta
At Ground Floor 425.00 27.27 R.M.
Sr. No. Description Qty. Rate Unit
Providing 20 mm deep finished groove in plaster in
line and level etc. Comp. For all Floor (M.R.)
At Ground Floor 582.00 50.00 R.M.
Providing & applying two coats of weather shield max
paint (3 coats may be required in case of darker
colours.)of ICI Dulux or Apex Ultima of Asian Paint
including applying exterior acrylic primer coat as per
manufacturers specification and directions in shade
and colour approved by architects, on exterior surfaces
of the building including scaffolding, preparing the
surface, watering, curing etc. complete and as directed
by the architects and manufacturers. Surface
Preparation : surface is thoroughly clean, dry and free
from all loose dirt, chalk, grease, fungi, algae and
17 flaking paint. This can be achieved by brushing with a
wire/ stiff coir brush, followed by water jetting if
required. Fill up all minor cracks and defects with
white cement and sand mixture in the ratio 1:3. For
application on previously painted wall, previous
coatings of paint must be thoroughly scraped off and
Clean the surface thoroughly using wire brushes.
Priming Apply a liberal coat of exterior acrylic primer
and allow it to dry for 4-5 hours. Application of putty
is not recommended. Minimum 4-6 hours duration is
required between each coat of weather shield max
(A) For wall 503.00 82.00 S.M
Providing and fixing M.S. Gate of required pattern to
wooden frames of windows etc. at all floor levels with
18 M.S. flats at requuired spacing & frame aroundsquare
or reound bars with round headed bolts & nuts or by
crews incl. Priming coat of Red lead paint etc. comp.
Ground Floor 450.00 109.41 Kg
Providing & fixing M.S.Grills of required pattern to
wooden frames of windows etc. At all floor levels
with M.S. flats at required spacing & frame around
19 square or round bars with round headed bolts & round
headed bolts and nuts or by screws incl. Priming coat
of Red lead paint etc. comp. (A) Plain grill For all
All Floor 2021.00 109.41 KG.
Painting two coat (excluding priming coat) on new
steel and other metal surface with synthetic enemal
20 paint, burshing to give an even shade including
cleaning the surface of all dirt, dust and other foreign
Sr. No. Description Qty. Rate Unit
Ground Floor 76.00 68.57 S.M.
Steel work welded in built up sections, framed work
21 including cutting,hoisting, fixing in position and
applying a priming coat of red lead paint
(A) in beams & joists channels angles, tees, flats with
connection plates or angle cleats as in main & cross
beams,hip & trussed purlins connected to common
raffers & the like.
Providing & Fixing 80 mm dia M.S. pipe as vertical
post are beded in 1:1.5:3 concrete also horizontaly in
line and connecting to purline angle etc by welding
rereting etc. (a) Medium duty "B" Class
Providing & fixing colouron galvaniced steel, zinc /
aluminium allus coated sheet 0.5 mm. thick roofing
fixed with gslvanised grom J or L hook bolts and bolt
8mm dia with bituman and impet washer filled with
white lead etc. Excluding the cost of purlins rafter and
trusses. (Tata / Jindal or equivalent)
(D) Water Supply & Sanitary
Providing & construction simple chamber of 23 cm. th'
B.B. Masonary in C.M 1:5 with cement plaster 15 mm
th' in C.M. 1:3 inside & outside to exposed faces,
R.C.C. top slab with 1:2:4 mix ( 1 cement: 2 Sand :
1 Grade stone aggregate 20mm size) ,Foundation 15.00 2,932.93 No
concrete 1:5:10 & fixing C.I. cover with frame to be
not less than 38 kg. On top etc. comp. Inside
dimension,455 x 610 mm &450 mm deep for single
Providing, Lowering & laying joining R.C.C. NP2
CLASS Pipe In C.M. 1:1 of following nominal
internal diameters incl. Testing of pipes and joints etc.
Sr. No. Description Qty. Rate Unit
Providing & Fixing P.V.C. pipes (SCH-80) of Prince/
Supreme/ Jain/ Astral/ Tulsi/Finolex make for water
supply line at all floor levels incl. fixtures like bends,
tees, shoe etc joined with resin of approved brand &
3 manufacture etc. comp. Pipe shall be fixed on the wall
the help of clamp at every two meter C/C or shall be
concealed as directed including necessary fittings etc.
including testing of pipe and joints and fixing the same
with adhesive solvent, including cost of all materials.
Providing & Fixing C.P. Brass screw down bib tap
at all floor levels, polished bright etc. comp.
Providing & Fixing gun metal check or non return full
way wheel valve at all floors levels, etc. complete.
(E) RECHARGEBLE BORE WELL
Drilling 300 mm diameter borewell in all types of
strata up to required depth including cost of bentonite
powder, carting rings, cutter, other required materials,
labour charges etc. complete. The drilling shall be
done by mud flushed rotary equipment and bore holes
should withstand at least till completion of subsequent
activities like assembly jointing, lowering of casing /
strainer pipes, gravels packing, yield testing etc,
complete up to required depth as shown in drawing
and directed by engineer –in- charge.
Supplying and filling clean best quality of well sorted
"SEVALIYA" sorted pea gravel having size 6 mm to
2 10 mm in layer of required thickness in filter chamber 1.50 2,029.00 CM
as per drawing and as directed by Engineer –in-
Providing and fitting bail plug having length 0.45mtr.
3 from M.S medium class pipe as per ISI for 200 mm 1.00 1,500.00 NO
Sr. No. Description Qty. Rate Unit
Development of each water bearing zone come across
up to the depth of tube well (size 250 mm diameter &
4 depth more then 150 ft.) by lowering 100 mm 1.00 4,000.00
diameter drop line and 32 mm diameter GI air line for
each Zone with air compressor of capacity not less.
Providing & Fixing MS Clamps with threaded of
standard make suitable for ERW pipes.
(a) For 200 mm Diameter ERW blank pipe with size
750 x 75mm x 10mm thick suitable for 200mm 1.00 1,500.00 Pair
Excavation for foundation in and all kinds of soil
including leveling and ramming the bottom of trenches
and foundation pits, shoring, strutting, dewatering if
required, slush removing, filling the sides up to
original ground level for rectangular chamber and
Providing and laying Cement Concrete M-100 grade
1:3:6 (1 cement: 3 coarse sand : 6 hand brocken stone
aggregate 20mm nominal size ) and curing complete
excluding cost of form work in chamber
P.C.C(without forms work) work complete. .( S.O.R.-
Providing & laying Fly ash Brick masonary having
crushing strength not less then 70kg/sq.cm. 1:6 (1
8 cement : 6 fine sand) with scaffolding, watering, 1.47 4,511.97 CM
curing etc. complete with all labours and
materials.various area as directed by incharge .
Providing 10mm thick Cement Plaster in single coat
on brick/concrete walls far interior plastering up to
9 Floor two level and finished even and smooth in 4.00 189.79 S.M
cement morter 1:3(1 cement 3 sand various area as
directed by incharge) .
Providing, fixing M.S Jali frammed work (three piece
with handle fitting) on Opening portion Precast
10 Module Structure for Prevention of Recharge bore 31.00 90.47 KG
well structure,size including framme, heavy required
Angle (40 x 40 x 6mm), flat pati (25 x 6mm),cuttin
Sr. No. Description Qty. Rate Unit
Providing & Supplying 200mm dia mater 1.5mm
L.C.G (Low Carbon Galvanise) 'V' wire screen
pipe of Johnson or approved make ISI including
lowering, fixing, jointing in bore hole as per aquifer
depth and pipe assembly given as per site condition
Providing, Supplying, Fixing in bore hole 6Kg/cm2
P.V.C Pipe of approved Quality
12 (Prince,Suprem,Finolex) with ISI mark including 27.00 850.00 Rmt.
nesessary fittings and providing as per site sitution and
directed by Engineer –in- charge.200 mm dia
Providing, Supplying, Fixing P.V.C. 6 Kg/Cm2 Pipe
IS stanadard for down take / inlet from Bldg./
13 Structure to Sand filter Chamber, including piping/
plumbing, fitting, wall clamping, necessary excavation
and filling etc. complete as per site situation
(a) 110mm Dia.,6 Kg/Cm P.V.C. pipe. 3.50 325.00 Rmt.
(b) 160mm Dia., 6 Kg/Cm P.V.C. pipe. 10.00 525.00 Rmt.
Providing, supplying, fixing and installing M
Grade. precast size 1.5 dia x 2.35 mt. height ,top
14 75mm thick in 2 half pieces Sand Filteration chamber
(2 layer Type of Precast module )as per Design,
Drawing.including necessary excavation, filling, dr
(a) 1 layer type of Precast module 0.00 18,500.00 NO -
(b) 2 layer Type of Precast module 1.00 25,000.00 NO
Proving & fixing in position Johnson make and
equivalent ... 'V' wire L.C.G screen pipe 1.00 mm size
15 of filter assembly of pair –ID 205mm & OD
217.50mm of 0.5mm slot size and ID
mm and OD 428 mm of 1.00mm slot size as per
(a) 1.0 mt. length. 0.00 7,500.00 SET -
(b) 2.0 mt. Length. 1.00 14,000.00 SET
Borehole Video photography all the fresh new fresh
new bores or few selected as desired for better
understanding & clarity of work undertaken as
directed by Engineer -in-charge.
Supplying water tankers for constant water supply at
tube well Compressor work and cleaning of work site
17 after completion of entire job (testing) inluding 1.00 500.00 JOB
cleaning of mud etc.Location as directed by Engineer-
Sr. No. Description Qty. Rate Unit
Providing and Fixing Recharge Borewell name boards
as per standard I.R.C type design of steel plate
including painting lettering etc. complete with fixing
in C.C 1:4:8 block with necessary excavation.
Soil Investigation Test report from Govt.approved
authorised laboratary (Prior inserting bore Pipe) of
19 each bore shall be submitted by Contractor and soil 1.00 6,000.00 Each Bore
sample of various starta shall be first collected in
Polythene bag and than submitted in transparent
Removal of surplus excavated earth of excavated mud-
20 pits and water harvesting chambers up to the lead of 3.60 65.00 C.M
5.0 km as per the instruction of Engineer In Charge
ELECTRIFICATION WORK OF BUILDING
Point wiring for Light / Bell with 2-1.5 sq.mm &
earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in below type
of pipe erected with 6A Modular type switch / bell
push & accessories and earth continuity of following
type, erected on PVC / Metallic/Wooden box, single
mounting base frame covered with
textured/metallic/white front plate modules erected on
/ in wall / ceiling as per pipe erected, with necessary
Lamp holder/ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete Cat. III
(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete Cat. III
2 (For point wiring in bathroom and W/C and washbasin 0 224.73 Pt. -
area in residential quarters reduce overall rate by 5 0%
of point wiring for light.)
Sr. No. Description Qty. Rate Unit
Point wiring for secondary light point with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (green) both are of
ISI marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires, in below type of pipe to be
erected complete with earth continuity and necessary
connection with primary light with accessories erected
on Metal / PVC / wooden box covered covered with
appropriate front plate modules erected on / in wall /
3 ceiling for open / concealed wiring. with necessary 0 151.50 Pt.
Lamp holder / ceiling rose / H.D.Connector as
directed.as per pipe erected with following type of
Note:- Maximum up to 6 mtrs length, excess will be
considered as Mains for Secondary Point.
(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete
Point wiring for FAN with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (Green) both are of .ISI marked
KV Grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length, in below type of pipe
erected with 6A Modular type switch and hum free
EME step type electronic fan regulator mounted and
accessories with earth continuity of following type
4 erected on PVC / Metallic/Wooden box, single 28 629.23 Pt.
mounting base frame covered with
textured/metallic/white front plate modules erected on
/ in wall / ceiling as per pipe erected. with necessary
ceiling rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete, Cat. III
Point wiring for Individual Plug with & earth wire
of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper wires
up to 10 mtr length, in below type of pipe erected
complete with Modular type switch & 5 pin Plug
erected on PVC / Metallic/Wooden box covered with
appropriate front plate modules erected on / in wall /
5 ceiling as per pipe erected with following type of 12 473.69 Pt.
[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu.
Wire from nearby switchboard/mcb db board
(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete, Cat. III
Sr. No. Description Qty. Rate Unit
Point wiring for Individual Plug with & earth wire
of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper wires
up to 10 mtr length, in below type of pipe erected
complete with Modular type switch & 5 pin Plug
erected on PVC / Metallic/Wooden box covered with
appropriate front plate modules erected on / in wall /
ceiling as per pipe erected with following type of
[II] For 16A Plug and 16 amp switch with 2-2.5
sq.mm Cu. Wire from mcb db board.
(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete, Cat. III
Point wiring for Individual Plug with & earth wire
both are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate front
plate modules erected on / in wall / ceiling as per pipe
erected with following type of accessories.
[III] For 16A Plug and 16 amp switch with 2-4
sq.mm Cu. Wire with 2.5 sq.mm ( green) earthing
wire from mcb d b board.
(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete, Cat. III
Point wiring for on board Looped Plug with 6A
Modular type switch & 5 pin socket erected on PVC /
Metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate
modules erected on / in wall / ceiling with following
type accessories, Cat. III
Point wiring for Two Way Controlled Light Point
with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green)
both are of .ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires erected in below
type of pipe with 6A Modular type switches and
following type of accessories erected on PVC /
Metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate
modules erected on / in wall / ceiling as per pipe
erected. with necessary batten/angle holder or ceiling
rose or H.D.Connector as directed.
Sr. No. Description Qty. Rate Unit
(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete, Cat. III
but for 2 nos of 2.5 sq.mm FRLS PVC insulated
copper conductor wires with 1 no 1.5 sq.mm FRLS
9 PVC insulated conductor wire (Green color for 0 874.00 Pt. -
earthing) for 16 A AC starter with universal socket up
to satisfaction of E.I.C. (Excluding Main Line,
including 16A AC starter & Socket)
Providing following type of Modular Type
Accessories mounted with PVC / metallic/Wooden
box, single mounting base frame covered with textured
/ metallic/white front plate , modules erected with
necessary connections as per site situation directed by
Engineer In charge.
(3) Two Pin/RJ-11 Telephone Socket
[A] For One Gang, Cat. III 1 153.52 Ea.
[B] For Two Gang, Cat. III 1 200.99 Ea.
(4) TV Co-axial Socket outlet, Cat. III 1 153.52 Ea.
(7) Blank Plate Single, Cat. III 1 24.24 Ea.
(8) Computer RJ-45 socket, Cat. III 1 153.52 Ea.
(19) Modular Indicating Call Bell, Cat.III 1 314.11 Ea.
(20) Modular Buzzer, Cat.III 1 143.42 Ea.
(22) 16/20/25 Amp. Modular Starter for Motor / A.C.
Unit Complete, Cat. III
Providing and erecting ISI mark Medium class RIGID
PVC PIPES of following size complete to be erected
on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution
& Clamps with following dia of pipes, in approved
manner as directed.
Providing & erecting PVC Corrugated Flexible
Conduit with required nos. of coupling, PVC bushes,
12 Check-nuts etc. complete of following sizes.
Supplying & erecting UPVC Mini trunking (PVC
Casing-n-Capping) having double-locking
arrangement with grooves, trunking of size not below
12.5 mm in height as per IS with accessories of
13 PVC/Resin polypropylene not below 1.8 mm thick
duly sealed in joint & erected on wall / ceiling of
following size .
Sr. No. Description Qty. Rate Unit
Providing and erecting Mains with 1.1 KV grade
FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected
concealed in /flushed on wall/ceiling, with 1.5 sq. mm
copper conductor FRLS PVC insulated stranded wire
of green colour for earth continuity of following size
(A) With medium class Rigid PVC pipe and
(a) 2 wire 1.5 sq. mm 70 59.59 Mtr.
(b) 2 wire 2.5 sq. mm 310 78.78 Mtr.
providing and erecting Mains with 1.1 KV grade
FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected
in / on wall / ceiling with 2.5 sq. mm copper conductor
FRLS PVC insulated stranded wire of green colour for
earth continuity of following size
(A) with medium class Rigid PVC pipe and
(a) 2 wire 4 sq. mm 30 107.06 Mtr.
(d) 3 wire 4 sq. mm 159.58 Mtr. -
Providing & Erecting approved make following size of
TV Co-axial flexible cable comprising inner
conductor of solid bare copper insulated with Foam
16 PE & Secondary conductor made of poly - Aluminium
film bonded Al. Braids @ suitable coverage overall
sheathed with black PVC insulation.
Supplying & erecting approved make Telephone
Cable electrolytic copper conductor PE insulation
twisted in two pairs, & wrapped with FRLS PVC
tape & sheathed with FRLS PVC or HFFR outer
Jacket suitable for telephone wiring & confirming to C-
DOT erected in existing pipe. of following size of
conductors & nos.of pairs. With necessary
17 connections.
[A] Conductor Size 0.5 mm
(2) Two Pairs 0 19.19 Mtr. -
(b) Armoured [Jelly Filled]
(1) Ten Pairs 0 120.19 Mtr. -
(2) Twenty Pairs 0 190.89 Mtr. -
(3) Fifty Pairs 446.42 Mtr. -
Providing & erecting main Distribution (MDF)
indoor type, back mounted frame as per DoT standard
approved with krone strips
(a) Suitable for 10 pair 0 949.40 Ea. -
(b) Suitable for 20 pair 0 1,311.99 Ea. -
Sr. No. Description Qty. Rate Unit
(c) Suitable for 50 pair 1,678.62 Ea. -
Providing & erecting Switch board for Computer
or electric apparatus consisting of following items
in single board erected on PVC / Metal/Wooden
board concealed/open with 3 mm thick PC
19 (Polycarbonate) / Acrylic sheet erected as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug
For Modular Type Accessories, Cat. III 0 1,081.71 Ea. -
L.T. SWITCHGEAR AND DIST. BOARD & L.T.
MICRO. BASED LSGD RELEASE MCB ,
R Y B INDICATOR
ON OFF INDICATIOR
40 AMP., 4 POLE MCB-B CURVE, 10 KA, WITH
ON OFF INDICATOR : 4 Nos.
40 AMP., 4 POLE MCCB, 25 KA, FOR FIRE PUMP
- WITH ON OFF INDICATOR : 1 No.
32 AMP., 4 POLE MCB-C CURVE, 10 KA, FOR
20 DRINKING WATER PUMP WITH ON OFF 0 1,52,762.50 Ea. -
INDICATOR : 1 No.
32 AMP., 4 POLE MCB-CURVE, 10 KA,WITH ON
OFF INDICATOR (SPARE) : 1 No.
63 AMP., 4 POLE MCB-B CURVE, 10 KA (SPARE)
WITH ON OFF INDICATOR : 1 No.
40 AMP., 4 POLE MCB-B CURVE, 10 KA,
(SPARE) WITH ON OFF INDICATOR : 1 No.
16 AMP. 4 POLE MCB-B CURVE, 10 KA, (SPARE)
WITH ON OFF INDICATOR : 1 No.
16 AMP. ., 2 Pole, MCB-B CURVE, 10kA, (SPARE)
WITH ON OFF INDICATOR : 1 No.
16 AMP., 2 Pole, MCB-C CURVE, 10kA, (SPARE)
WITH ON OFF INDICATOR : 1 No.
Providing and erecting Sheet Steel powder coated
MCB distribution board - flush / surface mounted
fitted with busbar, neutral link, earth bar and DIN rail,
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without
MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used)
(B) three phase incoming and single phase horizontal
21 type outgoing Per phase isolation type (PPI)
Sr. No. Description Qty. Rate Unit
(b) sheet steel double door
(iii)8 way (As Main GFLDB, FFLDB, SFLDB,
(iii) 8 way (As Raw Power DB {RPDB} GF + FF +
(ii) 6 way (As A.C. DB {ACDB} GF + FF + SF) 3,437.03 Ea. -
RCCBs, 30 mA, 10 KA, 40 Amp., FP, Cat. III
23 MCB, 10 KA, 40 Amp., FP, Cat. III (INCOMER) 2 638.32 Ea.
RCCBs, 30 mA, 10 KA, 25 Amp., DP, Cat. III
MCB single pole 6A to 25A, 10 KA Cat. III (10
Providing & erecting 240 V MCB double pole switch
for motor & inductive load (C Curve) having
26 KA breaking capacity & confirms to IS : 8828 in 1 299.97 Ea.
existing box having following capacity, Cat III, (A)
Providing & erecting 240 V MCB double pole switch
for lighting Load (B Curve) having 10 KA breaking
capacity & confirms to IS : 8828 in existing box
having following capacity, Cat (III), 6 to 32 Amp.
Providing & erecting 415 V MCB Four Pole for
Motor & Inductive Load (C Curve) having 10KA
breaking capacity & confirms to IS :8828 in existing
box having following capacity, Cat III, 6 to 32 Amp.
Supplying & erecting approved make Electronics
Starter and relay for air conditioners in ABS plastic
moulded housing. Company fabricated with bakelite
terminal for connection with silver coating bimetallic
contact in switching device for o/p with following
(1) Low Voltage Protection below 130 V
(2) High Voltage protection above 270 V
(3) Overload protection for 2-5, 4-10, 8-14, 10-16, 14-
22 Amp. (inverse time chara-)
(4) Indicating LEDs for AC on LV, HV, O/L, T/D
(5) With unique feature of 3 minute of time delay
Plastic enclosure fitted with DIN rail suitable for
incorporating One / Two nos. MCB
Plastic enclosure fitted with DIN rail suitable for
incorporating Three /Four nos. MCB
Sr. No. Description Qty. Rate Unit
Sheets steel powder coated enclosure suitable for
incorporating One/Two nos. MCB.
Providing and erecting metallic vitrified danger
notice board as per language suggested by engineer
incharge for MEDIUM VOLTAGE installation to be
erected as per IS-2551.
Providing & erecting Medium Voltage Danger
34 Notice Board sticker as per language suggested by 0 26.26 Ea. -
engineer incharge of standard size as per IS-2551
INDOOR LIGHTING ITEM
Supplying and erecting LED indoor fittings with
LEDs of wattage 0.2 Watt to 0.5 Watt assembled on
single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS:
513/CRCA/ aluminium die cast powder coated and
high U.V. & corrosion resistance with diffuser with
company mark/name 160V to 270V, Power Factor
more than 0.9, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80
35 Certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Tube Light with integral driver
(i) 5-10 Watts, Surge-2 KV, IP-20, conventional 1 to
2 feet, Cat. III
(iii) 18-20 Watts, Surge - 2KV,IP-20, conventional
(iv) 22-24 Watts, Surge - 2KV,IP-20, conventional
(v) 36-40 Watts, Surge-2 KV, IP-20, conventional
Supplying and erecting LED lamps with following
wattage capacity of 220 to 240 voltage, minimum
15000 burning hours life, 500 V in built-surge
protection,Polycarbonate diffuser, mounting suitable
36 for E14 / E27 / B22 lamp holders, pf >=
(A) LED Lamps integral type, with PC diffuser
suitable LAMP holder, Cat. III
(i) 2 to 3 watts 0 69.69 Ea. -
(ii) 5 to 8 watts 15 112.11 Ea.
Sr. No. Description Qty. Rate Unit
Supplying and erecting LED indoor fittings with
LEDs of wattage 0.2 Watt to 0.5 Watt assembled on
single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder
coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with
company mark/name
160V to 270V,Power Factor more than 0.9, THD <
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed
Mount Downlight with provision for spring loaded
mounting clips complete.IP20
(ii) 11-15 watts, Surge-2 KV, Cat. III 0 427.23 Ea. -
(iii) 16-20 watts, Surge-2 KV, Cat. III 0 589.84 Ea. -
(iv) 22-24 watts, Surge-2 KV, Cat. III 0 758.51 Ea. -
(B) LED Panel Light with provision for Plane front
frame with translucent cover fixed to housing
(vi) 36 watts, 24" x 24", Surge- 2KV, Ct. III 2,348.25 Ea. -
(G) Step Light having Aluminium die cast and ABS
Plastic material.
(i) 5 watts, Direct/Indirect luminaire, Cat. III 747.40 Ea. -
Supplying and erecting LED street light / Flood light
fittings with High power White LEDs wattage of
Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with smooth
finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/
lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy>
100 lumens/watt . LED driver efficiency > 85 %.(
fittings required LM-79 & LM-80 certificates)(NOTE:
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges
Sr. No. Description Qty. Rate Unit
(A) Street Light (IP-65), Surge protection -4KV
integral and ,Light must have 440VAC line supply
with over-voltage protection.
(iv) above 90 to 120 watts, Cat. III
(Wall mounting outside)
Outdoor street light fitting side entry with clear
acrylic /plastic / polystyrene cover complete with
starter, polyester choke copper wound complete
erected with 40/36 watt tube holders. with lead wire
and connections. (For Second Floor terrace)
(a) With 1 tube 40 watt.120 cms, Cat. III 1,111.00 Ea. -
(B) LED Panel Light with provision for Plane front
frame with translucent cover fixed to housing
(vi) 36 watts, 24" x 24", Surge- 2KV, Cat. III 0 1,794.77 Ea. -
Supplying and erecting LED street light / Flood light
fittings with High power White LEDs wattage of
Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with smooth
finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/
lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy>
100 lumens/watt . LED driver efficiency > 85 %.(
fittings required LM-79 & LM-80 certificates)(NOTE:
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges
(B) Flood Light (IP-65), Surge protection -4KV
integral and ,Light must have 440VAC line supply
with over-voltage protection.
(iv) above 90 to 120 watts
Supplying and Erecting Of L.E.D. type High bay
fixture having Power Consumption of following watts
with, Input Voltage 110 - 290 V.AC with full
efficiency, Power Factor > 0.9 with 50/60 HZ, CCVC
LED Driver used for maximum power saving, Best
Quality luminium alloy housing and aluminium Dome
for etter heat dissipation, CCT Cool white (6000K),
CRI 80, Beam angle > 120 dgrees, working
temperature -20 degc to +55 degc, Body IP
OUTDOOR LIGHTING ITEM
Sr. No. Description Qty. Rate Unit
Supplying and erecting B class Galvanized iron pipe
having smooth finished bore of the pipe on both ends
erected nuts and bolts along the pole / wall shaping
the pipe as per site requirement. Pipe dia as following.
(A) 25 mm dia 212.10 Mtr. -
(B) 32 mm dia 252.50 Mtr. -
Supplying & erecting approved make SMC press
moulded composite FRP. loop-in, loop-out approx.
2mm thick box complete with Bakelite connector strip
5way(3P+N+E),DIN rail for mounting mob & hinged
40 doors as per requirement having locking arrangements
with mounting clamp with nuts, bolts & washers
suitable for erection on pole with cable clamps& earth
bolt of following size of box.
(F) 200mm x 180mm x 100mm [deep] 639.33 Ea. -
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand / Solid Copper
conductor for 1.1 KV. to be laid on wall with
41 necessary clamps or in existing trench / pipe at road
crossing or floor of following size of cables. (For
wall mounted street light / flood light luminaries)
(B) 4 core 4 Sq. mm 426.22 Mtr. -
Providing and, fixing heavy duty flange type brass
cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails,
insulating tape etc for following size of cables. (For
wall mounted street light / flood light luminaries)
(A) 2 to 4 core 2.5 / 4 Sq. mm 37.37 Ea. -
Solder less crimping type Copper lugs conforming to
IS suitable for cable of following size evenly crimped
with high pressure tool & connected to switchgear
43 terminals with brass/cadmium plated nut bolts in an
approved manner. (For wall mounted street light /
flood light luminaries)
Sr. No. Description Qty. Rate Unit
Supplying & erecting approved make IP 55 grade
Company fabricated Timer Panel of following
capacity for switch On-Off street lights on time
scheduling basis made from 16G CRCA sheet duly
epoxy power painted inside and outside with hinged
doors and locking arrangement consisting of suitable
44 size of 4 Pole MCB and 4 pole contactor (cat-III)with
analog time switch, auto manual switch of same make
and suitable input and output Bakelite terminals and
with door earthing approved by Engineer in
charge.(For wall mounted street light / flood light
FAN AND RELEATED ITEM
Supply, Installation, Testing and Commissioning of
suitable sweep, BEE 5 Star rated, Ceiling fan with
Brush Less Direct Current (BLDC) permanent
ferrite magnet Motor, class of insulation: B, Rust free
3 nos.Aluminium blades, 2 nos. canopies, shackle kit
with earthing provision, copper winding, Power factor
not < 0.9, Service Value (CMM/W) minimum 6.85,
Air delivery minimum 215 CMM, 350 RPM,230v
(tolerance as per IS : 374-2019), THD < 10%,
compitible with electronic regulator unit for Speed
Control and all remaining accessories including safety
pin, nut bolts, washers, temperature rise = 75 degree C
(Max.), suitable for 140 to 285 Voltage and rectifier
circuit with surge, over current and overload
protection , 50 Hz, Single phase AC Supply, earthing
etc. Complete as required.[ Make shall be approved by
Engineer in Charge]
(A) 1200 mm Sweep (48")
Providing & erecting Approved make Power Saving
50 Watt Ceiling Fan with double ball bearing ISI
mark with Condenser 230 volt A.C. 50 Hz 1200 mm
69 sweep complete having 3blades with aluminium 1,948.29 Ea. -
blades with , canopy & 30 cm. down rod erected with
earthing.(Make shall be approved by Engineer in
Supplying and erecting 19 / 20 mm. nominal bore
Medium Class M.S. Pipe down rod erected duly
painted for fan complete with proper insulation
without leakage and earthing.
Supplying & erecting fan hook box of 10 mm M.S.
round bar bounded to the RCC bars up to 50mm
42 length each side and pierced through a 16 Gauge M.S. 15 108.07 Ea.
box / Heavy Duty PVC box complete erected
concealed in Ceiling with necessary finishing.
Sr. No. Description Qty. Rate Unit
Providing 2.5mm.thick laminated acrylic sheet to
cover the fan hook or Fan box.
Supplying & erecting single phase approved make
industrial exhaust fan suitable for medium duty ring
44 mounted low noise operation suitable for medium duty 3 2,054.34 Ea
having following dia size and maximum speed in RPM
[A] 305 mm dia 900 RPM, Cat. III -
Providing & erecting fresh air fan 250 mm dia with
45 square frame make of ABS body with louvers, Cat. 10 1,559.44 Ea
Supplying and erecting approved make oscillating
type medium duty bracket fan with Aluminium
Blades A.C. 23OV. 50cy/s, with thermal overload
protection wall mounted with height adjustment and
rotary tilting device complete with guard, pull cord for
speed and oscillation flexible Core plug top complete
erected with lead wires as directed.
Supplying and erecting approved make oscillating
type heavy duty bracket fan with Aluminium Blades
A.C. 23OV. 50cy/s, with thermal overload protection
wall mounted with height adjustment and rotary tilting
device complete with guard, pull cord for speed and
oscillation flexible Core plug top complete erected
with lead wires as directed.
EARTHING SYSTEM
Providing and erecting required size HOT deep
Galvanised iron strip for earthing of H.T. , OCB/
ACB/ Transformer LT panel board, Motors etc. using
Providing and erecting Annealed bare Copper wire
Providing and erecting HOT deep Galvanised iron
strip wire 8 to 16 SWG.
Providing and erecting Pipe type earthing having
150 cms. long and 2.5 cms. dia. galvanised iron pipe
with coupling and buch buried in specially prepared
earth pit complete with necessary 8 SWG earth wire.
Providing and erecting Pipe type earthing with
mm dia 2.5 mtr long 'B' grade G.I. pipe with
58 necessary coupling buch buried in specially prepared 969.60 Ea. -
earth pit & G.I. earth wire of 8 SWG erected &
connected as directed
For using salt and charcoal / coke as required for
pipe type earthing.
Sr. No. Description Qty. Rate Unit
Supplying & erecting in earthpit of minimum bore dia.
225mm size approved make Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-
1987 made of corrosion free hot dipped G.I.Pipes
having Outer pipe dia of 80 mm having 80-200
Micron galvanising, Inner pipe dia of 40 mm having
200-250 Micron galvanising, connection terminal dia
of 14 mm with constant ohmic value surrounded by
highly conductive compound with high charge
dissipation suitable for following type of applications
with chamber and heavy duty cover.(approved make
OEM has to submit test certificate including value of
earth resistane of installation.
[B] For Electrical installation up to 11 KV located in
other than normal soil i.e. Soft Rock, Marshy Soil etc.
-Length of Pipe : 2 mtr 0 7,095.25 Ea. -
-Back filling Compound :1 no. Bag of 25 Kg. two for
body earth and one for neutral earth
[C] For Electrical Installation covering Transformer
Neutrals, Lightning arrester Earthing, A.C.Plant &
Sensitive Computer System(like Automation,
SCADA)i.e. independent Earthing located in other 1 10,593.89 Ea.
than normal soil i.e. Soft Rock, Marshy Soil etc..
-Length of Pipe : 3 Mtrs.
-Back filling Compound :2 nos Bags of 25 Kg.
CABLES, WIRE AND TERMINATIONS
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor
for 1.1 KV. to be laid on wall with necessary clamps
61 or in existing trench / pipe of following size of cables
(From DISCOM energy meter to Main L.T. panel)
(G) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2 core) 855.47 Mtr. -
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
1.1 KV. to be laid on wall with necessary clamps or in
62 existing trench / pipe at road crossing or floor of
following size of cables.
Making trench in soft soil of suitable width of 90 cm
deep for laying cable or locating the fault all over the
run and back filling the same and making the surface
as normal ground.
Sr. No. Description Qty. Rate Unit
Providing & laying. R.C.C. Hume pipe for cable to
be laid 90 cm. below ground across the road crossing
54 or on floor with necessary material in an approved 0 226.24 Mtr. -
manner and making the ground as per original. (F)
Providing & laying approved make Double walled
corrugated pipes (DWC) of polyethylene(conforming
to IS 14930 II )with necessary connecting accessories
of same material at required depth in existing trench
for laying of cable. below ground / road surface for
enclosing cable, (A)50 mm outer dia
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
1.1 KV. to be laid on wall with necessary clamps or in
56 existing trench / pipe at road crossing or floor of
following size of cables.
(A) 3 1/2 core 25 Sq. mm ( 10 Sq. mm 1/2 core) 10 1,345.32 Mtr.
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand / Solid Copper
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe at road
crossing or floor of following size of cables.
(A) 4 core 2.5 Sq. mm 0 269.67 Mtr. -
(B) 4 core 4 Sq. mm 10 362.59 Mtr.
(C) 4 core 6 Sq. mm 10 508.03 Mtr.
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor
for 1.1 KV. to be laid on wall with necessary clamps
or in existing trench / pipe at road crossing or floor
of following size of cables.
(A) 4 core 10 Sq. mm 10 673.67 Mtr.
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor
for 1.1 KV. to be laid on wall with necessary clamps
or in existing trench / pipe at road crossing or floor
of following size of cables.
(B) 4 core 16 Sq. mm 10 984.75 Mtr.
Providing and, fixing heavy duty flange type brass
double compression type cable gland with rubber
ring for PVC insulated armoured cable complete with
out going tails, insulating tape etc for following size of
Sr. No. Description Qty. Rate Unit
Providing and, fixing heavy duty flange type brass
double compression type cable gland with rubber
ring for PVC insulated armoured cable complete with
out going tails, insulating tape etc for following size of
(A) 3 & 1/2 / 4 core 25 Sq. mm
Providing and, fixing heavy duty flange type brass
cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails,
insulating tape etc for following size of cables.
(A) 2 to 4 core 2.5 / 4 Sq. mm 1 33.33 Ea.
(B) 2 to 4 core 6 Sq. mm 1 38.38 Ea.
(C) 2 to 4 core 10 Sq. mm 1 43.43 Ea.
(D) 2 to 4 core 16 Sq. mm 1 54.54 Ea.
(E) 2 to 4 core 25 Sq. mm 1 59.59 Ea.
Solder less crimping type Aluminium lugs
conforming to IS suitable for cable of following size
evenly crimped with high pressure tool & connected to
62 switchgear terminals with brass/cadmium plated nut
bolts in an approved manner.
Solder less crimping type Copper lugs conforming to
IS suitable for cable of following size evenly crimped
with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an
63 approved manner.
Supplying & erecting approved make LAN cable of
64 following size in existing pipe as per direction [C] 0 45.45 Mtr -
WATER COOLER AND PURIFIER
Providing and erecting water cooler having storage
capacity 80Ltr. & cooling capacity 40 Ltr.per hour @
an ambient temp of 45˚ C. The outlet temp. of the
water should drop by 15˚ C within a hour, The water
cooler should be comprising of hermetically sealed
compressor, fan motor, condensing unit, water tank
surrounded by evaporating coil, thermostats, relay etc.
complete with necessary inlet & outlet connection.
The body of water cooler will be made from Stainless
SITC of Water Purifire Eureka Forbs Make AG
Sr. No. Description Qty. Rate Unit
PUMP SETS AND STARTERS
Providing & erecting open well type horizontal
mono block pump set with stainless steel body
having following specification.
(D) 1 HP Three phase open well motor pump set
suitable for 190 LPM discharge @ 21 mtr. head,
suitable for 32mm dia. delivery pipe.
Supplying submersible pump set suitable for bore
of 100 mm. dia. or more having three phase motor
capacity not more than 3 H.P. of different range with
68 following capacity 0 20,901.95 Ea. -
(A) (20 stage) 170 to 185 LPM discharge at 57 to
mtrs. Respectively head suitable for 50 mm dia.
delivery pipe, Cat. III
Supplying & erecting approved make self-priming
domestic monoblock water pump with 1 H.P
motor, suitable for operation on 230 volts, 50c/s. AC
69 supply with metallic flange, and M.S. impeller 1 7,679.03 Ea.
delivery and following discharge
(a) 40 LPM at 24 mtrs. head suitable for 25mm dia.
Delivery. Cat.III
Supplying and erecting push button operated fully
automatic Star-Delta starter with 3 Nos. of
15A.rating contactors and directly operated thermal
overload relay having 10-21A range and erected in
87 sheet steel enclosure for 3 phase 415V. 50 c/s. A.C.
motors from 7.5 to 15H.P. complete erected on
(A) P.W. Block with necessary connection, Cat.III 10,483.80 Ea. -
(B) Angle iron frame add to the above 204.02 Ea. -
Supplying and erecting Direct On-line Electronics
Starter with 2-5/4-10/8-14/10-16 Amp. Rating relay
(variable current setting) directly operated in totally
insulated elegant enclosure and 18 Amp. Rating power
relay with start - stop button for single phase operation
up to 3 HP as per complete erected on P.W. Block
with following features.
Low voltage cut off below 140 V
High voltage cut off above 280 V
Overload protection
Indicating LEDs for motor on lv, hv & overload
tripping. [Cat.II]
Supplying and erecting Direct-on-line, Starter with
15A.rating contractor and with 4-14A. range, directly
operated thermal overload relay in sheet steel
enclosure for 3phase 415V.50 c/s. A.C. motor up to
7.5 H.P.complete erected on P.W. Block with
necessary connection. Cat.III
Sr. No. Description Qty. Rate Unit
Supplying & erecting approved make Automatic
liquid level controller 6A. with sensor testing as per
72 instruction of Engineer in charge on site complete with 1 2,355.32 Ea.
wiring connection with existing wires , with copper
conductor from pump to upper and lower tank.
Supplying & erecting 20 Amp 10 KA ‘C Curve’
single pole MCB with 20 Amp. Plug socket,
company fabricated powder coated sheet steel
enclosure erected as directed with connection.
[A] Metal Clad Socket with metal clad top. Cat.III 1 527.22 Ea.
[B] 15 Amp. / 5 Amp. Five pin Universal Socket
Supplying and erecting, commissioning and testing of
Diesel Generating set confirming to IS: 4722:1968 &
BS:5514 having continuous rating, 3 phase, 415 volts,
50 cycles A.C. supply comprising of a totally enclosed
air/water cooled diesel engine with multi-cylinders
developing suitable BHP not less than following
capacity at 1500 RPM with 10% overload for one
hour in 24 hours with standard accessories like fly
wheel, lubricating oil cooler, "A" class governor,
heavy duty fuel wheel and lubricating oil filter, oil
bath air filler, lubricating oil pressure gauge, end
exhaust manifold, standard set of tools with adjustable
spanners, screw drivers, cylinder head to cover, joint
cylinder head to exhaust, element lube oil filter, 12 /
24 volts electric starting equipment complete with
standard heavy duty battery, dynamo, cut-outs,
ammeter, necessary wiring, pressure gauge, starter etc
and heavy duty Residential type exhaust silencer and
vertical hot air duct both
Sr. No. Description Qty. Rate Unit
logged with asbestos rope, save oil trays, exhaust
piping of required length, standard wall/floor mounted
fuel with level indicator and piping and drip proof
alternator, self excited, self regulated, screen
protected, with excitation system, capable of
delivering the rated system output at 415 volts,
phase, 0.8 PF, 50 Hz, 4 wire, running at 1500 RPM,
74 conforming to IS-4722- 1968 with voltage regulation
+/- 5% of rated voltage from no load to full load. Both
the engine and alternator fitted on a common
fabricated steel base plate with antivibration mounting
engine and alternator both connected to each other
by flexible flange coupling and with floor/wall
mounted control panel box comprising of voltmeter
ammeter, selector switches, ACB / MCCB / MCB of
adequate capacity,
indicator lamps duly wired with HRC fuses. The
alternator & control panel shall be connected with
provided suitable capacity armoured cable and
complete with Acoustic enclosure (canopy) made out
of 16 SWG CRCA Sheet, sound absorbing material
Rockwool of 64 density & 100 mm thick conforming
to IS:8183 / PU Foam of 40 Density - at least 40 mm.
The resin bonded rockwool covered from inside the
canopy by perforated sheet with 3/4 mm holes, sound
level not more than 75 dB at a distance of 1 mtr, as per
PVCT norms. Erection, commissioning and
satisfactory testing as per requirement with first filling
of fuel, oil, etc. with guarantee / Warrantee of
complete system for Two years. & with obtaining all
necessary certificate from Electrical Inspector. The
Capacity and Ratings of DG sets are as below.
(H) Continuous Rating of 50 KVA ,BHP not less
Sr. No. Description Qty. Rate Unit
Providing & erecting approved make AMF control
panel suitable for following size of 3 phase, 415 V.,
50 cycles, A.C. diesel generating set complete of
scope as detailed below:
1) Power module: A pair of electromechanically
interlocked contactors (for mains & generator)
Overload relay for generator contactor Neutral
contactor for mains and generator Power socket for
2) Control and metering module: Line voltage
monitor. Generator voltage monitor Ammeter 3 items
attempt start facility. Air circuit breakers/MCB/MCCB
75 of suitable rating for auto/manual operation.
Auto/manual switch. Emergency stop push buttons.
Manual start push button. frequency meter. Engine
hour meter. Two earthing studs.
3) Protection module: The engine shutdown in the
unlikely event of Low lube oil pressure High cylinder
head temperature. V belt failure.
4) Indicators with alarm Load on generator.
5) Indicators Load on mains Engine fails to start .
Emergency stop battery charger.
The AMF Panel of following capacity
(A) AMF Control Panel for 50/62.5 KVA 3 phase
(A) GENERAL DESCRIPTION OF LIFTS.
[1] GEAR LESS LIFT DRIVE (MRL) comprising of
High Starting torque Lift 3 phase 440 V A. C.
Permanent Magnet Synchronous motor of proper
rating with high efficiency shall be used.[2] Micro
processor based / PLC, ACVVVF, vector control drive
with encoder feedback closed loop system shall be
used for lift car and door operation which shall be full
collective selective operation hall call demand
response, UP/DOWN hall stops, Main, Up/ Down
Contactor with overload and phase reversal relay and
safety controls.
Sr. No. Description Qty. Rate Unit
[3] Car with M S platform with bracings of adequate
size and to sustain the impact load cabin + passenger
with safety factor of fire for steel and side panels of
Stainless steel of sheet of grade 304 duty. Car ceiling
will be S.S. finishes with aesthetic appearance with
LED ceiling lights. Car flooring shall be of anti skid
PVC with choice of colour of engineer in charge. Car
doors shall be of stainless steel grade 304, hairline
finish with centre opening / telescopic automatic
doors. Car panel will also be S.S. 304 finished with
emergency stop device, mechanical door safety device,
facility of auto/ attended mode. All car panel buttons
and all floor switches must be with brail language as
[4] All landing doors must be fire rated for 2 hour
shall be fully automatic centre opening/ telescopic
opening made of hairline finish steel grade of 304 with
key holes and infrared curtains with Unlocking facility
[5] Appropriate battery operated emergency light in
the car along with alarm switch shall be provided.
Also, Emergency Light & Fan should start
immediately without any Time Delay as soon as power
[6] Digital scrolling indicator system for up-down
arrow along with floor position indicator shall be
provided inside the car and at all floors.
[7] Full height infra red curtain with multiple cross /
crossing light beams shall be provided.[8] Automatic
Rescue Device (ARD) shall be provided accordingly
of passenger capacity with Manual Rescue Operation (
Manual Cranking Facility).
[9] Audio visual indication in the lift car showing over
loading shall be provided such that doors kept open till
excess load is removed.
Sr. No. Description Qty. Rate Unit
[10] Spring buffers/PU Buffers shall be provided.
[11] Car fan as per passenger capacity with automatic
sleep timer shall be provided.
[12] Voice annunciator with suitable music shall be
provided in lift car.
[13] Self diagnostics system for operational and safety
parameters shall be provided in control panel.
[14] Mechanical over speed governor with governor
calibration as per actual site parameters and
submission of calibration certificate submission, door
key holes in the floor doors, fireman switch shall be
[15] Lift machine hoisting arrangement in the lift
machine room and monkey ladder for lift pit should be
provided by the lift agency, along with the other steel
structure works, foundations for the machine etc…
[16] In the hoist way fascia plate shall be provided
without any extra cost, where ever required as / if
directed by engineer in charge.
[17] Permanent wiring with necessary safety devices
like RCCB in all circuit, Over Voltage Under Voltage
protection and THD eliminator in circuit for lift
machine room and lift well with proper numbers of
light points, with fixtures, exhaust fan and plug points
shall be provided by the agency. Only 3 phase Power
Supply shall be made available by department in lift
machine room. Necessary Earthing as per Lift
Act/Rules shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional and
alteration in lift shaft and machine room related to
erection of lift shall be made by lift agency without
any extra cost. (granite/marble fixing around all
landing door openings are not in lift agency’s scope.)
[19] Agency has to provide all working drawings and
documents and liaison services for obtaining all
necessary permission from lift inspector and other
authorities. [20] acrylic transparent
licence/display A4 size holder in lift car
Sr. No. Description Qty. Rate Unit
[20A] As per statutory requirement of Govt. Of
Gujarat lift & escalator act 2000, lift agency has to
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection during/after
lift erection and provide report by third party
authorized by concern licensing authority
5.agency has to provide third party insurance upto
completion of free maintenance period and submit the
document for the same.
[21] Car Panel Operating Buttons with floor position
indicator/buttons must be of Auto Glow type clearly
visible when view from inside cabin.
[22] For Physically Handicapped person Full Length
Handrails of hairline finish steel grade of 304 should
be provided at appropriate height on the Rear & Side
Wall Panels in Lift Car.
(B) SPECIAL FEATURES DESCRIPTION OF
LIFTS for PREMIUM category
1. Advanced control system dual 64 bit embedded
microprocessor with CANBUS Serial Communication
mode including Regenerative power efficient
operation,on site programming facility, Anti nuisance,
Pte-opening, BMS/RMS with necessary online real
time monitoring system having necessary connectivity
for remote monitoring & other suitable supporting
hardware & software devices to fulfil the purpose.
2. Floor Indication LCD Display with call registration
& brail mark with arrival gong and hall lantern & TFT
Screen in the car with MP3 Voice Announcer.
3. CAR Panel should be Scratch resistive SS
Moonrock finish / Hair Line / Honeycomb for car and
all Doors, All landing doors must have fire rating up to
2 hours and car door must have multi-level crisscross
beam door protection.
4. To & fro communication system & wiring (i.e. car
control room & guard room ) and Each elevator are
equipped with remote monitoring system.agency has
to provide mobile app and user id and password for
15/16 Passengers, Ground plus 2 upper floor with
Rated Speed of 1.0 m/sec., (strecher lift)
(C) With General PLUS ADDITIONAL SPECIAL
FEATURES attached herewith. Prem. Cat.
INVERTOR STABILIZER
Sr. No. Description Qty. Rate Unit
Supplying and erecting of 1850VA Sine wave Digital
Inverter systems.
Supplying and erecting of 12V/150AH Tubular
battery for 1 hrs battery backup.
84 Supplying and erecting of 1KVA Stabilizer. 10,225.64 Ea. -
Supplying and erecting approved make online Un-
interruptible Power Supply system comprising flat
cum-boost charger, static Inverter & sealed
maintenance free SMF batteries. The charger having
operating capacity for input 160-270V AC & inverter
having output 230V,50 Hz Ac with 0.8 load power
78 factor with battery, over/under voltage output with 0 24,822.77 Ea. -
over load & short circuit protection equipment. The
system housed in CRC sheet duly powder coated paint
with following power backup.with MS painted
batteries stand, 10% Overload capacity for momentary
load. (FOR class room)
(A) 1 KVA with 1Hr Backup
Wall Mount Speaker
SETC of Philips/Ahuja Make or equivalent
High power ABS wall mounting box speaker in gray
colour for indoor public address and background
music in locations of high ambient noise. Ideal for
79 Schools. 0 2,152.19 Ea. -
Input Power : 25W RMS
Power Tapes on 100V : 25/15/10/5W
Impedance : 400/670/1k/2kΩ
Frequency Response : 120-15,000Hz
SPL at 1kHZ (1W/1m) : 94dB
Sr. No. Description Qty. Rate Unit
SETC of Philips/Ahuja Make or equivalent
High Wattage PA Mixer Amplifier
6 Mic & 2 Aux Inputs.
Preamplifier and Line Output for connecting to a
Booster Amplifier and for recording the programme.
Line Input for connecting the output from any external
mixer or permitting to be used as a Booster Power
Resettable circuit breaker for protection against
overload and short circuit.
Instant transfer to DC power (Car Battery) if AC
Box Speaker/Driver Unit selector switch. Bass boost
80 defeated at Driver Unit position for safer operation of 0 21,735.46 Ea. -
Power Output : 300W Max., 250W RMS at 10%
THD, 220W RMS at 5% THD, 200W RMS at 2%
Output Regulation : ≤ 2 dB, no load to full load at
Input Channels : 6 × Mic 0.65mV/4.7kΩ, 2 × Aux
100mV/470 kΩ, 1 × Line 1V/50kΩ
Frequency Response : 50-15,000Hz ±3dB
Signal to Noise Ratio : 60dB
Tone Controls : Bass: ±10dB at 100Hz, Treble: ±10dB
Outputs : Preamp 200mV/600Ω, Line 1V/1kΩ
Speaker Outputs : 4Ω, 8Ω, 70V & 100V
Digital Player : MP3 Player with USB, SD and MMC
Unidirectional Dynamic Microphone
SETC of Philips/Ahuja Make or equivalent
Multi Purpose Applications
All purpose PA microphone reproducing intelligible,
crisp and a bright sound
Suitable for multi-purpose PA installations.
Supplied with quick detachable holder with 3-pin
professional XLR connector & 6 mtrs. twin core
shielded low noise cable.
Frequency Response : 50-15,000Hz
Sensitivity : 2.2mV/Pa
Impedance : 500Ω
PA MICROPHONE STAND
SETC of Philips/Ahuja Make or equivalent
Microphone stand employ sturdy mechanism ensuring
trouble free movement and positioning of microphone.
These stands are functional and resistant to rust, due to
82 superior quality of chrome plating/powder coating. 0 2,109.48 Ea. -
stand with 5/8” 27 TPI to match all MICROPHONES.
Type : Floor Stand
Height : 920-1500 mm
Base Dia : 230 mm
Weight : 4.60kg
Sr. No. Description Qty. Rate Unit
Speaker Wire (Copper)
83 SETC of 1.5 Sq.mm. 2 Core Oxygen free Copper 0 126.27 Mtr. -
Providing and erecting ISI mark Medium class RIGID
PVC PIPES of following size complete to be erected
on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution
& Clamps with following dia of pipes, in approved
manner as directed. (a)20 mm
1 SETC of GI Pipe Pole | 6 m Long 0 5,470.00 Nos.
2 SETC of Bracket | single arm 0.5 m 0 973.00 Nos. -
3 SETC of Bracket | Double arm 0.5 m 0 1,364.00 Nos. -
4 SETC of Bracket | Triple arm 0.5 m 0 2,441.00 Nos. -
5 SETC of Bracket | single arm 1.0 m 10 1,586.00 Nos.
6 SETC of Bracket | Double arm 1.0 m 0 2,513.00 Nos. -
7 SETC of Bracket | Triple arm 1.0 m 0 3,308.00 Nos. -
Providing & Constructing 1:2:4 CC foundation of 6 m
long GI Pipe post
Supply and laying of GI "B" grade pipe for cable
guard/ road crossing with making of Zari for 40 mm Ø
Supply and laying of GI "B" grade pipe for cable
guard/ road crossing with making of Zari for 50 mm Ø
11 Cable end termination for 4 x 6 sq mm (Single Cable) 25 130.00 Nos.
Cable end termination for 4 x 10 sq mm (Single
SETC of 1.1 kV grade XLPE insulated Al conductor
armoured cable | 4 x 6 sq mm
SETC of 1.1 kV grade XLPE insulated Al conductor
armoured cable | 4 x 10 sq mm
Laying of cable with excavation of trench having
depth of 75 cms and refilling with clay and covering
with 38 mm Ø ID DWC pipe to be laid in | Soft soil/
Laying of cable with excavation of trench having
depth of 75 cms and refilling with clay and covering
with 38 mm Ø ID DWC pipe to be laid in | Hard
Murrum/ Asphalt Road
Laying of cable with excavation of trench having
depth of 75 cms and refilling with clay and covering
with 50 mm Ø ID DWC pipe to be laid in | Soft soil/
Laying of cable with excavation of trench having
depth of 75 cms and refilling with clay and covering
with 50 mm Ø ID DWC pipe to be laid in | Hard
Murrum/ Asphalt Road
Sr. No. Description Qty. Rate Unit
Supply & erecting PVC/ XLPE insulated ISI marked
unarmoured copper cable 1.1 kV grade | 3 x 1.5 sq mm
Supply & erecting PVC/ XLPE insulated ISI marked
unarmoured copper cable 1.1 kV grade | 3 x 2.5 sq mm
SETC of SMC press moulded composite FRP (Plastic)
loop- in, loop-out, dust & water proof, junction box,
mm thickness as per detailed specifications, terms &
conditions of the tender: -
S.E.T.C. of LED Streetlight Luminaires complete with
23 all accessories for Road having width of 12 m (Side 0 2,880.00 Nos. -
Arrangement) ≈ 40 W
SETC of CCMS with GI Box {Capacity 6 kW, 1 Ø} &
SETC of CCMS with GI Box {Capacity 9 kW, 3 Ø} &
S.E.T.C. of LED Streetlight Luminaires complete with
24 all accessories for Road having width of 18 m (Side 10 7,530.00 Nos.
Arrangement) ≈ 120 W
S.E.T.C. of LED Streetlight Luminaires complete with
25 all accessories for Road having width of 18 m (Central 0 5,310.00 Nos. -
Arrangement) ≈ 70 W
Painting the number and words for (streetlight pole
numbering and back ground of colour as per Zone
Code) inventory Identification with good quality of
enamelled paint up to 20 characters + 50 mm Height
Pipe type Earthing having 150 cms long and 2.5 cms.
Ø GI pipe with coupling and buch buried in specially
27 prepared earth pit complete with necessary 25 x 3 mm 0 990.00 Nos. -
size GI earthing strip using salt and charcoal/ coke as
required for pipe type earthing
Executive Engineer,
South Zone -A (Udhana)
Sign of Contractor Surat Municipal Corporation.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
07 - Technical Bid.pdf
07 - Price Bid.pdf
Download all tender documents and submit your bid