| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 UDYAM DL 01 0031798 | CENTRAL DELHI | DELHI | 110002 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹25.9 L+₹2.3 L (9.54%)Rejected-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹26.8 L+₹3.2 L (13.5%)Rejected-AOC NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹28.4 L+₹4.8 L (20.2%)Rejected-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC Not Lowest |
Tender Value
₹28.1 L
EMD Value
₹56,280
Closing Date
16 Mar 2023, 6:00 pmClosed
CWE HILLS DEHRADUN
HQ CWE HILLS, MALL ROAD, DEHRADUN CANTT - 248003.
REPAIR REPLACEMENT OF HT OVERHEAD DISTRIBUTION SYSTEM, REPAIR AND FILTRATION OF TRANSFORMER AND ALLIED WORKS AT RAIWALA UNDER AGE (I) RAIWALA
2023_MES_581684_1
86395/RWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) RAIWAL
Class D Category b(ii)
8 documents required · 8 mandatory
₹500
AGE I RAIWALA
₹56,280
Yes
1 Apr 2023
17 Feb 2023
23 Mar 2023
17 Feb 2023
16 Mar 2023
4 Mar 2023
Amount
Supply and filling insulating transformer oil confirming to IS 335 1993 for replacing in distribution transformer with dielctric strength not less than 60 KV complete all as specified and directed.
M&L for Filteration/ dehydration and cleaning of transformer oil off line by dehydration plant including testing of samples before and after dehydration and filtration, dielectric strength should not less than 55 KV at 2.5 mm gap after dehydration/filtration all as specified and directed. Note:- For running of filtration plant the arrangement of electric supply / DG set should be made by contractor and the cost of same deemed to be include in quoted rate.
M&l for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 32x6 mm GI strip as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI strip upto 7.5 mtrs long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items.
NOTE : (i) Cost of all the material, components, repairs, elements as per above as well as other elements (except supply only of the components considerd under items herein after to the extent required and operated ) to make the VCB complete functional shall deemed to be included in the quoted rate of the contractor. (ii)Individual Breaker VCB shall be considered as one unit and above job is to be carried out unitwise. Above job will be carried out by licenced technician as aproved by GE/AGE (I). (iii) Any accident/mishapenning occurred during the execution of work shall be responsibity of the Contractor. (iv) All necessary tools & plants required for carrying out above job will be provided by contractor and the cost of the same are deemed to be included in quoted rate. (v) Inventry of defective parts to be replaced by contractor will be prepared by joint inspection with contractor.
Supply only gear box and charging motor 110V suitable for HT 11 KV out door VCB AC three phase 50Hz complete all as specified and directed.
Supply only single phase circuit spout RYB phase suitable for HT 11 KV VCB AC three phase 50Hz complete all as specified and directed.
M&L for detecting cable fault in HT 11 KV cable by 24hrs x 7days ie entire contract period with technician and desired equipments at Mil station Raiwala and Mil camp area Narendra Nagar with and including necessary earth work (excavation & returning filling) in any type of soil, joint the cable fault with new straight through jointing kit complete all as specfied and directed. Note : (i) Cable joint of required size measured and paid separately. (ii) Each job considered cable fault locator use in one day in any any length of cable.
S&F cable jointing kit 11 KV (Earthed) grade cable for outdoor straight through heat shrinkable type joint complete with jointing material and accessories suitable for 95 Sqmm, 3 core XLPE armoured aluminum conductor cable complete all as specfied and directed.
S&F in repairs cable jointing kit 11 KV (Earthed) grade cable for indoor termination Cold shrinkable type joint complete with jointing material and accessories suitable for 95 Sqmm 3 core XLPE armoured aluminum conductor cable complete all as specfied and directed.
S&F in repairs cable jointing kit 11 KV (Earthed) grade cable for outdoor termination Cold shrinkable type joint complete with jointing material and accessories suitable for 95 Sqmm 3 core XLPE armoured aluminum conductor cable on HT pole, transformers etc complete all as specfied and directed.
S&F in repair including installation, commissioning and testing of HT 11 KV outdoor type gang operated triple pole air break switch suitable for Horizontal or vertical mounting fixed type complete with 12 insulator 400 amps rating and steel frame mechanically oprated mechanism consisting of operating rod of 25 mm bore light grade GI pipe of suitable length worked from ground level and with locking arrangement flat iron clamp 50mm x 6mm including MS channel of suitable size length for fixing GOD including bolts, nuts and washer complete all as specified and directed.
Dismantling and taking out old unserviceable ACSR conductor of any size complete all as specified and directed.
Supplying, streching and fixing of over head ACSR conductor any size ie. weasel, Ferret and Dog and any type fixing on steel tubular pole including binding/ jointing the conductor to insulator with and incl 14 SWG binding wire complete all as specified and directed.
Restreching/ restringing only over head ACSR conductor / earth wire of any size and type comprising of one conductors/wire over steel tubular poles, incl opening, streching, binding and jointing the conductor to insulater with and incl 14 SWG binding wire and tape the jumper complete all as specified and directed.
S&F in repairs pin type, porelain, vitreous, white brown or green insulator 11000 volts grade of size 150 mm height, 150 mm dia, including galivanized mild steel spindle with two galvanized iron washers and one galvanized nut bolt complete all as specifed and directed.
S&F in repairs disc type insulator, procelain vitreous, 145 mm high and 255 mm dia ball and socket type, white or brown or green, single disc assembly for tension wtih tension clmps for conductors, working pressure 11000 volts complete all as specified and directed.
Dismantling and taking out old unserviceable four pole structure of any type and any size including clamps insulators, cross arms etc of any type complete all as specified and directed.
Dismanlting and taking down bend/damaged mild steel work such as cross arms, bracing, supported, clamps & back plates etc complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed including of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
M&L for painting of steel tubular HT Pole 11 mtr long, two pole structure and mild steel work such as cross arm, clamps, nuts, bolts, etc including preparation of old painted surface and painting two coats of aluminium paint including 5 Nos band/straps with yellow and black colour in alternatete way (250mm wide each) synthetic enamelled paint two coat at a distance 300mm from plinth block and marking pole nos with black synthetic enamelled paint complete all as specified and directed.
M&L for painting of steel tubular HT Pole 11 mtr long, four pole structure and mild steel work such as cross arm, clamps, nuts, bolts, etc including preparation of old painted surface and painting two coats of aluminium paint including 5 Nos band/straps with yellow and black colour in alternatete way (250mm wide each) synthetic enamelled paint two coat at a distance 300mm from plinth block and marking pole nos with black synthetic enamelled paint complete all as specified and directed.
Disconnecting and taking out existing old unserviceable HT cable of any size from trenches/from pole/walls including taking out old GI tubes, cable protection covers, etc complete all as specified and directed.
S&F/Laying, connecting and testing of HT cable XLPE insulated screened PVC badded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 11KV (Earthed) as per IS 7098 (Part-II) with stranded aluminium conductor of following size complete all as specified and directed:- Note:- (i) The earth work, GI pipe shall be measured and paid sepretely. (ii) Cable may fixing/ passing through pipe laid in trenches or fixed to pole/ wall or fixed to LT panel etc. (iii) ACSR conductor & cross arms replaced with UG Cable.
95 Sqmm, 3 core.
Excavation in trenches in any type of soil not exc 1.5 m wide and not exceeding 1.5m in depth for laying UG cable/ foundation etc complete all as specified and directed.
Returning filling in any type of soil including spreading levelling watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed.
Removal of excavated surplus hard/dense soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thicness of sand will be measured and paid sepetarely under relevent item of Sch.
Supply and laying un-reinforced precast concrete cable cover of class HVP, type-1 with peak, size 300mm x 180mm x 40mm (ISI marked) for protection of UG cable over sand cushoniing laid in trenches with axis of the cover perpendicular to the axis of the cable complete all as specified and directed.
M&L for road cutting of size min 15cm width x 10cm depth for laying of cable including making good the road with PCC (1:3:6) type C1 complete all as specified and directed.
S&F galvanized steel water tubing (GI Pipe) light grade (ISI marked) with all fittings as in sleeving for cable protection & laid in trenches/ floor or fixed to wall, ceiling and pole of following bore complete as specified and directed :- Note : MS Clamp, nut bolts and washer shall be measured and paid seperatly for fixing with pole etc.
80mm bore
S&F in repairs cast iron cable route indicator having min dia 120mm and thickness of plate not less than 6mm, embossed 11KV HT of bold letters, welded on 2 feet MS angle iron of size 40/40 mm on plates including grounding 1.5 feet under ground and PCC complete all as specified and directed.
S&F in repair PG clamp suitable for any size of ACSR Conductor complete all as specified and directed.
S&F in repair Rubber mat of size 1m x 2m x 12mm of ISI marked for operating voltage of 11 KV and di-electric strength 45 KV complete all as specified and directed.
Supply only DO fuse of following capacity complete all as specified and directed :-
S&F in repair anti climbing devices, spike type, fabricated out of MS bar (round, square or flat) including nuts bolts washers and welding in two halves made of shape to suit the cross section of pole complete as specified and as directed.
S&F in repair Danger Notice Plate of 1.6 mm thick mild steel sheet, vitreous enamelled white with letters in English and regional language, figures and conventional skull and bones in signal red colour and fixed with 2 Nos MS clamp of size 25 x 3mm, bolts and nuts of approved size for following size complete all as specified and as directed :-
Size 25 x 20cm for HT
Size 20 x 15cm for LT
Supply, installation, testing and commissioning of 11 KV/12 KV, 630 Amps Non extensible, outdoor type, 3 Way RMU panel with 1 isolators and 2 VCB, SF6 gas insulated, 11 KV Ring Main Unit contained within stainless steel tank suitable for outdoor use free standing and comprising of : (A) (i) 2 Nos - 630 Amp triple pole, manually operated vaccum circuit breaker encapsulated in SF6 stainless steel tank with independent spring mechanism and fully rated earth switch with provision for earth of the cable. (ii) 2 Nos - Air insulated cable boxes with split gland plate suitable for front side bottom entry 3 core cable upto 300 sqmm. (iii) 1 Nos - 630 Amp triple pole, single break, 3-position ('ON', 'OFF' and 'EARTH') ring main switches, each with independent manual charged spring mechanism and fully rated earth switch with provision for earth and test of the cable. (iv) 1 Nos - Air insulated cable boxes and glands suitable for front and bottom cable entry 3 core cable upto 300 Sqmm.
(B) The Ring Main Unit (RMU) should comprise of the following accessories : (a) 1 Mimic diagram on front panel complete with status indicators. (b) 1 Set of positive standard mechanical interlocks. (c) 2 Set of current transformers for metering and protective relays 100/50/1A, 2.5 VA, 5 P 10 class. (d) 2 Nos- self powered Numerical relay with 3 o/c and E/F. (e) 2 Nos- Master trip relay with auxilary relays for transformer fault indication. (f) 2 Nos. Trip circuit supervision relay with auxiliary relays for transformer fault indication. (g) 1 Nos. Power pack equipment with backup of 15 minutes for operation of relays. (h) 3 Set of LED indicator lamps for cable live indicator. (j) Potential transformer 11KV/R3//110/R3//110/R3 - accuracy class 0.5/3P Burden with HT fuse and auxiliary PT 11 KV/230 V AC 500 VA. (k) 1 No. digital mutifunction meter, 3 line display. (l) 1 No. External stud for earthing connections. (m) 2 Nos. SF6 gas pressure indicator. (n) 3 Nos. local 'PULL TO TRIP' mechanism. (o) 1 No. operating handles. (p) 1 Set copper bus bars common for outgoing feeders. (q) Manual charging for operation arrangement. (r) Fuses for metering and protection system. (s) Front bottom entry of HT cables. (t) Paint finish - All steel work will be finish painted in Dark grey shaded 632 as per IS.
(C) RMU Panel should have following general characteristics: (i) Enclosure degree of protection - IP54. (ii) Type of Ventilation - Natural (iii) Rated Enclosure - IK 10 (iv) Rated power frequency withstand voltage KV RMS/min - 28/38 kv (v) Rated lighting impulse withstand Voltage kv, 1.2/50 micro sec - 75/95 kv (vi) Short time current rating ka, for sec - 21 kA/3 sec. (vii) Rated short circuit making current - 50 kA. (viii) Reference standard - As given in PS. NOTE :- Necessary drawing shall be got approved before placing order and PDI including testing shall be carried out by the rep of accepting officer. The cost of PCC platform for mounting RMU panel as per manufacturers instruction is deemed to be included in the quoted rates. The quoted rates must include the cost of cable termination kit cold shrikable type, cable glands, outside panel, cable lugs, cable trenches etc., cable between RMU & metering cubicals, lugs & glands & arrangements for 1 run / phase.
Supply only Driver for LED Street Light for following wattage complete all as specified and as directed :-
KAPOOR ELECTRICALS
BK CONSTRUCTION
Ansh Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .