| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹35.8 L+₹70,624.74 (2.01%)Rejected-Finance R O Y K PURA QAZIGUND ANANTNAG 192221 J K | ANANTNAG | JAMMU AND KASHMIR | 192221 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹38.4 L+₹3.2 L (9.23%)Rejected-Finance HOUSE NO 97 MOHALLA AFGHANA GALI KRISHAN DWARA JAMMU | JAMMU | JAMMU | JAMMU AND KASHMIR | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹38.7 L+₹3.5 L (10.1%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹38.8 L
EMD Value
₹77,680
Closing Date
3 Apr 2025, 6:00 pmClosed
Garrison Engineer Kargil
Office of GE Kargil, PIN - 908121, C/o 56 APO
TOKEN NO. GE/K-85/2024-25 - SPECIAL REPAIR OF LT UG CABLE, OVERHEAD CONDUCTOR AND ALLIED ITEMS AT CERTAIN UNITS AT KARGIL AND BUDHKHARBU UNDER GE KARGIL
2025_MES_700341_1
TOKEN NO. GE/K-85/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kargil
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Kargil
₹77,680
Office of GE Kargil
13 Jun 2025
5 Mar 2025
5 Apr 2025
5 Mar 2025
3 Apr 2025
20 Mar 2025
12 Mar 2025
Amount
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m
Dismantling insulators any type, any size as directed by EIC
Dismantling of ACSR any type, any size as directed by EIC
Dismantling of steel tubuler swaged poles of any length complete with cost iron base plate including necessary demolition and excavation complete all as specified and as directed
Taking out defective XLPE / PVC cable of any size and type from trenches / walls / under floor etc , including PCC cable cover complete all as specified and as directed by the Engr-in-Charge. Note :- (i) Excavation and earth work shall be included in quoted rate . (ii) Unit rate of this item also includes the removal of bricks / tile as cable protection GI, pipe and cable joint kit etc. and nothing extra shall be admissible on this acoount (iii) After taking out of cable from the trenches, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account
Dismantling and taking out the old stay assembly incl demolition of plain cement concrete all as specifiede and as directed by the Engr in charge . Note (i) unit rate of this item includes the loose/disconnect the all accessories which are connected to stay assy including necessary excavation as directed (ii) Existing stay assembly are fixed on the LT/HT pole of PCC or steel tubuler pole , nothing extra shall be paid on this account
S&F PVC line seperator for separating 3/4/5 LT overhead lines all as specified by the Engr in charge.
Material and Labour for stay assembly complete with accessories as shown in electrical plate No 1 including GI Adjustable stay rod of 16 mm dia, GI stay wire of size 7/4 mm incl stay clamps, excavation in any strata and PCC 1:3:6 concrete complete all as specified and directed by the Engr in charge. Note Unit rate of this item includes the cost of earth work, loop type insulator, PCC and stay wire
Excavating in trenches hard/dense soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
Sand cushioning with fine sand under cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 size 250 mm x 150 mm x 40 mm
Supply, transporting, erecting and fixinng steel tubular poles type SP-31 (9 meter long) complete with cost iron / mild steel base plate, finial taper plug , bolts, nuts & screwed as specified including necessary excavation and earth work , PCC 1:4:8 type D-2 in foundation & around poles and PCC 1:2:4 type B1 as in plinth, block , (coping of pole ), disposal of surplus soil to a distance not exceeding 50 meter and depositing where directed , painting steel tubuler poles exposed surface with two coats of aluminium paint over one coat of red oxide primer and making five nos aletrnative white and black strip 30 cm height upto 1.5 meter height from top of PCC coping with sythentic enamel paint and numbering of pole complete with painting of embeded portin with two coat of bituminous paint complete all as specified.
S&F ACSR conductor of (ferret) 6/3.00, stretching properly on insulator and binding with aluminium binding wires, jumpers including fixing on insulators on each pole in span and tightening with permissible sag in between span etc complete all as specified and as directed.
S&F ACSR conductor of (Rabbit) 6/3.35, stretching properly on insulator and binding with aluminium binding wires, jumpers including fixing on insulators on each pole in span and tightening with permissible sag in between span etc complete all as specified and as directed.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engr-in-Charge.
S&F pin type composite/polymer insulator incl one galvanised MS spindle, two washers and one galvanised iron nut, 100 mm height, 65mm dia for 1100 volts grade fixed on poles/cross arms of upto 9 M long complete all as specified and as directed.
S&F shackle type composite/polymer insulator incl one galvanised mild steel straps washers and nuts for working pressure 1100 volts section of strips 31 x 5 mm bolt dia 14 mm max dia 115 mm, height 100 mm, fixed on poles / cross arms of upto 9 m long complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed
M&L for Earth continuity conductor or main earthing lead fixed to poles or any other indicated situation for loop earthing etc. as required 8 mm dia galvanised iron or steel wire complete all as specified and as directed by Engr-in-charge.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 sq. mm 3.5 core
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 sq. mm 3.5 core
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 sq. mm 3.5 core
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 sq. mm 3.5 core
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq. mm 3.5 core
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3.5 core
XLPE insulated, armoured heavy duty electric cable with luminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core
XLPE insulated, armoured heavy duty electric cable with luminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 2 core
Supply and laying as in repairs GI tubing medium grade incl accessories for passing of cables for mechanical protection , laid under plinth / floors / paths culverts of following size.
(a) 80 mm bore
(b) 40 mm bore
Supply,installation, commisioning and testing in replacement of factory made (CPRI approved from make listed in Particular Specification) LT panel board of suitable size out door type (double dore) 415 volts,dust proof, vermin proof, made out of CRCA sheet 3.15 mm thick duly compartmentalised inside panel with 2 mm thick CRCA sheet, to accommodate the incoming and outgoing each switch gear shall have be independent opening, and having provision for front and rear side opening with rubber beading and brass cable glands for each cable to make it weather and vermin proof. double door hinged type , both side openable , air fins for ventilation , panel shall be mounted on angle of size (50x50x6 mm) & duly spray painted with seven tank process internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer supported on 04 legs of suitable long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 (using 20mm graded stone aggregate) or as manufacturer instruction and including notice board & danger plate complete with all connection incoming/outgoing complete all as specified and as directed by Engr-in-Charge. Comprising of following accessories :- IN COMING (a) MCCB 4 pole 250 amps , 415 volt of breaking capacity not less than 25 KA(lcs=100% of lcu) with adjustable thermal setting - 01 No for incoming. (b) Aluminium bus bar 300 Amps current rating duly sleeve insulated for set of 3 phase , 4 wire system 01 Set. OUTGOING (c) MCB 4 Pole 125 Amps, 415 Volts breaking capacity not less than 25 KA (lcs = 100% of lcu) with adjustable thermal setting -03 Nos. (d) Volt meter range 0-500 volt - 01 Nos. (e) Ammeter range 0-600 amps with suitable CTs - 01 Nos. (f) LED indicator Lamps R,Y,B - 01 Set.
Note : Deduction for amount of Rs. 1,63,090.00 as listed in Schedule 'A' Part-II (Schedule of Credit) shall be made while awarding of contract.
M/S BHAT ENGINEERS (BID ID -3275373)
M/S RAVI KUMAR (BID ID -3276163)
SUMEET TRADING CORPORATION (BID ID -3271648)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .