| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹56.9 LAccepted-AOC | 1 | Accepted-AOC awarded | |
| 2 | 2₹59.2 L+₹2.3 L (4.02%)Rejected-Finance NAIN BHAWAN BALVEER COLONY NEAR HOTEL BALSONS URBAN ESTATEB BYE PASS ROED PATIALA DISTT PATIALA | 2 | Rejected-Finance high bidder | |
| 3 | 3₹72.4 L+₹15.5 L (27.3%)Rejected-Finance 38 ABOVE OLD SYNDICATE BANK MAIN BAZAAR MANSA 151505 | MANSA | PUNJAB | 151505 | 3 | Rejected-Finance high bidder |
| Sl No | Description | Qty | Unit | APEX CONSTRUCTIONS L1 | GMSM INFRA BUILDCON LLP L3 | GULADI INFRA PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling brick work tile, masonry or tile lining in cement. | 25 | cum | 718.49 ₹17,962.25 Lowest | 900 ₹22,500 | 750 ₹18,750 |
| 2.00 | Dismantling Reinforced concrete | 4 | cum | 2,321.91 ₹9,287.64 Lowest | 3,150 ₹12,600 | 2,424 ₹9,696 |
| 3.00 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. | 2,000 | cum | 73.4 ₹1,46,800 Lowest | 175 ₹3,50,000 | 150 ₹3,00,000 |
| 4.00 | Preparing, watering and ramming surface for laying concrete. | 1,300 | sqm | 28.44 ₹36,972 Lowest | 109 ₹1,41,700 | 42 ₹54,600 |
| 5.00 | Cement concrete (M-10) with stone ballast mixing by mech. Means using concrete mixer volumetric type. | 150 | cum | 4,739.81 ₹7,10,971.5 | 4,700 ₹7,05,000 | 4,300 ₹6,45,000 Lowest |
| 6.00 | Plain cement concrete in sub-structure complete as per drawing and Technical Specifications. For PCC M-15 Grade. Using Batching Plant, Transit Mixer and Concrete Pump, i/c shuttering and vibrating etc but excluding steel reinforcement complete in all respect. | 35 | cum | 5,484.53 ₹1,91,958.55 | 5,300 ₹1,85,500 | 4,900 ₹1,71,500 Lowest |
| 7.00 | Plain Cement Concrete 1:4:8 with stone ballast mixing by mechanical means using concrete mixer volumetric type | 31.05 | cum | 4,454.48 ₹1,38,311.6 | 4,300 ₹1,33,515 | 4,000 ₹1,24,200 Lowest |
| 8.00 | Supplying & laying dry brick ballast. | 2.49 | cum | 1,539.16 ₹3,832.51 | 1,950 ₹4,855.5 | 1,500 ₹3,735 Lowest |
| 9.00 | Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications for RCC M-20 grade, using concrete mixer but excluding steel reinforcement shuttering and vibrating complete in all respect. | 10 | cum | 5,800 ₹58,000 | 5,950 ₹59,500 | 5,600 ₹56,000 Lowest |
| 10.00 | Reinforced cement concrete M-30 mechanically batchmixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth | 150 | cum | 6,500 ₹9,75,000 | 6,950 ₹10,42,500 | 6,400 ₹9,60,000 Lowest |
Tender Value
₹61.9 L
EMD Value
₹1.2 L
Closing Date
21 Oct 2025, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Faridkot Canal and GW Division WRD Punjab Faridkot
Estimate for Reconstruction of Fall cum bridge with HR of 6R minor at RD 85750 of Kokri distributory
2025_WR_151138_1
Estimate for Reconstruction of Fall cum bridge with HR of 6R minor at RD 85750 of Kokri distributory
Open Tender
Civil Works - Canal
Item Rate
90 days
JAGROAN
Pre Qualification Details
2 documents required · 2 mandatory
₹1,000
Yes
₹1.2 L
Yes
Faridkot
17 Dec 2025
30 Sept 2025
21 Oct 2025
30 Sept 2025
21 Oct 2025
30 Sept 2025
6 Oct 2025
Amount
Dismantling brick work tile, masonry or tile lining in cement.
Dismantling Reinforced concrete
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Preparing, watering and ramming surface for laying concrete.
Cement concrete (M-10) with stone ballast mixing by mech. Means using concrete mixer volumetric type.
Plain cement concrete in sub-structure complete as per drawing and Technical Specifications. For PCC M-15 Grade. Using Batching Plant, Transit Mixer and Concrete Pump, i/c shuttering and vibrating etc but excluding steel reinforcement complete in all respect.
Plain Cement Concrete 1:4:8 with stone ballast mixing by mechanical means using concrete mixer volumetric type
Supplying & laying dry brick ballast.
Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications for RCC M-20 grade, using concrete mixer but excluding steel reinforcement shuttering and vibrating complete in all respect.
Reinforced cement concrete M-30 mechanically batchmixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Reinforced cement concrete M-25 mechanically batchmixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Furnishing and Placing Reinforced cement concrete in super- structure as per drawing and Technical Specification for RCC M-40 grade for anti crash barrier, Using Batching Plant, Transit Mixer and Concrete Pump, i/c shuttering and vibrating etc but excluding steel reinforcement complete in all respect.
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical and bartering including attached pillasters buttresses etc). Complete in all respect.
Extra for laying earth/ fly ash as per specification for compaction in 20 cm layers, dressing, watering & rolling to specifictions. Complete as all respects.
Re-handling of Earthwork with lead 30 meters
Providing and filling joint sealing compound with coarse sand and 6 percent bitumen by weight complete as per drawings and technical clause 2605 of MORT&H specifications.
Providing & fixing 25 mm thick and 250 mm wide compressible fiber board in expansion joint complete as per drawing and technical clause 2605 of MORT&H specifications.
Supplying, fitting and placing HYSD bar reinforcement in sub- structure complete as per drawing and Technical Specifications.
Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm.
Hazard Marker sign board 300x900mm rectangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 09 and IRC 67 2012,
Providing and fixing Structural Steel work complete in all respects and to entire satisfaction of Engineer-in-charge.
Water Arrangements
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth.
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
10 mm thick plaster with cement mortar 1:3 on walls
Any other Item
GULADI INFRA PRIVATE LIMITED (BID ID -689400)
GMSM INFRA BUILDCON LLP (BID ID -693307)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.48 MB
Tendernotice_2.pdf
PDF • 0.62 MB
BOQ_306121.xls
BOQ • 0.32 MB
Corrirendumrd85750kokri.pdf
PDF • 0.21 MB
Corrirendumfall85750kokri.pdf
PDF • 0.19 MB
corrigendumSBDnew.pdf
PDF • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .