| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹33.7 L+₹3.5 L (11.5%)Rejected-AOC | L2 | Rejected-AOC Not being lowest bidder | |
| 3 | L3₹34.5 L+₹4.3 L (14.1%)Rejected-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-AOC Not being lowest bidder | |
| 4 | L4₹35.7 L+₹5.4 L (17.9%)Rejected-AOC | L4 | Rejected-AOC Not being lowest bidder | |
| 5 | L5₹38.7 L+₹8.4 L (27.9%)Rejected-AOC | L5 | Rejected-AOC Not being lowest bidder |
Tender Value
₹41.5 L
EMD Value
₹93,000
Closing Date
31 Jul 2020, 6:00 pmClosed
GE I R nd D West Bengaluru
GARRISON ENGINEER I R nd D WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
OUTSOURCING OF SERVICES FOR OPERATION AND MAINTENANCE OF HT / LT INSTALLATIONS nd REPAIRS, REPLACEMENT OF INTERNAL AND EXTERNAL ELECTRIFICATION AT LRDE BANGALORE
2020_MES_355840_1
GE(I) R ND D (WEST)/BAN/27 OF 2020-21 8824E8
Open Tender
Manpower Supply
Item Rate
330 days
Bengaluru
Class and Category as per NIT
8 documents required · 8 mandatory
₹500
GE I R nd D West Bengaluru
₹93,000
Yes
28 Aug 2020
3 Jul 2020
6 Aug 2020
4 Jul 2020
31 Jul 2020
20 Jul 2020
4 Jul 2020 - 18 Jul 2020
Amount
Works to be carried out
Providing services for operation, maintenance of electric supply installations including internal electrification of all buildings, Old MED, ADMIN, RADAR, QRAD & DRC, Sub stations, operation of street lights, perimeter lights, post top lanterns, etc., by deploying skilled, qualified persons having experience in handling similar equipments/services and periodical maintenance to equipments, maintaining log sheets, complaint register, maintenance register, breakdown register etc including Sundays / Holidays complete. The scope of work/services to be provided by contractor in each shift are brought out in Schedule 'A' and Particular Specifications, and number of persons to be deployed in each shift in day shall be as under :- Three shifts (First shift comprising of one Electrician and one Helpers from 0600 Hrs to 1400 Hrs, Second shift comprising of one Electrician and one Helper from 1400 Hrs to 2200 Hrs and third shift comprising of one Electrician and one Helper from 2200 Hrs to 0600 Hrs) on all days including Sundays and Holidays.
Notes for Sl Item No 1.00 : (i) Details of equipment/services to be maintained are indicated as appendices in PS. (ii) The scope of work includes cleaning of working areas, equipments, sub-station buildings and maintenance of garden areas, (iii) Log sheet including proper recording of all operating parameters in the prescribed log book/register shall be maintained by the contractor in the installation for periodical check by the Engineer-in-charge. (iv) Manning of HT sub station consists of hourly monitoring, recording of readings prompt restoration of feeders at times of tripping and ensuring minimum down time. (v) Cleaning & carrying out periodical inspection of equipments like transformers HT/ LT panel boards 4/2 pole structures for uneven sounds and report the same to Engineer-in-charge immediately. (iv) Tenderer shall arrange insurance to his work-men and relevant proofs of the same shall be submitted to the department as and when demanded, the cost for the same is deemed to be included in the rate quoted. Responsibility of compliance of all the labour regulations in force lies with the tenderer.The provision of statutory laws relating to minimum wages, EPF, ESI payments shall be strictly adhered to by the contractor. (v) Absent from duty of technician is not permissible as E&M services essential in nature. However, the absence will invite penalty as described in Sch 'A' notes and recovery from bill shall be done through recovery statement.The tenderer will have no claim whatsoever on this account and decision of Accepting officer in this regard will be final and binding. (vi) Attention is drawn to minimum fair wages payable as notified (time to time) by Govt Of India / State Govt / Local body whichever is higher, including taxes as applicable and quote their rates accordingly. Contractor shall not have any claim on account of misunderstanding/under quoting in this regards.
Periodical checking, maintaining and attending all types of complaints connected with internal electrification, comprising of service connections OH / UG cables from respective feeder pillar boxes, checking of power DB's including tightening of connections, changing of burnt terminals, MCB's connectors, etc., checking of earthing of LT distribution system, measurement of earth resistance at earth pits, attending day to day complaints including checking and replacement of burnt out unserviceable items like wiring, connected fittings and fixtures, MCB DBs, ceiling fans, exhaust fans, replacement of tube rods of any capacity, wattage, choke, starters, point wiring, sub-main wiring, switch socket combination of any capacity, switches, fan regulators, capacitors, replacement of fuses, CFL bulbs, lamp holders, etc., or any other repair works all as specified and as directed in day time by deploying certified / skilled persons in general shift excluding Sundays and holidays (General Shift with two Electricians and two Helpers from 0800 Hrs to 1700 Hrs with one hour lunch break in between) in LRDE Technical Area). Notes : (i) Various items required for replacement are regulated by the department except those given under relevent items of schedule ‘A’ as supply only. However replacement cost of these items are deemed to be included in this item. (ii) The Items mentioned under relevent items of schedule ‘A’ shall be supplied by the contractor as and when required at site and the same shall be measured and paid under relevant items of Sch 'A'. Items given in Sch 'B' will be issued on requirement basis. However, the labour element for fixing of Supply only items under Sch 'A' and items issued under Sch 'B' is included in this item.
Notes for Sl Item No 2.00 (Contd.,) : (iii) Tenderer shall maintain relevant slips of complaints attended and materials used duly signed by users and any other documents as signed by dept and cost of the same is deemed to be included in the rate quoted. (iv) T&P, HT fuse wire and safety gear required for attending to the complaints will have to be arranged by the tenderer at no extra cost to the department. (v) Tenderer shall arrange insurance to his work-men and relevant proofs of the same shall be submitted to the department as and when demanded, the cost for the same is deemed to be included in the rate quoted. Responsibility of compliance of all the labour regulations in force lies with the tenderer.The provision of statutory laws relating to minimum wages, EPF, ESI payments shall be strictly adhered to by the contractor. (vi) Absent from duty of technician is not permissible as E&M services essential in nature. However, the absence will invite penalty as described in Sch 'A' notes and recovery from bill shall be done through recovery statement.The tenderer will have no claim whatsoever on this account and decision of Accepting officer in this regard will be final and binding. (vii) Attention is drawn to minimum fair wages payable as notified (time to time) by Govt Of India / State Govt / Local body whichever is higher, including taxes as applicable and quote their rates accordingly. Contractor shall not have any claim on account of misunderstanding / under quoting in this regards.
Supply only PVC insulated, PVC un-sheathed multi stranded heavy duty copper conductor FR cable 1.5 sq.mm size all as directed.
Supply only PVC insulated, PVC un sheathed multi stranded heavy duty copper conductor FR cable 2.5 sq.mm size all as directed.
Supply only PVC insulated, PVC un sheathed multi stranded heavy duty copper conductor FR cable 4.0 sq.mm size all as directed.
Supply only PVC insulated, PVC un sheathed multi stranded heavy duty copper conductor FR cable 6.0 sq.mm size all as directed.
Supply only PVC insulated/flexible copper cable 23/0.0052, 3 core 230 volts all as specified and as directed.
Supply only switch piano, flush type, 5/6 Amps single pole, 230 V, one way, complete all as specified and as directed.
Supply only fan regulator, electronic, stepped type, 230 V, complete all as specified and as directed.
Supply only Switch socket outlet combination, multi purpose, 2 in 1, 3 pin, 5 Amps, 230 V, flush type with gang box, complete all as specified and as directed.
Supply only Switch socket outlet combination, multi purpose, 2 in 1, 3 pin, 5 Amps & 15 Amps, 230 V, flush type with gang box, complete all as specified and as directed.
Supply only Switch socket outlet combination, multi purpose, 2 in 1, 3 pin, 5 Amps & 15 Amps, 230 V, flush type, complete all as specified and as directed.
Supply only fan capacitor of 2.5 Mfd suitable for ceiling fan single phase 230 Volts, complete all as specified and as directed.
Supply only fan capacitor of 4.0 Mfd suitable for exhaust fan single phase 230 Volts complete all as specified and as directed.
Fixing only, LED tube rod, 18/20watts, suitable for fixing to T8 FTL light fitting 36/40 W complete all as specified. Note : LED tube rod will be issued under Schedule 'B' free for fixing. Fixing element of tube rod is included in Sl Item No 2 here-in-before. The item is catered for accounting purpose of stores only, and hence nothing extra is payable under this item. Mode of measurement shall be EACH
Supply only wall mounted LED tube light fitting with lamp, 9/10 Watt, 2 feet, with high lumen output, environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, complete with diffuser, polyester louver with 9/10 watt LED tube & integrated electronic driver 9/10 W fitting as per cat No LUMILINEBS9WLED865SPCSS of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply only wall mounted LED tube light fitting with lamp, 18 / 20 Watt, 2 feet, with high lumen output, environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, complete with diffuser, polyester louver with 18 / 20 watt LED tube & integrated electronic driver 18 / 20 W fitting as per cat No LUMILINEBS20WLED865SPCSS of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply only, 42 W, LED, ceiling mounted, recessed high efficient luminaire, 2'x2', Ultra modern designed architectural LED luminaire which provides soft-light and glare free symmetrical illumination suitable for ceiling, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 120 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH , 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, prewired and connecting with 3 Core, 1 sq mm sheathed copper flexible cable, including lamps complete all as specified and directed. MAKE:- Cat No.VENUSNEOHE2X2PLR18-42WLED857MOD of Havells or techno-commercially equivalent model in Philips / CG / Syska complete with all accessories pre-wired, including tubes, connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.,
Supply only, LED high bay light fitting with high lumen output, environmental friendly, energy efficient LED, light fitting with lamps and accessories, IP 65 protection, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, along with fixture, 150 W lamp as per cat No RADIOSOHB150WLED75760DBOPC with driver of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply only T8 tube rod, 36/40 watts, 4 feet long, complete all as specified.
Supply only T8 tube rod, 18/20 watts, 2 feet long, complete all as specified.
Supply only tube light starter 230 Volts, single phase suitable for 20/36/40watts tube light fittings complete all as specified.
Supply only copper ballast. Suitable for 36/40 watts tube lights, 230 v, complete all as specified.
Supply only copper ballast. Suitable for 18/20 watts tube lights, 230 v, complete all as specified.
Supply only Electronic Ballast, 72 Watt, suitable for 2 x 36 Watts, 230 V, CFL fittings 4 pin type, complete all as specified.
Supply only Electronic Ballast, 36 Watt, suitable for 1 x 36 Watts, 230 V, FTL fittings, complete all as specified.
Supply only PL, CF lamp, 36 W, 4 Pin, complete all as specified.
Supply only Aluminium cable lugs of 50 sqmm, 3.5 core size all as directed.
Supply only Aluminium cable lugs of 70 sqmm, 3.5 core size all as directed.
Supply only Aluminium cable lugs of 95 sqmm, 3.5 core size all as directed.
Supply only Aluminium cable lugs of 120 sqmm, 3.5 core size all as directed.
Supply only Aluminium cable lugs of 150 sqmm, 3.5 core size all as directed.
Supply only Aluminium cable lugs of 185 sqmm, 3.5 core size all as directed.
Supply only Isolator four pole, 415 volts, 63 Amps, 50 Hz, complete all as specified and directed.
Supply only Isolator four pole, 415 volts, 100 Amps, 50 Hz complete all as specified and directed.
Supply only PVC casing/capping of 20 mm size ISI marked complete all as specified.
Supply only rigid non metalic PVC conduit of size 20 mm dia medium grade ISI marked complete all as specified.
Supply only ceiling rose three terminals white bakelite type complete all as specified.
Supply only sheet metal enclosure, single phase, 20 Amps, with MCB SP 20 Amps ('C' Curve, 230 Volts AC, 50 Hz, 10 kA, breaking capacity), with a two pin, earth plug and socket, complete all as specified.
Supply only sheet metal enclosure, three phase, 63 Amsp, with MCB TPN 63 Amps ('C' Curve, 415 Volts AC, 50 Hz, 10 kA, breaking capacity), with a three pin, earth plug and socket, complete all as specified.
Supply only sheet metal enclosure, three phase, 32 Amsp, with MCB TPN 63 Amps ('C' Curve, 415 Volts AC, 50 Hz, 10 kA, breaking capacity), with a three pin, earth plug and socket, complete all as specified.
Supply only MCB, SP, 50 Hz, 10-32 Amps current rating, 'C' series, 10 kA breaking capacity complete all as specified.
Supply only MCB, DP, 50 Hz, 32 Amps current rating, 'C' series, 10 kA breaking capacity complete all as specified.
Supply only, Four pole MCCB, 125 Amps, 16 kA, thermal magnetic release trip unit 415 Volt AC, 50 Hz, including connecting up incoming/ out going cables with suitable lugs and testing complete all as specfied and as directed.
Supply only Four pole MCCB, 100 Amps, 16 kA, thermal magnetic release trip unit 415 Volt AC, 50 Hz, including connecting up incoming/ out going cables with suitable lugs and testing complete all as specfied and as directed.
Supply only Four pole MCCB, 63 Amps, 16 kA, thermal magnetic release trip unit 415 Volt AC, 50 Hz, including connecting up incoming/ out going cables with suitable lugs and testing complete all as specfied and as directed.
M/S Sneha Enterprises
devan enterprises
C R R CONSTRUCTIONS
Pacific Enterprises
Solar Electricals and Electronics
Lucky Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .