Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹15.7 LAccepted-AOC JOGENDRA NAGAR AGARTALA WEST TRIPURA | AGARTALA | WEST TRIPURA | TRIPURA | L 1 | Accepted-AOC LOA accepted | |
| 2 | L 2₹19.6 L+₹3.9 L (24.6%)Rejected-Finance DHALESWAR JAIL ASHRAM ROAD AGARTALA TRIPURA W | DHALAI | TRIPURA | 799204 | L 2 | Rejected-Finance Rejected |
Tender Value
₹17.3 L
EMD Value
₹34,568
Closing Date
29 Nov 2022, 2:00 pmClosed
DGM, ED-II, Bordowali
O/O the DGM, ED-II, Bordowali, Agartala
Shifting of HT LT Line and sub-station from IOCL land near Kanchanmala rail bridge area under Electrical Sub-Division- Sekerkote New 1.2 km HT line from Tea garden to Rail bridge and 1.2 Km 11 kv line in composite with LT ABC and 10 span LT ABC f
2022_POWER_33532_1
NIT No- DGM/ED-II/TSECL/2022-23/12, dt. 04.11.2022
Open Tender
Electrical Works
Item Rate
90 days
Under ESD-Sekerkote
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
₹34,568
O/O the AGM, EC-I, Agartala
4 Jan 2023
5 Nov 2022
30 Nov 2022
5 Nov 2022
29 Nov 2022
23 Nov 2022
14 Nov 2022 - 18 Nov 2022
22 Nov 2022
Amount
(Supply & Erection)
Supply of fabricated M.S Channel (2.8 mtr long X100x50x50x6 mm) bkt.
Supply of fabricated M.S Channel (0.6 mtr long X100x50x50x6 mm) bkt.
Supply of fabricated M.S Channel (0.3 mtrX75x40x40x6 mm)
Supply of fabricated M.S Channel (1.2 mtrX75x40x40x6 mm)
Supply of fabricated M.S Channel (1.8 mtrX75x40x40x6 mm)
Supply of fabricated M.S Channel (2.2 mtrX75x40x40x6 mm)
Supply of fabricated M.S angle 1.5 mtr.X 65x65x6 mm)
Supply of fabricated M.S angle 2.5 mtr.X 65x65x6 mm)
Supply of MS Nuts & Bolts ( Assorted ) (As directed by the Engineer in charge)
Supply of Stay Clamp made by 50X6mm MS flat
Supply of Bracket Clamp made by 50X6mm MS flat
Supply of 3CX70+1CX16+1CX50sqmm,1.1Kv Grade LT AB Cable
Supply of Anchoring clamp with Al. Alloy bracket and stainless steel straps & buckles for 50-70sqmm insulated messenger wire.
Supply of Suspension Clamp with Al. Alloy bracket and stainless steel straps & buckles(For 50 - 70sqmm insulated Messenger).
Supply of Insulation Piercing Connector suitable for 16-70 sqmm(Main) & 4-50sqmm(Tap)
Supply of Elastomeric End caps (Range 16-70sqmm)
Supply of 3 Phase with street light Spring Loaded Service main distribution boxes(FRP) with stainless steel straps & buckles
Supply of 9 mtr long PCC Pole
Supply of 8 mtr long PCC Pole
Carriage of materials such as Cable.AAC, AAAC, ACSR, G.l.Wire,Cross-Arm,Stay Set.Insulators etc., by Mechanical Transport from the Electrical SubDivisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required, upto the lead of 25KM & 50KM. a) Upto the lead range 25KM
Back Carriage of. of 9.0 mtrs length of Steel Tubular Poles by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required a) Upto the lead range 25 KM (Beyond 8 (eight) poles)
Back Carriage of. of 8.0 mtrs length of Steel Tubular Poles by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required a) Upto the lead range 25 KM (For maximum 8 (eight) poles)
Back Carriage of 9.0mtrs length of P.C.C Poles by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis,including loading, unloading and stacking as reqd, a) Upto the lead range 25KM, (Beyond 4 (four) poles)
Back Carriage of 8.0mtrs length of P.C.C Poles by Mechanical Transport from Site to Workshop Vis-a-vis, including loading, unloading and stacking as required a) Upto the lead range of 25KM, (Beyond 5 (five) poles)
Back Carriage of materials such as Cable.AAC, AAAC, ACSR, G.l.Wire,Cross-Arm,Stay Set.Insulators etc., by Mechanical Transport from the Electrical SubDivisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required, upto the lead of 25KM & 50KM. a) Upto the lead range 25KM
Maintaining adequate clearance from overhead live conductors by Trimming of tree branches for Way Leaves
Dismantalling of 2.8 mtr long 100x50x50x6 Ms channel
Dismantalling of 2.8 mtr long 75x40x40x6 Ms channel
Dismantalling of 2.8 mtr long 65x65x6 Ms angle
Dismantalling of 2.2 mtr long 75X40X40X6 mm MS Channel
Dismantalling of 2.5 mtr long 65X55X6 mm MS Angle
Dismantalling of 0.8 mtr long 100x50x50x6 Ms channel
Dismantalling of 0.3 mtr long 75X40X40X6 mm MS Channel
Dismantalling of 0.3 mtr long 75X40X40X6 mm MS Channel
Dismantalling of 1.5 mtr long 65X55X6 mm MS Angle
Dismantalling of 5 wire C bkt made of 50X50X6 mm MS Angle
Dismantling of 11 KV Pin insulator along with Pin.
Dismantling of 11 KV Single Disc insulator set along with necessary fittings.
Dismantling of shackle insulator of size 75mm x 90mm /1OOmm x 15mm with straps & bolts/U clamp on pole
Dismantling of 11 KV 200 Amp. GOS unit set of three nos. including necessary connection .
Dismantling of 11 KV DOF unit set of three nos. including necessary connections
Dismantling of 11/0.430KV,3-Phase 63KVA of Distribution Transformer from Pole with necessary connections
Dismantling of 11/0.430KV,3-Phase 16KVA of Distribution Transformer from Pole with necessary connections
Dismantling of (Single Conductor) ACSR 6/1/2.59mm dia 'WEASEL' including Coiling etc. Complete as required.
Dismantling of 9 mtrs length of Steel Tubular POLE at any kind of soil . Including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in the ground level, ramming and making complete in all respect
Dismantling of 8 mtrs length of Steel Tubular POLE at any kind of soil . Including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in the ground level, ramming and making complete in all respect
Dismantling of 8Mtr. length of P.C.C POLE at any kind of soil , including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect
Dismantling of 9.0mtrs length of P.C.C POLE at any kind of soil including excavation of earth, refilling the pit with with soil upto the ground level, ramming and making complete in all respect
Dismantling Single Phase Service Connection with PVC cable from nearby Electrical pole to Premises i/c. G.l.Wire,Reel Insulator
Dismantling Three Phase Service Connection with PVC cable from nearby Electrical pole to Premises i/c. G.l.Wire,Reel Insulator.
Erection of 9.0mtrs length of P.C.C POLE at any kind of soil upto a depth of 1/6 th of pole height, including excavation of earth, refilling the pit with with soil upto the ground level, ramming and making complete in all respect.
Erection of 8Mtr. length of P.C.C POLE at any kind of soil upto a depth of 1/6 th of pole height, including pit with soil upto the ground level, ramming andexcavation of earth, refilling the making complete m all respect i/e.Hand-Cart carriage & Mannual carriage with necessary loading & unloading.
Erection of Stay set direct in earth complete with 19mm x 1800 mm long stay rod, anchor plate of size 300 x 300 x 8 mm ,thimble, turn buckle, 7/3.15 mm dia G.I Standed stay wire and stain insulator etc. with Supply of M.S.Clamp,Nuts & Bolts etc. as required. and making complete in all respect
Erection of M.S.Channel Cross-Arm,0.3Mtr. Long 75 x40 x 40 x 6 mm (Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm, 1.2 Mtr. Long 75 x40 x 40 x 6 mm (Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Angle Cross-Arm, 1.5 Mtr. Long 65 x65 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm, 1.8 Mtr. Long 75 x40 x 40 x 6 mm (Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm, 2.2 Mtr. Long 75 x40 x 40 x 6 mm (Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Angle Cross-Arm, 2.5 Mtr. Long 65 x65 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm exceeding 0.8 Mtr. Long 100 x50 x 50 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm exceeding 2.8 Mtr. Long 100 x50 x 50 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of 11 KV Pin insulator along with Pin.
Erection of 11 KV Single Disc insulator set along with necessary fittings
Laying & Stringing of 1 KM (Single Conductor) ACSR 6/1/2.59 mm dia 'WEASEL' including hoisting & binding etc. Complete as required.
Laying of 8 SWG GI wire at 300mm below the ground level for earthing of Sub-Station equipments from the earth electrode
Erection of 11 KV protective Guarding by GI wire 8 SWG as per technical speciñcation. across road/ River IT elecom line etc. in horizonta formation complete .
Erection of 11 KV 200 Amp. GOS unit set of three nos. including necessary connection complete asper technical specification.(Excluding the cost of back clamp.Nuts & Bolts)
Erection of 11 KV DOF unit set of Two nos. including necessary connection complete as per technical specification.(Excluding the cost of back clamp,Nuts & Bolts)
Erection of 9KV,5KA single pole metal oxide gapless type LA , including necessary connection complete as per technical specification
Installation/Positioning of 11/0.230KV, 1-Phase 63KVA of Distribution Transformer on Pole with necessary connections & fitting fixing of all allied accessories components as required for making complete in all respect for energizing.
Earthing with G. I pipe 2.5mtr. Long and 40mm dia, including excavation, refilling with alternate layer of salt & Charcoal as per drawing (excluding supply of G.l.Pipe, Salt & Charcoal, Gi wire, nuts &bolts, etc. as required)
Erection & Fitting-Fixing of Insulated Dead end enchoring Clamp including Pole clamp, Eye hook for cable massenger of 11KV grage on PCC/ Steel pole with the help of pole brackets or steel straps & buckles as per direction of Engineering ln-Charge.
Erection & Fitting-Fixing of Insulated suspention Clamp including Pole clamp, Eye hook for cable massenger of 1.1 KV grade on PCC/Steel Pole with the help Pole brackets or Steel Straps &buckles as per direction of Engineering ln-Charge.
Positioning of cable drum, removing of cable from drum and Laying, hoisting & drawing of AB Cable 3X70-95+1x16-25+1x50-95sqmm of 101 KV grade asper direction of Engineering ln-Charge
Fitting-Fixing of Service main 1 /3Phase distribution Box of 1.1 KV grade on PCC/Steel Pole with the help Pole brackets or Steel Straps &buckles as per direction of Engineering ln-Charge.
Erection & Fitting-Fixing of Insulation Piercing Connectors(IPC) all sizes of 1.1 KV grade including connection from main cable to Distribution box, Tee-Off line asper direction of Engineering lnCharge.
Providing Single Phase Service Connection with laying PVC cable from nearby Electrical pole to Premises upto 35mtr. in length supported by G.l.Wire,Reel Insulator i/c fitting fixing of Energy Meter as required .
Providing Three Phase Service Connection with laying PVC cable from nearby Electrical pole to Premises upto 35mtr. in length supported by G.l.Wire,Reel Insulator i/c fitting fixing of Energy Meter as required .
Erection of Barbed wire ( Anti climbing device) per pole
Erection of DANGER PLATE on OH lines (11 KV/415Volts)
ADHIR DEBNATH
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .