Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.5 LAccepted-AOC | ₹42.5 L Quoted ₹42.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹47.3 L+₹4.5 L (10.6%)Rejected-AOC 39 359 B PULICKAL THIRUVAMBADY POST ALAPPUZHA KERALA PIN 688 002 | ALAPPUZHA | ALAPPUZHA | KERALA | 688002 | ₹47.3 L+₹4.5 L (10.6%) | L2 | Rejected-AOC L2 |
| 3 | L3₹49.9 L+₹7.1 L (16.7%)Rejected-AOC CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | ₹49.9 L+₹7.1 L (16.7%) | L3 | Rejected-AOC L3 |
Tender Value
₹45.6 L
EMD Value
₹91,200
Closing Date
10 Sept 2024, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
CERTAIN SANCTIONED E/M WORKS UNDER GE EM NO I AND II.
2024_MES_663911_1
8351/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Kochi
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹91,200
Yes
6 Nov 2024
4 Jul 2024
12 Sept 2024
4 Jul 2024
10 Sept 2024
19 Jul 2024
4 Jul 2024 - 18 Jul 2024
Amount
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out in soft/loose soil for laying pipes etc, including forming bottom surface to required level complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point complete all as specified and directed.
Supply and laying 75mm inner dia of CPVC pipes with CPVC Sch 40 pipes & plain Sch 80 fittings and jointed with CPVC primer & solvent cement complete all as specified and directed.
Supply and fix in trenches high pressure CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings including all necessary fittings, solvents of size 50 mm dia complete all as specified and directed.
All as per item No 5 above but of size 25mm dia
Supply and fix in walls/ceiling or laying in floors high pressure CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings including all necessary fittings, solvents of size 50 mm dia complete all as specified and directed.
All as per item No 7 above but of size 25mm dia
Supply and fix CPVC Ball Valve of size 75 mm dia suitable for CPVC pipe including necessary fittings and complete all specified and directed.
All as per item No. 9 above but of size 50 mm dia.
All as per item No. 9 above but of size 25 mm dia.
Supply & Fix 1000 Litres capacity Rotational mould polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position including taking down unserviceable tank complete all as specified and directed.
All as per item No 12 above but 2000 Litres capacity.
Demolition of cement concrete (un reinforcement) in ground floors and paving not exceeding 15cm thickness, above ground level in inside the valve pits complete all as specified and directed.
Material and labour for plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and as directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Supply & Fix Pre-painted galvalume aluminium zinc coating GI based plain/corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided complete all as specified.
Supply & Fix Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, Fe-410-W (Grade- E-250) quality-A complete all as specified and directed.
Material & Labour for preparation of surfaces of new iron and steel surfaces and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer complete all as specified and as directed.
Taking down cement plaster on brick or stone wall etc. including raking out joints, hacking for keys, scrubbing down with water etc, complete all as specified.
Material & Labour for 15mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement mixed with water proofing compound (water proofing compound will be measured and paid separately) complete as specified and directed.
Supply only liquid water proofing compound.
Material & Labour for PCC 1:3:6 Type C2 20mm graded aggregate as in sub floor/floor/paving of 75mm thick complete all as specified and directed.
Material & Labour for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS:15658-2006 of 80mm thickness M-40 Grade with grey cement & no pigment etc, including 50mm thick bedding with 6 to 10mm graded coarse aggregate complete all as specified and directed.
Material & Labour for volumetric digital numbers marking over aluminium frame section 2 nos. of 125mmx37mmx2mm thick and length of frame not exceeding 3 metre fixing with fabrication etc complete all as specified and directed
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. and precast concrete articles complete as directed.
Excavation in over areas not exceeding 1.5 Metre depth and getting out in soft/loose soil including forming bottom surface to required level complete all as specified and directed.
Excavation in over areas exceeding 1.5 Metre and not exceeding 3 Metre depth and getting out in soft/loose soil including forming bottom surface to required level complete all as specified and directed.
Removing excavated material (soil) to a distance exceeding 250 Metre but not exceeding 500 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point complete all as specified and directed.
Material & Labour for slaked lime filling with excavated soil (mixed in the ratio of 40:60) under foundations including consolidation complete all as specified and directed
Material & Labour for hard core of broken stone of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick watered and rammed to a true surface complete all as specified and directed
Material & Labour for cement concrete 1:4:8 Type D2 (40 mm graded aggregate) in cement concrete in sub-floors, sub-bases, floors and paving, etc, complete all as specified and directed.
Material & Labour for formwork of sides of concrete foundations, footing, bases of column, raft and raft beams, side and soffits of foundation and plinth beam and similar work for fair finished surfaces complete all as specified and directed
Material & Labour for formwork of sides of columns and similar work for fair finished surfaces of concrete for square, rectangular, circular or polygonal complete all as specified and directed.
Material & Labour for formwork to sides and soffits of floor or roof beam, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. for fair finished surfaces complete all as specified
Material & Labour for RCC M-30 Design mix concrete using 20 mm graded stone aggregate as in footings, foundation beams; plinth beams, bases for columns, etc. and mass concrete complete all as specified and directed.
Material & Labour for RCC M-30 Design mix concrete using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed.
Material & Labour for RCC M-30 Design mix concrete using 20mm graded stone aggregate as in lintel beam/tie beams complete all as specified and directed.
Material and labour for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Material and labour for Mild steel TMT bars 5 mm dia over up to and including 10mm dia in stirrups, spacers and binders , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
Material & Labour for Precast cement concrete solid block masonry 1:3:6, type C1 using 20mm graded aggregate exceeding 10cm in width and setting cement mortar 1:6 complete all as specified.
Material & Labour for PCC Type B1 (1:2:4) using 20mm graded crushed stone aggregate as in coping benching and the like including weathering, slightly rounded or chamfered angles including necessary form work and finishing all exposed surfaces complete all as specified and directed.
Material & Labour for 15 mm thick rendering in cement mortar 1:6, on fair faces of brick work/ concrete finished even and smooth without using extra cement complete all as specified.
Material & Labour for preparation of new plastered external wall surface and applying two coats of weather proof coat (Apex/ Ultima) paint over a coat of primer complete all as specified and as directed.
Supply & Fix Framed work as in angle iron flange cut & made hole to run barbed wire or other section with gusset plates, and fixing including welding complete Fe- 410W Grade E 250 quality B complete all as specified and directed.
Supply & Fix Galvanised two strand steel barbed wire 2.24mm dia, barbed with 2.00 mm dia barbs at 75mm spacing, straining and fixing to any standard rails and straining bolts including securing or typing at crossing with and provisions of galvanised mild steel wire stapples or steel pins etc complete all as specified.
Supply & Fix concertina coil of 600mm diameter made out of core wire 2.5mm dia spring steel wire 275gm/m2 (minimum) dipped with corrosion preventive fluid (rusilo 901) of Castrol make in white colour each coil having a minimum 56 loops per coil/bundle with an average weight not less than 15.2 Kg (Plus or minus 5%)razor length minimum 22mm and tear blade thickness min 0.5mm including handle spikes at both ends of coil erected in position on top of compound wall (stretchable length of each coil 7 metre) complete all as specified and as directed.
Supply and laying cables in trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy-duty) with aluminium conductor, 11000 volts, grade having cross sectional area 3 core 300 sqmm complete all as specified and as directed.
All as per item No 49 here-in-above but sectional area 3 core 240 sqmm.
Supply and fixing of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240Sqmm to 300 sqmm complete all as specified and as directed.
Material & Labour for riddled sand filling in trenches for cushioning of HT/LT cables punning after filling complete as specified and as directed. Note: Punned thickness shall only be measured and paid
Supply and lay un-reinforced precast concrete cable cover, class, HV, Type I as per IS -5820 with flat size 300 x 180 x 40 mm laid dry in trenches over underground cables complete all as specified and as directed.
Material & Labour for 100 mm bore High density polyethylene pipes (HDPE) PN 10 laid in trenches/Wall/road crossing for suitable length as per sire requirement all as specified.
Supply, installation, and commissioning of 20KW UPS stand-alone Configuration, three phase in and out, (IP20), Input pf 0.99, it shall be 100% generator compatible, with Efficiency > 92 % and output power factor unity (20kVA = 20kW), including all accessories etc. as required, Isolation transformer built-in required at input side, The acoustic noise at 1m of the system should be <55Db,The system shall comply to IEC /EN 62040-1,2,3, and PEP certificates relevant IS standard along, The system shall be true online double - conversion DSP based UPS system and UPS shall be with automatic & manual bypass switch, The system shall have IGBT rectifier and inverter, including rack and interconnecting cables, and 30 Minute backup SMF battery of reputed approved for the above configuration 12v 100Ah 20 nos complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor of size 25 Sqmm 4 core complete all as specified and as directed.
Material & Labour for submain wiring along with earth wire with the 2 X 6 Sqmm PVC insulated copper conductor, single core cable in surface wiring through PVC conduit along with 1 X 6 Sqmm PVC insulated copper conductor single core for earth continuity cable complete all as specified and as directed.
Material and Labour for earthing complete with galavanised steel earth plate electrode 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of earth plate not less than 1.5 metre below ground level, connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolts, nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C 1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80mm thick RCC pit cover 320mm x 320mm of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinformed with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR part -I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point/ transformer neutral/body/ LT panel etc. and testing on completion, complete all as specified & directed.
Taking out existing outdoor type LT panel board with main switches, change over switch etc. after disconnecting the incoming and outgoing cables, earthing strips with angle iron frame etc and removing to store including transportation, loading, unloading etc complete all as specified and directed.
Supply, design, erection and commissioning of LT panel board outdoor type platform mounted fabricated through CPRI approved factory manufacturers, totally enclosed dust and vermin proof openable from both front and rear side made out of self-supported 3.00 mm thick CRCA (Cold Rolled Cold Annealed) MS sheet of suitable length, width and height as per IE rule to accommodate all the items and conforming to IS-8623 and built upon 40 x 40 x 6 mm size angle frame work and lugs fixed on existing cable trenches having front and rear hinged doors with neoprene rubber gasket, danger plate, GI earthing strips at rear side, bottom detachable gland plate complete with suitable size single plated and passivated nuts, bolts, spring washers. The cabinet and all members shall be chemically treated with MSR solution for air corrosive treatment and powder coated (shade RAL - 7032) with 9 tank process and shall be with IP-65 grade protection. The panel shall be suitable for 415 volts, 50 Hz 3 phase 4 wire system and internal connections which shall be provided with aluminium strips of suitable size and comprising of the following accessories complete all as specified and as directed. BUS BAR CHAMBER: (i) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid Aluminium bus bars, rated 630 Amps supported at required intervals sleeved with heat shrinkable PVC sleeving. The bars shall be colour coded at required intervals for identification - 01 No (Set of 04) SWITCH GEARS (i) MCCB, 4 pole, 400 Amps, 50 KA - 01 No (incomer) (ii) MCCB, 4 pole, 415 volts, 36 KA, 200 Amps thermal magnetic release, breaking capacity 36 KA - 02 Nos. (iii) MCB, 3 pole, 415 volts, 100 Amps - 02 Nos. (iv) Digital Street light timer - 02 Nos (v) Power Contactor 415 Volts, ML-4 - 02 Nos (vi) All electrical connections incoming and outgoing with proper cable glands.
Supply & Fix LED Flood Light 200W with cast aluminum housing, toughened glass cover, Mid power secondary optics, IP65/66, 10KV SPD, >100 lumen/watt, and wired with all accessories complete with base plate with bolts and nuts, on existing poles including connection to the electrical system compete all as specified and directed.
Material & Labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat of paint completed all as specified and as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor of size 10 Sqmm 4 core complete all as specified and as directed.
All as per item No 63 here-in-above but sectional area 4 core 16 sqmm.
All as per item No 63 here-in-above but sectional area 3.5 core 35 sqmm.
All as per item No 63 here-in-above but sectional area 3.5 core 70 sqmm.
Material & Labour for brick well burnt Class ‘B’ as cover to U/G cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over underground cable for cable protection in trenches complete all as specified and directed.
Material & Labour for GI tubing of size 40 mm dia medium grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc complete all as specified and directed.
All as per item No 68 here-in-above but GI tubing of size 50 mm dia.
Supply and fixing junction box made of thermoplastic of size 126x228x111mm with IP 67 protection including cable connector and MCB brackets including suitable size clamps fixing for four pole MCB pole/in PCC /wall foundation complete all as specified and directed.
Supply and fix MCB SP 6 Amp - 32 Amp "C" curve, 240/415-volt AC, as per IS/IEC complete all as specified and directed.
Supply and fix MCB TPN C series 40 Amp.
Supply and fix MCB TPN C series 63 Amp.
Supply & install, testing and commissioning of outdoor type LT panel suitable for 415 volts, 3 Phase 4 wire, 50 Hz AC supply system conforming to IS : 8623/93, floor mounted, factory made, weather and vermin proof, fully ventilated and fabricated out of angle iron 35mm X 35mm X 6mm thick frame work and CRCA sheet 3mm thick having Aluminum bus bar of rating 200 Amps, three phase and one neutral and electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. suitable size as per manufacturer mounted on angle iron stand made out of size 35mm X 35mm X 6mm grouted with PCC foundation complete of digital volt meter & Amps meter with CTs including front and back doors with locking arrangement complete all as specified and directed:- (a) Bus bar chamber of 3 phase and 1 neutral 4 strip 415 volts with 250 Amps aluminium strip - 1 Set (b) MCCB 160 Amp 50 KA 4 pole - 01 No ( Incoming) (c) MCCB 4 pole 40 Amp 16 KA 3 phase - 03 No (Outgoing) (d) MCCB 4pole 32Amp 16 KA, 3 phase - 03 Nos (Outgoing) (e) Energy meter 3 phase - 01 No (f) Volt meter digital 0-500 volt - 01 No (g) Amp meter digital 0-300 Amp - 01 No (h) Indicator lamp Yellow, Red, Blue - 01 Set
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
St George Engineering Works (BID ID -3092268)
M/s.Rejoy Constructions (BID ID -3084579)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .