Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 CrAccepted-AOC | ₹13.5 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹13.5 CrRejected-Finance | ₹13.5 Cr | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹13.5 CrRejected-Finance | ₹13.5 Cr | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹14.0 CrRejected-Finance UNIT B2 AUTONAGAR VISAKHAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530012 | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | ₹14.0 Cr | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹14.5 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹14.5 Cr | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹9.3 L
Closing Date
20 Feb 2021, 6:00 pmClosed
HQ CE Navy Visakhapatnam
HQ CE (Navy), MES, station Road, Visakhapatnam 530004
PROVN OF TRANSIT ACCOMMODATION FOR OFFICERS AT VISAKHAPATNAM
2020_MES_395087_1
CE (NAVY) / VIZ / TOKEN / 02 OF 2019-2020
Open Tender
Civil Works
730 days
VISAKHAPATNAM
as per NIT
8 documents required · 8 mandatory
₹3,000
GE P N Visakhapatnam
₹9.3 L
Yes
HQ CE Navy Visakhapatnam
15 Mar 2021
14 Nov 2020
22 Feb 2021
14 Nov 2020
20 Feb 2021
8 Feb 2021
14 Nov 2020 - 4 Dec 2020
30 Nov 2020
Amount
Schedule "A" Part – I to Schedule "A" Part – XVI: NOTE: Schedule "A" Part – I to Part – XVI are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "BUILDINGS & STRUCTURES", as listed in Schedule "A" Part – I
Lumpsum price worked out by the contractor for "SITE CLEARANCE / AREA DEVELOPMENT / EARTHWORK EXCAVATION", as listed in Schedule "A" Part – II
Lumpsum price worked out by the contractor for "PILE FOUNDATION", as listed in Schedule "A" Part – III
Lumpsum price worked out by the contractor for "COMPOUND WALL", as listed in Schedule "A" Part – IV
Lumpsum price worked out by the contractor for "ROAD / PATH / HARD STANDING/CHEQUERED TILE", as listed in Schedule "A" Part – V
Lumpsum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part – VI
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "RAIN WATER HARVESTING", as listed in Schedule "A" Part – VIII
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – IX
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – X
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – XI
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – XII
Lumpsum price worked out by the contractor for " LIGHTENING PROTECTION", as listed in Schedule "A" Part – XIII
Lumpsum price worked out by the contractor for " FIRE FIGHTING SYSTEM ", as listed in Schedule "A" Part – XIV
Lumpsum price worked out by the contractor for " FIRE ALARM SYSTEM", as listed in Schedule "A" Part – XV
Lumpsum price worked out by the contractor for "SOLAR WATER HEATER", as listed in Schedule "A" Part – XVI
Schedule "A" Part - XVII: [Miscellaneous Items] [Pile foundation, Internal Electrification, External Water Supply, External Electrification, Lightening Protection, Fire Fighting System, Fire Alarm System, solar Water Heater, Aviation light, DG Set, Arboriculture, Lift, ]:
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to galvanised iron strip 32 x 6 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts check nuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part I including charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 50mm dia light grade pipe for protection of earth electrode and 20mm dia pipe for watering all as specified and directed and tested on completion complete all as specified.
PILE FOUNDATION
Boring for bored cast in situ piles 600mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil to a distance not exceeding 10KM out side MD land using hydraulic rig method complete all as specified and directed.
Boring for bored cast in situ piles 600mm dia in hard rock & fractured rock and getting out and disposal of spoil to a distance not exceeding 10KM out side MD land using hydraulic rig method complete all as specified and directed.
Chipping out piles up to cut off level including disposal of spoil to a distance not exceeding 50M out side MD land all as specified and as directed.
Carrying out Initial load test on 600mm dia piles all as per IS - 2911 Part - IV .
Carrying out routine load test on 600mm dia piles all as per IS - 2911 Part - IV.
Carrying out initial lateral test on 600mm dia piles all as per IS - 2911 Part - IV.
Carrying out initial pullout test on 600mm dia piles all as per IS - 2911 Part - IV.
Carrying out low strain energy test on 600mm dia piles including analysing the results as per IS - 14893- 2001.
MS pipe liner fabricated out of 6mm thick plain MS plate confirming to Fe- 410 S grade E 250 quality 'A' by welding, lengthening wherever required, providing stiffeners, lifting hooks including all T&P as required, shifting the same from position to position required, driving in true vertical alignment in position to the required level for piles complete all as directed. NOTE : MS pipe liner shall be casted as mentioned in drawings. However for payment purpose the depth /height of liner shall be measured up to cutoff level only irrespective of the depth provided for retaining concrete/bentonite slurry. The unit rate quoted shall deemed to be included for the same.
INTERNAL WATER SUPPLY
S & F CP mixer for mixing hot and cold water screwed down for 20 mm PP-R pipe chromium plated , fancy type with two out going(one for bib tap and another for shower complete all as specified and as directed.
S & F Angle stop valve, chromium plated , fancy type , high pressure screwed and fixed suitable for 20mm PP-R pipe complete.
S&F Bib taps two way, fancy type with screwed down for size of 15 mm dia
S&F health faucet chromium plated , fancy type with steel flexible complete of size of 15 mm dia, length of 1 meter
INTERNAL ELECTRIFICATION
Material and labour Point wiring with 1.5 sqmm PVC insulated and unsheathed copper conductor cable multistranded 1100 volts grade, FRLS, ISI marked drawn through and including non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed including provn of pre fabricated pressed steel terminal box of suitable size made out of 1 mm thick sheets, for mounting modular brackets, including modular brackets and plates as required at site for fixing modular type switches, sockets, including one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly complete all as specified and directed. One light point controlled by one switch
Point wiring with 1.5 sqmm PVC insulated and unsheathed copper conductor cable multistranded 1100 volts grade, FRLS, ISI marked drawn through and including non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed including provn of pre fabricated pressed steel terminal box of suitable size made out of 1 mm thick sheets, for mounting modular brackets, including modular brackets and plates as required at site for fixing modular type switches, sockets, including one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly complete all as specified and directed. One bell point controlled by one bell push
Point wiring with 1.5 sqmm PVC insulated and unsheathed copper conductor cable multistranded 1100 volts grade, FRLS, ISI marked drawn through and including non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed including provn of pre fabricated pressed steel terminal box of suitable size made out of 1 mm thick sheets, for mounting modular brackets, including modular brackets and plates as required at site for fixing modular type switches, sockets, including one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly complete all as specified and directed. One fan (ceiling fan/Ex.fan) point controlled by one switch
Point wiring with 1.5 sqmm PVC insulated and unsheathed copper conductor cable multistranded 1100 volts grade, FRLS, ISI marked drawn through and including non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed including provn of pre fabricated pressed steel terminal box of suitable size made out of 1 mm thick sheets, for mounting modular brackets, including modular brackets and plates as required at site for fixing modular type switches, sockets, including one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly complete all as specified and directed. One 3 Pin socket outlet 6 amps socket on independent board
Point wiring with 4 sqmm PVC insulated and unsheathed copper conductor cable multistranded 1100 volts grade, FRLS, ISI marked drawn through and including non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed including provn of pre fabricated pressed steel terminal box of suitable size made out of 1 mm thick sheets, for mounting modular brackets, including modular brackets and plates as required at site for fixing modular type switches, sockets, including one run of 4 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly complete all as specified and directed One 3 pin socket outlet 15 amps socket on independent board
Point wiring with 1.5 sqmm PVC insulated and unsheathed copper conductor cable multistranded 1100 volts grade, FRLS, ISI marked drawn through and including non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed including provn of pre fabricated pressed steel terminal box of suitable size made out of 1 mm thick sheets, for mounting modular brackets, including modular brackets and plates as required at site for fixing modular type switches, sockets, including one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly complete all as specified and directed. but one light point controlled by two Nos two way switches complete all as specified and directed.
Supply and fixing LED adore lamp for AC 240Volt supply, B22 type, CDS five star, 10 watts of five star rated complete all as specified and as directed.
Supply and fixing telephone socket with and inclusive of prefabricated terminal box and plate for fixing telephone socket all as specified and directed.
Supply and fixing TV socket with and inclusive of prefabricated terminal box and plate for fixing TV socket all as specified and directed.
Supply and fixing/drawing PVC insulated telephone cable one pair on existing PVC conduits concealed to wall, of Havells make basic code No "WHTTATEL1P40 or equivalent make. Note : PVC conduit shall be measured separately
Supply and fixing/drawing PVC insulated telephone cable four pair on existing PVC conduits concealed to wall, of Havells make basic code No "WHTTATEL4P40, or equivalent make. Note : PVC conduit shall be measured separately
Supply and fixing PVC junction box of approx size 10cm x 15 cm rectangular type concealed to wall to accommodate PVC connector of four way for telephone cable.
Supply and fixing/drawing in concealed PVC conduit of CATV co-axial cables (Electrolytic grade solid annealed copper conductor, jelly field, Aluminium foiled and aluminium wire braided) of model RG 06 (foam) of Havells make or any other equivalent make. Note : (i) PVC conduit shall be measured separately. (ii) Note : Prior to drawing of telephone conduits/ TV conduits, the contractor shall take necessary approval of diagram from Engr-in-Charge.
Supply and fixing ceiling fan AC single phase 230 V of size 1200 mm sweep, copper wound with complete set and fixtures such as canopy, down rod etc. 5 Star rating, metallic body complete with and inclusive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specified and directed.
S&F Exhaust fan 250 mm sweep or nearest size, plastic body(Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the disturbed surfaces etc complete with and inclusive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specified and as directed.
S&F Exhaust fan 300 mm sweep , (Heavy duty),900 RPM, complete with louvers suitable for operation on 240 V AC, 50 Hz AC supply fixed on wall including making of necessary opening ,fixing and making good the disturbed surfaces etc complete with and inclusive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specified and as directed.
S&F Exhaust fan 380 mm sweep or nearest size, 900 RPM , (Heavy duty), complete with louvers suitable for operation on 240 V AC, 50 Hz AC supply fixed on wall including making of necessary opening ,fixing and making good the disturbed surfaces etc complete with and inclusive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specified and as directed.
Supply and fixing Energy efficient LED tube light fitting with tube 5 watts or nearest size, 240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
Supply and fixing Energy efficient LED tube light fitting with tube 10 watts or nearest size ,240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
Supply and fixing Energy efficient LED tube light fitting with tube 20 watts or nearest size ,240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
Supply and fixing LED Security light fitting with tube 30W New generation Energy saving &environmental friendly long life made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre wired with 1.0 Sq mm copper conductor cable up to connector including 1.5 m long GI Tubing light grade of 32mm dia bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc complete all as specified and as directed.
Material and labour for sub main wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 4x10sqmm for phase and neutral duly colour coded and 1x10 sqmm for earth continuity conductor green in colour complete all as specified and as directed.(Bus bar trunk/MCCB to VTPN DB of each floor)
Material and labour for sub main wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 4x6sqmm for phase and neutral duly colour coded and 1x6 sqmm for earth continuity conductor green in colour complete all as specified and as directed.(VTPN DB to Energy metre and to Each DUs)
Material and labour for sub main wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2x6sqmm for phase and neutral duly colour coded and 1x6 sqmm for earth continuity conductor green in colour complete all as specified and as directed.(for metal clad socket in each DUs)
Material and labour for sub main wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2x2.5sqmm for phase and neutral duly colour coded and 1x2.5 sqmm for earth continuity conductor green in colour complete all as specified and as directed.( parking, stair case and common area lighting DB of each floor)
Supply and fixing concealed in wall Vertical MCCB DB double door type, TPN 4 way 415V, 50Hz , IP 43 protection with 200A rated bus bar , including provision for fixing MCCB FP 100 amp as incommer and outgoing circuits MCB SP/TP complete, fill empty way with blanking plates complete all as specified and directed.
Supply and fixing concealed in wall MCB DB double door type, TPN 4 way 415V, 50Hz , IP 43 protection with 200A rated bus bar, fill empty way with blanking plates complete all as specified and directed.
Supply and fixing concealed in wall MCB DB. double door type, Single pole and neutral 08 way sheet steel phospetised powder painted with 200 amps rated bus bar 240 Volts neutral link, IP : 43 protection, complete all as specified and directed.
Supply and fixing concealed in wall MCB DB. double door type, Single pole and neutral 04 way sheet steel phospetised powder painted with 200 amps rated bus bar 240 Volts neutral link, IP : 43 protection, complete all as specified and directed.
Supply and fixing three phase electronic Energy meter tamper proof with LED display, 415 volt , 50Hz AC supply, 09 to 30 amps capacity complete all as specified and as directed.
Supply and fixing prefabricated meter box made out of 2mm thick CRCA sheet duly powder coated of approx size 50cm x 60 cm to accommodate 4 Nos three phase energy meter , front portion of the meter box to be provided with four opening to take the reading of energy meter and the four slit is to be covered/fixed with glass, necessary sunmica sheet of suitable size to be provided inside the meter box to fix the energy meter, with locking arrangements complete all as directed and as specified. Note: Energy meter shall be measured and paid separately.
M&L for earthing complete with copper plate electrode 60cm X 60cm X 3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper strip of 20mm x 3mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe light grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected up to DBs, and suitable CI top cover with handle, funnel, strainer, charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC work complete all as specified and directed.
Supply and fixing Earth continuity copper conductor of size 20mm x 3mm as earthing lead fixed to wall with and inclusive of GI pipes 25 mm dia light grade for protection of earth strips or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation
EXTERNAL WATER SUPPLY
Construction of Valve Chamber of size 750 X 750 X 750 mm comprising of 50mm thick PCC 1:5:10 type E2 foundation, 200 mm thick brick wall in CM 1:6, 15 mm thick plastering in CM 1:4 internally and externally up to 50mm below GL, 100 mm thick PCC 1:3:6 type B1 as in copings, 3mm thick MS sheet cover with suitable hinges and locking arrangements, painting steel surfaces with two coats of synthetic enamel paint over a coat of primer including necessary earth work and excavation in any type of soil complete all as specified and as directed.
Supply and install testing and commissioning of mono block pump set with minimum ratings as 10 HP, 70 Mtr Head, 5.1 LPS with delivery size of 80mm bore, 4 pole, 415 Volts, 50 Hz, AC 3 phase supply, electric driven, inclusive of air valve at delivery, pressure gauge along with cabling by XLPE copper cables from starter to pump set with cable tray and PCC foundation complete all as specified and as directed.
Cutting existing steel tubing for alterations or additions necessarily done in position without taking down and inserting T of 80 x 80 x 80 mm and Tee of 80 x 80 x 80 mm for tapping complete all as specified and as directed.
Material and labour LT panel board made out of CRCA sheet 2mm thick Indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, danger notice plate, strickering of switcher gear about termination of switch gear, and the nuts/bolts etc used are to be made of rust proof material including as per IS : 8623 aluminium bus bar with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 800 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following :(Pump House Panel) INCOMING : LT 440 Volts 3 phase, 4 wire 50 cycles, 25kA, adjustable type MCCB of 125 Amp rated 4 pole complete as per IEC: 60947-II, electronics microprocessor release, Ics=100% Icu adjustable over load setting, adjustable ground fault setting Ig=0.2-1xin, adjustable short circuit current setting Isd=1.5-10xlr complete Make: Indoasian/Schnieder/Siemens-01No.
OUTGOING (a) LT 440 Volts 3 phase, 4 wire 50 cycles, 16kA, adjustable type MCCB of 63 Amp rated 4 pole complete as per IEC: 60947-II, electronics microprocessor release, Ics=100% Icu adjustable over load setting, adjustable ground fault setting Ig=0.2-1xin, adjustable short circuit current setting Isd=1.5-10xlr complete Make: Indoasian/Schnieder/Siemens-02No. (b) Supply and fixing MCB C-curve, 32 Amp TPN, 50 Hz, 240/415 Volts complete all as directed. Make: Indoasian/Schnieder/ (For utility services) 02 Nos (c) Supply and fixing DOL starter with D range contractor & LR1D OLD for 3 phase pump set up to capacity 10 HP complete all including connection and testing -01 No. (d) LED indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B phases-01 set of 03. (e) Multifunctional Intelligent panel meter digital type for measuring volts, current, Hz, pf, power, energy, THD along with connected CTs Make: Schinder / L&T -01 No.
FIRE ALARAM SYSTEM
Supply and fix 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554 with metallic conduit and conduit accessories to wall/roof/false ceiling/ floors with necessary clamps/saddles all as specified and directed.
FIRE FIGHTING SYSTEM
Supply and fix CI foot valve conforming to IS 4038 complete of size 150mm dia complete all as specified
ARBORICULTURE
Supply, plantation and developing of Korean Carpet Grass by piece turfing including necessary earthwork excavation to a depth of 30cm in any type of soil, removing the roots and vegetation and filling of good earth, cow dung and watering etc. and applying soil pesticide, transplanting of Grass, planting, routing etc. including cost of manuring the soil, pesticides, grass, manure etc. complete all as specified.
Supply and planting of Ashoka plant including preparation of ground up to 30 cm deep and filling soft soil, Cow dung and watering etc complete all as directed by Engineer-in-Charge.
Supply and planting of Royal palm tree including preparation of ground up to 30 cm deep and filling soft soil, Cow dung and watering etc complete all as directed by Engineer-in-Charge.
Supply and planting of Gulmohar [ Hybrid] plant including preparation of ground up to 30 cm deep and filling soft soil, Cow dung and watering etc complete all as directed by Engineer-in-Charge.
Supply and planting of crotons and hedges (height 30cm C/C) including preparation of ground to required depth and filling of good earth including watering etc complete all as specified and as directed by Engineer-in-charge
Supply and planting of Bougan Vilea tree including preparation of ground up to 30 cm deep and filling soft soil, Cow dung and watering etc complete all as directed by Engineer-in-Charge. Note for Item Nos. :- [i] Supply only red soil with manure & vermi compost [As per the area of pit ] shall be measured and paid separately. However, labour element for filling and watering shall be included in the rate quoted.
Supply only approved loose soil best quality for plantation complete all as directed.
Supply only approved Vermi post compost of best quality for plantation weighing each bag of 50 KG complete all as directed.
AVIATION LIGHT
Supply & Fix aviation obstruction light LED type filament-lead bulb with 10 watt bulb complete including standard fixing arrangements complete all as specified and as directed Make: Bajaj Cat No BGAB302 LED or Equivalent in other makes
Supply & fix copper cable PVC insulated FRLS, 2.5 sqmm 3 core multi stranded conductor, fixed to wall/roof etc with suitable clamps spacers bolts nuts including PVC conduit 25mm etc. complete all as specified and as directed.
Supply & fix time switches 250v single phase of 0 to 30 Amp rating with contactor fitted inside steel enclosure complete all as specified.
EXTERNAL ELECTRIFICATION
Supply Installation and testing of copper wound step down Transformer, outdoor type complete with standard fittings 3 Ph 200 KVA outdoor type 11/0.433KV OCT(+7.5% to -7.5% @ 2.5) Dyn 11 Natural Ester Oil cooled Level 3 transformer Tem rise, Impedance and losses shall be confirm to IS 2026,IS 1180 and equivalent ICE 62270 Radiators shall be hot dip galvanized (HDG) to avoid corrosion. HV cable Box and LV cable Box as per Specification. (a) Lifting lugs/hooks for transformer and tank (b) Earthing terminal rating and diagram plate. (c) Air release device. (d) Oil filling inlet pipe with plug (e) Drain outlet pipe with brass gate valve with dummy plug (f) Conservator with level gauge (g) Silica gel breather (h) First oil fill up to the recommended level by manufacturer with new oil conforming to IS 335 (j) Type of connection : Delta/Star (k) Type of cooling : ONAN (l) Vector Group : DYN 11 (m) Type of connecting arrangement : Cable termination boxes on both HT and LT side (n) Temperature rise over an ambient of 50 degree centigrade maximum (o) All necessary arrangements with devices for measuring the temperatures of core, winding and oil. (p) In addition to the above all standard fittings shall be provided as per IS norms
Supply install and testing of outdoor type HT 11 KV, 3 phase 50 Hz totally enclosed metal clad switchgear complete with Load break switch having breaking capacity 26.3 Ka, ammeter, voltmeter and of rating up to 630 Amp complete all as specified and as directed.
Material and labour LT FPB made out of CRCA sheet 3.15 mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switcher gear about termination of switch gear and the nuts/ bolts etc used are to be made of rust proof material including as per IS 8623 tinned copper bus bar with insulators suitable for three phase and neutral, four wire LT AC, 50 Hz 415 V 500 Amp capacity complete with powder coating necessary internal connection as required and provision of the following:
INCOMING: (a) MCCB AC 3 phase 415 Volts, 50 Hz 4 pole 400 Amp capacity 36kA with adjustable type micro processing released display type relays-01 No (incoming) OUTGOING: (a) MCCB AC 3 Phase 415 volts, 50 Hz 4 pole 100 Amp capacity 25kA with adjustable micro processing released display type relays-03 No (APFC, DG AMF panel & spare) (b) MCCB AC 3 Phase 415 volts, 50 Hz 4 pole 250 Amp capacity 36kA with adjustable micro processing released display type relays-02 no (for Building load & spare) (c) Intelligent panel meter to measure voltage, current, frequency, power factor, kWH etc with all connected CT's of each breakers. (d) LED indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases for each breakers.
Supply fix and testing of LT panel board (Distribution Panel) made out of CRCA sheet 3.15 mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected and raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchgear and nuts/bolts etc used are to be made of rust proof material including as per IS:8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 Volts, 250 Amp capacity complete with powder coating necessary internal electric connection as required and provision of the following: (DG Panel) INCOMING: (a) MCCB AC 3 Phase 415 Volt, 50 Hz 4 pole 125 Amp capacity 35 kA with adjustable micro processing released display type relays-01 No.
OUTGOING: (a) MCCB AC 3 Phase 415 Volt, 50 Hz 4 pole 125 Amp capacity 35 kA with adjustable micro processing released display type relays-01 No. (b) MCCB AC 3 Phase 415 Volt, 50 Hz 4 pole 63 Amp capacity 25 kA with adjustable micro processing released display type relays-02 No (for Lifts & 01 Spare) (c) Street light timer switch 415 Volt, single phase of max 20 Amp rated with power contactor. (d) Intelligent panel meter to measure voltage, current, frequency, power factor etc with all connected CTs (e) LED indicating Lamps for each phase with colour code Red Yellow Blue for R,Y and B Phases
Supply and fix and testing bus bar trunking system for the complete building power supply duly insulated three phase of rating 250 Amps, 25 KA 415 Volts aluminium conductor galvanised GI enclosure 0.8 mm thick (non painted) and lightening bus trunking with galvanised steel enclosure (0.45 mm thick), non painted through service shaft including end feed unit with MCCB 250 AMp, 25 KA 4 pole with rotary handle, termination links of building comprising of the following all as specified and as directed
Supply and fix straight length with plug in outlet
Supply and fix Flange End
Supply and fix Horizontal elbow
Supply and fix Vertical elbow
Supply and fix End Cap
Supply and fix Brackets
Supply and fix Springs support
Supply and fix Fire Barrier
Supply and fix external GI earth strip 32 x 6 mm
Supply and fix End feed unit with MCCB
Supply and fix 250 Amp, 25 kA, 4 pole MCCB
Supply and fix terminal links as required
Supply and fix 63 Amp Thermoplastic plug in tap-off box with 8 module MCB
Supply and fix MCB 63Amp 4 pole 10 kA-10 nos
Supply and fix 63 Amp 4 pole lightening trunking
Supply and fix feed unit with end cover
supply and fix flexible joint
Supply and fix Bracket support with steel cable
Material and labour for masonry platform for transformer of size 1.5 m x 1.5 m x 1.2 mm height above ground level and 0.60 m below ground level PCC blocks in CM 1:6 including excavation and earth work in any type of soil foundation in PCC 1:2:4 type B1 with 20mm graded aggregate 10 cm thick at top of the platform over 75 mm thick PCC (1:4:8) sub base over approved earth filling and plastering 20mm thick in CM (1:4) on PCC blocks walls and applying three coats of white wash etc complete all as specified and as directed by Engineer-in-charge.
Supply and fix compact type timer panel of capacity 6 KW including of power contactor of 32 Amps Tp, MCB 40 Amp TP and Digital Timer Switch 415 Volts, steel enclosure complete all as specified. Make: Havells Cat No IHXTS03060 or Equivalent of other makes
DG SET
Silent Engine generating set with acoustic enclosure as per CPCB norms 415 volts 62.5 kVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including acoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613/ 5000 with and including the following : (i) The capacity of generator set shall be net after all due de-rating factors as per relevant ISI design. (ii) Rate quoted shall be deemed to be inclusive of cable and terminations from generator to the AMF panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed.
(A) Alternator: Standard design alternator rated at 62.5 kVA net output at site after considering de-rating as per site condition at 08 (lag) power factor AC, 3-phase 4-wire 415 volts 50 HZ, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS-2613/5000/IS-4722 (i) Insulation class - 'H' (ii) Temperature rise Class- 'H' (iii) Excitation : Self Excited. (iv) Regulation performance: The voltage is kept constant with +/- 1% , manual voltage adjustment within +/- 5%. (v) Frequency regulation +/- 1%.
(B) Diesel Engine: Adequate capacity of diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS- 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories shall be as under (i) Fly wheel with housing. (ii) Cooling system : Moulded radiator with fan & belts. (iii) Cooling water pump : Centrifugal type belt driven. (iv) Exhaust system : Exhaust system complete with MS pipe of suitable size light grade up to & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold silencer: Residual type Beloows
v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. vi) Lub oil System :Lubricating oil filter ,Lubricating oil pump vii) Air Intake System :Air intake Manifold, Air cleaner dry type viii) Governor :- Electronic Governor ix) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator x) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel
xi) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display. xii) Safety Controls : - Engine low lube oil pressure high water temperature and over speeding of engine xiii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling xiv) Accessories :- AVM Pads built or separately mounted to manufacturer base frames. xv) Base Frame : - Made out of ISMC 250 of sturdy design made of MS channel with necessary reinforcement and predetermined holes as per OEM norms. xvi) Fuel Tank :- Fuel tank of capacity to suit Daily 12 hours. Daily service fuel tank made out of 2mm thick (14G) HR sheet top and bottom with calibrated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base inside the acoustic enclosure xvii) MS pipe line to and from the fuel tank to the DG Set
C) AMF Panel :- Factory made indoor type control cubical made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front and rear opening of 415 volts 3 -phase 4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 62.5 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage etc.
D) Acoustic Enclosure:- Manufactured by OEM suitable for 62.5 KVA DG Set (i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board (iii) The generating set batteries and control panel should be inside the enclosure. (iv) Fuel tank should be inside of the enclosure (v) Construction Details/specification are as follows: a) Outer body :- CRCA Sheet of 2mm thick b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- AS per OEM Norms vi) The acoustic should be composite in construction and fully assembled integral unit vii) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated plat form viii)The fuel tank to be located inside enclosure. ix) The DG Set should be provided with external Emergency stop push button
x) The enclosure should be suitably illuminated by LED Lamp fittings. xi) The noise level should be 75 dba at 1m under free field conditions. xii) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade
E) The coated rate includes excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 (1:2:4) using 40 mm graded aggregate of size not less than 4.6 x 2. 4 x 0.8 m for placing of DG Set and for erection of steel tubular poles to form shed over DG set of complete all as specified and directed.
a) Fire man switch b) Automatic rescue device (A.R.D) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load. c) Battery operated emergency light (LED ceiling fitting ), alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery. d) Four sleek circular LED light fitting 5W-4 Nos in and includes false ceiling. e) One sleek circular PVC heavy duty fan 300 mm sweep in false ceiling. Make for (c) and (d) : Philips/ Bajaj / Havells / Crompton Greaves. f) Aluminium chequered plate (3mm thick) as flooring joint in chequered plate should not more than one and top covering with Granite flooring complete. g) Non stop button /independent operation. h) Over load warning indicator both audio and visual type with tripping system having relays etc (overload protection/tripping system). j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds.
k) Car size shall be in confirmity with IS -3534-1976 and body to be stainless steel of 16 gauge SS moon rock finish with stainless steel hand rail 38mm hairline finish. l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS m) Mirror of 4mm thickness of suitable size as specified. n) Opening with mirror of 5mm thick 200X800mm size in all the doors (Car/Landing doors). o) Specification plate with complete details. p) Continuous earthing for machine and equipments. s) Full length display indicator panel. t) Main drives and control shall be of latest , high effective and low power consumption. u) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. v) Stainless steel front opened landing door with small opening for vision of size 200mm x 800mm with toughened glass not less than 8mm thick. w) Intercom be connected with nearest security post
a) Fire man switch b) Automatic rescue device (A.R.D) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load. c) Battery operated emergency light (LED ceiling fitting ), alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery. d) Four sleek circular LED light fitting 5W-4 Nos in and includes false ceiling. e) One sleek circular PVC heavy duty fan 300 mm sweep in false ceiling. Make for (c) and (d) : Philips/ Bajaj / Havells / Crompton Greaves. f) Aluminium chequered plate (3mm thick) as flooring joint in chequered plate should not more than one and top covering with Granite flooring complete. g) Non stop button /independent operation.
h) Over load warning indicator both audio and visual type with tripping system having relays etc (overload protection/tripping system). j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. k) Car size shall be in conformity with IS -3534-1976 and body to be stainless steel of 16 gauge SS moon rock finish with stainless steel hand rail 38mm hairline finish. l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS m) Mirror of 4mm thickness of suitable size as specified. n) Opening with mirror of 5mm thick 200X800mm size in all the doors (Car/Landing doors). o) Specification plate with complete details. p) Continuous earthing for machine and equipments. s) Full length display indicator panel. t) Main drives and control shall be of latest , high effective and low power consumption.
u) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. v) Stainless steel front opened landing door with small opening for vision of size 200mm x 800mm with toughened glass not less than 8mm thick. w) Intercom be connected with nearest security post
PHASE – II: SCHEDULE "A" PART – XVIII: MAINTENANCE OF ARBORICULTURE WORKS DURING DEFECT LIABILITY PERIOD OF WORK UNDER PHASE – I Maintenance of Arboriculture as provided under Serial Item No. 65 to 70 of BoQ by weeding, hosing, saucer melding once in every 15 days, planting new plants / grass in place of dead plants / grass of same species and height with out any extra cost to the department and as directed complete for the period of maintenance period of 12 Months complete all as specified and as directed. Note: Rate quoted shall be deemed to include for all labour, materials, tools & plants and regular watering, using sprinklers, including supply and spreading / spraying organic manure, chemical fertilisers, pesticides to the required extent complete all as specified.
Phase-III : Schedule 'A' Part -XIX COMPREHENSIVE MAINTENANCE: Comprehensive maintenance of electrically operated passengers lift of capacity 08 passengers lift of capacity 544 Kgs for G+9 floors building) all as mentioned vide Serial Item No. 120 of BOQ complete all specified in PS and as directed for First Year after expiry of Defects Liability Period. Note: [a] Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of gear oil/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the Tenderer includes for the above lifts. [b] Preventive maintenance consists of carrying out routine check by skilled personnel as specified in particular specifications and as recommended by Engineer-in-charge and lubrication to all moving parts ,topping parts, topping up of oils as per lubrication chart including Material and Labour for all consumable and major/minor spare parts.
Comprehensive maintenance of electrically operated passengers lift of capacity 13 passengers lift of capacity 884 Kgs for G+9 floors building) all as mentioned vide Serial Item No. 123 of BOQ complete all specified in PS and as directed for First Year after expiry of Defects Liability Period. Note: [a] Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of gear oil/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the Tenderer includes for the above lifts. [b] Preventive maintenance consists of carrying out routine check by skilled personnel as specified in particular specifications and as recommended by Engineer-in-charge and lubrication to all moving parts ,topping parts, topping up of oils as per lubrication chart including Material and Labour for all consumable and major/minor spare parts [c] Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labor for all minor & major spare parts and consumables of the lift that may occur during the operation.
PHASE –IV: SCHEDULE "A" PART – XX: SECOND YEAR COMPREHENSIVE MAINTENANCE OF 08 PASSENGERS LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No.120 to 122 OF THIS BOQ for Second Year after expiry of Defects Liability Period. All as per Serial Item No. 128 & 129 above but for Second Year after expiry of Defects Liability Period
SECOND YEAR COMPREHENSIVE MAINTENANCE OF 13 PASSENGERS LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM 123 to 126 OF THIS BOQ for Second Year after expiry of Defects Liability Period. All as per Serial Item No. 130 & 131 above but for Second Year after expiry of Defects Liability Period
PHASE –V: SCHEDULE "A" PART – XXI: THIRD YEAR COMPREHENSIVE MAINTENANCE OF 08 PASSENGERS LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 120 to 122 OF THIS BOQ for Third year after expiry of Defects Liability Period All as per Item No. 132 above but for Third Year after expiry of Defects Liability Period.
THIRD YEAR COMPREHENSIVE MAINTENANCE OF 13 PASSENGERS LIFT AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 123 to 126 OF THIS BOQ / SCHEDULE "A" PART – XVIII: All as per Serial Item No. 133 above but for Third Year after expiry of Defects Liability Period.
Komal Buildcon Pvt. Ltd.
Venkateswara Electricals
GOPAL TEKNOCON PRIVATE LIMITED
SOOD ASSOCIATES PVT LTD
SVS PROJECTS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid