Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6 LAccepted-AOC PLOT NO 15 KALAYAN NAGAR ROAD NO 3 GALI NO 5 JAIPUR | JAIPUR | JAIPUR | RAJASTHAN | L1 | Accepted-AOC As Per Rate Approval Letter | |
| 2 | L2₹6 L+₹36,234.60 (23.5%)Accepted-AOC 2 G F AGARWAL TOWER SHOBHATO KI DHANI JODHPUR | JODHPUR | JODHPUR | RAJASTHAN | L2 | Accepted-AOC As Per Rate Approval Letter | |
| 3 | L3₹6 L+₹82,620.16 (53.5%)Accepted-AOC 142 F 1 MOON RESIDENCY 2 ASHOK NAGAR NIWARU ROAD JAIPUR 302012 | JAIPUR | JAIPUR | RAJASTHAN | 302012 | L3 | Accepted-AOC As Per Rate Approval Letter |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
13 Aug 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintendent
Superintendent MDM Hospital Shastri Nagar Jodhpur
Supply of Gastroenterlogy Item 02 for One Year
2020_SNMCJ_191447_1
E tender No 03 Ref No 9246 Dated 20-07-20 Item 02
Open Tender
Consumables (Hospital / Lab)
Item Wise
365 days
Items
Please refer Tender documents.
2 documents required · 2 mandatory
₹400
Yes
Superintendent MDM Hospital Jodhpur
₹30,000
Yes
MDM Hospital Shastri Nagar Jodhpur
21 Sept 2020
21 Jul 2020
14 Aug 2020
22 Jul 2020
13 Aug 2020
22 Jul 2020
27 Jul 2020
90 days
Gastroenterlogy
Multi band ligator barrel for endoscopic variceal ligation A set of 6 bands Compatible with videogastroscope having 9-10 mm outer diameter.
Double pig tail Biliary Stents (Plastic) 10 fr X 10 cm Stents should be radio-opaque and should be made of a pliable material that is soft on tissue and strong on results. Should be compatible 0.025-0..35 inch guide wire.
Double pig tail Biliary Stents (Plastic) 10 fr X 8 cm Stents should be radio-opaque and should be made of a pliable material that is soft on tissue and strong on results. Should be compatible 0.025-0..35 inch guide wire.
Double pig tail Biliary Stents (Plastic) 8 fr x 10 cm Stents should be radio-opaque and should be made of a pliable material that is soft on tissue and strong on results. Should be compatible 0.025-0..35 inch guide wire.
Straight plastic Stent (Biliary) 10 fr X 8 cm Stents should be radio-opaque and should be made of a pliable material that is soft on tissue and strong on results. Should be compatible 0.025-0.035 inch guide wire.
Straight plastic Stent (Biliary) 10 fr X 10 cm Stents should be radio-opaque and should be made of a pliable material that is soft on tissue and strong on results. Should be compatible 0.025-0.035 inch guide wire.
Straight plastic Stent (Biliary) 8.5 fr x 10 cm Stents should be radio-opaque and should be made of a pliable material that is soft on tissue and strong on results. Should be compatible 0.025-0.035 inch guide wire.
Metal Stent (Biliary) a. Expanded stent diameter 10mm b. Uncovered c. Stent length 6cm, 8cm and 10 cm d. Stent introducer diameter should be 8 Fr or less. e. Should be compatible with instrument channel size of 4.2 mm and a guidewire of 0.025-0.035 inch. f. Wire mesh of the stent should be made of Nitinol/Elgiloy. g. Should be clearly visible on Flouroscopy with proximal and distal markers being easily distinguishable.
Self Expandalbe Metal stent (Esophageal) a. Length – 10cm, 12 cm , 15cm b. Should be suture released. c. Partially covered. d. Stent introducer system should be 16 Fr or less. e. Should be compatible with 0.035 inch diameter guidewire or more f. Wire mesh of stent should be made of nitinol g. Should be clearly visible on Flouroscopy with proximal and distal post deployement markers being easily distinguishable. h. Stent body diameter 18-20mm
Hydrophilic Guidewire 260cm (Terumo) a. Tip requirement – straight tip b. Diameter – 0.025 inch c. Length – 260 cm d. Hydrophilic in nature
Hydrophilic Guidewire 260cm (Terumo) a. Tip requirement – J tip and straight tip both b. Diameter – 0.032 inch c. Length – 260 cm d. Hydrophilic in nature
Rat tooth Foreign Body forcep Steel tip and spiral metal mesh body
Exchange Guidewire a. Length – 450 cm b. Hydrophilic tip c. Diameter- 0.025 inch having strength equivalent to 0.035 inch guideware available in the market
Mechanical Lithotripsy basket a. Should be compatible with the existing Olympus handle in the department. b. Should have rotatable basket c. Wire guided version d. Compatible with working channel of 4.2 mm and a basket size of 30 mm
Pancreatic stent (Plastic Straight) 5 Fr X 12cm Stents should be radio- opaque and should be made of a pliable material that is soft on tissue and strong on results. Should be compatible 0.025-0.035 inch guide wire.
Pancreatic stent (Plastic Straight) 5 Fr X 10 cm Stents should be radio- opaque and should be made of a pliable material that is soft on tissue and strong on results. Should be compatible 0.025-0.035 inch guide wire.
Pancreatic stent (Plastic Straight) 7 Fr X 12 cm Stents should be radio- opaque and should be made of a pliable material that is soft on tissue and strong on results. Should be compatible 0.025-0.035 inch guide wire.
Pancreatic stent (Plastic Straight) 7 Fr X 10 cm Stents should be radio- opaque and should be made of a pliable material that is soft on tissue and strong on results. Should be compatible 0.025-0.035 inch guide wire.
Steel guide wire with spring tip Compatible with Savary Gillard dilators used for Esophageal Stricture Dilatation
Roth Basket for Foreign body removal Compatible with a biopsy channel of 2.8 mm
Dormia basket for foreign body removal from esophagus and stomach Compatible with a biopsy channel of 2.8 mm
Magnet for Endoscopic metallic Foreign body extraction Compatible with a biopsy channel of 2.8 mm
Cystotome for Transgastric or transduodenal puncture of pseudocyst 10 Fr Outer catheter diameter 10 Fr length 165 cm Diathermy ring size compatible with the mentioned cystotome alongside.
Cystotome for Transgastric or transduodenal puncture of pseudocyst 6 Fr Diathermy ring size compatible with the mentioned cystotome alongside.
Metal Stent (Colonic) a. Expanded diameter 25 mm and Flange 30 mm b. Stent length 6, 8 and 10 cm c. Stent introducer should be 10 fr or less. d. Should be compatible with instrument channel size of 3.7 mm e. Wire mesh of the stent should be made of Nitinol. f. Should be clearly visible on fluroscopy with proximal and distal markers being easily distunguishable. g. Re-Constrainability upto 70 percant
Biliary ballon dilation a. Should have RO water for accurate postioning. b. Ballon length 2-4mm c. Inflated ballon OD 4, 6, and 8 mm d. Should be compatible with instrument channel size of 4.2mm
CRE Balloon – a. Size 12mm – 15mm, 15mm – 18mm b. Should be compatible with instrument channel size of 4.2mm c. Should have radio – opaque markers for accurate positioning
Triple Lumen Sphinctorotome – a. Compatible with 0.035 inch exchange guidewire b. Cutting wire length of 20mm & 30mm c. Nose length of 5mm
Needle Knife Pappilotome – a. Tapered tip for smooth insertion b. Tip & sheath should be made of highly radio-opaque material c. Precurved tip for easy position d. Should be double lumen wire-guided e. Compatible with 0.035 inch guide wire f. Needle length 5mm
Sohendra Biliary Dilator Sets – 7, 8.5, & 10 Fr. Biliary dilator with radio-opaque markers.
Reusable Biopsy Forceps – for upper & lower GI endoscopy.
RENIX
PMS Medical System
LIBRAA SCIENTIFIC
PMS Medical System
stage.html
html • 0.05 MB
technical_339539.pdf
PDF • 0.25 MB
techsummary_339539.pdf
PDF • 3.01 MB
finance_339539.pdf
PDF • 1.63 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_339539.pdf
PDF • 1.63 MB
GastroenterologyWorkOrder.pdf
PDF • 1.41 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .