| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹11.3 LAccepted-AOC 82 10 POST OFFICE ROAD MANDI DISTT MANDI H P | L-1 | Accepted-AOC quoted rates are lowest | |
| 2 | L-2₹11.5 L+₹22,165 (1.96%)Rejected-Finance HIMACHAL PRADESH HP | L-2 | Rejected-Finance Quoted rates are below | |
| 3 | L-3₹12.1 L+₹78,250 (6.91%)Rejected-Finance | L-3 | Rejected-Finance Quoted rates are below |
Tender Value
₹13.9 L
EMD Value
₹27,795
Closing Date
20 Mar 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Superintending Engineer IIT Mandi HP
Providing and fixing Power points, AC points and 3 phase points in SBB labs at A1 and A6 top floors at South Campus of IIT Mandi.
2023_IITMD_744933_1
IITMandi (CW)/SE-1360/2022-23/8323-25 dt.14-03-23
Open Tender
Electrical Works
Item Rate
45 days
South Campus of IIT Mandi
please refer to NIT
2 documents required · 2 mandatory
₹1,180
The Registrar IIT Mandi
₹27,795
18 May 2023
14 Mar 2023
21 Mar 2023
14 Mar 2023
20 Mar 2023
14 Mar 2023
14 Mar 2023 - 17 Mar 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit/ PVC Casing Caping , with modular switch, modular plate, suitable PVC box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. Group A as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Wiring for circuit/ submain wiring alongwith earth wire with the2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and drawing 3 X 4 sq. mm wire of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ PVC Casing as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and drawing 6 X 4 sq. mm wire of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ PVC Casing as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and drawing 9 X 4 sq. mm wire of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ PVC Casing as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and drawing 5 X 4 sq. mm wire of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ PVC Casing as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and drawing 3 X 6 sq. mm wire of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/ PVC Casing as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing of 32 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 5/6 amp switch modular on the existing modular plate & switch box including connections but excluding modular plate etc. as required of make: Havells Crabtree Athena, North west, L&T as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 3 pin 5/6 amp socket outlet modular on the existing modular plate & switch box including connections but excluding modular plate etc. as required of make: Havells Crabtree Athena, North west, L&T as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 15/16 amp switch modular on the existing modular plate & switch box including connections but excluding modular plate etc. as required of make: Havells Crabtree Athena, North west, L&T as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 6 pin 15/16 amp socket outlet modular on the existing modular plate & switch box including connections but excluding modular plate etc. as required of make: Havells Crabtree Athena, North west, L&T as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of Single pole, in the existing MCB DB complete with connections, testing and commissioning etc. as required of make: Havells , Legrand, L&T as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of Triple pole, in the existing MCB DB complete with connections, testing and commissioning etc. as required of make: Havells , Legrand, L&T as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing of 8 way (4 + 24), Double door ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Supplying and fixing of 12 way (4 + 36), Double door ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Providing and fixing 125 Amp FP MCCB 36 KA rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required as per entire satisfaction and direction of engineer–in–charge.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required as per entire satisfaction and direction of engineer–in–charge.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of Upto 35 sq. mm (clamped with 1mm thick saddle) on wall surface as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying 4 core 16 Sq. mm XLPE insulated unarmoured copper cable as per IS7098 (Part 1) 1988 as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying of Square Recessed Down Lighter (Fixture size: (LxWxH) in (595x595x65) mm ) of Wattage 36 W (6500K) with electronic driver etc. as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying of 20W surface and wall mounted LED batten (1200 mm) with minimum colour temperature of 6000 k , P.F > 0.9 etc. as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 3 Module, PVC box alongwith modular base & cover plate for modular switches in recess etc as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 12 Module, PVC box alongwith modular base & cover plate for modular switches in recess etc as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing of Heavy duty 32 mm PVC casing caping double lock along with accessories in surface as required of make: Diplast, Poly Champ, Polyfit as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and making end termination with brass compression gland and copper lugs for 4 X 16 sq. mm (28mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Kalap Engineers and Builders
M/S BANSAL ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .