Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC | L1 | Accepted-AOC negotiated rated are within the justified cost |
Tender Value
₹2.1 L
EMD Value
₹4,287
Closing Date
27 Oct 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
O/o Superintending Engineer IIT Mandi HP-175075
Re- tender for Providing additional power points, in A11 Electronics Lab North Campus of IIT Mandi
2021_IITMD_648019_3
IITMandi (CW)/SE-1183/2021-22/2760-62 dt 13-09-21
Open Tender
Electrical Works
Item Rate
20 days
North campus of IIT Mandi
please refer to NIT
2 documents required · 2 mandatory
₹1,180
The Registrar IIT Mandi
₹4,287
26 Nov 2021
18 Oct 2021
28 Oct 2021
18 Oct 2021
27 Oct 2021
18 Oct 2021
18 Oct 2021 - 25 Oct 2021
75 days
Amount
Supplying and drawing 3x4 sq mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing of 25 sq mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 5/6 A switch modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 15/16 A switch modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 3 pin 5/6 A socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 6 pin 15/16 A socket outlet modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 3 Module Modular base & cover plate on existing modular metal boxes etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing of 12 way (8 + 36), Double door, Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing single pole 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of Single pole, in the existing MCB DB complete with connections, testing and commissioning etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 63 A rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 63 A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and making end termination with brass compression gland and aluminium lugs for 4 X 10 sq. mm (25mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 3 Modue PVC box to be fixed in open surface/Wall as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing 3 Modue PVC box to be fixed in the existing Wall Trunking as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
Supplying and fixing of 25 mm size of medium class PVC Casing-Capping along with accessories in surface as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .