Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC VPO BARI TEHSIL FATEHPUR DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.0 L+₹1.3 L (11.5%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹13.3 L+₹1.6 L (13.9%)Rejected-Finance NOT SPECIFIED | L3 | Rejected-Finance L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical A CLASS GOVT ELECTRICAL CONTRACTOR VPO CHOBIN TEHSIL BAIJNATH DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical CHIEF ENGINEER OP KANGRA ZONE HPSEBL DHARAMSHALA | KANGRA | HIMACHAL PRADESH | 175013 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹11.1 L
EMD Value
₹27,749
Closing Date
18 May 2021, 5:00 pmClosed
Er. Rumel Singh, Superintending Engineer
Superintending Engineer, OP Circle, HPSEBL, Dalhousie Distt. Chamba HP
Tender for Supply of equipment material , design, erection, testing commissioning for SOP to LIS Phalian, Rajol, Upper Anuhi and Salan by providing 11-0.4KV, 250 KVA Sstn. alongwith 11 Kv HT line in ESD Kotla ED jawali Bid No OCD/DB/Bid-II/2021-22
2021_HPSEB_47041_1
OCD/DB/Bid-II/2021-22
Open Tender
Electrical Works
Turn-key
180 days
Phalian, Rajol, Upper Anuhi and Salan in Kotla
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,900
Sr. Executive Engineer, ED, HPSEBL Dalhousie
₹27,749
18 Jun 2021
3 May 2021
22 May 2021
3 May 2021
18 May 2021
3 May 2021
Amount
250 KVA S/Stn
11/.4 KV 250 KVA DTR (REC Sep. ord 11/1976
Prov. ST Pole Pole 9 Mtr. Long W/L 200 Kgs
Muff for steel tubular pole with concrete filling
X-Arm: [Channel Iron (100x50x5 mm), Length : 2800 mm X 4 Nos]
X-Arm: [Channel Iron (75x40x5 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
MS Angle Iron (50X50x5 mm), Length: 2800 mm x(1 Nos for LA's + 2 No. for Dist Panel Box)
G.O.Switch complete.
D.O. Fuse(REC Spec 63/1967,ISS No 9385
Surge Arrester, 9 kV Station Class
Discs insulator sets (comp. 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) i/c Dead End Clamps etc.)
Stay set complete without stay wire (@ 6 Kg per set)
Pipe earthing with GI,Charcoal & Salt
Prov. LT distribution panel with MCCCB 400 A,36 KA,4P,1 No. and SFU 4 No. 100 A outgoing)
Half clamp
M. S. Nuts & Bolts off sizes
G.I. Thimbles
Lead Tin solder
Solder Flux
Copper Thimble
Barbed wire (REC Sp F 3/1981)
LT Cable 3-1/2 core-240 mm sq.
Alluminium Paint
Prov. AAAC 55 mm², 7/3.15 mm
Prov. Transformer Bed plinth for 250KVA S/Stn structure complete with CC 1:6:12 R.R. massonery & plastering etc. a/w Chain link fencing, Angle iron Gate etc. for DTR Fencing.
CT/PT UNIT
Prov. 11KV CT-PT unit i.e. PT (1 unit, 11KV/110V):CT (3No.10-400/500A) accuracy class 0.5S.
Prov, Energy meter (3 phase, 4 wire) HT CT type for Above
Pvc Multistrand 4 mm Sq. copper wire with 1 inch GI pipe fir concealing
X-Arm: [Channel Iron (100x50x6 mm), Length : 460 mm X 2 Nos] for supporting main channel for CT-PT unit
CT-PT Unit Belting and Knee BracingMS Angle Iron (50x50x5 mm), Length : 2800mmx 4 Nos.
CT-PT Unit Belting and Knee Bracing MS Angle Iron (35x35x5 mm), Length : 2800mmx 2 Nos.
Half clamp (MS Flat 50x6 mm)
Full clamp (MS Flat 50x6 mm)
Nut & Bolts off size
Aluminium Thimble
copper Thimble
HT Line (0.360 MM)
Prov. 9 Mtr. ST Pole Mtr. Long
Muff for steel tubular pole with concrete filling
Prov. AAAC 80 mm², 7/3.81 mm
Prov. GI Wire 8 SWG
CI X arm for Double pole structure 2400x100x50mm
AI Knee Bracing Set 2700x50x50 mm
Prov. 11 Kv G.O. Switch
Prov. HT Stay Set complete in all respect
Earthing set complete
Prov. MS NUT & Bolts Off Size
Prov. Stay Wire 7/3.15
Prov. Danger Plate (250x200x1.6 mm)
Half clamp (MS Flat 50x6 mm)
Full clamp (MS Flat 50x6 mm)
Eye Hook for earthing
Aluminium Paint
11 Kv Pin Insultor with pin
11 Kv Disc insulator set with ball cleave and dead end clamp
CIVIL WORKS
Prov. And fixing anodized aluminium work for door windows ventilator and partition with extruded built up standard tubular and other sections of approved make confirming to IS 733 & IS 1285 anodized transparent or dyed to required shade and according to IS 1868 fixed with Raw plugs and screw and side with required PVC/Neoprene belt etc.i.e. cleato angle aluminium snap beading for glazing /panelling CP brass stainless screw as per architectural drawings.
Providing and fixing glazing in aluminium door windows ventilator shutterand partition with required PVC /Neoprene gasket etc. complete 4 mm thicknessglass pans ( weight not less than 10 Kg/m sq)
Prov. And fixing 6 mm thick auminium grill should be powder coated shade as per approved design and drawing
Prov. And fixing galvanized MS wire gauge as IS gauge designation No. 140 G to doors windows and clearstory window with wire gauge 0.71 mm instead of IS gauge designated No. 85 G with wire of dia 0.56 mm as per design and drawing
Prov. And fixing partition with butt jointing and nails prelaminated board bwp phenail bounded exterior /interior grade both sides 12 mm thick
Prov. & fixing aluminium sliding door bolts with nut and screw etc complete 250x16 mm
Prov. & fixing aluminium Tower bolts with necessary screw etc complete 150x10 mm
Prov. & fixing aluminium handle with necessary screw etc complete 125mm
Prov. & fixing bright finished brass floor door stopper with rubber cushion with necessary screw etc complete 100 mm
Deepansh Electrical
SANJEEV KUMAR KALIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .