| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC SANYAL PARA ROAD HARANAVI KOLKATA 700 148 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700148 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.2 L+₹18,383.60 (2.61%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹7.7 L+₹63,020.40 (8.94%)Rejected-Finance 24A RABINDRA SARANI KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L3 | Rejected-Finance L3 | |
| 4 | L4₹7.8 L+₹76,321.50 (10.8%)Rejected-Finance 210 A RASHBEHARI AVENUE KOLKATA 700029 | KOLKATA | KOLKATA | WEST BENGAL | 700029 | L4 | Rejected-Finance L4 | |
| 5 | L5₹7.9 L+₹84,307 (12.0%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹17,950
Closing Date
18 Jul 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
Annual Maintenance Estimate of E.I. of Backward Class Welfare Department at Administrative Building, Salt lake DJ-4, Kolkata----Addition, Alteration of Electrical Installation works in different department of different floor.--- as and when required
2025_WBPWD_874608_1
WBPWD/EE/BED/e-NIQ-45/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
Backward Class Welfare Department
Please refer Tender documents.
5 documents required · 5 mandatory
₹17,950
25 Aug 2025
5 Jul 2025
21 Jul 2025
11 Jul 2025
18 Jul 2025
11 Jul 2025
Amount
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. i) Average run 6 mtr
do-do-on board 6A modular plug point
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make- Legrand/Seimens/Schneider) i) 4 way Enclosure (607715)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make- Legrand/Seimens/Schneider) ii) 2+12 way Enclosure (607712)
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. (Make- Legrand/Seimens/Schneider) ii) 160 A
Supplying and fixing 240V SP MCB of Breaking apacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make- Legrand/Seimens/Schneider) i) 6-32 A
Supplying and fixing 240/415 V TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make- Legrand/Seimens/Schneider) ii) 63 A
Supplying and fixing 240/415 V DP MCB Isolator on din rail of existing DBs and necessary connection. (Make- Legrand/Seimens/Schneider) i) 40 A
Supplying and fixing 240/415 V FP MCB Isolator on din rail of existing DBs and necessary connection. (Make- Legrand/Seimens/Schneider) i) 63 A
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the 20mm size PVC rigid conduit FR(Precision make) incl. Necy fittings as required i) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
ii)2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) ECC
iii) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) ECC
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the 20mm size PVC rigid conduit FR(Precision make) incl. Necy fittings as required i) 2x80/0.4 (10 sqmm) + 1x84/0.3 (6 sqmm) as ECC
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the 40 mm size PVC rigid conduit FR(Precision make) incl. Necy fittings as required ii)4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. i)1.5 sq mm
i) 2.5 sq mm
iii) 4 sq.mm
iv) 6 sq mm
v) 10 sq mm
vi) 16 sq mm
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. 1 x 6 A Separate Board
Supply & Fixtng of Computer board (Modular typel:- Supply & Fixing 240 V, 3 nos.6A, & 1 no.20A Modular type plug socket with separate 3 nos. 6 A & 1 no. 20A Modular type switch, indicator & 20A Modular type SP MCB 25A on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl.S&Fswitch board and cover plate and maling necy. connections with PVC Cu wire and earth continuity wire etc.(Legrand Myrius/ Crabtree/ Siemensf 3 x 6 A + 1 x 16 A Computer Board
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board as per GS. 1 x 16 A Power Socket Board
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board as per GS. 25 A, 3 pin Modular type plug socket
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 4 Module GI Modular Box for OLP Starter
Supply of OLP-3, 25 A is a highly advanced, microprocessor controlled starter used for ACs and other compressor loads. The time-tested combination of Voltcheck, Ampcheck and Timecheck ensures safe operation and long life of AC Compressors. OLP-3, 25 A Starter [Make : Electron/Ultratech/Ultrasafe]
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
Fixing only fluorescent/LED light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length.
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: For 30 cm (12") Exhaust fan
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For Al-30 cm Exhaust fan (12")
Supply of 4 Ft. Single LED Fitting with 1 no 20 Watt MASLED tubelight (CCT- 6500 K, CRI- ≥ 70%, Minimum Lumen Out of Luminaries:- 100 lm/watt) for indoor application,complete with all accessories having following Model / Cat No. [Make- Philips (TMC 502 1 x T-LED 22W with MAS LEDTube 1200mm 18W 865 T8I-21001m)/ Wipro/As per choice of EIC]
Supply of 4 Ft. Double LED Fitting & 2 nos 20 Watt MAS LED Tube light (CCT- 6500 K, CRI- ≥ 70%, Minimum Lumen Out of Luminaries:- 100 lm/watt) for indoor application, complete with all accessories having following Model / Cat No. [Philips (TMC 502 2 x T-LED 22W with MAS LEDTube 1200mm 18W 865 T8I-21001m)/ Wipro/As per choice of EIC]
Supply & installation of 18Watt (CCt-6500K, CRI- ≥ 70%, Minimum Lumen Out of Luminaries:- 100 lm/watt) LED lamp for indoor application in existing fittings interconnection by 2x .75sqmm flexible copper wire of 1.10 mt. length. as per direction of EIC, having following Model / Cat No. [Philips - Mas LEDTube 1200mm 18W 865 T8 I – 2100lm)/ Wipro/As per choice of EIC]
Supply and fixing of electronics ballast in existing light fittings as per direction of EIC. (Make Philips- Cat No- EBE 136 ,220-240 v 50 Hz/ Wipro/CG)
Supply and fixing of electronics ballast in existing light fittings as per direction of EIC. (Make Philips- Cat No- EBE 236 ,220-240 v 50 Hz/ Wipro/CG)
Supply and fixing of 240V LED driver for 18 watt LED square/round fittings. (Make-Philips/Wipro/CG)
Supply of 35/36 watt system wattage 6500 K/4000K colour Temperature, cool day light colour, recessed mounted IP 20 LED 2ft X 2ft luminaries having > 3050 lm system output. Luminary shall be made up of CRCA epoxy polyester powder coated housing. Luminaries shall have optical grade High Efficiency Translucent Optical component for very high efficiency with minimum glare.Driver output voltage shall be less than SELV limits for safe DC operation and maintenance. The Driver should be fully designed and manufacture in India. The fittings should be fixed in false ceiling by hanging with chain / spring and fastner and as required for proper fixing with the actual ceiling and complete with all accessories having following Model/Cat No.- Philips RC380B LED42S- 6500 G6 L60W60 PSU OD S1/ Wipro CRCO1ORO3OHP57G3 /As per choice of EIC]
S &D of electronics 22-42 Watt, 950 mA LED driver suitable for 36/38 watt 2ft x 2ft LED light fittings. (Philips- 441537014080 /wipro/crompton)
Supply of 17/18watt round/square shape recessed mounted LED Luminaries with Aluminium diffuser & housing (CCT- 3000K/4000 K/6500 K, CRI- ≥ 70%, Minimum Lumen Out of Luminaries ≥ 105 lm/watt) for false ceiling application, complete with all accessories having following Model/Cat No. Model/Cat No.-Philips-Duraslim/Wipro/ Crompton /As per choice of EIC]
Supply & Delivery of Exhaust fans complete with all accessories having the following Model / Cat No. (Make & Model approved by EIC) 12"(300mm) Sweep, Speed- 1420 RPM, [Make- EPC/ Equivalent]
Supply & Fixing of 250V. 50 Hz. 18", 80 Watt Metal Body, Metal blade wall bracket fan having 45 cm (450 mm) sweep, Air Displacement In M3/Hour-4500, Speed 1320 rpm non-oscillating type aerody.namically balanced, full metal body & Blade and a Strong base for stability,on wall with all accessories (Make : EPC= wall bracket/ Crompton-ACVORTEX18WM /Eq.) (as per choice of EIC)
Dismantling of 1.5 ton/ 2.0 ton Air Conditioner outdoor unit (Split type, Cassette type) after gas locking arrangement with necessary tools & tackels and store in safe place & Re-installation the same of 1.5 ton/ 2.0 ton Air Conditioner outdoor unit with necessary arrangement as per directionn of EIC
SITC incl. vacuumization and Nitrogen of testing of following nominal size of soft/hard drawn Cu. refrigerant piping for Pac/ VRV/VRF/RAC system, complete with fitting, with adjustable ring type hanger supports, jointing/brazing incl. accessories, insulated with XLPE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specification etc. as required. 5/8”(15.88 mm)dia(Soft drawn) Cu. Pipes(As per standard BS864 or ANSIB 16.22)incl. 19 mm thick insulation.
1/4” (6.4 mm) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 19 mm thick insulation.
Supply and laying PVC Drain Pipe 25mm dia with 6 mm thick Nitrile Rubber Insulation. [Make:- Suprime/Oriplast]
FRAME WORK: Supply, fabrication and installation of MS base frame for Split type Air conditioner outdoor units.:- Supplying, fabrication & fixings MS U-channel of 6 mm thick of size (75mm x 40mm x 40mm) for making Base Frame/ platform for installation of outdoor unit of above mentioned AC machines incl drilling 2 nos holes in each channel, cutting holes into the wall & grouting the same with C.C. (1:1.5:3) etc. fabricated with horizontal angle of 25mm x 25mm x 6mm and supporting angle of 50mm x 50mm x 6mm in each platform in the outer edge for transmitting the load centrally through 2 nos(50mm x 50mm x 6 mm) angle inserted into the existing wall incl. fibre sheet shade as directed by E.I.C. The entire structure must be safe to carry out maintenance of ODU. for mounting of AC machine outdoor Unit with platform arrangement for proper maintenance at 3rd floor in appropriate way .(10 nos X 114 kg= 1140 kg)
Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge. (This item should be executed only after prior approval of the Engineer-incharge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. If necessary further after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly. (a) 3.9 meter height
(b) Extra for additional 3.6 height or part there of Note : 1) Suitable quantity of Common / Regular EI materials like wires, Pipes, piano key type & modular type switches, sockets, MCB of different ratings, modular type switch boards, LED fittings, LED driver etc. should be stored at site by the Agency in advance with his own responsibility to overcome emergency situations. 2) Works through requisition (i.e, Regular work) should be started within 16 hrs & the emergency breakdown works should be started within 4 hrs with requisite manpower after getting the information either from site or from office. Each individual work must be completed with minimum executing time as per site requirement. 3) The Agency must submit the details of communicating person in this regard along with his Mobile number & Email id.
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
ANNAPURNA ELECTRICALS (BID ID -6720954)
STANDARD BUILDERS (BID ID -6721012)
OVERSEAS TRADING AND SUPPLIES CORPORATION (BID ID -6720859)
ELECTROTECH (BID ID -6737082)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .