| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC being lowest bidder |
| 2 | L2₹1.5 Cr+₹14.5 L (10.7%)Rejected-Finance | ₹1.5 Cr+₹14.5 L (10.7%) | L2 | Rejected-Finance Other Than Lowest bidder |
| 3 | L3₹1.5 Cr+₹19.5 L (14.5%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | ₹1.5 Cr+₹19.5 L (14.5%) | L3 | Rejected-Finance Other Than Lowest bidder |
| 4 | L4₹1.6 Cr+₹20.7 L (15.3%)Rejected-Finance HOUSE NO 89 BEHIND DD LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | ₹1.6 Cr+₹20.7 L (15.3%) | L4 | Rejected-Finance Other Than Lowest bidder |
| 5 | L5₹1.6 Cr+₹29.4 L (21.8%)Rejected-Finance | ₹1.6 Cr+₹29.4 L (21.8%) | L5 | Rejected-Finance Other Than Lowest bidder |
Tender Value
Refer Docs
EMD Value
₹2.4 L
Closing Date
25 Mar 2022, 6:00 pmClosed
Chief Engineer Leh
HQ Chief Engineer Leh Zone, Leh Pin-901205
AUGMENTATION OF EXTERNAL ELECTRIFICATION FOR MTN BDE DRASS
2021_MES_493755_2
180077/E8
Open Tender
Electrical and Maintenance Works
Item Rate
540 days
Drass
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE Kargil
₹2.4 L
Yes
24 May 2022
11 Feb 2022
28 Mar 2022
11 Feb 2022
25 Mar 2022
12 Mar 2022
11 Feb 2022 - 27 Feb 2022
Amount
Excavation in trenches/foundation in soft/loose/hard soil, not exceeding 1.5m wide and not exceeding 1.5 m in depth for underground cables/ pole & stay foundation/pipe etc and getting out incl forming bottom surface to required level or stop complete all as specified and directed.
All as per item No 1 above but not exceeding 1.5 m and not exceeding 3m in depth.
Removal of surplus excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick in hard/dense soil complete all as specified.
Sand cushioning with fine sand to under ground cables in ducts or in trenches of layer 23cm thick (8 cm before laying the cable and 15 cm thick after laying the cable in layers), complete all as specified and directed by Engr-In-Charge.
Supply and laying un reinforced precast concrete cable cover class HV, type I, flat, size 300 mm x 180 mm x 40 mm, complete all as specified and directed by Engr-In-Charge. Note : Manufacturer test certificate shall be submitted by the contractor.
Supply and laying un reinforced precast concrete cable cover class LV, type I, flat, size 250 mm x 150 mm x 40 mm, complete all as specified and directed by Engr-In-Charge. Note : Manufacturer test certificate shall be submitted by the contractor.
Supply and laying GI tubes light grade 40mm bore laid in trenches/across roads/alongwith walls/poles as protection to cables, complete all as specified and directed by the Engr-in-Charge. Note : Nut, bolt, washer and clamps for fixing of pipe alongwith wall/pole shall be measured and paid separately under respective item i.e item No -36.
Supply and laying GI tubes light grade 80mm bore laid in trenches/across roads/alongwith walls/poles as protection to cables, complete all as specified and directed by the Engr-in-Charge. Note : Nut, bolt, washer and clamps for fixing of pipe alongwith wall/pole shall be measured and paid separately under respective item i.e item No -36.
Supply and laying in trenches/ducts or fixing on wall/pole or laying through pipe XLPE insulated, armoured, electric power cable heavy duty with aluminium conductor, 1100 volts, grade cross sectional area 16 sqmm 2 core, complete all as specified and directed by the Engr-in-Charge. Note : Earth work for laying of LT cable/pipes shall be measured and paid separately under respective items.
Supply and laying in trenches/ducts or fixing on wall/pole or laying through pipe XLPE insulated, armoured, electric power cable heavy duty with aluminium conductor, 1100 volts, grade cross sectional area 25 sqmm 4 core, complete all as specified and directed by the Engr-in-Charge. Note : Earth work for laying of LT cable/pipes shall be measured and paid separately under respective items.
Supply and laying in trenches/ducts or fixing on wall/pole or laying through pipe XLPE insulated, armoured, electric power cable heavy duty with aluminium conductor, 1100 volts, grade cross sectional area 50 sqmm 3.5 core, complete all as specified and directed by the Engr-in-Charge. Note : Earth work for laying of LT cable/pipes shall be measured and paid separately under respective items.
Supply and laying in trenches/ducts or fixing on wall/pole or laying through pipe XLPE insulated, armoured, electric power cable heavy duty with aluminium conductor, 1100 volts, grade cross sectional area 70 sqmm 3.5 core, complete all as specified and directed by the Engr-in-Charge. Note : Earth work for laying of LT cable/pipes shall be measured and paid separately under respective items.
Supply and laying in trenches/ducts or fixing on wall/pole or laying through pipe XLPE insulated, armoured, electric power cable heavy duty with aluminium conductor, 1100 volts, grade cross sectional area 120 sqmm 3.5 core, complete all as specified and directed by the Engr-in-Charge. Note : Earth work for laying of LT cable/pipes shall be measured and paid separately under respective items.
Supply and laying in trenches/ducts or fixing on wall/pole or laying through pipe XLPE insulated, armoured, electric power cable heavy duty with aluminium conductor, 1100 volts, grade cross sectional area 240 sqmm 3.5 core, complete all as specified and directed by the Engr-in-Charge. Note : Earth work for laying of LT cable/pipes shall be measured and paid separately under respective items.
Supply and laying in trenches/ducts or fixing on wall/pole or laying through pipe XLPE insulated, armoured, electric power cable heavy duty with aluminium conductor, 1100 volts, grade cross sectional area 300 sqmm 3.5 core, complete all as specified and directed by the Engr-in-Charge. Note : Earth work for laying of LT cable/pipes shall be measured and paid separately under respective items.
Supply and laying in trenches/ducts or fixing on wall/pole or laying through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade rated with suitable earthed system cross sectional area 95 sqmm, 3 Core complete including connecting both ends with proper size of aluminium lugs duly crimped with die press crimping device and cable gland all as specified and directed by Engr in charge. Note:- Earthwork for laying of LT cable/jointing kits, Cable protection pipes shall be measured and paid seperately under respective items.
Supply and laying in trenches/ducts or fixing on wall/pole or laying through pipe XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade rated with suitable earthed system sectional area 120 sqmm, 3 Core complete including connecting both ends with proper size of aluminium lugs duly crimped with die press crimping device and cable gland all as specified and directed by Engr in charge. Note:- Earthwork for laying of LT cable/jointing kits, Cable protection pipes shall be measured and paid seperately under respective items.
S&F of Cable jointing kit for 11000 volt (Earthed) grade cable for outdoor end termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engr in charge.
S&F of Cable jointing kit for 11000 volt (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, complete all as specified and directed by Engr in charge.
S&F Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, Single disc assembly for 11000 volts, complete all as specified and directed by Engr in charge.
Supply and fixing of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp for 11000 volts, complete all as specified and directed by Engr in charge.
Supply and fixing of gang operated air break switch Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps for 11000 volts, complete all as specified and directed by Engr in charge.
Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-55 (11.00 meters long) with cast iron base frame, finial taper plug, bolts, nuts and screws,including facctory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cm wide strip with yellow and black paint at alternate upto 1.5m, height and apply two coat of redoxide primer on remaining exposed surface after erection complete all as specified and directed by Engr in charge. Note : 1. Necessary excavation and earth work, PCC work for foundation shall be measured and paid separately under respective items. 2. Manufacture test certificate shall be submitted by the contractor
Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-31 (9.00 meters long) with cast iron base frame, finial taper plug, bolts, nuts and screws, complete all as specified and directed by Engr in charge. Note : 1. Necessary excavation and earth work, PCC work for foundation shall be measured and paid separately under respective items. 2. Manufacture test certificate shall be submitted by the contractor
S&F in ACSR conductor of (weasel) 6/2.59, straching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span etc complete all as specified and as directed by Engineer-in-charge.
S&F Stay assembly complete with GI stay rod 20mm dia 1800 mm long, with accessories complete all as specified in electrical plate No 1 of SSR Part-1 complete all as specified and directed by the Engr-in-Charge. (loop type insulator, excavation and concrete measured seperately).
S&F Loop type insulator vitreous procelain white, brown or green large size with overall dimension 90mmx140mm clearance of hole 25.5 mm, complete all as specified and directed by Engr in charge.
S&F Cable route indicator of size 15cm x15cm x75cm in length with projection of 45cm above ground level and 30cm grouted in PCC foundation, PCC shall be painted with yellow colour above ground and HT 11000 Volt/LT 1100 Volt marked in red colour complete all as specified and directed by Engr in charge. Note:-Rate quoted by the contractor are inclusive of earth work, paint and PCC foundation.
S&F Shackle Type, Porcelain, vitreous, white, brown or green insulator of height 100 mm and dia 115 mm for 1100 volt line including galvanised mild steel straps of size 31x5 mm , washers, insulator bolt of dia 14 mm, washers and nuts, as specified and directed by Engr-in-Charge.
S&F Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole, as specified and directed by Engr-in-Charge.
S&F of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by the Engr-in-Charge.
S&F of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 25x15cm size complete all as specified and directed by the Engr-in-Charge.
M&L Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling of steel pole and mass concrete, complete all as specified and directed by the Engr-in-Charge.
M&L Plain cement concrete 1:3:6 type C-1 (using 20mm grade aggregate) as in foundation filling of stay assy and coping of steel pole including all necessary form works complete all as specified and directed by Engineer-in-Charge
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engr-in-Charge.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard dense soil complete all as specified and directed by engineer in charge
M&L for shingle filling in floors or pavings, laid in layers not exceeding 15cm thick, spread, levelled, and blinded with earth and rammed including watering complete all as specified and directed.
Supplying, installing, connecting, commissioning and testing of transformer outdoor type step down 11/0.433 KV (at no load) with HT 3 phase and LT 3 phase 4 wire AC, 50 Hz, 100 KVA, copper wound with off load tap changing arrangment on HT side for a variation of secondary voltage +/- 7.5% in steps of +/- 2.5% including suitable cable entry boxes on LT side and HT Bushing on primery side complete in all respects with standard accessories and fitments conforming to IS 1180(Part-I):2014 (Level-2) BIS/BEE Certified and latest ECBC as specified and directed including the following:- (a) Earthing terminal and rating diagram plate. (b) Air release device. (c) Oil filling inlet pipe with plug. (d) Drain outlet pipe with brass gate valve with dummy plug. (e) Conservator with level gauge. (f) Silica gel with breather. (g) First oil fill up to the recommended level by the manufacturer with new oil conforming to IS 335. (h) Type of connection - Delta/Star. (j) Type cooling -ONAN. (k) Vector group - DYN 11. (l) Type of connecting arrangment - ACSR conductor connection on HT side and cable connection box on LT side. (m) Provision of thermometer with pocket. (n) Oil and winding alarm and trip relay including marshal box. (o) The transformer of 100 KVA full capacity shall be designed to function properly at high altitude of appx 3500m above sea level and outside temperature conditions between -40 degree celsius to +30 degree celsius. (p) Factory inspection shall be carried out for transformer.
Supplying, installing, connecting, commissioning and testing of transformer outdoor type step down 11/0.433 KV (at no load) with HT 3 phase and LT 3 phase 4 wire AC, 50 Hz, 200 KVA, copper wound with off load tap changing arrangment on HT side for a variation of secondary voltage +/- 7.5% in steps of +/- 2.5% including suitable cable entry boxes on LT side and HT Bushing on primery side complete in all respects with standard accessories and fitments conforming to IS 1180(Part-I):2014 (Level-2) BIS/BEE Certified and latest ECBC as specified and directed including the following:- (a) Earthing terminal and rating diagram plate. (b) Air release device. (c) Oil filling inlet pipe with plug. (d) Drain outlet pipe with brass gate valve with dummy plug. (e) Conservator with level gauge. (f) Silica gel with breather. (g) First oil fill up to the recommended level by the manufacturer with new oil conforming to IS 335. (h) Type of connection - Delta/Star. (j) Type cooling -ONAN. (k) Vector group - DYN 11. (l) Type of connecting arrangment - ACSR conductor connection on HT side and cable connection box on LT side. (m) Provision of thermometer with pocket. (n) Oil and winding alarm and trip relay including marshal box. (o) The transformer of 200 KVA full capacity shall be designed to function properly at high altitude of appx 3500m above sea level and outside temperature conditions between -40 degree celsius to +30 degree celsius. (p) Factory inspection shall be carried out for transformer.
Supplying, installing, connecting, commissioning and testing of transformer outdoor type step down 11/0.433 KV (at no load) with HT 3 phase and LT 3 phase 4 wire AC, 50 Hz, 250 KVA, copper wound with off load tap changing arrangment on HT side for a variation of secondary voltage +/- 7.5% in steps of +/- 2.5% including suitable cable entry boxes on LT side and HT Bushing on primery side complete in all respects with standard accessories and fitments conforming to IS 1180(Part-I):2014 (Level-2) BIS/BEE Certified and latest ECBC as specified and directed including the following:- (a) Earthing terminal and rating diagram plate. (b) Air release device. (c) Oil filling inlet pipe with plug. (d) Drain outlet pipe with brass gate valve with dummy plug. (e) Conservator with level gauge. (f) Silica gel with breather. (g) First oil fill up to the recommended level by the manufacturer with new oil conforming to IS 335. (h) Type of connection - Delta/Star. (j) Type cooling -ONAN. (k) Vector group - DYN 11. (l) Type of connecting arrangment - ACSR conductor connection on HT side and cable connection box on LT side. (m) Provision of thermometer with pocket. (n) Oil and winding alarm and trip relay including marshal box. (o) The transformer of 250 KVA full capacity shall be designed to function properly at high altitude of appx 3500m above sea level and outside temperature conditions between -40 degree celsius to +30 degree celsius. (p) Factory inspection shall be carried out for transformer.
Supplying, installing, connecting, commissioning and testing of transformer outdoor type step down 11/0.433 KV (at no load) with HT 3 phase and LT 3 phase 4 wire AC, 50 Hz, 315 KVA, copper wound with off load tap changing arrangment on HT side for a variation of secondary voltage +/- 7.5% in steps of +/- 2.5% including suitable cable entry boxes on LT side and HT Bushing on primery side complete in all respects with standard accessories and fitments conforming to IS 1180(Part-I):2014 (Level-2) BIS/BEE Certified and latest ECBC as specified and directed including the following:- (a) Earthing terminal and rating diagram plate. (b) Air release device. (c) Oil filling inlet pipe with plug. (d) Drain outlet pipe with brass gate valve with dummy plug. (e) Conservator with level gauge. (f) Silica gel with breather. (g) First oil fill up to the recommended level by the manufacturer with new oil conforming to IS 335. (h) Type of connection - Delta/Star. (j) Type cooling -ONAN. (k) Vector group - DYN 11. (l) Type of connecting arrangment - ACSR conductor connection on HT side and cable connection box on LT side. (m) Provision of thermometer with pocket. (n) Oil and winding alarm and trip relay including marshal box. (o) The transformer of 315 KVA full capacity shall be designed to function properly at high altitude of appx 3500m above sea level and outside temperature conditions between -40 degree celsius to +30 degree celsius. (p) Factory inspection shall be carried out for transformer.
Supplying, installing, connecting, commissioning and testing of transformer outdoor type step down 11/0.433 KV (at no load) with HT 3 phase and LT 3 phase 4 wire AC, 50 Hz, 400 KVA, copper wound with off load tap changing arrangment on HT side for a variation of secondary voltage +/- 7.5% in steps of +/- 2.5% including suitable cable entry boxes on LT side and HT Bushing on primery side complete in all respects with standard accessories and fitments conforming to IS 1180(Part-I):2014 (Level-2) BIS/BEE Certified and latest ECBC as specified and directed including the following:- (a) Earthing terminal and rating diagram plate. (b) Air release device. (c) Oil filling inlet pipe with plug. (d) Drain outlet pipe with brass gate valve with dummy plug. (e) Conservator with level gauge. (f) Silica gel with breather. (g) First oil fill up to the recommended level by the manufacturer with new oil conforming to IS 335. (h) Type of connection - Delta/Star. (j) Type cooling -ONAN. (k) Vector group - DYN 11. (l) Type of connecting arrangment - ACSR conductor connection on HT side and cable connection box on LT side. (m) Provision of thermometer with pocket. (n) Oil and winding alarm and trip relay including marshal box. (o) The transformer of 400 KVA full capacity shall be designed to function properly at high altitude of appx 3500m above sea level and outside temperature conditions between -40 degree celsius to +30 degree celsius. (p) Factory inspection shall be carried out for transformer.
Earthing complete with steel earth plate electrode 600mmx600mmx6mm thick buried directly in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connecting to the galvanised iron earth wire 4.0mm dia by means of bolts, nuts, check nuts and washers of GI and steel earth wire complete all as shown in electrical plate No.3 and connected to earth test point and testing shall be done and resistance of earthing less the 1 ohm, complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level, connected to GI strip 32x6 mm as earthling lead by means blots and nuts check nuts and washers of galvanized iron or steel as shown in electrical plate No. 3 connected to Earthing test point and testing shall be done and resistance of earthing less the 1 ohm, complete all as specified and directed.
Supply and installation of 11 KV, single phase, outdoor oil cooled CT of ratio 400/1-5Amp, class 0.5/5P10, burden 15 VA,to be pole mounted complete all as specified and directed by Engr-in-Charge.
Supply and installation of 11 KV, single phase, outdoor oil cooled PT of ratio 11 KV/rt3/110 V/rt3/110V/rt3, class 0.5-3, Burden 50 VA-50 VA,to be pole mounted complete all as specified and directed by Engr-in-Charge.
Supply and fix Microprocessor based three phase electronic tamper proof HT Energy meter Cubical type with optical communication port, accuracy class 0.5 rating 3 x 110 V, 1/5 A confirming to IS:13779, complete all as specified and directed by Engr-in-Charge. Note:- 1.Meter should be enclosed with suitable enclousere for fixing on pole with transperent display and all necessary connection arrangement for control wire connection from CT, PT, to HT meter is included in quoted rate of respective item. 2. Meter should match the rating for CT, PT mentioned in item No 46 & 47 respectively
Supply and installation erection commissioing and testing of main LT panel cubical out door type weather/dust proof, factory made out of 3.15mm thick CRCA sheet powder coated CPRI Approved with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system includign four pole copper bus bar 200 amps capacity including control wiring with suitable size but not less then 2.5 sqmm of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45m on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:- Note:- 1. Rate quoted by the contractor are inclusive of earth work, PCC foundation and all connected accessories. 2. LT panel shall be inspected by the repersentative of accepting officer at factory/manufacturers workshop premises before dispatch. 3. Busbar: Electrolytic high conducting copper three pole and neutral busbars rated at 200Amps (after deration) having a maximum current density of 1 Amp per Sqmm with insulated heat shrinkable PVC sleeves
MCCB 4 pole 415 volts 100 Amps, Icu=Ics= 25 KA - 01 No (Incoming)
MCCB 3 pole 415 volts 63 Amps, Icu=Ics= 16 KA - 02 Nos
MCB SPN 40 A, 240 V class "C"- 04 Nos.
Ammeter 0-200 Amps, accuracy class 0.5 CL size 4"x4" digital along with suitable size CT's-03 Nos (one per Phase)-03 Nos
Volt meter 0-500 volts size 4"x4" digital - 01 No
LED indicator lamp(RYB) - 01 Set
Supply and installation erection commissioing and testing of main LT panel cubical out door type weather/dust proof, factory made out of 3.15mm thick CRCA sheet powder coated CPRI Approved with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system includign four pole copper bus bar 200 amps capacity including control wiring with suitable size but not less then 2.5 sqmm of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45m on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:- Note:- 1. Rate quoted by the contractor are inclusive of earth work, PCC foundation and all connected accessories. 2. LT panel shall be inspected by the repersentative of accepting officer at factory/manufacturers workshop premises before dispatch. 3. Busbar: Electrolytic high conducting copper three pole and neutral busbars rated at 200Amps (after deration) having a maximum current density of 1 Amp per Sqmm with insulated heat shrinkable PVC sleeves
MCCB 4 pole 415 volts 100 Amps, Icu=Ics= 25 KA - 01 No (Incoming)
MCCB 3 pole 415 volts 63 Amps, Icu=Ics= 16 KA - 03 Nos
MCB SPN 40 A , 240 V class "C"- 05 Nos.
Ammeter 0-200 Amps, accuracy class 0.5 CL size 4"x4" digital along with suitable size CT's-03 Nos (one per Phase)- 03 Nos
Volt meter 0-500 volts size 4"x4" digital - 01 No
LED indicator lamp(RYB) - 01 Set
Supply and installation erection commissioing and testing of main LT panel cubical out door type weather/dust proof, factory made out of 3.15mm thick CRCA sheet powder coated CPRI Approved with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45cm height for 433 volts, 3 phase, 4 wire system includign four pole copper bus bar 600 amps capacity including control wiring with suitable size but not less then 2.5 sqmm of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45m on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:- Note 1. Rate quoted by the contractor are inclusive of earth work, PCC foundation and all connected accessories. 2. LT panel shall be inspected by the rep of accepting officer at factory/manufacturers workshop premises before dispatch. 3. Busbar: Electrolytic high conducting copper three pole and neutral busbars rated at 600Amps (after deration) having a maximum current density of 1 Amp per Sqmm with insulated heat shrinkable PVC sleeves
Incoming MCCB 4 pole 415 volts 400 Amps, Icu=Ics= 36 KA - 01 No
MCCB 3 pole 415 volts 315 Amps, Icu=Ics= 36 KA - 01 No
MCCB 3 pole 415 volts 250 Amps, Icu=Ics= 36 KA - 01 No
Ammeter 0-400 Amps, accuracy class 0.5 CL size 4"x4" digital along with suitable size CT's- 03 Nos (one per Phase)- 03 Nos
Volt meter 0-500 volts size 4"x4" digital - 01 No
LED indicator lamp(RYB) - 01 Set
Supply and installation erection commissioing and testing of main LT panel cubical out door type weather/dust proof, factory made out of 3.15mm thick CRCA sheet powder coated CPRI Approved with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system includign four pole copper bus bar 1000 amps capacity including control wiring with suitable size but not less then 2.5 sqmm of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45m on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:- Note:- 1. Rate quoted by the contractor are inclusive of earth work, PCC foundation and all connected accessories. 2. LT panel shall be inspected by the repersentative of accepting officer at factory/manufacturers workshop premises before dispatch. 3. Busbar: Electrolytic high conducting copper three pole and neutral busbars rated at 1000Amps (after deration) having a maximum current density of 1 Amp per Sqmm with insulated heat shrinkable PVC sleeves
MCCB 4 pole 415 volts 630 Amps, Icu=Ics= 50 KA - 01 No (Incoming)
MCCB 3 pole 415 volts 100 Amps, Icu=Ics= 16 KA - 01 No
MCCB 3 pole 415 volts 63 Amps, Icu=Ics= 16 KA - 13 Nos
MCB SPN 40 A, 240 V class 'C'- 01 No
Ammeter 0-800 Amps, accuracy class 0.5 CL size 4"x4" digital along with suitable size CT's-03 Nos (one per Phase)-03 Nos
Volt meter 0-500 volts size 4"x4" digital - 01 No
LED indicator lamp(RYB) - 01 Set
Supply and installation erection commissioing and testing of main LT panel cubical out door type weather/dust proof, factory made out of 3.15mm thick CRCA sheet powder coated CPRI Approved with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system includign four pole copper bus bar 600 amps capacity including control wiring with suitable size but not less then 2.5 sqmm of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45m on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:- Note:- 1. Rate quoted by the contractor are inclusive of earth work, PCC foundation and all connected accessories. 2. LT panel shall be inspected by the repersentative of accepting officer at factory/manufacturers workshop premises before dispatch. 3. Busbar: Electrolytic high conducting copper three pole and neutral busbars rated at 600Amps (after deration) having a maximum current density of 1 Amp per Sqmm with insulated heat shrinkable PVC sleeves
MCCB 4 pole 415 volts 400 Amps, Icu=Ics= 36 KA - 01 No (Incoming)
MCCB 3 pole 415 volts 250 Amps, Icu=Ics= 36 KA - 02 Nos
MCCB 3 pole 415 volts 125 Amps, Icu=Ics= 16 KA - 01 No
Ammeter 0-600 Amps, accuracy class 0.5 CL size 4"x4" digital along with suitable size CT's-03 Nos (one per Phase)-03 Nos
Volt meter 0-500 volts size 4"x4" digital - 01 No
LED indicator lamp(RYB) - 01 Set
Supply and installation erection commissioing and testing of main LT panel cubical out door type weather/dust proof, factory made out of 3.15mm thick CRCA sheet powder coated CPRI Approved with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system includign four pole copper bus bar 200 amps capacity including control wiring with suitable size but not less then 2.5 sqmm of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45m on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:- Note:- 1. Rate quoted by the contractor are inclusive of earth work, PCC foundation and all connected accessories. 2. LT panel shall be inspected by the repersentative of accepting officer at factory/manufacturers workshop premises before dispatch. 3. Busbar: Electrolytic high conducting copper three pole and neutral busbars rated at 200Amps (after deration) having a maximum current density of 1 Amp per Sqmm with insulated heat shrinkable PVC sleeves
Incoming MCCB 4 pole 415 volts 100 Amps, Icu=Ics= 25 KA - 01 No
MCCB 3 pole 415 volts 63 Amps, Icu=Ics= 16 KA - 03 Nos
MCB SPN 40 A, 240 V class 'C' - 02 Nos.
Ammeter 0-200 Amps, accuracy class 0.5 CL size 4"x4" digital along with suitable size CT's-03 Nos (one per Phase)-03 Nos
Volt meter 0-500 volts size 4"x4" digital - 01 No
LED indicator lamp(RYB) - 01 Set
Supply and installation erection commissioing and testing of main LT panel cubical out door type weather/dust proof, factory made out of 3.15mm thick CRCA sheet powder coated CPRI Approved with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system includign four pole copper bus bar 400 amps capacity including control wiring with suitable size but not less then 2.5 sqmm of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45m on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:- Note:- 1. Rate quoted by the contractor are inclusive of earth work, PCC foundation and all connected accessories. 2. LT panel shall be inspected by the repersentative of accepting officer at factory/manufacturers workshop premises before dispatch. 3. Busbar: Electrolytic high conducting copper three pole and neutral busbars rated at 400Amps (after deration) having a maximum current density of 1 Amp per Sqmm with insulated heat shrinkable PVC sleeves
Incoming MCCB 4 pole 415 volts 160 Amps, Icu=Ics= 36 KA - 01 No
MCCB 3 pole 415 volts 125 Amps, Icu=Ics= 16 KA - 03 Nos
Ammeter 0-400 Amps, accuracy class 0.5 CL size 4"x4" digital along with suitable size CT's-03 Nos (one per Phase)-03 Nos
Volt meter 0-500 volts size 4"x4" digital - 01 No
LED indicator lamp(RYB) - 01 Set
Supply and installation erection commissioing and testing of main LT panel cubical out door type weather/dust proof, factory made out of 3.15mm thick CRCA sheet powder coated CPRI Approved with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system includign four pole copper bus bar 600 amps capacity including control wiring with suitable size but not less then 2.5 sqmm of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45m on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:- Note:- 1. Rate quoted by the contractor are inclusive of earth work, PCC foundation and all connected accessories. 2. LT panel shall be inspected by the repersentative of accepting officer at factory/manufacturers workshop premises before dispatch. 3. Busbar: Electrolytic high conducting copper three pole and neutral busbars rated at 600Amps (after deration) having a maximum current density of 1 Amp per Sqmm with insulated heat shrinkable PVC sleeves
MCCB 4 pole 415 volts 400 Amps, Icu=Ics= 36 KA - 01 No (Incoming)
MCCB 3 pole 415 volts 250 Amps, Icu=Ics= 36 KA - 02 Nos
MCCB 3 pole 415 volts 200 Amps, Icu=Ics= 36 KA - 01 No
Ammeter 0-500 Amps, accuracy class 0.5 CL size 4"x4" digital along with suitable size CT's-03 Nos (one per Phase)-03 Nos
Volt meter 0-500 volts size 4"x4" digital - 01 No
LED indicator lamp(RYB) - 01 Set
Supply and installation erection commissioing and testing of main LT panel cubical out door type weather/dust proof, factory made out of 3.15mm thick CRCA sheet powder coated CPRI Approved with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system includign four pole copper bus bar 400 amps capacity including control wiring with suitable size but not less then 2.5 sqmm of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45m on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:- Note:- 1. Rate quoted by the contractor are inclusive of earth work, PCC foundation and all connected accessories. 2. LT panel shall be inspected by the repersentative of accepting officer at factory/manufacturers workshop premises before dispatch. 3. Busbar: Electrolytic high conducting copper three pole and neutral busbars rated at 400Amps (after deration) having a maximum current density of 1 Amp per Sqmm with insulated heat shrinkable PVC sleeves
MCCB 4 pole 415 volts 250 Amps, Icu=Ics= 36 KA - 01 No (Incoming)
MCCB 3 pole 415 volts 200 Amps, Icu=Ics= 36 KA - 02 Nos
MCCB 3 pole 415 volts 63 Amps, Icu=Ics= 16 KA - 01 No
Ammeter 0-400 Amps, accuracy class 0.5 CL size 4"x4" digital along with suitable size CT's-03 Nos (one per Phase)-03 Nos
Volt meter 0-500 volts size 4"x4" digital - 01 No
LED indicator lamp(RYB) - 01 Set
M&L for hardcore with broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by engineer in charge
M&L for rendering 15mm thick cement plaster in cement motor (1:4) finished even & fair without using exter cement on brick/concrete surfaces complete all as specified and directed by engineer in charge.
M&L for two coats of cement based paint on newly plastered surfaces of walls including prepration of surfaces complete all as specified and directed by engineer in charge.
M&L for 75mm thick plain cement concrete 1:3:6 type C-2 (using 40 mm graded aggregate) as in plinth protection complete all as specified and directed by engineer in charge.
M&L for 40mm thick plain cement concrete 1:2:4 type B-1 (using 20 mm graded aggregate) as in flooring including finishing top even & smooth without using extra cement complete all as specified and directed by engineer in charge.
S&F Joist, channel, angle or tee sections, fixed independently, without connecting plates, etc (cut to ordinary lengths I.e within 20mm of the length indicated) Fe-410-W (Gde E-250) quality 'A' complete all as specified and directed by engineer in charge.
Supply and fixing mild steel framed work as in door or gates of angle or other sections with gusset plates rails, braces etc complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and purpose made hinges or steel sheeting or other covering, running rails and guides and hanging, fastening and fixing complete conforming to Fe 290 Gde E-165 complete all as specified and directed by engineer in charge. Note: 1. Machine butt hinges and flat iron hold fasts to be measured seperately
S&F of butt hinges 100mm size, medium weight cold rolled mild steel and fixed to angle iron/steel chowkhat complete all as specified and directed by engineer in charge.
S&F mild steel sliding door bolts, 250mm long, plate type, stove enamelled black, with bright bolts not less than 12mm dia with and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed by engineer in charge.
Supply only chain link MS galvanised fencing, any size or type complete all as specified and directed by engineer in charge
Fixing only chain link fencing including line wires, any mesh, size and any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as directed by engineer in charge.
M&L for prepration of new or previously untreated steel surfaces of any description over 10cm in width or grith not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by engineer in charge.
Supplying and laying reinforced precast concrete cable cover, class EHV, type-I with peak, size 450mm X 230mm X 50mm complete all as specified and directed by engineer in charge
M&L for precast cement concrete type C-I block mansory with solid blocks 1:3:6 ( using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortor (1:6) complete all as specified and directed by engineer in charge
M/S Inderjit Sharma and Co.
SUMEET TRADING CORPORATION
M/S HIGHLAND ENGINEERING
Intrernational Engineers
M/S JIWAN KUMAR MITTAL
M/s M. S Naqvi and Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .