Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC | ₹1.9 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.9 Cr+₹16,586 (0.09%)Rejected-AOC | ₹1.9 Cr+₹16,586 (0.09%) | L2 | Rejected-AOC L2 |
| 3 | L3₹1.9 Cr+₹37,126 (0.19%)Rejected-AOC C O SOBHA RAMCHIARY VILL GOLDINGPARA P O PAMUA PATHAR P S MUSHALPUR DIST BAKSA BTC ASSAM PIN 781372 | GOLDINGPARA | BAKSA | ASSAM | 781372 | ₹1.9 Cr+₹37,126 (0.19%) | L3 | Rejected-AOC L3 |
Tender Value
₹1.9 Cr
EMD Value
₹3.9 L
Closing Date
30 Oct 2019, 4:30 pmClosed
Sri J.M. Basumatary
Addl. Chief Engineer cum Director, PWD BTC Kokrajhar
Construction of RCC G plus 2 Administrative Building of Gyanpith Degree College Nikashi in Baksa District
2019_BTC_14426_1
ACE/29/TECH/MSL/IFB/2019/30
Open Tender
Civil Works - Building
Works
365 days
Baksa
Building Construction
6 documents required · 6 mandatory
₹5,900
Yes
Principal Secretary, BTC Kokrajhar
₹3.9 L
Yes
13 May 2020
17 Oct 2019
31 Oct 2019
17 Oct 2019
30 Oct 2019
17 Oct 2019
17 Oct 2019 - 30 Oct 2019
Amount
Earth Work: Earth Work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps, septic tank etc., including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified. (A) Upto a depth of 2m below the existing ground level. (b) In hard/dense soil
Earth /Sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming, etc. complete as directed and specified including payment of land compensation, forest royalty, sale taxt and other duties and texes as may be necessary. (b) With hill sand obtained by truck carriage loading and unloading and carriage to the site of work.
Pre construction anti-termite treatment; Pre construction anti-termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water, i.e 1% solution.
SOLING WORKS:- Providing brick soling in foundation and under floor with stone/best quality picked Jhama brick, sand packed and laid to level and in panel after preparing the sub grade As directed including all lab our and materials and if necessary dewatering, complete. (C) Stone soling of thick 150mm
P.C.C WORK: Plain cement concrete works with coarse aggregate, of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (Shuttering where necessary shall be measured and paid separately). (c) In prop 1cement: 5sand: 10 coarse aggregate by volume
Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarse agg. Of size 13mm to 32mm including dewatering if necessary, and curing etc.complete. C) 100mm thick
Providing and laying 25mm thick Damp proof coarse with cement concrete in prop. 1:1.5:3 with graded stone agg. Of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacture including curing etc. complete as directed.
(R.C.C.) Reinforced cement concrete work: Providing and laying plain/reinforced cement concrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (i) Using mixture machine. (A) In sub-structure upto plinth level. Foundation, footings, columns with base, tie and plinth beam, pile cap, base, slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) Without using admixture, plasticiser, (b) M-20 or Proportion in 1:1.5:3
(B) In superstructure from plinth level to 1st floor level. (ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam girder, bressumer, cantilever, staircase (except spiral stair case and landing) including preparing the top surface and finishing of nosing. (N) Without using admixture, plasticiser, (b) M-20 or Proportion in 1:1.5:3
Extra over item No.2.2.1 (i) (B), above for each subsequent floor or part thereof above the 1st. Floor level.
Timber shuttering (Formwork) Providing formwork of formwork of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. heigth of propping and centering below supporting floor to ceiling not exiding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.1.1.1 Foundation, footings, base of column, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank
Column, pillars, post & Strut of quare/rectangular/polygonal in plain or any shape like Tee/L etc. Having plain vertical face. (ii) Using 25mm thick plank
Extra for each subsequent 1.0M height or part there of beyond the initial height of 4.0m as mentioned in item no. 3.2.1.
Sides of tie beams, grade beams etc. at or below ground level. (b) Using 25mm thick plank
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M (ii) Using 25mm thick plank
Extra for each subsequent 1.0M height or part there of beyond the initial height of 4.0m as mentioned in item no. 3.2.1.
Flate surfaces such as soffits of suspended floors, roofa, landings, cantilever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
Extra for each subsequent 1.0M height or part thereof beyond the initial height of 4.0m as mentioned in item no. 3.2.1
Reinforcement Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). (A) From Primary producer: TATA/SAIL/Jindal steel/ Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reinforcement bar
Extra over item 18.1.1 (a,b,c) for each subsequent floor or part thereof above 1st floor level.
Brick works (conventionally / fly ash):- 230mm thick brick wall in cement morter with 1st class brick including racking out joints and curing complete as directed in structure. (i) In Sub-structure upto plinth level including dewatering if necessary. (b) In proportion 1:4.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary. (b) In proportion 1:4.
1st class brick nogged wall in cement mortar including racking out joints and curing completed as directed in super structure above plinth upto 1st floor level (protruding M.S. rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately). (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4 (1 cement: 4 sand)
Extra for brick walling for each subsequent floor or part thereof the 1st floor level.
15mm thick cement plaster in single coat on single or hulf brick wall in interior plastering upto 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished event and smooth including curing completed as directed. (B) On fair side (b) In cement mortar in proportion 1:4.
Extra over item no. 6.2.1 to 6.2.5 for interior plastering above 1st floor level for every additional floors or part thereof including curing completed as directed. (a) On single coat plaster
20mm thick cement plaster in two coats, on single or hulf brick wall for interior brick up to 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (A) On rough side (backing coat 15mm and finishing coat 5mm thick). (b) In cement mortar in proportion 1:4.
Extra over item no. 6.2.1 to 6.2.5 for interior plastering above 1st floor level for every additional floors or part thereof including curing completed as directed. (a) On single coat plaster
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on wallls) including curing complete as directed. (145.70+21.78)=167.48
In 1st floor
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement:3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor.
VITRIFIED TILES (A) ON FLOOR Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ White cement slurry mixed with approved pigment ot match shade of tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). b) Executive range Somany/Orient/Nitco/Varmora/VITA/Marbito/Make i) of size 800mm x 800mm and above
In 1st floor
Antiskid tile: Providing Antiskid tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1cement : 3 coarse sand) approved make fix with Fix-A Tile (Choksey/Sika/Pedelite/Rouf) white cement complete at all level as specified and directed. (B) Vitrified (ii) Executive range-1 (Sizes 400mm x 400mm and above) (a) Somany made -VC Shield (Group-25) (406x406) mm Deluxe VC
In 1st floor
Providing 18mm thick Granite slab on vertical face of pedestal laid over 10mm thick base of cement mortar in prop. 1:3 (1 cement :3 coarse sand) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade.
In 1st floor
(C ) PAVERS Providing polished tiles of approved quality, size, shape of specified thickness on pavers over a base of 100mm compacted sand gravel including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with color of tiles and as approved and directed by the Department). (A) SUN ROCK HIGH CTS Tiles (Pavers) (a) Silicon (Pavers) 60mm thick
(B) On Walls Providing polishing ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirting over cement mortar bad 10mm thick in prop. 1:3 (1cement : 3 coarse and) including cutting where necessary finished with flush pointing with fix-A Tile (Chokey/Sika/Pedelite/Rouf) white cement slary mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (cement plastering to be measured and paid separat). Coloured pigment should be inconformity with colour of tiles as approved and directed by the department). (walls means both interiors and exteriors wall). c) Delux range Somany/Orient/Nitco/Varmora Make iv) of size 300mm x 600mm and above
In 1st floor
Providing, fitting and fixing anodised aluminium framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section of approved brand with door style of size 88mm x 45mm x 2.5mm, top rails 50mm x 45mm x 2mm lock rails 100mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cheat etc.complete as specifed and directed by the department at all levels, (i) 6mm clear glass
In 1st floor
Providing, fitting and fixing coloured anodised aluminium partition walls of standard sections of approved brand, joints mitred and welded (manufactured to relevant I.S. specification) and providing and fitting angle cleat, rubber gasket, bolting device screws etc. at all levels. (i) Partly 6mm thick glass panes and 12mm prelaminated ply board
In 1st floor
Providing, fitting and fixing 40mm x 48mm wood reinforced PVC chowkhats fixed to the columns/stiffeners/walls with necessary holfast/sleeves etc. as specified and directed at all levels.
In 1st floor
Providing, fitting and fixing 24mm/29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels. (Door fixtures and fittings to be measured and paid separately). b) 29mm thick
In 1st floor
WINDOWS / VENTILATORS Providing, fitting and fixing steel windows of standard rolled steel sections as per relevant I.S code, joints mitred and welded with 15mm x 13mm x 100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device, steel handles, pegs, stays of 300mm long etc. complete including providing 12mm x 12mm sq. bars duly welded to steel frame at not more than 12cm c/c applying a priming coat of red-lead paint etc. complete as per drawing. a) Openable
In 1st floor
GLASS FITTING Providing and fixing pin-headed glass 3mm thick beded in putty and fixed with/without wooden bidding including necessary cutting and glass to be required sized (payment for wooden bead shall be made separately). (i) Area of glass panes not exceeding 0.15m2
In 1st floor
Providing and fixing stainless steel (Grade 304) railing made of holle tubes, channel, plates etc. including welding, grinding, buffing, polishing making curvature (wherever required) and fitting the same with necessary stailess steel nuts and botts complete, i.c. fixing the ailing with necessary accessaries and stainless steel desh fasteners, stainless steel bolts etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approved of engineer incharge. (for payment only weight of stainless steel member is to be considerd. no extra for fixing accessories such as nuts, bolts, fastener etc. will be considered).
In 1st floor
COLLAPSIBLE GATE Providing and fixing in position collapsible M.S shutters with vertical channels 20mm x 10mm x 2mm braced with flat iron diagonals 20mm x 5mm size with top and bottom rails of T-iron 40mm x 40mm x 6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paid.
PELMET Providing and fixing 12mm thick and 150mm wide pelmet with 25mm dia wooden curtain rod and bracket including fixing with 15mm x 3mm M.S flat 100mm long plugs complete. (a) First class Indian Teak wood/Sisu wood
In 1st floor
Providing two coats of birla white care well putty (water resistant white based putty or concrete /mortar wall and ceiling both internal or external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistering the wall with sufficient quantity of clean water as specified and directed by the department. (total thickness of two coats is maximum 1.5mm) (ii) Thickness =1.0mm thick
In 1st floor
c) Applying one coat of distemper primer of approved brand and manufacture on wall surface after throughly brushing the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and papered smooth.
In 1st floor
f) Distempering with dry distemper of approved brand and manufacture (two coats) and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after throughly brushing the surface free from mortar droppings and other foreign matter and including preparing surface even and sand papered smooth. Area as primer in ground floor
In 1st floor
Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem "Rakshak" brand of required shade by thinning 1ltr. Of paint with 750ml of water to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department. b) Unicem Rakshak
In 1st floor
PAINTING ON STEEL AND OTHER METAL SURFACE Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i) Surface over 100mm in width or in girth. (a) High gloss (Asian paint/Berger paint/ICI paint/J&K paint/Nerolac).
In 1st floor
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royalty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (b) Other than Guwahati city
Supplying and placing of Office table, chairs, furnitures, lockers etc. as per directed by the deptt. In ground floor
In 1st floor
Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C Baffle wall, inlet and outlet etc are provided at suitable points complete as directed. (ix) 200 Users
Supplying and placing ferrocement water tanks of circular/rectangular shape over stagging with manhole cover with locking and clearing arrangement including providing pads of size as required for intel and outlet pipes complete as directed. (Stagging should be measured and paid separately). 1500 Lt capacity water tank
Providing plinth protection with bricks laid on edge and grouted with cement mortar 1:4 and finishing with cement pointing in prop. 1:1 complete.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc.as specified. ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with inital depth of 100mm.
Providing fitting and fixing of fire fighting (Extinguisher/Hydrant system) as per directed by the Deptt.
Electrification Wiring for light/fan/call bell point with 2x1.5 sq mm P.V.C insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic coper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent make as approved by the Deptt). with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push (Anchor Penta/Gold medal/Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/ Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the Deptt. 1.1.1 Short point up to 3.00 metre. Length.
1.1.2 Medium point up to 6.00 metre. Length.
1.1.3 Long point up to 10.00 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. Insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694 : 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/ Anchor or equivalent make as approved by the deptt.) with 19mm ISI marked casing 'n' capping (AKG/Precesion/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchore penta/Gold medal/Kolor kany. kom/Havells or equivalent make as approved by thee deptt.) GI/MS switch board (I.S.I. marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm cable to third pin of the plug socket etc. as required complete, when placed elsewhere. 1.2.1 Short point up to 3.00 metre length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq.mm. P.V.C insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel/Nicco/Anchor or Equivalent make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including providing and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta/Gold medal/Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/MS switch board (I.S.I. marked) with phenolic laminated sheet cover earth continuity with 2.5 sq.mm cable to the 3rd pin of the socket as required complete. 1.3.2 Medium point up to 6.00 metre. Length.
Wiring for drawing sub-main line with P.V.C insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel/Nicco/Anchor or Equivalent make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.1 With 2 x 2.5 sq.mm. + earth continuity with 1x1.5 sq.mm. in flat 19mm ISI marked casing 'n' capping system.
1.8.2 With 2 x 4 sq.mm. + earth continuity with 1x2.5 sq.mm. cable in flat 19mm ISI marked casing 'n' capping system.
1.8.3 With 2 x 6 sq.mm. + earth continuity with 1x4 sq.mm.cable in flat 25mm ISI marked casing 'n' capping system.
Wiring for drawing sub-main line with P.V.C insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel/Nicco/Anchor or Equivalent make as approved by the Deptt.) in surface with flat ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or Equivalent make as approved by the Deptt.) system including earth continuity. 1.9.2 With 3 x 4 sq.mm. + earth continuity with 2 x2.5 sq.mm. cable in flat 25mm ISI marked casing 'n' capping system.
1.9.3 With 3 x 6 sq.mm. + earth continuity with 2 x 4 sq.mm. cable in flat 25mm ISI marked casing 'n' capping system.
1.9.4 With 3 x 10 sq.mm. + earth continuity with 2 x 6 sq.mm. cable in flat 25mm ISI marked casing 'n' capping system.
Supplying and fitting of 18/20 Watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/pendent holder etc.as specified and directed by the deptt.
Supplying including fitting and fixing bus bar chamber (HPL/GECO/or equivalent make) with 4 strips bus bar of length 450/600/900/1000mm made of aluminium alloy or wrought aluminium suitable for 300 amp capacity complete with all accessories including connection etc. as required complete.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grounting nuts & botls as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.2.1 ABB, Schneider MG, legrand, Hager make) 15.2.1.3 8 way SPN double door
15.2.1.4 12 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.8.1 ABB, Schneider MG, legrand, Hager make) 15.8.1.2 6 way TPN (4+18) double door
Supplying with fitting and fixing single Pole 10KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.1 B Series (Schneider MG, legrand, Hager make) 16.1.1.1 6 to 32A
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.1 B Series (ABB, Schneider MG, legrand, Hager make) 16.3.1.2 40A
Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.4.1 B Series (Schneider MG, legrand, Hager make) 16.4.1.3 63A
Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (Ics=Ics, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. As specified and directed by the deptt. 16.13.1 25 KA 415V 50Hz 3P MCCB (Schneider, legrand, Siemens make) 16.13.1.3 40A
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.14.1 35/36 KA 415V 50Hz 3P MCCB (ABB(S6), Schneider, legrand, Siemens, L&T D-shine make) 16.14.1.2 250A
Supply, installation & testing of G.I earth station with perforated 40mm dia and 4.50 metre long heady duty G.I pipe with necessary 40mm dia. G.I fittings such as Socket, Tee, elbow, nipple and 50mm x 40mm G.I reducing socket for funnel including locking arrangement 300mm x 300mm x 6mm hinged cover C.I earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt.
Extra for using salt (5K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 8 SWG G.I. earth from Earth Electrode (below G.L) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying including fitting fixing of following A.C Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Department (Without regulator). 27.1.2 Premium model 1200mm Sweep (ORIENT PSPO make)/Premium model 1050/1200mm Sweep SS-390 Deco Havells make)
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Department. 27.2.1 Domestic 27.2.1.2 Power Flow 225mm sweep (ORIENT make)
Supplying with installation testing and commisioning of HI wall 3 STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with indoor and outdoor unit, copper pipe and electrical connection as approved by the Deptt.) up to 5m between the room unit and out door unit as directed by the department. 1.50 Ton Dura cool star premium.
Supplying with fitting and fixing of Single Phase Modular Motor Starter switch of the following specification complete including making necessary connection as specified and directed by the deptt. 8.65.3 Overload Relay Range 16-25 Amps in 3 Module
Supplying with fitting and fixing Voltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND/Vee-Dee/V GUARD/VERTEX/INDO/VENUS make) 31.1.7 4.0 KVA Automatic input 90-280 V out put 200-240 V
Supplying and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm. 3 x 10 sq mm, 4 x 6 sq mm balance all galvanised steel strip), extruded PVC Type ST2 sheated, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, sand cushioning etc complete handling of surplus spoil, debris at to proper place as specified and directed by the deptt. (Nicco/Havells/RPG/CCI/Polycab/Gloster/Finolex make).
32.1.1 2 Core A2XWay A2XFaY 32.1.1 4.00 Sq.mm 2 Core armoured U.G cable
32.1.4 4 Core A2XWY A2XFY 32.1.4.6 35.00 sq. mm.4 Core armoured U.G cable
32.1.4.8 70.00 Sq. 4 Core armoured U.G. cable
Supplying installation testing and commisoning of the following indoor Decorative Recess mounted LED down lighter luminaris of model no. LESP01R009XC/LESP01R009XN/LESP01R009XW/L00957R000/L00940R00/L00930R000/LD90-111-XXX-65-XX complete with all accessories such as ballastm starter etc. in the false ceiling type Armdtrong/Gypsum or similar ceiling mounting.........by the Deptt.
Supplying fitting & fixing of LED Lubik Batten tube light fitting 300mm length as required and as directed by the Deptt. (Jaquar or eqvt. Make) c) Kubik series Batten tube fitting 20 W
Supplying installation testing and commissioning of resure die casrt powder coated aluminium alloy housing forested PC diffuser IP65/IP66 protection with built LED of the following landscape luminaries (Post Top) suitable for 38mm dia post top mounting..........by the Department. a) PHILIPS POST TOP CODE NOS BGP 161 LED 2500/NW PSU 220-240V 7043 IN & BGP 161LED 2300/NW PSU 220-240-7043 IN.
Supplying installation testing and commisioning of pressure die cast powder coated aluminium alloy housing forested PC diffuser, IP65/IP66 protection of the following street light including connection with 2.5 sqmm 3 core PVC insulated rouded copper as required as directed by the Department. a) BRP409 LED CW 036 MR FG SO PDU GR
Load security paid to ASEB authority
Sanitary Installation Earthwork in excavation for foundation trenches of walls, retianing walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of ……….directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In Ordinary Soil
Providing soling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour………complete. (a) Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32 mm in foundation bed for footing steps, walls, brick works etc.as directed and specified including dewatering if necessary, and ……….easured and paid separately). (a) In prop 1cement: 3 sand: 6 coarse aggregate by volume
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary. (b) In proportion 1:4.
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (b) 20mm thick
Providing precast R.C.C slab over drain, septic tank etc. in prop. 1:2:4 reinforcement with 10mm M.S bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering curing etc.complete including fixing in position as directed. a) 100mm thick slab
Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors 1.1.3 Vitreous water closet squatting pan Indian type W.C Orissa pattern of size 580 x 450mm b) Coloured ii) Hindware make
Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high) with seat and lead, CP brass hinges and rubber buffers, CI/MS brackets, 40mm dia flush ban………..paid separately). B) Hindware make b) Coloured (vi) Water closet UNIVERSAL "S (Cat.NO.20012) (inclusive of seat cover)
Supplying, fitting and fixing automatic flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush, pipe, union clamps etc. complete as directed and specified . (ii) Hindware make b) Coloured Auto Cister 10 litre (Cat. No.C61002)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required…………..be paid separately). (B) Hindware make (a) White (ix) MINI REGAL (Cat. No.10054/11018)
Providing fitting and fixing Decorative Mirror complete as directed and specified. (B) Jaquar make (b) Swivel Mirror (Cat. No.ACN-1195N)
Providing, fitting and fixing CP soap tray/soap dish complete as directed and specified. (i) Jaquar make (a) Continental (Cat.No.ACN-1331N)
Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make (vii) Kubix (600mm long) (Cat.No.AKB-35711)
Supplying, fitting and fixing PVC pipes of 6Kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing wiyh clamps etc. as necessary complete at all levels including below G.L as directed and specified. A) In exposed surfaces or in trenches (ii) 110mm dia.
vi) 50mm dia
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. A) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fitting and fixing 45 degree PVC bend of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levles including below G.L as directed and specified. A) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fitting and fixing PVC Plain single tee of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. A) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fitting and fixing PVC single 'Y' of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. A) In exposed surfaces or in trenches. (i) 160mm dia
Providing and fixing 3 layer (Outer green/GREY coloured UV Stabilised, middle black coloured UV Stabilised and intermost layer white coloured with antimicrobial property) Fusion welded………fitting and clamping, cutting and making good to the damages. A) Exposed or in trenches SFMC/FUSION brand or other brand of equivalent quality. c) PN-16 Pipe, 25mm OD, SDR-7.4
Supplying fitting and fixing PVC cleaning pipe of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L as directed and specified. (c ) 75mm
Providing fitting & fixing C.I Grating to the floors complete as directed and specified. (a) 110mm dia
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C plain sheet above…………mentioned in the table.
Construction of inspection pit inside measurement 450mm x 450mm x 450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling,……..including supplying of materials, necessary excavation of pit as directed.
Providing fitting and fixing 450mm dia. 90mm thick C.I man hole cover and frame of 58 Kg. weight complete as directed and specified.
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader and brass unions, etc. complete including painting of fittings and ……….wherever required. (a) Parryware make (a) White (i) New Magnum (Cat.No.C0575)
Water Supply Labour for boring hole for inserting tube well pipe through different soil/rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowring pipes, fittings complete as directed by the Department.
Supplying, fitting and fixing pipes plain/level ended for casing conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes………directed by the Department. I) G.I pipe V) 125mm diameter
Supplying, fitting and fixing suction pipes plain/level ended, conforming to relevant IS codes of practice including supplying and ……….complete as directed. A) G.I pipe a) TATA/SAIL (Medium) socket should be welded to the pipes. (iv) 50mm diameter
Supplying fitting and fixing ISI approved PVC filter 3.00 metre long.
Supplying fitting and fixing check valve (non return valve) including thread to pipes. (ii) 32mm diamter
Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained.
Flushing, Clearing, washing and watering of the tube well
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex/Polycon/Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes. I) 2000 Lt capacity
Labour for erecting and placing PCVC Tank over the stagging up to a height of 5.00m complete as directed. (a) 2000 litre capacity
Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed. B) uPVC pipe with uPVC fittings (Using uPVC high pressure pipe) (Using SUPREME/PRINCE/SFMC/FUSION brand pipe). iii) 25mm diameter
i) 15mm diameter
Supplying fitting and fixing G.I Pipes of following sizes, with all necessary 'R' brand or similar approved G.I Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw, H.W. clamps etc………directed and specified. C) 32mm dia (Medium) i) Using Tata make
Supplying fitting and fixing C.P bib cock 15mm dia of approved brand directed and specified. (G.I & C.P pipes will be measured separately). II) Jaquare make iii) 2-Way bib cock
Supplying and fitting C.P pillar cock of 15mm dia of approved brand as specified and directed. II) Jaquar make (B) Long neck with areator.
BIBHUTI GOYARI
RAMEN RAMCHIARY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .