Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹80,000Qualified Make: Elak
Model: elak, battery charger 12x48v 2689 PHASE VII MOHALI PUNJAB 160055 | S A S NAGAR | PUNJAB | 160055 | Make: Elak
Model: elak, battery charger 12x48v | ₹80,000 | L1 | Qualified |
| 2 | L2₹1.6 L+₹79,984 (100.0%)Qualified Make: Elak
Model: Elak Fast Charger FC 60/24 10 NO STOP BHOPAL MADHYA PRADESH 462016 | BHOPAL | MADHYA PRADESH | 462016 | Make: Elak
Model: Elak Fast Charger FC 60/24 | ₹1.6 L+₹79,984 (100.0%) | L2 | Qualified |
| 3 | L3₹1.8 L+₹98,000 (122.5%)Qualified Make: Elak
Model: ELAK BATTERY CHARGER 6 BATTERY 4444 BEHIND AJIT NAGAR POLICE STATION AMBALA HARYANA 133001 | AMBALA | HARYANA | 133001 | Make: Elak
Model: ELAK BATTERY CHARGER 6 BATTERY 4444 | ₹1.8 L+₹98,000 (122.5%) | L3 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
7 Jul 2018, 1:00 pmClosed
battery chargers Average Turn Over of Last 3 Years 50 Lakh (s) Experience with Gov. Required 10 Year (s) Battery Chargers ( 4 ) Technical Specifications Specification Specification Name Values Allowed Values Ungrouped GENERIC Charger technology Transformer Based Transformer Based Compatibility with battery type (User Selectable) Lead acid & Tubular &VRLA- SMF Lead acid & Tubular &VRLA- SMF Number of Independent charging stations (in numbers) 1 1
3
5 CONSTRUCTIONAL Input Voltage Range (VAC) 160 volt 270 volt (ISI MARKED POWER CORD TO BE PROVIDED) - AC surge protection AC surge protection at Input side with MOV (Metal Oxide Varistor) - Soft start and Soft stop feature without inrush current Yes - Facility for charging deep discharged battery through pulse charging. yes - 1/4 Not to charge battery in case one or more cells are internally short/Battery voltage less than 10.5V Yes - Digital display of output voltage and current Yes - LED Indication for Charging Status
Charged condition status and reverse polarity Yes - Cabinet Material CRCA Sheet - Cabinet Thickness (mm) minimum 1.2 mm - Length of Charging Cable for each station. (metre) Minimum 1.5 mtrs. Length (ISI MARKED Cable) - Size of Charging Cable for each station. (sq. mm) min. 6 sq.mm as per IS:694 ISI MARKED FLEXIBLE Cu cable per station - FUNCTIONAL Battery/battery bank Voltage (Volts) 12 Volts per station - Capacity of the battery to be charged(User Selectable) (AH) 7 aH TO 120 aH - Maximum Charger output current (Amp) 12 Ampere per station - Charging Cut-off Voltage per 12V battery (Volts) 14.5 volt +/-0.2 volt - Efficiency (%) >/= 75% - Ripple (Peak to Peak at Full Load) (millivolts) <100 - Reverse Polarity Protection Yes - Short Circuit Protection Yes - Over Current Protection Yes - Over voltage cutoff protection Over voltage protection at 280 volt at input and automatic recovery at 270 volt when the voltage is reduced from 280 volt - Cut-in voltage for charging a discharged Cut-in voltage shall be 10.5 Volt - 2/4 battery (Volts) Cut-off voltage for charging a discharged battery (Volts) Cut-off voltage shall be 14.5 V +/- 0.2 Volt - Minimum operating temperature (Degree Celsius) -10 - Maximum operating temperature (Degree Celsius) +55 - CERTIFICATIONS Availability of Type Test Report from Central Government NABL/ILAC Accredited lab To prove conformity to the specification Yes - Type Test report No. ELAK24VDC60ADC - Test report date 01/01/2015 - Name of Lab ELAK TESTING LABORATORY - Address of Lab Chandigarh - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 K V G K Ranga Raju 734007
OC 532 SSTC C/O 99APO Teen Batti More Silliguri 4 15 Required No ePBG Required No
287508
GEM/2018/B/40808
battery chargers
15 days
West Bengal; Jalpaiguri
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| battery chargers Average Turn Over of Last 3 Years 50 Lakh (s) Experience with Gov. Required 10 Year (s) Battery Chargers ( 4 ) Technical Specifications Specification Specification Name Values Allowed Values Ungrouped GENERIC Charger technology Transformer Based Transformer Based Compatibility with battery type (User Selectable) Lead acid & Tubular &VRLA- SMF Lead acid & Tubular &VRLA- SMF Number of Independent charging stations (in numbers) 1 1 | - | - | - |
| 3 | - | - | - |
| 5 CONSTRUCTIONAL Input Voltage Range (VAC) 160 volt 270 volt (ISI MARKED POWER CORD TO BE PROVIDED) - AC surge protection AC surge protection at Input side with MOV (Metal Oxide Varistor) - Soft start and Soft stop feature without inrush current Yes - Facility for charging deep discharged battery through pulse charging. yes - 1/4 Not to charge battery in case one or more cells are internally short/Battery voltage less than 10.5V Yes - Digital display of output voltage and current Yes - LED Indication for Charging Status | - | - | - |
| Charged condition status and reverse polarity Yes - Cabinet Material CRCA Sheet - Cabinet Thickness (mm) minimum 1.2 mm - Length of Charging Cable for each station. (metre) Minimum 1.5 mtrs. Length (ISI MARKED Cable) - Size of Charging Cable for each station. (sq. mm) min. 6 sq.mm as per IS:694 ISI MARKED FLEXIBLE Cu cable per station - FUNCTIONAL Battery/battery bank Voltage (Volts) 12 Volts per station - Capacity of the battery to be charged(User Selectable) (AH) 7 aH TO 120 aH - Maximum Charger output current (Amp) 12 Ampere per station - Charging Cut-off Voltage per 12V battery (Volts) 14.5 volt +/-0.2 volt - Efficiency (%) >/= 75% - Ripple (Peak to Peak at Full Load) (millivolts) <100 - Reverse Polarity Protection Yes - Short Circuit Protection Yes - Over Current Protection Yes - Over voltage cutoff protection Over voltage protection at 280 volt at input and automatic recovery at 270 volt when the voltage is reduced from 280 volt - Cut-in voltage for charging a discharged Cut-in voltage shall be 10.5 Volt - 2/4 battery (Volts) Cut-off voltage for charging a discharged battery (Volts) Cut-off voltage shall be 14.5 V +/- 0.2 Volt - Minimum operating temperature (Degree Celsius) -10 - Maximum operating temperature (Degree Celsius) +55 - CERTIFICATIONS Availability of Type Test Report from Central Government NABL/ILAC Accredited lab To prove conformity to the specification Yes - Type Test report No. ELAK24VDC60ADC - Test report date 01/01/2015 - Name of Lab ELAK TESTING LABORATORY - Address of Lab Chandigarh - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 K V G K Ranga Raju 734007 | - | - | - |
| OC 532 SSTC C/O 99APO Teen Batti More Silliguri 4 15 Required No ePBG Required No | - | - | - |
Exempted
7 Jul 2018
4 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_287508.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .