Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.0 LAccepted-AOC NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | ₹48.0 L Quoted ₹49.0 L | L1 | Accepted-AOC Acceptance |
| 2 | L2₹54.3 L+₹5.3 L (10.8%)Rejected-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | ₹54.3 L+₹5.3 L (10.8%) | L2 | Rejected-AOC R |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
27 Dec 2021, 6:00 pmClosed
GE IMA Dehradun
GE IMA Dehradun
SPECIAL REPAIR FOR REPLACEMENT OF OLD LT PANEL FEEDER PILLAR BOX AND LIGHTENING CONDUCTORS PO SOLAR GEYSER AT NEW SWIMMING POOL HOSE PIPE FOR FIRE HYDRANT FOR NEW MAGZINE RACK FOR LUGGAGE ROOMS AT BHAGAT BN AND WATER TANK STAGING FOR CA BN OFFICE
2021_MES_481808_2
GE/IMA/92/2021-22 9151/E8
Open Tender
Support/Maintenance Service
Item Rate
120 days
GE IMA Dehradun
Refer NIT
9 documents required · 9 mandatory
₹500
Yes
GE IMA Dehradun
₹99,000
Yes
8 Jan 2022
6 Dec 2021
29 Dec 2021
7 Dec 2021
27 Dec 2021
13 Dec 2021
Amount
Supply, installation, commissioning and testing factory made LT panel board CPRI approved suitable for 3 phase, 4 wire, 440 Volts AC supply, indoor cubical type, dust and vermin proof powder coated, made out of 3.15 mm thick CRCA sheet with angle iron frame made out of MS angle 50 x 50 x 6 mm both side openable doors with proper locking arrangement duly powder coated of approved colour over a coat of red oxide primer all over steel surfaces with 75 cm high angle iron legs welded on four corners of frame embedded in PCC 1:2:4 using 20 mm graded stone aggregate upto 30 cm foundation and proper glanding, lugs and nuts bolts etc for all cables and comprising of following accessories including disconnecting and taking down existing panel etc complete all as directed with sufficient working space with and including to accomodate the following accessories: - Incomming (a) Aluminium bus bar 2000 Amps rating 3 phase 4 wire system. (b) Digital voltmeter 0-500 V - 01 Nos. (c) Digital ammeter 0-1600 Amps with CTs – 01 Set. (d) LED type indicator 230 volts for RYB – 01 Set. (e) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 1600 Amps - 01 Nos Outgoing (a) MCCB 415 volts, 4 pole 630 Amps with breaking capacity 50 KA-01 No. (b) MCCB 415 volts, 4 pole 400 Amps with breaking capacity 36 KA-01 Nos. (c) MCCB 415 volts, 4 pole 200 Amps with breaking capacity 36 KA – 02 Nos. (d) MCCB 415 volts, 4 pole 160 Amps with breaking capacity 36 KA – 02 Nos. (e) MCCB 415 volts, 4 pole 100 Amps with breaking capacity 16 KA – 02 Nos. (Location: Pandiwari sub stn for 1000 KVA Txr)
Supply, installation, commissioning and testing factory made LT panel board CPRI approved suitable for 3 phase, 4 wire, 440 Volts AC supply, outdoor cubical type, dust and vermin proof powder coated, made out of 3.15 mm thick CRCA sheet with angle iron frame made out of MS angle 50 x 50 x 6 mm both side openable double door type with proper locking arrangements duly powder coated of approved colour over a coat of red oxide primer all over steel surfaces with 75 cm high angle iron legs welded on four corners of frame embedded in PCC 1:2:4 using 20 mm graded stone aggregate upto 30 cm foundation and proper glanding, lugs and nuts bolts etc for all cables and comprising of following accessories including disconnecting and taking down existing panel etc complete all as directed with sufficient working space with and including to accomodate the following accessories: - Incoming (a) Aluminium bus bar 800 Amps rating 3 phase 4 wire system. (b) Digital voltmeter 0-500 V - 01 Nos. (c) Digital ammeter 0-630 Amps with CTs – 01 Set. (d) LED type indicator 230 volts for RYB – 01 Set. (e) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 630 Amps - 01 Nos Outgoing:- (a) MCCB 415 volts, 4 pole 400 Amps with breaking capacity 36 KA-02 Nos. (b) MCCB 415 volts, 4 pole 100 Amps with breaking capacity 16 KA – 02 Nos. (Location: Basantor coy, Sangroy coy and MT colony for 400 KVA Txr)
Supply, installation, commissioning and testing factory made LT panel board CPRI approved suitable for 3 phase, 4 wire, 440 Volts AC supply, outdoor cubical type, dust and vermin proof powder coated, made out of 3.15 mm thick CRCA sheet with angle iron frame made out of MS angle 50 x 50 x 6 mm both side openable double door type with proper locking arrangements duly powder coated of approved colour over a coat of red oxide primer all over steel surfaces with 75 cm high angle iron legs welded on four corners of frame embedded in PCC 1:2:4 using 20 mm graded stone aggregate upto 30 cm foundation and proper glanding, lugs and nuts bolts etc for all cables and comprising of following accessories including disconnecting and taking down existing panel etc complete all as directed with sufficient working space with and including to accomodate the following accessories: - Incoming (a) Aluminium bus bar 600 Amps rating 3 phase 4 wire system. (b) Digital voltmeter 0-500 V - 01 Nos. (c) Digital ammeter 0-400 Amps with CTs – 01 Set. (d) LED type indicator 230 volts for RYB – 01 Set. (e) MCCB 415 volts, 4 pole 400 Amps with breaking capacity 36 KA-01 Nos Outgoing (a MCCB 415 volts, 4 pole 200 Amps with breaking capacity 36 KA – 02 Nos (b) MCCB 415 volts, 4 pole 100 Amps with breaking capacity 16 KA – 02 Nos. (Location: Bunglow No. P-08 and P-18)
Supply, installation, commissioning and testing factory made LT panel board CPRI approved suitable for 3 phase, 4 wire, 440 Volts AC supply, outdoor cubical type, dust and vermin proof powder coated, made out of 3.15 mm thick CRCA sheet with angle iron frame made out of MS angle 50 x 50 x 6 mm both side openable double door type with proper locking arrangements duly powder coated of approved colour over a coat of red oxide primer all over steel surfaces with 75 cm high angle iron legs welded on four corners of frame embedded in PCC 1:2:4 using 20 mm graded stone aggregate upto 30 cm foundation and proper glanding, lugs and nuts bolts etc for all cables and comprising of following accessories including disconnecting and taking down existing panel etc complete all as directed with sufficient working space with and including to accomodate the following accessories: - Incoming (a) Aluminium bus bar 1000 Amps rating 3 phase 4 wire system. (b) Digital voltmeter 0-500 V - 01 Nos. (c) Digital ammeter 0-800 Amps with CTs – 01 Set. (d) LED type indicator 230 volts for RYB – 01 Set. (e) ACB 4 Pole, 415 volts with Thermal Magnetic Release (Manual Drawout type) of capacity 800 Amps - 01 Nos Outgoings (a) MCCB 415 volts, 4 pole 400 Amps with breaking capacity 36 KA-01 No. (b) MCCB 415 volts, 4 pole 250 Amps with breaking capacity 36 KA-01 Nos. (c) MCCB 415 volts, 4 pole 200 Amps with breaking capacity 36 KA – 02 Nos. (d) MCCB 415 volts, 4 pole 100 Amps with breaking capacity 16 KA – 02 Nos. (Location: JCOs mess for 500 KVA Txr)
Supply, installation, commissioning and testing factory made LT panel board CPRI approved suitable for 3 phase, 4 wire, 440 Volts AC supply, outdoor cubical type, dust and vermin proof powder coated, made out of 3.15 mm thick CRCA sheet with angle iron frame made out of MS angle 50 x 50 x 6 mm both side openable double door type with proper locking arrangements duly powder coated of approved colour over a coat of red oxide primer all over steel surfaces with 75 cm high angle iron legs welded on four corners of frame embedded in PCC 1:2:4 using 20 mm graded stone aggregate upto 30 cm foundation and proper glanding, lugs and nuts bolts etc for all cables and comprising of following accessories including disconnecting and taking down existing panel etc complete all as directed with sufficient working space with and including to accomodate the following accessories: - Main incoming (a) Aluminium bus bar 300 Amps rating 3 phase 4 wire system. (b) Digital voltmeter 0-500 V - 01 Nos. (c) Digital ammeter 0-200 Amps with CTs – 01 Set. (d) LED type indicator 230 volts for RYB – 01 Set. (e) On load change over switch 200 Amps 4 Pole, 415 volts - 01 Nos (f) MCCB 415 volts, 4 pole 200 Amps with breaking capacity 36 KA-02 Nos . (Location: P-11 AGR)
Supply, installation, commissioning and testing of bus bar chamber outdoor type made out of 3.15 mm CRCA sheet of size 750 mm x 450 mm x 400 mm, dust and vermin proof factory made CPRI approved both side openable double door type with proper locking arrangements with aluminum bus bar suitable fo 400 amps rating 3 phase 4 wired system weather proof complete with danger plate including MCCB 4 pole, 415 volts adustable type, 250 Amp 25 KA -01 No fixed inside the chamber mounted on angle iron frame 50 X 50 X 6 mm imbedded in PCC (1:3:6) block type C-2 using 40 mm graded stone aggregate of size 200 x 200x 300 mm including connection of cable with lugs of suitable size etc complete all as directed.
Air termination single pointed at top and properly threaded at bottom end, aluminium rod 12 mm dia and 300 mm long fixed in repairs complete all as specified and directed
Aluminium strip 25 x 3.15mm with saddles and fixing screws etc.for roof conductors and down conductors above ground fixed in repair complete all as specified and directed
Earth continuity conductor or main earthing lead GI strip 25 x 4mm,fixed to wall on batten or recesses or chasis or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated switch situation for loop earthing etc complete all as specified and directed.
25 mm dia galvanised steel tube medium grade for fixing of air termination rod including all fittings, cut in to pieces complete all as specified and directed.
Earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to GI strip 32mm X 6mm main earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron and steel protected with 40mm dia light grade GI pipe all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 40mm dia GI light grade earth lead protection pipe etc complete all as specified and directed. NOTE: (i) Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth lead & protection pipe, if any, required at site shall be measured and paid for separately under appropriate item of BOQ. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted. (a) Item S. No. 07 to 11 will be executed at building as per list attached or executed as required in other buildings. (b) The T &P and safety measure for execution of work in high rise buildings is included in the quoterd rates. (c) The lightening conductor will be fixed in the wall at 1 to 1.5 meter distance over the insulator duly fixed in wall as required with proper size clamps/rawal plugs and screws etc. (d) The earth test result should be recorded after execution of each building in the presence of user in a register and second test after completion of CA duly signed by user and register should be submit before completion of work. (e) Incase the test result will be less than 5 ohm than complete earthing will be again provided without any extra cost.
Supply, installing, testing and commissioning of 'Solar Hot Water System (over top of second floor) (Flat Plate Collector) based on indirect transfer of heat to provide 1000 ltrs/day hot water supply at 60-70°C with adequate electric backup by providing required numbers of heating elements of capacity - 3 KW, 230 Volts with thermostable head and three phase contractor in water proof enclosure for cut off upto required temperature including stainless steel SS 304 hot water exchanger tank having insulation of 100 mm thick glass wool with aluminium cladding complete all as specified and directed. Note:-Required T&P for lifting/shifting of plant is contractors own arrangement without any additional payment.
Hot water GI pipe medium grade duly insulated with glass wool and aluminium clading 25mm bore medium grade with fittings complete ISI Marked as approved by GE complete all as specified and directed.
Hot water GI pipe medium grade pipe duly insulated with glass wool and aluminium clading 50mm bore medium grade with fittings complete ISI Marked as approved by GE complete all as specified and directed.
Supply, laying,connecting & testing cable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured electric power cables (Heavy duty ) 1100 V grade with stranded aluminium conductor of size 10 Sq mm 4 core complete all as specified and directed
MCB DB, sheet metal enclosures double door TPN 4 way with 200 Amps rated bus bar 415 volts 2 in 1 shutter (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
MCCB, 63 Amps, 4 pole, 415 volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting complete all as specified and directed.
MCB SP 6 to 32 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete all as specified and directed
1000 Litres capacity rotational moulded polyethylene water storage tanks, three layered, ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including 20mm dia GI light grade washout pipe 50mm long with plug and 20mm dia GI light grade over flow pipe 600mm long with fitting with and including Ball valve 25mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball min weight 455 gms complete all as specified and directed.
25mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) complete and jointed, tested and fixed to wall and ceiling or laid in floors, complete all as specified and directed.
Supply, jointing and testing, ISI Marked, of approved quality, gun metal globe/gate valve with iron wheel head, both ends screwed for iron pipe complete all as directed for following bore of pipes gate valve complete all as specified and directed :-
50mm bore
40mm bore
25mm bore
20mm bore
Mild steel work as in frame for staging of solar water panel made of angle iron frame duly painted with two coats of synthetic enamel paint over a coat of red oxide primer to be fixed in and including PCC block 1:2:4 type B1 of size 450mmx300mmx300mm on RCC roof of building including covering of mild steel sheet 3.15mm thick work complete all as specified and directed.
PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, coping, benching, kneelers, apex stone, bed plates, kerbs, etc. including weathering, slightly rounded or chamfered angles and throating, including necessary from work etc complete all as directed.
75 mm thick PCC 1;3:6 type C-2 using 40mm graded stone aggregate as in plinth protection or similar places and finishing the surface even & smooth with out using extra cement including making joints 12mm wide to the full depth of PCC at every 3 meter and every change of direction and filling the same with mixture of bitumen & sand in ratio (1:1) by weight including necessary form work etc and, complete all as specified and directed.
PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation filling, mass concrete and sub base of floor etc complete all as specified and directed.
Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Taking down cement plaster on brick or stone walling built in CM including raking out joints hacking for key scrubbing down with water etc complete as specified
Rendering 5mm thick plaster on concrete surface in CM (1:3) on ceiling finished even and smooth without using extra cement complete all as specifiied and directed.
Rendering 15mm thick plaster on fair faces of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n. Exc 15cm thickness (below or above) ground level complete all as specified and directed.
Preparation of old plastered surfaces of walls by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of oil emulsion distemper on walls complete all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of oil bound emulsion over a coat of cement primer complete all as directed.
Preparation of new surfaces of wall / ceiling and applying two coats of cement based paint including scaffolding complete all as specified and directed.
Surface excavation n. Exc 30 Cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n' exc. 1.5 m in depth and getting out in any type soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in soil complete all as specified and directed.
Removing surplus excavated soil to a distance n.exc 50 metre & depositing where directed at a level n.exc 1.5 metre above the starting point complete all as specified and directed.
Brick work with sub class ‘B’ bricks (old size), straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Brick work with sub class B bricks, straight or curved on plan exceeding 6m mean radious built in cement mortar (1:6) complete all as specified and directed.
Rendering 15mm thick plaster on brick work or concrete surface in CM 1:6 finished fair & even complete all as specified & directed.
RCC M -25 (Design Mix) using using 20mm graded crushed stone aggregate as in slab supported on walls beams and columns in floor, roof, landing and in shelves and the like complete all as specified and directed.
Use & waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick for fair finish surface complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified & directed.
Hard core of broken stone gauge not exceeding 63mm, deposited, spread and levelled in layer not exceeding 15 cm thick watered & rammed to a true surface complete all as specified and directed.
40mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in floors and finishing the concrete even and smooth using extra cement complete all as directed.
15mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete complete all as directed.
20mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete complete all as directed.
Cuttingchases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of shelves, landing, cills, lintels etc and making good for girth of cutting exc. 10 cm and not exc 20 cm, all complete as specified and directed.
Roughening of old concrete surfaces of floor by picking, sweoing clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 kg cement per square metre complete all as specified and directed.
Prepolished machine cut kota stone slab flooring 18-20mm thick laid over 20mm thick cement sand screed CM 1:6 as base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab and rubbing and polishing all complete as directed.
Supply only non percolatig flexible fire fighting three layer Hose Pipe for fire hydrant, synthetic fibre circular woven jacketed, with NBR-PVC rubber lined & externally covering, 42 kgf/cm 2 burst pressure, 25 kgf/cm 2 proof pressure, 15 kgf/cm 2 working pressure, very low absorption of liquids such as oils, grease, acids and alkalis etc . and high resistance to abrasion & direct heat, Bearing IS:636-2018 type 3 (Covered), 63 mm x 15 mtr length duly stainless steel wire bounded to SS 304, pair of male and female parts, heavy duty instantaneous type, 63mm size, confirming to IS:903 mark complete all as specified and directed.
Flint India
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .