Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical ANUGRAHA T C 9 1775 2 PATTANIKUNNU LANE SASTHAMANGALAM TRIVANDRUM 10 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695010 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical TC 39 1295 POOJAPURA THIRUVANANTHAPURAM 695 012 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695012 | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹27.6 Cr
EMD Value
₹5 L
Closing Date
22 Apr 2026, 3:00 pmClosed
DGM (ID)
DGM (ID)
DEVELOPMENT OF ISOLATION WARDS IN GOVT. MEDICAL COLLEGE THIRUVANANTHAPURAM
2026_HITES_847801_1
HITES/IDS/GMC-TVM-IW/25/29
Open Tender
Civil Works - Buildings
Item Rate
360 days
Thiruvananthapuram
Please refer Tender documents.
8 documents required · 8 mandatory
₹23,600
₹5 L
HITES OFFICE TRIVANDRUM
9 Apr 2026
16 Mar 2026
23 Apr 2026
16 Mar 2026
22 Apr 2026
30 Mar 2026
25 Mar 2026
CIVIL WORKS
PLUMBING WORKS
ELECTRICAL WORKS
ELV WORKS
FIRE FIGHTING WORKS(Incl.Signages)
BUILDING SIGNAGES
MEDICAL GAS SYSTEM
DSR code
DSR Analysis
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below pile cap as per structural drawing, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by using hydraulic rotary drilling all complete, including chipping of pile, socketing,removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).600 MM Pile
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Single pile above 50 tonne and upto 100 tonne safe capacity Initial test (Test Load 2.5 times the Safe capacity)
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Single pile above 50 tonne and upto 100 tonne safe capacity. Routine test (Test Load 1.5 times the Safe capacity)
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer incharge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. 2. Testing agency shall submitt the design of loading platform for the approval of Engineer-in-charge. Single pile above 100 tonne and upto 150 tonne Safe capacity . Initial test (Test Load 2.5 times the Safe capacity)
Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification ; the direction of engineer -in-Charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Single pile above 100 tonne capacity and upto 150 tonne safe capacity. Routine test (Test Load 1.5 times the Safe capacity)
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil; 1.5 m to 3 m
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials All kinds of soil.;3.0m to 4.50m
Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil 4.5m to 6.00m
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soilPipes, cables etc, not exceeding 80 mm dia
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Conveying and disposing off excavated earth by mechanical transport including loading, transporting,unloading for lead up to 5 km for all lifts, complete as per directions of Engineer-in- Charge
Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and applying proshield HDPE - P system with hs proshield - SBS-1.2mm water proofing compound/element , the work shall be carried out as per below outline methodology as specified and as directed by the engineer-in-charge 1.make a circular shape on pile head using micro-concrete using a circular mould in a height of 100 mm from base PCC level 2 make hunching around the pile-head using polymer mortar and leave it for curing a day 3.apply a coat of water based bituminous primer @ 100 gms/sqm on the circular side of pile head and after curing of 2 hours, fix and stick 1.2 mm thick SBS membrane 4 extent this SBS membrane over the PCC so as to weld with up coming HDPE ps membrane 5.lay loosely 1.2 mm thick, HDPE PS membrane on the [CC floor with 75 mm overlap and stick the edges of HDPE membrane with SBS membrane wherever it extents in an overlap of 75 mm 6 extent this HDPE PS membrane (minimum 150mm) beyond the wooden/ metal shutter erected for casting pile-cap 7.after casting, de-shuttering and curing of pile-cap, fold the extended HDPE PS membrane upwards on vertical side of the pile cap (150mm) and fix it using a steel nail/screw 8.fix and stick, 1.2 mm thick SBS membrane on the vertical wall sides of pile-cap fully, after applying a primer coat of water based bituminous emulsion @ 100 gms/sqm 9 provide back-filling, compacting and pouring pcc in required level (scope of civil contractor) 10.extent the SBS membrane fix on vertical wall of pile-cap up to 150 mm on to the PCC floor which constructed for a base floor to receive the rcc raft slab 11.lay loosely 1.2 mm thick,hdpe ps membrane with 75 mm overlap on the PCC floor and stick the edges of HDPE membrane with SBS membrane wherever it extents in an overlap of 75 mm.
Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and injecting chemical emulsion for PRE-CONSTRUCTIONAL Anti termite treatment and creating a chemical barrier on top surface of plinth filling, junctions of inside walls and floors, soil along external perimetre using the chemical lmidacloprid emulsifiable (IS 6313 (part2:2013) 30.5% SC mixed with water in 1:499 ratio. The emulsion is spread at 5litre/sqm on top surface of plinth filling,at 1 litre/linear metre along the junction of wall and floor and at 2.25litres/linear metre of the plinth wall as per the specifications and directions. (Note: plinth area only shall be measured for payment)
Providing and fixing in position 12 mm thick bitumen impregnated fibre board conforming to IS: 1838, including cost of primer, sealing compound in expansion joints.
Providing and fixing sheet covering over expansion joints with iron screws as per design. Aluminium fluted strips 3.15 mm thick150 mm wide
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, etc. and removal of form for:Stairs,(excluding landings ) except spiral - staircases)
Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide
Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)
Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels,over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Excess or less cement used as per design mix is not payable or recoverable separately. In case the cement content in design mix is more than the specified minimum cement content, the contractor shall have discretion to either redesign the mix or bear the cost of extra cement. Fly ash content is considered as per GRIHA norms . Concrete of M30 grade with minimum cement content of 350 kg /cum. All works upto plinth level.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Excess or less cement used as per design mix is not payable or recoverable separately. In case the cement content in design mix is more than the specified minimum cement content, the contractor shall have discretion to either redesign the mix or bear the cost of extra cement.Fly ash content as per GRIHA norms to be considered.All work above plinth level upto floor V level. Concrete of M30 grade with minimum cement content of 350 kg /cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Excess or less cement used as per design mix is not payable or recoverable separately. In case the cement content in design mix is more than the specified minimum cement content, the contractor shall have discretion to either redesign the mix or bear the cost of extra cement.All work upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Excess or less cement used as per design mix is not payable or recoverable separately. In case the cement content in design mix is more than the specified minimum cement content, the contractor shall have discretion to either redesign the mix or bear the cost of extra cement.All work above plinth level upto floor V level. All work above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shadeArea of slab upto 0.50 sqm
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm
Granite cladding (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. 18mm thick granite of any colour and shade
Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work
Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
Providing and laying Heavy Duty Homogenous matt finish Vitrified Tiles of Size 600x600mm of thickness not less than 16mm with water absorption, less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand)providing gap of suitable spacer between the tiles with support of spacers, including grouting the joints with epoxy grout, and matching pigments etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados,laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).300 x600 mm
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles,including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge
Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles
Providing & fixing UV Stabilized Poly carbonate solid clear sheet 2mm thick WEIGHT NOT LESS THAN 1800 GM/SQM. The masking carrying instruction as to which side UV protected & the same side should be installed facing out wards.Fire retardantconfirming to IS 1443-1987,Aluminium 50mm thick leak proof fixing management system, confirming IS 733-1987 alloy 606376 EPDM rubber gaskets, Silicone sealent,cold forged fasteners to be used for fixing the polycarbonate sheeting. EPDM rubber gaskets shall be as per ASTM -D2240 ; strength ASTM-D412 as approved by the Engineer in charge.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete:Ridges plain (500-600 mm)
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screwscomplete :Gutter (600 mm over all girth)
Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting ofmain "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending
Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I.intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement : 6 coarse sand)
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1cement : 6 coarse sand sand) etc complete
Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1cement : 6 coarse sand) etc complete
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
Solid masonry using pre cast solid blocks (factory made) of size 30x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 10cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 10cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1cement : 4 fine sand)
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
Extra for plastering exterior walls of height more than 10 m from ground level forevery additional height of 3 m or part thereof.
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 13m to 16m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 16m to 19m
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 19m to 22m
Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Wall painting with PU Finish anti fungal paint of approved brand and manufacture to give an even shade including one coat of High Performance WB Primer Polymer : Two coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster including providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Providing and fixing circular / hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Supplying and fixing rolling shutters of approved make, made of required size M.S.laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).
Steel work welded in built up sections/framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete
Steel work welded in built up sections/framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 4mm thick ACP sheet in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc.complete as per architectural drawings and directions of engineer-in-charge
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass /
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With SGU Performance glass panes of 6 mm thickness.(SHGC, U-Value , VLT as per GRIHA feasilbility report.)
Providing and fixing glazing in upvc/aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item): With DGU glass panes of 6 mm glass (Low E) + 12mm Air gap + 6mm Clear Tempered glass . (SHGC, U-Value & VLT as per GRIHA feasilbility report.) . No extra payment will be paid for Aluminium Spacer & Silicone bite.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
Providing and fixing Wooden Framed lead lined window from ISO 9001-2008 certified Manufacturer to the required sizes of approved make which consists of main Frame , Lead Line Glass, Window frame , Single rebate profile of size 120 x 70mm made out of Teak Wood (Ivory Coast) . The Shutter & FrameShall be fully lead lined of min of 2 MM lead Sheet with 99% purity and as defined by AERB. Frames should be installed with anchor fasteners on a finished plastered masonry wall opening. Window will be fitted with 8mm thick lead line glass . The Lead Line as recommended by AERB/DRC. The Lead Line Glass fitted in the fixed window with the help of Wooden beading of suitable size with gasket all round, all complete as per the direction of Engineer-in-charge.
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm).
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge. Second class teak wood35 mm thick shutters
Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete:100x60x2.50 mm
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood
Providing and fixing Pre-laminated medium density fibre board IS:14587:1998 marked, with one side decorative lamination other side balancing lamination Grade-I (exterior grade) in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand (fittings to be paid separately).Pre-laminated with decorative lamination one side and other side balancing laminaion exterior Grade-I MDF Board 18mm thick confirming to IS:14587.
Finishing wood work with Melamine polish with thinner (30%) : New work (Two or more coat applied @ 2.2 ltr/10 sqm) over and including two coats of melamine sealer with thinner (30%) @ 2.2 ltr/10 sqm and wood filler wherever required all complete as per the direction of engineer in charge.
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm
Providing and fixing bright finished brass handles with screws etc. complete:125 mm
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10 x 80 mm
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing 2mm thick lead lining over inner side of the door shutter including all fixing accessories and fixtures etc complete
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mm
Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pair of handles ( best make of approved quality ) for aluminum doors including necessary cutting and making good etc. complete
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness
Providing and fixing SS knob with cylindrical lock of approved quality with necessary screws etc. complete.
Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P.laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineerin-charge.
Supply of stainless steel handle for toughened glass door, H- type of size 450 mm and 25 mm dia with satin finish of reputed make
Supply of SS corner lock for toughened glass door of 12mm thick with weight upto 200 kg
Providing and fixing of stainlees steel corner guard of height 1500 mm 50x50mm wing size, stainless steel of 304 grade with thickness of 1mm with rubber backing 1.5 mm (total thickness 2.5mm) all complete as directed by Engineer-incharge
Providing and fixing double action hydraulic heavy duty floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors , embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge
Supply and fixing of shaft lock with allen key in Aluminium doors for fire shaft, of approved Make all complete, as per the direction of Engineer-in-charge
Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and fixing 12 mm thick frameless toughened glass door shutter and fixed glass partition of approved brand and manufacture including patch fittings, and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and heavy duty floor spring etc.to be paid separately).
Providing and fixing ISI marked fire rated GI Sheet doors conforming to FD 120-UD classification of IS 3614 :2021 with fire rating of 120 minutes integrity only. The factory manufactured door frame and shutter assembly shall be made out of minimum 1.50 mm thick GI Sheet with minimum 120 g/m2 coating as per IS: 277. The Door should be finished with powder coating in standard RAL shade finish having DFT of minimum 50 microns. The door should carry a minimum 500 Hrs of salt spray test. All accessesories like hardware, vision panel, fire smoke seal etc to be supplied by Fire door manufacturer only as per the guidelines laid down in IS 3614:2021. Every door must be ISI labeled confirming to type of door & its fire rating. The offered door must carry a prior valid test evidence of 5 years from CBRI-Roorkee. No fresh testing is required within the validity of test report from CBRI Roorkee.The Door frame shall be single rebate grooved profile to accomodate 10x4mm Fire Seal, Size of Frame to be minimum 125mm x 55mm made out of minimum 1.50mm thick galvanized steel sheet. Frames shall be butt/ mitered joint and field assembeled with bolting system. The frame should also be provided with fire rated smoke seal as per IS: 3614:2021 or as per test evidence. It shall be pasted on surface and perimeter of main frame. All provisions should be mortised & provided with necessary inbuilt reinforcement to receieve appropriate hardware. Frames should be provided with back plate bracket for anchor fastner with 8-10 mm dia and minimum 80 mm long HDG fasteners, with Polyamide sleeves for installation of frame in finished plastered masonary wall opening.
Providing and mixing integral crystalline admixture for waterproofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc.. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer's specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerincharge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
Providing and fixing C.I. M.H.cover with frame 560 mm diameter C.I. cover (heavy duty)the weight the cover to be not less than 108 kg
Supplying and fixing C.I with frame for manholes:455 x 610 mm rectangular C.I cover ( light duty ) the weight of the cover to be no less than 23 kg
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design
Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.450 mm dia RCC pipes.
Providing and fixing factory made ISI marked un-insulated metal fire rated doorset assembly for all non egress application areas like shafts etc. consisting galvanized iron steel frame and single leaf shutter including necessary hardware accessories conforming to FD 120 UD classification of IS 3614 :2021 with fire rating of 120 minutes integrity. The door frame and shutter shall be made out of minimum 1.20 mm thick Gl Sheet with minimum 120 GSM Zinc coating as per IS: 277 The entire fire rated doorset assembly shall be tested in unlatched condition as per IS 17518 (Part-1): 2022. Frame: The frame shall be of minimum size 90 x 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joints (self tab/screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as per IS: 4351. The smoke seal material shall be of EPDM tested in accordance with ASTM E-84 of minimum size 10x4 mm, fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed in all four sides to masonry wall opening with CSK/Hex headed fasteners of minimum 8 mm dia size and minimum 80 mm long with 8mm dia polyamide sleeves @ 4 number at each on vertical sides (up to 2100 mm height) and 2 numbers each on top and bottom sides.
Supply and installation of a 3-tier integrated Entrance Matting System at all designated entry/exit points in consultation with the Engineer-in-Charge (EIC) as per GRIHA IAQ norms, comprising a 1.8m (6ft) Scraper zone for heavy debris, a 1.8m (6ft) Absorption zone for moisture, and a 2.4m (8ft) Finishing zone for fine particulate capture. The system shall utilize durable, UV-resistant materials (for outdoor sections) with an anti-skid backing to prevent displacement, placed in a way to avoid tripping hazards, and must be easily removable to facilitate the mandatory weekly cleaning and maintenance protocol required for green building compliance.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and rerolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Construction of granular sub-base by providing graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401;Grading-I - Plant Mix Method
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C.paver block of M-30 grade with approved color design and pattern
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 or leaner mix ( including equivalent design mix)
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
Demolishing Laterite/blockwork/brick work including plaster, manually by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.;In cement mortar
Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar
Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
PVC WEEP HOLES- Providing weep holes using 75mm dia. PVC pipes working pressure 4kg /sq.cm including cost of materials, conveyance, labour charges etc.complete.
Supply and stacking of Terminalia catapa plant of height 60-75 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge
Supply and stacking of Syzygium Cumini plant (Java plum plant ) of height 60-75 cm. in big poly bag of size 25 cm as per direction of the Engineer -in-charge.
Supply and stacking of Mangifera indica plant of height 60-75 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.
DSR CODE
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC SCH 40) pipes, having thermal stability for hot & cold water supply including all CPVC plain brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes ; fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work/external work - 65 mm nominal inner dia .Pipes (65mm CPVC SCH 40)
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
Providing and fixing gun metal non-return valve of approved quality (screwed end): 50 mm nominal boreVertical
Providing and fixing gun metal non-return valve of approved quality (screwed end): 65 mm nominal boreVertical
Providing, fixing, testing and commissioning of brass body nickel plated automatic air release valves with necessary GI Specials, thread, holdtight, brass spindle, NBR and elastomeric, stainless steel spring poly propylenic float at the top most points of water supply distribution ring main. 20 mm dia.
Supply,Installation, testing and commissioning of SWR-B soil ; waste pipe confirming to IS 13592 of 6 kg / sq.cm pressure rated including all fittings, like Bends, Tees, Elbows, Collars, junction, rodding eye, offsets, access pipes, jointing with solvent cement followed by application of leak proof adhesive like FRP paste laid on floors inside the toilets kitchen and utility to the required slope including making necessary bores in walls / foundations / concrete slab as applicable, making good the bores with CM 1:3 or cement concrete 1:2:4 as applicable, curing etc., complete- 50mm
Supply,Installation, testing and commissioning of SWR-B soil ; waste pipe confirming to IS 13592 of 6 kg / sq.cm pressure rated including all fittings, like Bends, Tees, Elbows, Collars, junction, rodding eye, offsets, access pipes, jointing with solvent cement followed by application of leak proof adhesive like FRP paste laid on floors inside the toilets kitchen and utility to the required slope including making necessary bores in walls / foundations / concrete slab as applicable, making good the bores with CM 1:3 or cement concrete 1:2:4 as applicable, curing etc., complete- 75mm
Supply,Installation, testing and commissioning of SWR-B soil waste pipe confirming to IS 13592 of 6 kg / sq.cm pressure rated including all fittings, like Bends, Tees, Elbows, Collars, junction, rodding eye, offsets, access pipes, jointing with solvent cement followed by application of leak proof adhesive like FRP paste laid on floors inside the toilets kitchen and utility to the required slope including making necessary bores in walls / foundations / concrete slab as applicable, making good the bores with CM 1:3 or cement concrete 1:2:4 as applicable, curing etc., complete- 110mm
Supply,Installation, testing and commissioning of SWR-B pipes selffit type confirming to IS 13592 including all fitting, like bends, tees, Elbows, Collars, Junctions,rodding eye, Inspection doors, Cowls, offsets access pipes jointing with rubber ring /solvent cement followed by application of leak proof adhesive fixed on wall with properly fabricated GI bracket of suitable size ,GI U Clamp with bolts ,nuts and GI washers ,complete for soil and waste water pipelines laid in shafts/ceiling 110mm
Supply, Installation, testing and commissioning of PVC-U water pipes for underground drainage line layed under the soil with required slope, confirming to IS 15329 of 8 KN/M2 Stiffness nominal with necessary specials of required size jointing with solvent followed by application leak proof adhesives of FRP paste, including haunching / covering the joints with cement concrete 1:3:6 at all the joints trenching, refilling and testing of joints etc. complete as required- 160mm
Supplying and fixing PVC Floor Trap 110mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages.
Providing and fixing toilet paper holder:C.P. Brass
Providing and fixing SS grating with rim including setting in floor with white cement mortar and making good the floor 125mm dia
Providing and fixing low flow over head shower of size 100mm dia round shape (single flow, Griha approved) capable of 6lpm @ 3 bar head flow rate or nearest flow to the head ratio) and shower arm in position.
Supply and Fixing 110mm PVC Ventilation Cowl with wired mesh in position.
Supply and Fixing 75mm PVC Ventilation Cowl with wired mesh in position.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Making Khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished with 12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand) and a coat of near cement, rounding the edges, making and finishing the outlet complete.
Supply and fixing inline rain water filter with ss304 screen with 90mm inlet and 75mm clear water outlet
Providing and fixing PVC gully trap (single) with jali, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 160x100 mm size PVC gully trap (Single).
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:150 mm dia R.C.C. Pipe
Supply,Installation, testing and commissioning of SWR-A rain water pipes self fit type confirming to IS 13592 including all fitting, like bends, tees, Elbows, Collars, Junctions,rodding eye, Inspection doors, Cowls, offsets access pipes jointing with rubber ring /solvent cement followed by application of leak proof adhesive fixed on wall with properly fabricated GI bracket of suitable size ,GI U Clamp with bolts ,nuts and GI washers ,complete for soil and waste water pipelines laid in shafts/ceiling 110mm
Providing and fixing 15cm wide, 45cm overall square PVC rain water gutter with 15cm square clamps and fixing end caps, center drops etc. at required locations using necessary fittings all complete as per the direction of engineer in charge.
Supply,Installation, testing and commissioning of SWR-A vent pipes self fit type confirming to IS 13592 including all fitting, like bends, tees, Elbows, Collars, Junctions,rodding eye, Inspection doors, Cowls, offsets access pipes jointing with rubber ring /solvent cement followed by application of leak proof adhesive fixed on wall with properly fabricated GI bracket of suitable size ,GI U Clamp with bolts ,nuts and GI washers ,complete for soil and waste water pipelines laid in shafts/ceiling 75mm
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5
Extra for depth for manholes Size 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5
Extra for depth for manholes Size 120x90 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design
Supply, installation, testing and commissioning of 5.5Kw three phase control panel for submersible pump with Frame, cover, and assembly all fittings and Includes functionality for motor or equipment start/stop control and 2P breakers, overload protection, over voltage/ under voltage protection, dry run preventer, Ingress Protection, and other safety features.
Supply, installation, testing and commissioning of 1.5Kw three phase control panel for submersible pump with Frame, cover, and assembly all fittings and Includes functionality for motor or equipment start/stop control and 2P breakers, overload protection, over voltage/ under voltage protection, dry run preventer, Ingress Protection, and other safety features.
Supply, Erection, Testing and Commissioning of vertical single stage stainless steel drainage submersible (Dewatering pump) pump with suction strainer and level switch for automatic start and stop, capable of lifting 45lpm of water against a total head of 12m with accessories such as full way wheel valve, non return valve, starter, MCB, voltmeter and ammeter, panel board etc. (1 working)
Supply and fixing of CPVC puddle pipe with flange having a length such that there is 30cm and 10cm over hang outside and inside of the tank respectively or as suggested by engineer in charge which ever is greater 25mm outer diameter
Supply and fixing of CPVC puddle pipe with flange having a length such that there is 30cm and 10cm over hang outside and inside of the tank respectively or as suggested by engineer in charge which ever is greater 65mm outer diameter
Supply and fixing of CPVC puddle pipe with flange having a length such that there is 30cm and 10cm over hang outside and inside of the tank respectively or as suggested by engineer in charge which ever is greater 50mm outer diameter
Supply, fixing, Testing & Commissioning of brass body Multi jet dry type vane wheel cold water meter of 25mm size, antimagnetic type, hermetically sealed totalizer, dry dial, straight reading type with pulse wire output, and remote digital totalizer with RS485 output along with MS panel and capable of withstanding 16bar pressure. (In KWA incoming line to domestic water sump)
Supply and fixing Woltmann type bulk water meter of 65mm size, removable mechanism type, magnetically coupled, having dry dial, hermetically sealed totaliser, retrofittable for pulse output with pulse wire and remote digital totaliser with RS485 output along with MS panel and capable of withstanding 16bar pressure. (In STP treated water & Rain water pumping main to OHT)
Supplying, fixing testing and commissioning of horizontal type manual electric storage water heater of 15L capacity
DSR No.
Wiring for circuit / submain wiring along with earth wire with the following sizes of HFFR copper conductor, single core cable in surface / recessed medium class PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Wiring for group controlled (looped) light point / fan point / exhaust fan point / call bell point (without independent switch etc) with 1.5 sqmm FRLS PVC insultated copper conductor single core cable in surface / recessed PVC conduit, and earthing the point with 1.5 sqmm FRLS PVC insultated copper conductor single core cable etc as required.
Supplying, installation, testing & commissioning of Passive Infrared (PIR) technology based occupancy sensor having high performance, non regulating programmable type, suitable for connected load upto 10 amp, for mounting height upto 2.8m and for 5 m diameter coverage area along with necessary fixing arrangement, box for surface mounting, i/c programming at site etc complete as required.
Supplying, installation, testing & commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & Off of street lights at sun set & sun rise or twilight (Auto ON, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
Supplying and fixing following way single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnection, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
12 way double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing DP sheet steel enclosure on surface / recess along with 25/32 amps 240 volts, "C" curve DP MCB complete with connections, testing and commissioining etc as required.
Supplying and fixing FP sheet steel enclosure on surface / recess along with 16/25/32 amps 415 volts, "C" curve FP MCB complete with connections, testing and commissioining etc as required.
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing open duct as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
4C x 6 sqmm
Supply, installation,testing and commisoning of LED Based LED Bulkhead with High Pressure Die Cast Aluminium Body provided with Polycarbonate cover, System Lumen Package of 600 lm and a maximum System Wattage of 10 Watts, Ingress Protection Rating of IP66 and IK Rating of IK09, Operating Voltage Range of 120-277V AC, LM 79 and LM 80 reports need to be submitted from NABL accredited lab to verify above parameters with all accessories.
DSR No.
Supplying, installation, testing & commissioning of loop powered addressable sounder / hooter cum strobe complete with enclosure for mounting on wall surface, cable termination using gland & locknut, connections etc including all accessories as required. The device shall comply NFPA/ EN54 / UL with latest amendment upto date.
Supply, installation, testing and commissioning of addressable Manual call point (Pull down type) in suitable enclosure for recess mounting, cable termination using gland and locknut, connections etc complete with all accessories as required. The device shall comply NFPA/ EN54 / UL with latest amendment upto date.
Supply, Installation,Testing and Commissioning of Fire Fighters Telephone system / console which is capable of providing annunciation and control for local and remote telephone handsets of minimum 15 users. It includes a built in display and keypad that provide an indication of phone activation as well as corresponding trouble conditions. The telephone connections can be monitored individually or as a group of multi-phone jacks. The system has to have built-in auto program feature. The console shall be provided with necessary power supply unit, battery back up for 24 hr normal operation and 2 hr during emergency condition including all accessories as required. The device shall comply NFPA/ EN54 / UL with latest amendment upto date.
Supplying, installation, testing and commissioning of Fire fighters remote handset in suitable enclosure for recess mounting with all necessary accessories complete as required.The device shall be compactable to the fire fighters telphone system and comply required standards.
Supplying, installation, testing and commissioning of Fire fighters telephone jack in suitable enclosure for recess mounting, cable termination, connections etc complete with all accessories as required. The device shall be compactable to the fire fighters telphone system and comply required standards.
Supply laying and termination of 2 Core x 1.5 Sq.mm cable, Armoured, Screened, FRLS, PVC Insulated copper cable along with all accessories. Cable shall be terminated in devices and control panel by using properly sized cable gland & locknut. Cable shall be installed on wall/slab by using GI saddles at regular interval as per the specifications.
Item Code
a)Supplying,installation,testing and commissioning of Diesel Engine driven Main Fire Pump suitable for Automatic operation and consisting of following, complete in all respect , as required :(Diesel Driven Pump) b) Horizontal type, Multi stage ,centrifugal, split Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520. C) Suitable HP ,1500rpm,water cooled with radiator,diesel engine conforming to relevant IS standard complete with auto starting mechanism 12/24 V Electric starting equipment,diesel tank, exhaust pipe extended upto 10m outside pump house duly insulated with 50 mm thick glass wool with 1 mm thick Al sheet cladding residential silencer, instruments and protection as per standard specifications, stop solenoid for Auto stop in the event of fault with audio indications, painted with post office red colour etc as required. d) M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required.e) Suitable cement concrete foundation duly plastered with Anti vibration pads2280 lpm at 70 m head
a)Supplying, installation, testing and commissioning of Electric driven Pressurisation Pump suitable for Automatic operation and consisting of following, complete in all respect , as required :(Jockey Pump) b) Horizontal type, Multi stage ,centrifugal, split casing Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520. C) Suitable HP Squirrel Cage Induction Motor, TEFC type suitable for operation on 415 V 3 phase 50 HZ AC supply with IP55 Protection for enclosure ,horizontal foot mounted type with class F insulation, conforming to IS 325. d)M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required. e) Suitable cement concrete foundation duly plastered with Anti vibration pads180 lpm at 70m Head
Supply and Laying of below sized XLPE insulated PVC sheathed Aluminum conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections etc 3.5 x 70 sq mm
Supply and Laying of below sized XLPE insulated PVC sheathed Aluminum conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections etc 3 x 16 sq mm
Supply, erection, commissioning of additional length of Exhaust Pipes with long radius bend from silencer with necessary clamps, fixtures, civil works and thermal insulation with 50 mm thick glass wool and with 1.0 mm thick aluminium sheet cladding of following adequate size including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. The horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other accessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc. as required for installation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbo charger
supplying and fixing air vessel made of 250 mm dia 8 mm thick MS sheet , 1200 mm in height with Air release valve on top and flanged connection to riser , drain arrangement with 25 mm dia Gun metal wheel valve with required accessories , pressure guage and painting with synthetic enamel paint of approved shade as required.
Providing and fixing of pressure switch in MS pipeline including connection etc as required:
Providing and fixing in position the industrial type pressure gauges with gun metal/brass valve complete as required
Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150 mm. Dia
Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 100 mm dia
Providing and fixing 25mm forged brass ball valve with forged brass ball suitable for operating pressure of not less than 16 kg / sq.cm.
Providing and fixing 50mm Dia forged brass ball valve with forged brass ball suitable for operating pressure of not less than 16 kg / sq.cm .
Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:80 mm dia
Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:100 mm dia
Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers ,gaskets conforming to IS 13095 of following sizes as required:150 mm dia
Providing and fixing of spring loaded relief valve suitable for pressure of 16 Kg/sqcm including flanges nuts ,bolt, washer etc complete as required.
Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.150mm Dia
Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.80mm dia
Providing and fixing standard firemans axe with heavy rubber handle
Supplying and fixing single headed internal hydrant valve with instantaneous Gun metal or stainless steel coupling of 63mm dia with cast iron wheel ISI marked conforming to IS 5290(Type A) with blank Gun metal or Stainless steel cap and chain as required:Single headed stainless steel
Supplying and fixing single headed external yard hydrant valve with one no: 63 mm dia instantaneous FM Gun metal or stainless steel coupling and cast iron wheel, ISI marked ISI marked conforming to IS 5290(Type A) with blank Gun metal or Stainless steel cap and chain as required:Single headed stainless steel
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. a) 20 mm nominal Internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585 b) 20 mm nominal internal dia gun metal globe valve &nozzle c) Drum and brackets for fixing the equipments on wall. d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m
Supplying and fixing 63 m dia,15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required: Stainless steel (Grade 304)
Supplying and fixing 63 mm dia gun etal short metal branch pipe ith 20 mm nominal interanal diameter size nozzle conforming to IS 903 suitable for Instantaneous connection to Interconnect hose pipe coupling as required:Stainless steel (Grade 304)
Supply, installation, testing and commissioning of weather proof hose cabinet having the size of 750x600x250mm made of 16gauge MS Sheet with full front front glass door and locking arrangements suitable to accommodate 2 nos 15m long hose pipes and 1 No. branch pipe. The cabinet shall be painted to scarlet red color outside and white inside.
Providing & fixing SS fire brigade draw-out collecting head with nut for female coupling as per IS standards complete with built-in check valves, flanged outlet, foot valve etc. complete with bolts, nuts and rubber insertions as required and as per IS standards
Supplying and fixing fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia M.S. Pipe connection conforming to IS 904 as required:4 way-150 mm dia M.S. Pipe
Supply installation testing and commissioning of ISI marked (IS:940) portable chemical fire extinguisher, water (gas pressure) type capacity 9 liters with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets.
Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:25 mm dia
Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:32 mm dia
Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:40 mm dia
Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:50 mm dia
Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:65mm dia
Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:80mm dia
Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:100mm dia
Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:150mm dia
Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:200mm dia(Wall thickness 6.3mm)
Providing and fixing of flow switch in MS pipe including connection etc as required:100 mm dia
Providing, installation ,testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel , Grade 304,sheet with3 mm dia holes with stainless steel flange.200 mm dia
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates,pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipeof required size, flanges, orifice plate, gasket etc of follwing sizes as required: 150 mm dia
Providing,fixing, testing and commissioning of 15 mm dia quatzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler
Providing,fixing, testing and commissioning of 15 mm dia quatzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Upright sprinkler
Supplying, installation, testing & commissioning of sprinkler flexiblepipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1000 mm
Providing, installation, testing and commissioning of adjustable rosette plate for 15 mm dia in white finish UL listed or FM approved complete as required:
Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle ,bronze or gun Metal seat, ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 780 of following sizes as required:200 mm dia
Supply, installation, testing and commissioning of ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket.
Supply, installation, testing and commissioning of 4kg ABC (Powder Type) Fire Extinguisher. In HP Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:1349-1993.
Supply & installation of 5 KG Modular clean agent fire extinguisher, ceiling mounting, operating sprinkler of 68 degree operating temperature, 15 bar pressure etc.
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 lite capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters in black and gold. Cost shall be inclusive of providing 3 buckets, MS stand for 3 nos of fire buckets, or , duly painted over a coat of primer.
Signage with printed IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE of 1.5cm height letters in red with white back ground.The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 mts. from finished floor near Manual call points.Auto Glo
Providing and installing in position the following type of sign boards made out of 3mm thick rigid PVC board with computer cut with texts written to recommended height in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification. Life safety related signages (EXIT DIRECTION ARROWs i.e., left ,right ,straight ,down up, Both way, MCP etc ) as per site condition. The size of the board shall be 10cm x 30 cm
Providing and installing in position the following type of sign boards made out of 3mm thick rigid PVC board with computer cut with texts written to recommended height in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification. Providing and fixing in position the signages & FIRE ORDER on 3mm thick & Opaque PVC foam board of computerized cut, PVC non reflective self adhesive vinyl painted foam board of 750mm x 450mm.
Providing and installing in position the following type of sign boards made out of 3mm thick rigid PVC board with computer cut with texts written to recommended height in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification. Providing and installing in position the Fire safety Plan to a recommended scale and at suggested locations
Providing and installing in position the following type of sign boards made out of 3mm thick rigid PVC board with computer cut with texts written to recommended height in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification. Assembly point 12"x12"
Providing and fixing of LED sign board without battery backup. Life safety related signages (EXIT and DIRECTION) as per site condition. The frame shall be minimum 18 mm thick and size of 30 cm x 3.5 cm. The glass shall be minimum 10 mm thick and size of 29 cm x 15 cm.
Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner) or floor mounted. Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:910 60 Litres (trolley mounted)
Item Code
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.
ITEM CODE
4 STOPS & 4 OPENINGS .Travel height approx 15.6 mtrs
5 STOPS & 5 OPENINGS . Travel height approx 19.5 mtrs
DSR code
Item Description
Oxygen Supply System
Oxygen Manifold (10 +10) : Supply, Installation, testing and commissioning of (10+10) Oxygen Manifold system
Emergency Oxygen manifold Supply System : Supply, Installation, testing and commissioning of (3+3) Emergency Oxygen Supply System
Oxygen Flow meter with Humidifier Bottle: Supply, installation, testing and commissioning of oxygen flow meter with humidifier bottle. As per specification
Medical Air Plant (Package Unit ) with duplex 2000 LPM with control panel including electrical control panel: Supply, Installation, testing and commissioning of Rotary Screw/scroll type Duplex Medical Air Plant (Package Unit) having a capacity of 2000LPM as per HTM 02-01/NFPA 99C standards and tender technical specification (COMPRESSOR,DRYER,PRESSURE REDUCER,RESERVOIUR,AIR FILTER)
Medical Vacuum Plant Package Duplex 2000 LPM with control panel.: Supply, Installation, testing and commissioning of Rotary Vane type Oil-lubricated Duplex Medical Vacuum Plant (Package Unit) having a capacity of 2000 LPM as per HTM 02-01/NFPA 99C standards and tender technical specification (PUMP,RESERVOIR,BACTERIAL FILTER)
Ward Vacuum Unit: Supply, installation, testing and commissiong of Ward Vacuum Unit as per specification.
Copper Pipes
108 mm OD x 1.5 mm thk
76 mm OD x 1.2 mm thk
54mm OD X 1.2mm thick
42mm OD X 1.2mm thick
35mm OD X 1.2mm thick
28mm OD X 1.2mm thick
22mm OD X 1 mm thick
15mm OD X 1 mm thick
12mm OD X 1 mm thick
Gas Outlet Points/ Terminal Units with probe: Supply,Installation, testing and commissioning of Gas outlet points for Oxygen, Medical Air 4 Bar , Vacuum, as per specification
Oxygen outlet with probe
Medical Air 4 outlet with probe
Vacuum outlet with probe
AREA VALVE BOX (WITH VALVES): Supply,Installation, testing and commissioning of Area Valve Boxes. as per specification
Valve Box - 2 Gas Service with NIST Connection
Valve Box - 3 Gas Service with NIST Connection
Master Alarm Panel
26 area alarm and 8 equipment
MEDICAL GAS ALARM PANEL (WITH VALVES): Supply, Installation, testing and commissioning of Medical Gas Alarm Panel.as per specification
Medical Gas Area Alarm for 2 services (Oxygen and MA4 bar )
Medical Gas Area Alarm for 3 services (Oxygen, MA4 bar and Vacuum)
LINE ISOLATION VALVES: Supply, Installation, testing and commissioning of Line Isolation Valves as per specification
Supply of O2 cylinders-Class D cylinders as per specification
Horizontal/ Vertical Bed Head Panel
Supply, installation, testing and commissioning of Medical gas hose assemblies as per standard followed as per specification
Project Component
Operation & Maintenance of entire system for a minimum period of 9 Years including consumables and manpower after completion of 12 months of operation.
1st year
2nd year
3rd Year
4th Year
5th Year
6th Year
7th Year
8th Year
9th Year
Project Component
CAMC for 7 years after completion of DLP
1st year
2nd year
3rd Year
4th Year
5th Year
6th Year
7th Year
Providing Comprehensive Maintainenace Contract for Medical Gas Pipeline System (MGPS) on successful completion of Warranty
1st year
2nd year
3rd Year
4th year
5th year
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.28 MB
01VolumeITVMISW.pdf
Tender Documents • 0.90 MB
02VolumeIIGCCTVMISW.pdf
Tender Documents • 1.65 MB
03VolumeIIISCCTVMISW.pdf
Tender Documents • 1.25 MB
04VolumeIVTSTVMISW.pdf
Tender Documents • 2.16 MB
01ISWDrawingspart1.rar
Tender Documents • 9.30 MB
02ISWDrawingsPart2.rar
Tender Documents • 12.21 MB
03ISWDrawingsPart3.rar
Tender Documents • 9.83 MB
04ISWDrawingsPart4.rar
Tender Documents • 7.56 MB
VolumeVBOQISO.xls
Additional Documents • 1.11 MB
Corrigendum07Isolation.pdf
PDF • 0.25 MB
Corrigendum06Isolation.pdf
PDF • 0.18 MB
Corrigendum05Isolation.pdf
PDF • 0.25 MB
Corrigendum03ISOTVPM.rar
PDF • 0.35 MB
Corrigendum04Isolation.pdf
PDF • 0.18 MB
Corrigendum02ISOTVM.rar
PDF • 35.93 MB
Corrigendum01Isolation.pdf
PDF • 1.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .