| 1 | L1₹24.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.4 L+₹3.8 L (15.4%)Rejected-AOC H1 7 8 IT PARK ROAD NO 4 IPIA KOTA RAJ 324005 | KOTA | RAJASTHAN | 324005 | L2 | Rejected-AOC L2 | |
| 3 | L3₹28.8 L+₹4.2 L (17.1%)Rejected-AOC 114 RAJEEV GANDHI NAGAR KOTA RAJ | KOTA | KOTA | RAJASTHAN | 324005 | L3 | Rejected-AOC L3 | |
| 4 | L4₹29.3 L+₹4.7 L (19.2%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹29.4 L+₹4.8 L (19.5%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
16 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Kota
HQ CWE Kota Dadwara Military Station Kota Rajasthan 324002
CWE KOTA/KOTA-50 OF 2020-21 SPECIAL REPAIR TO BLDG NOs. GTC-41/42A AND GTC-186 AT MIL STATION KOTA
2020_MES_406659_1
CWE KOTA/KOTA-50 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
KOTA
For Enlisted Contractors Class D Category a i and for unenlisted contractors meeting enlistment criteria for required Class and Category
8 documents required · 8 mandatory
₹500
GE KOTA
₹84,000
Yes
27 Jan 2021
29 Dec 2020
18 Jan 2021
29 Dec 2020
16 Jan 2021
11 Jan 2021
29 Dec 2020 - 4 Jan 2021
60 days
Amount
B/R ITEMS Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material outside of MD Land complete all as specified and directed.
Demolition of existing roof treatment /lime concrete PCC padding over RCC roof removing complete layers of bitumen under concrete /PCC Padding, sweeping the surface with wire brusses and cleaning with water to remove all loose dirt etc and removing the rubbish off out side MoD land complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level and removal all rubbish material complete all as directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in roofs, floors (other than ground floors), beams, staircase, landings, chajjas and similar suspended work complete all as specified and directed.
Demolition of stone slabs/ PCC tiles of ant description or thickness in floors, aprons & shelves of build-in almirah etc. complete all as specified and directed.
Dismantling of ceiling boards of any description & thickness including cover fillets, complete all as specified and directed.
Dismantling of wooden posts, rafter & purlins of any description, section for any position complete all as specified and directed.
Dismantling of Asbestos cement (Corrugated semi corrugated etc.) sheets in roof coverings, complete all as specified and directed.
Dismantling of timber scantlings unframed in fillets, rails, posts, rafters, purlins, etc. under 40 sq cm in section, complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5 Sqm each with shutter (without taking off shutter from the frame) and removing from site complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking off shutter from the frame) and removing from site complete all as specified and directed.
Taking down cement plaster any description, on brick or stone walls, etc. including raking out joints, hacking for key & scrubbing down with water, etc. & removing rubbish off the premises, complete all as directed.
Dismantling of 100mm Bore Cast Iron drain pipe alongwith fittings and accessories jointed in cement mortor and taking out from wall , floors or from trenched, if rquired complete all as specified and as directed.( Note for serial item No 8 & 9 :- the length shall be measured alomg the centre line including fittings and accesories)
Hacking out old broken glass ( any thickness, size, quality or description ) from metal frame including punching or drilling out old glazing pins or spring clips and providing and fixing new clips or pins, all as specified.
Taking down shutter of any description exc. 1 sqm but n.exc 2 sqm each and removing from site complete all as specified and directed. .
Taking down wall panneling and similar work complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting any guage , thickness including Nanital or similar pattern roof coverings.
Taking up or down steel tubing and connections including cleaning for refixing or removal complete all as specified and directed:-
15mm bore.
20mm bore.
Dismantling of cement concrete tiles in floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description complete all as specified and directed.
Dismantling water tank of capacity exceeding 500Ltrs but not exceeding 1000 Ltrs and removal from site complete all as specified and directed.
Dismantling water tank of capacity exceeding 250Ltrs but not exceeding 500 Ltrs and removal from site complete all as specified and directed.
Dismantling of stone sett paving of any description or thickness laid dry and pointed, complete all as specified and directed.
S & F Roof trusses (Framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. in Fe 290 Gde E165 etc. complete all as specified and directed.
S &F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed.
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for brick work with FLY ASH BRICKS straight or curved on plan to any radius , built in CM 1:4 as in half brick wall complete, all as specified & directed.
S&F for welded steel wire fabric (weight per Square metre n. exc. 4 Kg) to steel members complete all as specified an as directed.
S&F mild steel work in tubular trusses, purlins including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 including notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts including rivets or nuts and bolts, providing and fixing cleats, fish plates, gusset plates etc and also for wedging, plumbing, turning up & fixing complete all as specified and directed.
S & F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with L type or J type hook bolts & washers etc. complete all as specified and directed.
S & F 0.50mm thick pre-painted galvalume aluminium zink coating GI based plain steel sheet of any colour as approved of 550 Mpa tensil strength as in ridge, valley gutter, weather (Length and girth as fixed) with grade of zinc 275gms omplete all as specified and directed.
S & F 35mm thick factory made IInd Class Hard wood (Hollock) plain framed, panelled door shutters single panel with lock rail and panel of 9mm B.W.P. marine grade plywood bonded with high quality liquid phenol formaldehyde synthetic resin adhesive conforming to IS-710 or 12mm thick particle board veneered with commercial veneering on both faces. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed.
S & F 35mm thick factory made glazed and skeleton door shutters open rebated of second class hard wood rail and styles(Hollock), prepared to receive glass/gauge etc without sash bars, edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed. Note :- S & F Glass/gauge shall be measured and paid for separately
S & F in repair prelaminated particle board 19/20mm thick, interior grade, ISI marked as in cupboard shutter/shelves, prelaminated one side with decorative choice lamination and other side balancing white lamination including lipping of exposed edges with polished teakwood beads, complete all as specified and directed.
Supply fabrication and fixing powder coated (Thickness of powder coating not less than 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleats for fixing etc complete all as specified and directed
Supply fabrication and fixing powder coated (Thickness of powder coating not less than 50 micron) aluminium windows and ventilator shutters, side hung type without sash bars, aluminium section weighing 0.55 Kg/RM including necessary jointing cleats, glazing clips, rubber neoprene packing, powder coated anodised aluminium snap beading, screws, powder coated anodised aluminium fittings such as peg stays 150mm long (01 No. for each leaf), Butt hinges type B-21 100mm size (02 Nos for each leaf) & handle (01 No for each leaf) etc complete all as specified and directed. (Note :- Glazing/wire mesh shall be measured and paid separately under respective items of Schedule).
S&F 3.00mm thick sheet glass n exc. 0.50 sqm, ordinary quality and glazing in oil putty in square, complete all as specified and directed.
S&F 5.5mm thick sheet glass n exc. 0.50 sqm, ordinary quality and glazing in oil putty in square, complete all as specified and directed.
S&F 3mm thick figured glass n exc. 0.50 sqm, ordinary quality and glazing in oil putty in square, complete all as specified and directed.
S & F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanized wire staples to wooden frames with beading, complete all as specified and directed.
S & F in repair galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanized wire staples to wooden frames with beading, complete all as specified and directed.
M & L for factory made steel windows conforming to IS-1038 with side hung shutters including box type hinges with 2 Nos MS 100mm size tower bolt over MS flat iron for each openable leaf & Z section handle and steel peg stay complete with glazing bars, dovetailed or welded including one shop coat of Red Oxide Zinc chromate primer complete all as specified and directed. Note :- (i) Window size and pattern wherever required and directed shall be suitable for installing Desert cooler. (ii) Wire mesh shall be measured and paid for separately).
M & L for factory made steel windows conforming to IS-1038 with side hung shutters including box type hinges with 2 Nos MS 100mm size tower bolt over MS flat iron for each openable leaf & Z section handle and steel peg stay complete without glazing bars, dovetailed or welded including one shop coat of Red Oxide Zinc chromate primer complete all as specified and directed. Note :- (i) Window size and pattern wherever required and directed shall be suitable for installing Desert cooler. (ii) Wire mesh shall be measured and paid for separately).
S&F for steel ventilators, top hung type with glazing bars complete welded including one shop coat of Red Oxide Zinc chromate primer complete all as specified and directed. Note :- Glass shall be measured and paid for separetely.
M&L preparation new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over and including one coat of pink primer complete all as specified and directed.
M&L preparation new or previously untreated steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chorme primer complete all as specified and directed.
M&L preparation old or previously untreated steel surfaces of any description not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L preparation of steel surfaces of any description n exc. 10 cm width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L preparation old or previously untreated wooden surfaces of any description not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall and applying two coats of exterior emulsion paint over a coat of primer complete all as specified and directed. Make:- Apex Ultima of Asian, weather shield MAX of ICI/Dulux. Note:- Paint and primer shall be of same make
M&L for preparation newly plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted over over a thin layer of Birla white putty complete all as specified and directed.
M & L for brushing neat cement slurry with 3.0 Kg of cement per sq. metre of surface area complete all as directed.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash on ceiling complete all as specified and directed.
M & L for preparation of old decorated wall surfaces by scrapping (any No of layers), rubbing down, washing etc. and apply two coats of oil bound distemper white or tinted complete all as specified and directed.
M & L for preparation of a uniform layer of wall care putty not less than 1.00mm thick complete all as specified and directed.
M & L for preparation of newly plastered and applying two coats of cement base paint over chalk whiting primer complete all as specified and directed.
M & L for preparation of old wal surfaces by scrapping (any No of laters), rubbing down, washing etc and apply two coats of cement based paint over a coat of primer complete all as specified and directed.
M & L for complete removal of existing treatment on old decoarated wall surfaces and applying two coats of cement base paint including necessry preparation of surfaces complete all as specified and directed.
M & L for complete removal of existing treatment on old decoarated wall surfaces and applying three coats of white wash including necessry preparation of surfaces complete all as specified and directed.
M & L for preparation of new plaster ceiling surfaces etc. and applying three coats of white washing complete all as specified and directed.
S&F 2nd class Hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, and fixed with long MS screws including two coats of polishing etc complete all as directed and as specified.
S & F in repair steel rolling shutters of 1mm thick lath, without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete gear operated type with bevel gear box and crank handle, complete all as specified and directed.
M & L Running welding in repairs of metal n exc. 6mm thick etc. complete all as specified and directed.
M & L Welding in repairs n exc. 2.5 cm in legth metal n, exc 6 mm thick etc. complete all as specified and directed.
S & F 200mm size stainless steel barrel tower bolts, compelte all as specified and directed.
S & F 150mm size stainless steel handles, fabricated fancy type compelte all as specified and directed.
S & F in repairs Soap Dish (Oval) type mild steel chromium plated of size as sample kept in sample room complete all as specified and directed.
S & F for PVC (SWR) floor trap, 75mm dia plain with grating including jointing with solvent cement to waste pipe fixed in cement concrete 1:2:4 type B1 etc. complete all as specified and directed.
S & F in repair curtain rails 25mm dia, decorative type, anodised aluminium alloy powder coated with either side fixing brackets fancy type complete all as specified and directed.
S & F 100mm mild steel butt hinges , extruded aluminium alloy with galvanised mild steel hinges pin, anodised and fixed, type B-21 complete all as specified and as directed.
S & F 300mm size ordinary mild steel, rat tailed rod pattern spring incluidng roller and roller plate welded to mild steel frame complete all as specified and directed.
M & L for 75mm thick PCC 1:3:6 , type C-1 using 20 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 2 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed.
M&L screed bed or bedding layer of mortar, 10 mm thick, in cement mortar 1:3, over RCC roof slabs for laying water proofing treatment mixed with using water proofing liquid @ 150 ml per bag of cement complete all as directed. (Note : Water proofing liquid shall be measured and paid separately)
Supply only integral water proofing liquid of Dr Fixit/Sika/Fosroc complete all as specified and directed.
Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd or Hydro Stop manufactured by TIKITAR DANOSA (INDIA) Pvt Ltd as approved by GE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over compatible bitumen primer (Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd} at the rate of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions complete all as directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen (v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 150 ml/Sqm. (vi) Above aspects are deemed to be included in quoted rate.
M & L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F aluminium grills with powder coated for window/ventilator solid mesh type not less than 3 kg per sqm area (approved pattern) edging with solid 'C' channel and fixing in position complete all as specified and directed.
M & L for TMT bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M & L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in roof curb or coping etc. complete all as specified and directed.
M & L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in sub base complete all as specified and directed.
M & L for 100mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed.
M & L for 75mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for laying 60mm thickness machine pressed precast concrete glazed coloured interlocking paver block with any shape and size confirming to IS 15658-2006 M-35 grade grey cement and pigment over and including 25mm thick sand cushioning complete all as specified & directed.
M&L 18-20 mm thick machine cut Kota stone slab flooring over and including 10 mm cement screed base laid in CM 1:4 and jointed with grey cement slurry as in floors, with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
M&L for cutting /grinding of existing marble/kota stone flooring by mechinical process using carborundum stone of appropriate grit , cleaning and finally get mirror finishedand also applying wax polish complete all as directed.
S & F High pressure steam cured (HPSC) now asbestos fibre cement building board 4mm thick in flase ceiling with GI frame work for ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips cross the intermediate channel at 457mm centre to centre including 2mm dia GI hanging wire and all hanger fittings etc. and aplying three coats of white wash on exposed surfaces of ceiling, complete all as specified and directed.
M & L for Cehquered cement concrete designed tiles, glossy finish 25cm x 25cmx25mm thick in floors over and including 15mm thick screed bed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the tile, complete all as specified and directed.
M & L for cutting and polishing (Mirror polish with waxing) of existing Kota Stone flooring in any floor first or second, complete all as specified and directed.
M & L for rubbing and polishing of existing Kota Stone Flooring to achieved finished and smooth surface etc. complete all as specified and directed.
M & L for screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:6, for laying floor finishes/tiles complete all as specified and directed.
M & L for use and waste of form work to soffits of suspended slabs such as roof slab n. exc 200mm thick complete all as specified and directed.
M & L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in vertical surfaces such as skirting or dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed.
M & L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed.
M&L 300x250x7/ 450x350x7 mm thick glazed ceramic coloured tiles as in vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles complete all as directed.
M&L rendering 15 mm thick in CM 1:6 on ceiling surfaces over Dubbing out cement plaster 5mm thick in CM 1:4 including cleaning the existing surface with water & brush complete finish the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L rendering 5 mm thick in CM 1:3 on ceiling surfaces over Dubbing out cement plaster 5mm thick in CM 1:4 including cleaning the existing surface with water & brush complete finish the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15 mm thick in CM 1:4 on stone masonry surfaces or on other than fair faces of stone masonry finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15 mm thick in CM 1:6 on brick masonry surfaces or on other than fair faces of brick masonry finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15 mm thick in CM 1:6 on stone masonry surfaces or on other than fair faces of stone masonry finished even and smooth without using extra cement complete all as specified and directed.
M & L rednering 10mm thick in CM 1:4 on brick masonry surfaces or on fair faces of brick work masonry finished even complete all as specified and directed.
S&F steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed. for the following sizes:-
15mm bore.
20mm bore.
Refixing steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed. for the following sizes:-
15mm bore.
20mm bore.
M & L for RCC (1:1.5:3) using 20mm grade stone aggregate as in slabs complete all as specified and directed.
S & F in repairs 15mm bore bib tap cast copper alloy chromium plated, fancy type screwed down high pressure long shank and cup concealed type with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.
S & F in repairs 20 mm bore dia stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.
S & F 500 litres, rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top), hoisted and fixed in position complete all as specified and directed. Note : PVC tanks shall be ISI marked and having two layers.
S & F 1000 litres, rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top), hoisted and fixed in position complete all as specified and directed. Note : PVC tanks shall be ISI marked and having two layers.
S & F 20mm bore ball brass valve high pressure with polythene float and fly nut complete, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed for following sizes:-
S & F in repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed for following sizes:-
75mm bore.
100mm bore.
S & F 110mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F PVC (SWR) junction single, (single T) equal or unequal with oval access door complete all as specified and directed of following sizes:-
75mm bore.
100mm bore.
M&L for PCC (1:2:4) type B-0 using 12.5mm graded stone aggregatelaid over roof slab after applying cement slurry for filling undulation finished even and smooth without using extra cement all as specified
E/M PORTION Taking down the existing old unserviceable point wiring of any description for old light/fan/socket/power including terminal boards, switches, sockets, ceiling roses light fitting etc and making good disturbed surfaces of walls, ceiling etc complete all as specified and directed.
Taking down the existing unserviceable MCB, DBs SPN with MCBs any type after disconnecting incoming and outgoing connections, complete all as specified and directed.
Taking down sub main wiring of any sizes, complete all as specified and directed.
Taking down carefully old ceiling fan/exhaust fan and refixing the same after repair complete all as specified
M & L for point wiring complete with 1.5 Sqmm single core unsheathed stranded copper conductor cable of 1100 volts grade PVC insulated and unsheathed FRLS cable enclosed in and including PVC casing and capping not less than 20mm width with MS sheet metal sunken switch/terminal box 1.2mm thick and phenolic laminated sheet cover 3.0mm thick and brass screws with cup washers with all necessary wall cutting and making good distrubted surface as directed, including all necessay wall cutting and making good disturbed surface including 1.5 Sq.mm solid copper conductor with green PVC FRLS insulated unsheathed earth continuity conductor to common earth & connecting to earth dolly for the following :-
One light/fan/bell point controlled by one, one way switch.
One 3 pin 5 Amps socket outlet point on the same board.
Switch socket combination 5 Amps, 3 pins points on independent board.
M & L for point wiring complete for 15 Amps socket outlet on independent board with with 2.5 Sqmm single core unsheathed stranded copper conductor cable of 1100 volts grade PVC insulated and unsheathed FRLS cable enclosed in and including PVC casing and capping not less than 20mm width with MS sheet metal sunken switch/terminal box 1.2mm thick and phenolic laminated sheet cover 3.0mm thick and brass screws with cup washers with all necessary wall cutting and making good distrubted surface as directed, including all necessay wall cutting and making good disturbed surface including 2.5 Sq.mm solid copper conductor with green PVC FRLS insulated unsheathed earth continuity conductor cable to common earth & connecting to earth dolly.
M & L switch piano flush type 5 Amps, single pole, one way, 240 Volts complete all as specified and directed.
S&F, switch socket combination, 5 Amps 240 volt 3 pin flush type universal complete all as specified and directed.
S&F, switch socket combination, 5/15 Amps 240 volt 3/5 pin flush type universal complete all as specified and directed.
S & F socket 3 pin, 5 Amps, 240 V flush type complete all as specified and directed.
S & F lamp holder, PVC / polycarbonate type with back plate suitable for Batten fittings complete all as specified and directed.
S & F ceiling rose, surface bakelite 65x50mm three terminal, PVC / poly carbonate isolated body, complete all as specified and directed.
S & F electronic fan regulator, stepper type, flush tpye, 200W on the existing phenolic laminated sheed complete all as specifed and directed.
S & F in repairs of Bell Push, flush type 5 Amps complete all as specifed and directed.
S & F in repairs of Electronic Call Bell 230 volts, single pole AC complete all as specifed and directed.
Supply and fix surface and wall mounted batten LED tube light fitting 1x20watt (4 feet long), extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with standard fittings like lamp holder etc pre-wired including including LED tube and connecting the fitting from ceiling rose/connector using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed. {Make : Cat Part No LHEWEBP6INIW020 (Endura Linear Neo) of make Havells or equivalent model of make listed in Appendix 'D' to Particular Specifation}.
Supply and fixing IP-65 rated LED building security light luminary 45 watts AC operation suitable for mounting on GI bracket of 40 mm bore, pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening, separate driver compartment with impact resistance of IK07including mounting bracket fabricated from 40mm dia GI pipe medium grade (upto 1.0 mtr long) with MS clamps nuts bolts of suitable size complete all as directed. {Model/Make :- Product Description 45W5700K Cat Part No. LHETBXU7PA6S020 of make Havells (ENDURA PEARL) or equivalent model of make Philiphs/Crompton/WIPRO/Bajaj ).
S & F sheet metal enclosure double door DB SPN 8 way, 240 volts protection class IP-43 made out of CRCA mild steel sheet surface with epoxy powder coated surface confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity all as specified and directed.
S & F sheet metal single door DB TPN 4 way, 415 volts protection class IP-43 made out of CRCA mild steel sheet surface with epoxy powder coated surface confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity all as specified and directed.
S & F MCB TPN 63 Amps, 415 volts, B-curve rupturing capacity 10 KA conforming to IS-8828-1996, IEC-60898, complete all as specified and directed.
S & F MCB SPN 6-40 Amps, 240 volts, AC supply with over load and short circuit protection and rupturing capacity not less than 10KA including making connection complete, all as specified & directed.
S & F MCB SP 6-32 Amps, 240 volts, AC supply with over load and short circuit protection and rupturing capacity not less than 10KA including making connection complete, all as specified & directed.
S & F of 40mm GI Pipe on wall, light grade for protection of LT cable, complete all as specified and directed.
M&L for sub main wiring with 2 runs of PVC insulated multistrand, copper conductor cable of size 6 Sqmm along with one run of 6 sqmm PVC insulated cable multi stranded copper conductor as earth wire in and including PVC casing & capping /rigid PVC conduit of suitable size on surface, wall/ceiling, complete all as specified and directed.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth & getting out soft/loose soil , for laying of cables, foundations of poles, struts, stays etc. and getting out including triming and forming bottom surface complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in soft / loose soil in trenches complete all as specified and directed.
Removing excavated surplus material (Soils) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M & L for brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection, complete, all as specified & directed.
M & L for sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
S&F LT UG cable and Supply/Lying / fixing, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE insulated & PVC sheathed cable heavy duty armoured, with multistranded aluminium conductor laid in trenches/ ducts/ pipes/fixed on walls/poles of size 35 Sqmm 3.5 Core complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6.3 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized iron strip 25x4mm earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 50mm bore for protection of strip and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:3:6 type C1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 3 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing complete all as specified and directed. Note :- (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (ii) The cost of excavation, earth work is included in the quoted rate.
Aditya Enterprises
ANNAPURNA ENTERPRISES
L P Singh and Co.
SINGH ENTERPRISES
Ganesh Contruction
S.S Enterprises
RAHUL ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .