Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-AOC | L1 | Accepted-AOC Work order issued | |
| 2 | L2₹1.1 L+₹343.04 (0.30%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹1.1 L+₹1,109.17 (0.98%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹1.1 L
EMD Value
₹2,287
Closing Date
16 Jun 2026, 12:00 pmClosed
Assistant Engineer, PWD
Baruipur Electrical Sub-Division, PWD
Modification and Alteration of XRay rooms at Joynagar Kultali RH Kultali block in the district of South 24 Parganas Electrical Works.
2026_WBPWD_5015119_1
WBPWD/AE/BESD/eNIT01/2026-27
Open Tender
ELECTRICAL WORKS ORG
Percentage
Joynagar Kultali RH
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,287
7 Aug 2026
8 Jun 2026
18 Jun 2026
12 Jun 2026
16 Jun 2026
12 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling the existing internal wiring incl. taken down the existing Tube light fittings, Ceiling Fans etc. by Co's own tools & tackles as per direction of E.I.C.& deposit to the section store. | 1 | Job | 381.38 | ₹381.38 |
| 2 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43
protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
4 way - 1 no. 415 V, 63 A. FP MCCB (Incoming) & 3 nos. 415 V, 32 A TP MCBs, 3 nos. 240 V, 6-32 A SP MCBs as required(Outgoing) (Legrand/ Siemens/ L&T/ABB). | 1 | Set | 15,343.23 | ₹15,343.23 |
| 3 | Supplying and fixing 4way double door sheet steel (16SWG), powder coated cable end box for TPN DB vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment-4 Way | 2 | Each | 1,302.64 | ₹2,605.28 |
| 4Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (L&T/ Siemens). | |||||
| 4.01 | 32 A | 1 | Each | 3,847.13 | ₹3,847.13 |
| 4.02 | 63 A | 1 | Each | 5,023.44 | ₹5,023.44 |
| 5Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Legrand/ Siemens/ L&T/ABB). | |||||
| 5.01 | 2+10 way Enclosure - 1 no. 240 V, 25 A DPMCB Isolator & 10 nos. 240 V, 6-16 A SPMCBs as required. | 1 | Set | 4,115.29 | ₹4,115.29 |
| 6Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] | |||||
| 6.01 | Average run 8 mtr | 16 | Point | 1,206.1 | ₹19,297.6 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.17 MB
WBF2911.pdf
Tender Documents • 0.56 MB
BOQ_5083706.xls
BOQ • 0.43 MB
dtCorrigendum.pdf
PDF • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .