Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC MOTHER TERESA ROAD ZOO TINIALI GUWAHATI 781024 | GUWAHATI | KAMRUP METRO | ASSAM | 781024 | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.4 L+₹99,840 (11.8%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹9.6 L+₹1.2 L (13.9%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Admitted, as not enlisted in required category of works |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
27 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF Kumbhirgram
AGE I AF Kumbhirgram Military Engineer Services PO Kumbhirgram Assam Pin 788109 Tele 03841282376
REPAIR REPLACEMENT MAINT OF COOLING APPLIANCES AND ALLIED WORKS AT AF STATION KUMBHIRGRAM
2023_MES_601601_1
8488/2023-24/E8
Open Tender
Civil Works
Item Rate
180 days
AF STATION KUMBHIRGRAM
As per NIT
8 documents required · 8 mandatory
₹500
Yes
AGE I AF Kumbhirgram
₹17,000
Yes
15 Sept 2023
7 Jun 2023
29 Jun 2023
7 Jun 2023
27 Jun 2023
13 Jun 2023
Amount
Dismantling of AC ( Window / Split type), Refrigerator, water coolers of any capacity & 'make', opening up for servicing, inspection / examination for serviceability of compressor, fan, motor, relay, overload protectors, capacitors, cleaning the evaporator and condenser with compressed air/ water as required, lubrication of moveable parts, replacement of worn out bolts , screws, rubber gaskets, seals, terminal & link clips, unserviceable wiring, rubber mounting for compressor including all minor spare parts for carrying out servicing including reassembling & testing of AC, Refrigerator complete all as directed. Note :- 1. During servicing work, if any major fault is observed, the machine will be repaired under respective item of the schedule under Supply and fix in repair work, and thereafter servicing will be undertaken and completed. 2. Spares required for repair of unserviceable machines if any will be measured and paid under respective item of this schedule as "Supplied only" items. However, for servicing work, cost of minor spares to be replaced if any and not specified in this schedule viz. screws, washers, teflon seal, rubber bush, insulation tape, copper thimble, copper connecting jack, short length connecting wire, markers etc upto Rs 100 is deem to be included in the rate of the item. 3. Cost of taking down, reinstallation and transportation if required for the servicing / repair work is deem to be included in the price. 4. Servicing and repair work will be carried out within the contract period as and when required as per the site requirement and as directed by Engg-in-Charge
Supply and replacement of hermetically sealed Rotary / reciprocating type compressor of 1.5 TR capacity for window type/split type AC of existing make and model with new compressors and assembling testing the same with replacement of necessary drier and capillary tube complete all as directed by Engineer-in-Charge including taking down.
All as per item No-2 here in before but 2.0 TR Window/Split type Room Air Conditioner compressor including taking down.
Repair to worn out body of windo type AC/ Out door unit of Split type AC of any make & capacity by replacing worn out portion by providing new CRCA flat sheet / MS angle or strip of appropriate gauge as per existing and fabricated to the shape as required including necessary welding, filling of putty, grinding to make the jointed surface even and apply two coats of synthetic paint over one coat of red oxide all as directed and specified including taking down.
Taking out blower motor of Window type AC of 1.5/2.0 TR capacity from its existing base and dismantling the same and rewinding the burnt out winding with super enameled copper conductor with existing gauge and size of conductor and varnishing all insulating materials including making necessary heat treatment complete all as directed by Engineer-in-charge.
All as per above item No- 5 but of condensing fan motor of split type AC of 1.5/2.0 TR capacity.
Supply and replacement of unserviceable blower motor of Windo type AC/condensing motor of Split type AC with new motor suitable for WTAC/STAC of 1.5 TR capacity including taking down old one.
Supply and replacement of unserviceable blower motor of indoor unit of split AC with new blower motor of split type AC including taking down old one.
Repair of voltage stabilizer of any capacity up to 5 KVA and make, opening up for inspection/checking serviceability of voltage regulating transformer relays, circuit board, voltmeters, incoming/outgoing connections etc and reassembling the same with dismantled component after replacement of burnt spare parts and internal wiring complete all as directed and specified by Engineer-in-Charge. Note. Spare parts shall be measured and paid separately as supply only here in below :-
Supply only transformer of any capacity up to 5 KVA .
Supply only square/ round type voltmeter of size 2" x 2" for various voltage stabilizers.
Supply only transformer relay for various capacity of stabilizers.
Supply only circuit board for various capacity of stabilizer.
Supply only 3 way connector for voltage stabilizer.
M&L for dismantling of Window type AC of 1.5 / 2.0 TR capacity and painting externally with one coat of synthetic enamel paint of existing shade of approved make after cleaning the surfaces and refixing, testing complete all as directed by Engineer-in-Charge.
Supply and charging of Refrigerant gas for Window type/ Split type AC /Refrigerator / Deep freezer of various capacity after leak test.
Supply only capacitor 230/440 VAC, 50 Hz, 2.5 MFD,+ 5% capacity suitable for all split / wiondow type Air conditioners.
Supply only capacitor 230/440 VAC, 50 Hz, 3 MFD,+ 5% capacity suitable for all split / wiondow type Air conditioners.
Supply only capacitor 230/440 VAC, 50 Hz, 4 MFD,+ 5% capacity suitable for all split / wiondow type Air conditioners.
Supply only capacitor 230/440 VAC, 50 Hz, 6 MFD,+ 5% capacity suitable for all split / wiondow type Air conditioners.
Supply only capacitor 230/440 VAC, 50 Hz, 36 MFD,+ 5% capacity suitable for all split / wiondow type Air conditioners.
Supply only capacitor 230/440 VAC, 50 Hz, 45 MFD,+ 5% capacity suitable for all split / wiondow type Air conditioners.
Supply only capacitor 230/440 VAC, 50 Hz, 55 MFD,+ 5% capacity suitable for all split / wiondow type Air conditioners.
Supply and replacement of printed circuit board (PCB) with display board,sensor and remote control for Windo type AC / indoor units of Split type AC of 1.5 TR capacity all as per existing type and make including taking down. (Make of existing AC : LG ,Voltas , videocon , Sidwal).
S&F in replacement of printed circuit board (PCB) of indoor or outdoor unit for Split inverter type AC of 1.5 / 02 TR capacity with display board, sensor and remote control including taking down all as per existing type.(Make of existing AC : voltas,LLoyd
Repair of printed circuit board (PCB) of WTAC/Split type AC of 1.5/02 TR capacity with display board, sensor and remote control all as per directed
Repair of Fin and Tubes type air cooled condenser Unit of Window / Split AC of capacity 1.5/2.0 TR all as per directed.
S&F in replacement of fan blade assembly made of aluminium alloy complete for out door unit of split type AC all as per directed.
S&F in replacement of PVC fan blade suitable for water cooler of any capacity and size all as per directed.
S&F in replacement of PVC fan blade suitable for any make of window type air conditioners of cap 1 TR to 2 TR as required and directed.
S&F in replacement of PVC blower suitable for any make of window type air conditioners of cap 1 TR to 2 TR as required and directed.
S&F in replacement of Thermostat of 20 Amps capacity for 1.5/2.0 TR WTAC compressor including knob for thermostat.
Supply and replacement of metal clad plug top 3 pin all as specified and directed.
Supply and fix in repair 3 Core 2.5 Sqmm multistrand copper conductor PVC insulated sheathed flexible cable suitable for AC / water cooler / Refrigerator / AC / Voltage stabilizer.
Supply only Nitrile Foam Insulation for copper tube of size 1/2 inch suitable for split AC including provision of requisite PVC fasteners along with insulating tape.
All as per item No 36 above but of dia 1/4" suitable for discharge/liquid line of Split type AC.
S&F in replacement of PVC flexible Drain pipe of dia suitable for Split type AC including hose clamp and taking down old deterioted pipe and burried in ground.
S&F of insulation tape for wraping on nitrial fome to make air insulated complete all as specified and directed.
S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amp all complete as specified.
M&L for sub main wiring with 2 run of single core 2.5 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor cable drawn through and including PVC Conduit/ casing capping alongwith accessories on roof/walls/ ceiling etc including one run of 2.5 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor as earth wire, including taking down old wiring, complete all as specified and directed. Note :- Two run of 2.5 Sqmm single core cable, one run of 2.5 Sqmm earth wire and one run of PVC conduit/ casing capping shall be measured as one run length.
Supply and fixing of copper pipe of size 1/2" dia complete all as directed.
Supply and fixing of copper pipe of size 1/4" dia complete all as directed.
S & F DBOXx plug and socket all in one device that provide protection to electric shock and overload and short circuit current of 20 A all complete as specified. Make : Havells/Legrand/Indoasian/L&T.
M/S P K ROY AND SONS
M/S RAKHAL KANTI NAG
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .