Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹38.7 LAccepted-AOC | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹46.8 L+₹8.1 L (21.0%)Rejected-AOC C 88 NIRALA NAGAR NEAR 8 NO CHAURAHA LUCKNOW 226 020 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226020 | L-2 | Rejected-AOC Being other than the lowest bidder | |
| 3 | Rejected-Technical 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | - | Rejected-Technical Not enlisted in requisite Category |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
14 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineer, MES, Bareilly
HEADQUARTERS, COMMANDER WORKS ENGINEER, MILITARY ENGINEER SERVICES, STATION ROAD, BAREILLY CANTT, PIN 243001
CA NO.CWE BLY/GE (W)/ 02 OF 2020-21 REPAIR AND MAINTENANCE OF HT OCBS, VCBS AND MISC WORK AT 33 KV MRS AT BAREILLY UNDER GE (WEST) BAREILLY
2020_MES_339014_2
8100/B/649/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
BAREILLY
For enlisted contractor Class D Category b iii and for unenlisted contractor meeting the eligibility criteria of class D and category b iii
6 documents required · 6 mandatory
₹500
GE West Bareilly
₹88,000
Yes
1 Sept 2020
25 Jun 2020
20 Jul 2020
25 Jun 2020
14 Jul 2020
2 Jul 2020
25 Jun 2020 - 7 Jul 2020
60 days
Amount
Miantenance of 33 KV indoor control and relay panel of 33 KV by checking wiring from outdoor VCB to indoor control panel, tightening of loose connections U/S indicator with holder, thimble, replacement of unserviceable wiring including testing calibration and checking of tripping system of 33 KV control panel through all protective relays installed on each C&R panel including testing and adjust/ repair the alarm circuit as per time current characteristices by primary injuction test at 60%, 75%, 100% plug including well cleaning and decarbonizing of relay contracts complete all as specified and directed.
Overhauling and servicing of 33 KV VCB including repair and setting of operating mechanism parts, spring charging material mechanism, well cleaning with petrol and CRC-226 and replacing unserviceable parts/ accessories, oiling/ greasing of moving parts, dismantling, checking and well cleaning of pole insulator, checking of vaccum, interupters well cleaning mechanism links fible reinforced plastic frame around the vaccum interupts including routine and periodical test complete all as specified and directed.Note:- Spare parts required to make VCB functional will be measured and paid separately under respective items.
Tripping coil 30/110 volt
closing coil 30/110 volt
Spring charging motor
33 KV outdoor VCB vaccum interpter
Spring charging gears
33 KV outdoor CT oil cooled 200/100/5+5
33 KV outdoor PT oil cooled 33KV/110 Volt
Integrated LED pilot lamp suitable for operating at 24 and also 110V (AC/DC) Red colour
Integrated LED pilot lamp suitable for operating at 24 and also 110V (AC/DC) yellow colour
Integrated LED pilot lamp suitable for operating at 24 and also 110V (AC/DC) blue colour
Integrated LED pilot lamp suitable for operating at 24 and also 110V (AC/DC) green colour
Integrated LED pilot lamp suitable for operating at 24 and also 110V (AC/DC) white colour
Auxiliary relay for buchholz relay, oil temp, winding temp trip 24/110V DC
Auxiliary relay for buchholz relay, oil temp, winding temp alarm 24/110VDC
master relay 24/110VDC
Digital ampere meter
Digital volt meter
TNC switch
Remote local switch
Servicing repairing and overhauling of 33 KV isolator including cleaning of complete moving and fixed contracts oiling/ greasing operating mechanismtightening connections and replacement of unserviceable parts including reassembling the isolator after complete repair, routine and periodical testing complete all as specified and directed. Note:- Spare parts required to make VCB functional will be measured and paid separately under respective items.
S&F in repair post insulator of 33 KV air break switch isolator rotating type complete all as specified and directed.
S&F in repair terminal pad of 33 KV air break switch isolator rotating type complete all as specified and directed.
S&F in repair arching horn of 33 KV air break switch isolator rotating type complete all as specified and directed.
S&F in repair connector of 33 KV air break switch isolator rotating type complete all as specified and directed.
S&F in repair operating down pipe of 33 KV air break switch isolator rotating type complete all as specified and directed.
S&F in repair operating box of 33 KV air break switch isolator rotating type complete all as specified and directed.
S&F in repair pad locking of 33 KV air break switch isolator rotating type complete all as specified and directed.
S&F in repair TP locking bolt clamp of 33 KV air break switch isolator rotating type complete all as specified and directed.
Repairing of 33 KV isolator earth link by straightening earth link, replacing wornout knives, bolts nuts, welding cracked joints of operating rod complete all as specified and directed.
S&F PG clamp suitable for dog conductor complete all as specified and directed.
Maintinance and complete overhauling of 11 KV VCB of existing make/ type/mode/capacityl including disassembling of operating mechanism parts well cleaning with petrol and CRC-226 and replacing unserviceable spare parts reassembling of parts including well cleaning the complete panel board,main busbar,decarbonizing all joints busbar CTS, PTS, spouts metal parts and making VCB perfect operating in manual and electric mode and calibration & checking of tripping system of 11 KV circuit breaker through IDMT over current and earth fault relay at plug setting infented inservice by primary current injection method to ensure proper function of trip coil control circuit etc. during fault condition setting by expert complete all as specified and directed. Note:- Spare parts required to make VCB functional will be measured and paid separately under respective items.
Supply only the following spare parts of HT 11 KV VCB for replacement against item No. 14 above.Spares shall be as approved by GE complete all as specified and directed. (a) No volt coil 30 V DC
(b) Shunt Tripping coil 30V DC
(c) Ammeter 0/20 to 100/200 Amp analog type 145 x 145
(d) Volt meter 0 to 15 KV analog type 145 x 145
(e) Vaccum interupter for indoor VCB
(f) Spout incomming side as per existing
(g) Spout outgoing side as per existing
(h) Volt meter 0 to 15 KV digital type
(j) Ammeter 0/20 to 100/200 Amp digital type
(m) Breaker control switch 10A 660V
(n) Electronic hooter 40v DC 96 x 96mm
(o) Push botton Actuators with carrier & contact element- non -illuminated flush spring return push button with 1 NO block, 22mm dia Red colour
(p) Push botton Actuators with carrier & contact element- non -illuminated flush spring return push button with 1 NC block, 22mm dia Green colour.
(q) Integrated LED pilot lamp suitable for operating at 24V (AC/DC) Red colour
(r) Integrated LED pilot lamp suitable for operating at 24V (AC/DC) yellow colour
(s) Integrated LED pilot lamp suitable for operating at 24V (AC/DC) blue colour
(t) Integrated LED pilot lamp suitable for operating at 24V (AC/DC) green colour
(u) Integrated LED pilot lamp suitable for operating at 24V (AC/DC) white colour
(v) Toggle switch assembly
(w) Fuse holders for british pattern fuse links as per IS,13703 2A
(x) Fuse holders for british pattern fuse links as per IS,13703 5A
(y) 11 KV CT 300/150/5+5
(z) 11 KV CT 200/100/5+5
(aa) 11 KV CT 100/50/5+5
(ab) 11 KV CT 50/25/5+5
(ac) Copper busbar of existing size
(ad) Complete VCB housing replacement as per existing size.
(ae) Spring charging gear as per existing
(af) S&F in repair strip type heater 40/60 watt approx 4"/6" in length complete all as specified and directed.
(ag) spring charging motor as per existing
(ah) Closing coil as per existing 30/110 volt
Maintenance and complete overhauling of 11 KV , Oil circuit breaker of existing make/ type/model/capacity including disassembling of operating mechanism parts, well cleaning with petrol and CRC-226 and replacing unserviceable parts, and accessories, oiling / greasing of moving parts includng reassembling fine setting of mechanism removing of oil tank well cleaning and decarbonization of arc control pot fixed and moving contacts ,hinges contacts and repacement of unserviceable parts insulating oil and reassembling and making OCB in perfect operation in manual and electrical mode including well cleaning the complete panel board, main busbar, carbonizing all joints,busbar CTs, PTs spouts metal parts and components etcand calibration & checking of tripping system of 11 KV circuit breaker through IDMT over current and earth fault relay at plug setting infented inservice by primary current injection method to ensure proper function of relays trip coil control circuit etc. during fault condition setting by expert complete all as specified and directed. Note:- Spare parts required to make OCB functional will be measure and paid separately under respective items.
Supply only the following spare parts of HT 11 KV OCB for replacement against item No. 16 above.Spares shall be as approved by GE complete all as specified and directed. (a) Push bottom with NC coil, 22mm dia red colour
(b) Push bottom with NC coil, 22mm dia black colour
(c) LED type indicator lamp assembly red colour
(d) LED type indicator lamp assembly green colour
(e) Toggle switch assembly
(f) Moving contract as per existing size
(g) Fixed contract block assly as per existing size
(h) Shunt trip assembly (30/110 volt DC)
(j) Spout of 11 KV HT OCB as per existing
(k) Tenminal bushing
(l) Finger of 11 KV HT OCB as per existing
(m) Tulip contract
(n) Side plate RH & LH as per existing
(o) Arc control pot with diaphragm
(p) Tank liner
(r) Trip Bar
(s) Bakelite Housing
(t) 11 KV CT 300/150/5
(u) 11 KV CT 100/50/5
(v) Transformer oil
Supply only earth fault and over currect relay, three phase type, Aux supply 50 to 220 V AC/DC with 2NO+2NC contract suitable for 33 KV control and complete all as specified and directed.
S&F non directional IDMT INST over currect and earth fault relay tripple pole (20/ C-1E/F) protection type CDAG-31 core size 3 DH including wiring using copper single core cable 1.5/2.5 sqmm including taking out existing unserviceable relay complete all as specified and directed.
Supply only earth fault and over currect relay, three phase type, CGI14N, Aux supply 50 to 220 V AC/DC with 2NO+2NC contract suitable for 11 KV VCB and complete all as specified and directed.
S&F in replacement phase barriors support including brass bolt/ washer for holding copper bus bar in the HT panel of existing type/ size/ capacity complete all as specified and directed.
Testing and calibration of buchholz relay/ oil temp. indicator ( alarm/trip), winding temp. indicator of 5 MVA transformer complete all as specified and directed.
Maintenance of 33 KV yard comprising of painting the yard with one coat of synthetic enamel paint as required and writing the designation of equipments in english albhabets/ letters as specified and mainly the following:- (i) Transformer 33/11 KV of capacity 5/3.15 MVA-04 (ii) Structure and equipment of VCB-05 Nos (iii) Structure of LA set and equipment of VCB-05 Nos (iv) Structure of isolator and equipment of VCB-05 Nos (v) Gantry structure complete busbar system-01 No (vi) Misc structure-02 Nos (vii) Street lights poles-11 Nos (viii) Iron gate-03 Nos (maximum area 10 Sqm each Gate)
Increasing height of 33 KV outdoor isolator, CT, PT, breaker, LA etc, structure, complete all as specified and directed. Note:- (i) MS channel, MS angle, MS strip will be paid separtely. (ii)One structure is equal to each job.
S&F MS channel, MS angle, MS strip of any size for increasing hieght of 33 KV yard structure complete all as specified and directed.
Repairing of 11 KV indoor PT with replacment of all damage parts complete all as specified and directed.
Attending of emergency complains prefixing to break down of 33 KV outdoor substation bus bars/ 33 KV transformers/ 33 KV or 11 KV VCBs and connected relay pannels of 33 KV MRS by checking the entire system detecting and rectification of the fault and restoration of electric supply of 33 KV/ 11 KV MSR for further distribution. Note:- (1) Experience certificate of technical knowledge of 33 KV power system of a Technician issued by any electrical department officer. (2) The contractor shall report to Engineer-in-Charge/ consurned JE (E/M) immediatly on call during time of breakdown. (3) Material required shall be measured and paid seperatly under relevent items of work.
S&F of 11 KV VCB trolly aluminium busbar incoming side suitable for crompton make VCB complete all as specified and directed.
S&F of 11 KV VCB trolly aluminium busbar outgoing side suitable for crompton make VCB complete all as specified and directed.
S&F of 11 KV VCB trolly fixed contact of spout incoming/ outgoing side suitable for crompton make VCB complete all as specified and directed.
S&F of 11 KV VCB trolly female jaw incoming/ outgoing side suitable for crompton make VCB complete all as specified and directed.
S&F of 11 KV PT spout suitable for 11 KV crompton potential transformer complete all as specified and directed.
Note : Tenderers may note that amount of credit Rs 1,14,505.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
LUMOS INFRA PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .