| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC 14 INDUSTRIAL AREA TILAK NAGAR NEW DELHI BEHIND SUBASH NAGAR METRO STATION WEST DELHI DELHI 110018 | WEST DELHI | DELHI | 110018 | ₹2.7 Cr | L1 | Accepted-AOC Being L1 and Reasonable. |
| 2 | L2₹2.9 Cr+₹20.5 L (7.50%)Rejected-Finance 801802 SAKAR IV OPP MJ LIBERARY ELLISBRIDGE ASHRAM ROAD AHMEDABAD AHMEDABAD GUJARAT 380006 | 801802 | ₹2.9 Cr+₹20.5 L (7.50%) | L2 | Rejected-Finance Being other than L1. |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not enlisted in requisite category d(iv) |
| 4 | Rejected-Technical 7TH FLOOR 7B GODREJ ONE BUILDING PIROJSHANAGAR EASTERN EXPRESS HIGHWAY VIKHROLI E MUMBAI MAHARASHTRA 400079 | MUMBAI SUBURBAN | MAHARASHTRA | 400079 | - | - | Rejected-Technical As per Para 1.7 (a) (v) of Manual on Contracts- 2007 (Reprint 2012) |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not having requisite work experience as per NIT |
Tender Value
₹3.1 Cr
EMD Value
₹3.9 L
Closing Date
30 Jan 2021, 6:00 pmClosed
HQ CHIEF ENGINEER BAREILLY ZONE
HQ CHIEF ENGINEER BAREILLY ZONE MILITARY ENGINEER SERVICES SARVATRA BHAWAN STATION ROAD BAREILLY CANTT
PROVN OF SCADA SYSTEM FOR WATER SUPPLY NETWORK AT BAREILLY
2020_MES_401253_1
CEBZ/BLY/T-12 of 2020-21
Open Tender
Information Technology
Item Rate
180 days
BAREILLY
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,000
Yes
GE (E) Bareilly
₹3.9 L
Yes
22 Mar 2021
16 Dec 2020
4 Feb 2021
16 Dec 2020
30 Jan 2021
11 Jan 2021
Amount
PART-I
Supply,Installation,Commissioning and testing of indoor type micro processor Controller Remote Terminal Unit panel made up of 2 mm thick CRCA sheet suitable for receiving, monitoring, operating & controlling upto 01 No Clorination pump with analyser, pump set up to 04 and pressure transmitter, Ultra sonic sensor, flow meter and motorized valve as per Nos of OHT at pump house (Total qty of OHT- 26 Nos) to operate the water supply system and as per user control with visual annunciation panel/screen with FTTH connection data server suitable to control the system/ pump through cord transmitter /receiver unit modem including 3 ph, 440 volt 50 Hz wiring comprising the following specifications :-
(a) RTU with minimum analog input 16 Nos, Digital input 32 Nos, Digital output 32 Nos analog output 02 Nos for connection of VFD ( Variable frequency drive). (b) RS 485/ Rs 232 communication ports of 8 port switch, MOD bus compatibility, aux supply of 24 V DC (c) Short Message Service (SMS). (d) RTU should have memory capacity of 01 MB for programme of RAM. RTU should support upto 8 MB HD card for data logging and programme transfer etc. RTU should be expended with 8 MB expansion module with scanned time 16ms per basic instruction, operating temperature range 0-55 degree centigrade (e) Universal socket connectivity. (f) Website based, enrolled App energy meter, water measurements system facility including connected items as deemed fit to operate the system (g) Monitoring of complete water supply system with wired command from RTU for switching ON & OFF of pump set as per the water level in Over head tank along with wired control feed back from Ultra Sonic sensor from OHT and should be capable to over ride the system manually in case of Auto failure. The control panel should comprising the following :-
(a) HMI Coloured touch screen display of 7" size LCD display with sealed membrane key of High Intensity to design the graphics for Plant layout with flashing mimic for 01 OHT from 0 to 100% , delivery valve open/close condition and pump set ON/OFF running graphical Mimic and HMI with IOT device function. (Make :- Schneider/L&T - Proface) (b) Single/Reverse phasing, Over/under voltage(OV/UV), Unbalance voltage (UBV), Short circuit(SC), Over Load (OL) & Pump set dry running protection & alarming the fault through SMS to 3 mobile numbers (smart motor protection will be paid separately). (c) Opening and closing of delivery line motorize valves automatically (as per pre set timing) as per software programming and manually by push button in case of auto failure. (d) Phase indicators RYB - 1 SET (for 03 phase) (e) Pump On indication with pilot lamp - 1 SET. Make : SCHNEIDER/ESBEE (d) Delivery Line Open/Close indication with pilot lamp - 1 SET. (Make : SCHNEIDER/ESBEE)
(l) SCADA software will report online trend for remote monitoring. SCADA software with daily operation hours Vs daily flow status report, monthly, yearly reports can be stored for minimum 5 years. SCADA software have bidirectional operation with pump house. SCADA software should monitor the following - (i) water level over head tank via a mobile phone and 42" LED screen reciver unit in mimic format at Master Control Center. (ii) On/Off pump status (iii) Elect supply healthy status (iv) Residual chlorine (v) Delivery valve open/closed with automatic controlling of motorised butterfly valves (for Rising main and delivery valves) as soon as the pump set started.(vi) Indication for any tempering with Smart Protection Controller, PLC Panel and UPS (vii) Chlorine pump ON/OFF with automatic or time based chlorine pump operation as soon the pump set started . (viii) Energy consumption (Phase voltage, plase current, PF, anf frequency). (ix) Automatic priming of pump set on each start of pump set. Note:- SCADA software will report online, Daily operation hour Vs Daily flow status report, monthly and yearly reports can be stored SCADA Softwere should have bi-directional with respect to each Pump house.
(m) Micro processor controlled digital meter for reading pump motor 3 phase voltage, current, PF, Kvah and Kwh of pump set SCADA compaitable. (Make : SCHNEIDER/SECURE/C&S ELECTRIC) The panel shall be wall/Floor mounting and shall be indoor type wall /floor mounted and shall be of suitable size made of 2 mm CRCA sheet powder coated IP 43 confirming to IS-86231 and CPRI approved firm. (The make of controller panel shall be of Advantech controll system Pvt Ltd, ABB, CIMCON, RDS, Sceneider, DV Electromatic Pvt Ltd, POWERTECH SWITCHGEAR, SECO, Siemens, Rockwell)
Notes :- (a) Panel should support more than 50 IOs for actual requirement or for future use. (b) It should have facility to input/output for other sensing eqpts in addition to monitoring pump stn, total flow, pressure, chlorination etc. (c) It should be lockable to prevent tempering with temper sensing system with capacity of taking action on temper detection to sent the information to the data center or send the SMS to specific mobile numbers. These actions be configurable from the data center. (d) Control panel should be provided with necessary arrangements (MCB/relay/RCCB) (Make : L&T/Havells/Siemens) for receiving,distributing, isolating and protection of DC and AC supplies for various control and signaling circuit, potential circuit for relaying and metering and UPS backup of 1 KVA for 15 minutes power backup.
(e) The panel board should process the following actions :- (i) Shut down of pumps in case of any non transient abnormal condition such as high current drawl, thermal over load (ii) Shut down of pump in case of low level of water in sumps/OHT (iii) Operation of all sluice valves (iv) Generation of report through data cable at the pump house. (v) The control panel should give alarm and annunciation of following with its resetting and transmission of same to control room * 415 V power failure * Frequency failure * Abnormal pressure * Motor trip on over load * Pump fails to start/stop * UPS failure * Any type of tempering in the machinery of the installation. * Over flow alarm.
(f) The contractor shall design, develop,install, commission and integrate a PLC at all the Pump house to transmit the data, alarm and graphics to control room and receive command from control room. (g) All the panel at pump house will have messy bus 2160-A, multifunction meter with MOD Bus port for logging of all electrical parameter in the SCADA (h) On line residual chlorine analyser, Motorized butterfly valve, ultra sonic sensor,smart motor protection, energy meter, electro magnetic flow meter, float switch,PPM sensor, UPS, SCADA software and mobile software will be paid seperately. (j) The panel must be compatible with FTTH based connection modem supply by BSNL. (k) The communication of command and data from OHT, delivery valves and chlorine analyser to controll panel at PH through wired network. (l) Data received by the main SCADA control center through FTTH cable should be free from malicious like hackers and malware.
Supply, Installation, Testing and Commissioning of Online Residual Chlorine Analyser with Temperature Compensation along with Flow cell assembly for self cleaning and maintenance free with Residual Chlorine sensor and Transmitter with 4-20 mA output with automatic or time based chlorine pump oeration as soon as the pump start all as specified and directed. (Make : E&H/ Emerson/Hatch)
Supply,Installation,Commissioning and testing of Ultra Sonic non contact for level monitoring for over head tank , continuous level measurement from 0 to 100% of range 230 V AC, 50 Hz or 9-30 VDC as available at site (Make:- E&H/P&F/Baumer) and consisting of following of features:- (i) Principal:-Ultra sonic sound waves water level sensing (ii) O/P Pot 4-20 ma/0-20v (iii) Data transmitting output port (iv) iot operation output port (v) Range 8.00 - 10.00 meters depth (vi) Corrosion free Aluminium / Plastic body with pipe fitting.
Supply and fixing of high torque motorized butterfly valve with gears and adopters self lubricating type,Weather proof with protection against,Over voltage jamming of valve and over current protection with manual by pass wheel arrangement to Open/Close the valve on power failure.Including taking down complete mechnical work , flanged end, jointing material, rubber gaskets, nut-bolts and piping for valve fitting. Valve size : 150mm having 02 nos. limit switches for open/close condition, valve position indicator with output of 4-20mA, as per the direction of Engineer in charge. (Make:- Aira, Stolzel, Delval) consisting of following:-
(i) Valve Size 150MM bore (ii) Designed line pressure 8 kg/sq cm (iii) Operating angle - 90 degree (iv) Disc material - CI with nylon coating (v) Valve type -Butter fly valve PN-10 with geared motor on top (vi) With iot output POT (vii) With Torque 35 Nm running time 20s (viii) With close off pressure 1200 kpa (ix) With operating voltage 230 Vac with 2 in built auxiliary switch, IP 67 (x) With antitheft device micro controller based
Supply and fixing of high torque motorized butterfly valve with gears and adopters self lubricating type,Weather proof with protection against,Over voltage jamming of valve and over current protection with manual by pass wheel arrangement to Open/Close the valve on power failure including taking down complete mechanical work , flanged end, jointing material, rubber gaskets, nut-bolts and piping for valve fitting. Valve size :200mm having 02 nos. limit switches for open/close condition, valve position indicator with output of 4-20mA, as per the direction of Engineer in charge. (Make:- Aira, Stolzel, Delval) consisting of following:-
(i) Valve Size 200MM bore (ii) Designed line pressure 8 kg/sq cm (iii) Operating angle - 90 degree (iv) Disc material - CI with nylon coating (v) Valve type -Butter fly valve PN-10 with geared motor on top (vi) BLANK (vii) With Torque 35 Nm running time 20s (viii) With close off pressure 1200 kpa (ix) With operating voltage 230 Vac with 2 in built auxiliary switch, IP 67 (x) With antitheft device micro controller based
Supply and fixing of high torque motorized butterfly valve with gears and adopters self lubricating type,Weather proof with protection against,Over voltage jamming of valve and over current protection with manual by pass wheel arrangement to Open/Close the valve on power failure including taking down complete mechanical work , flanged end, jointing material, rubber gaskets, nut-bolts and piping for valve fitting. Valve size :100mm having 02 nos. limit switches for open/close condition, valve position indicator with output of 4-20mA, as per the direction of Engineer in charge. (Make:- Aira, Stolzel, Delval) consisting of following:-
(i) Valve Size 100MM bore (ii) Designed line pressure 8 kg/sq cm (iii) Operating angle - 90 degree (iv) Disc material - CI with nylon coating (v) Valve type -Butter fly valve PN-10 with geared motor on top (vi) BLANK (vii) With Torque 35 Nm running time 20s (viii) With close off pressure 1200 kpa (ix) With operating voltage 230 Vac with 2 in built auxiliary switch, IP 67 (x) With antitheft device micro controller based
Supply,Installation,Commissioning and testing of Smart Motor Protection (electronic smart relay for metering and protection with VFD) Controller Having Feature as Protection against UV,OV, Phase loss,Phase unblanced , Phase Asymetery & Auto Phase Polarity Correction with Time Delay & Having Display of V, I ,Pf, Hz with IOT Enabled and Potential Free Feedback Contacts Suitable for 40 hp Motor - 3 Phase Induction Motor with following details. (Make-Rockwell /Siemens/Schnider)
All as per item No 8.00 & 8.01 above but of capacity 50 hp.
Supply,Installation,Commissioning and testing of Energy Meter with class 1 accuracy and RS-485 communication 3 ph, 4 wire (Make- Siemens/Schnider/ Secure/L & T).
Supplying & Fixing on wall/ laying in ground 1.0 Sqmm 4 core copper conductor, for field instruments PVC insulated & Sheathed, armored cable with heavy duty PVC Saddles 60 cm apart complete all as specified and as directed.
Supplying & Fixing on wall/ laying in ground 1.5 Sqmm 7 Core copper conductor, for butterfly valve PVC insulated & Sheathed, armored cable with heavy duty PVC Saddles 60 cm apart complete all as specified and as directed.
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. nexc10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, wateringand well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n exc. 50m in soil and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L river washed and screeened dry fine sand filling in trenches below and above / around under ground cable for cable protection including punniing around cable complete all as specified and directed.
M & L for laying brick as in protection covers over cables usingfly ash bricks complete all as specified and directed.
Supply and laid GI light grade tube 50mm dia in under Road/ drain /culvert fixed to poles wall with flat Iron clamps bolts,nuts,and washers complete all as specified and directed.
Supply, Installation, Testing and Commissioning of rust proof, Maintenance free, Magnetic Float level switch sensors for Service Tank/Underground Sump with following specifications: Principle of operation : Magnetic SCADA Controlled. Magnet : Ferrite Ring Switch : Hermatically operated sealed magnetically operated Read Switch complete all as specified and directed. (Make : CRISTAL/MAHALAXMI/RADIX)
Supply & Installation of maintenance free chemical earthing using electrode of size 50mm bore x 3 m long copper bonded and connected with 25x4mm copper plated GI strip complete with excavation, earth work, cast iron cover with back fill compound (Chemical/Back fill compound gel for earthing enhancement-50kg) complete all as specified and directed. (Make : Erico/ Remedies Earthing System/ True Power). Note : (i) IR Value should be less than1. (ii) Copper plated GI stip of size 25mmx4mm including installation (iii) The earthing system shall be designed, as per the detail given in PS in accordance with IS : 3043-1987 and IEEE 80, Indian Electricity Rules, Codes of practice and regulatons.
Supply, Installation, commissioning & testing of HMI SCADA based software with rendency module SQL database visulization and control development version with minimum 5000 tags and the historian of software shall be design and configurated and minimum to accept the number of tags similar to SCADA software. The historian software and server system shall be designed in configurated to store data for minimum five years for central monitoring and control through wired communication, installed on PC - operation at Main Control Center with suitable L3 network switch and GPS based NTP time server complete all as specified and directed. (Make : Rockwell, Siemens, ABB, Schneider)
Supply of SCADA PC (All in one) with the following parameters:- (Make : HP ,COMPAQ, DELL) (a) Processor- 7th gen intel Core TM i5 7200U processor (3M cache, up to 3.10 GHz) (b) Operating system -Windows 10 Home Plus / 64 bit) (c) MS Office- Latest (d) Anti-virus Software-Kaspersky one system one-year subscription Make : Quickheal/AVG/NET Protector/K7 (e) Display: 42 inch FHD(1920x1080) Anti-glare LED Back Lit display with wide viewing Angle (f) Memory- 8GB Single Channel DDR 4 2400MHz (8 GBx01). (g) Hard Drive - 2 TB,1400 RPM (h) Graphic Card- NVDIA G Force 920 MX with 2 TB GDDR5 graphics memory
(j) Optical drive tray load DVD drive (k) Wireless key board and mouse (l) One-year hardware warranty (m) USB 2.0, RJ 45, audio line out, DC power along with HDMI port (n) Along with suitable speaker 2.1 system. (o) The system must be completely enable to operate all equipments of pump house from PC monitoring screen (1 working + 1 Redundent system) (p) Laser Jet Printer Black & white A4 size (To be installed at installed at control room of GE (West) & GE (East). (Make- HP/Canon/Samsung) (q) UPS of capacity 600VA for uninterupted power supply (Make- APC/Microtek/iball) (r) GPRS modem for SMS- 01 No
Supply and Fixing of UPS of suitable capacity 5 KVA, 230 V AC for back up minimum 15 Min of computer system complete all as specified and directed. Make: Luminus/Exide/ Microtek/ Sukam
Supply,Installation,Commissioning and testing of RTU controller as Data Concentrator Unit for central location for Reporting of 5 years record the Monitoring and controlling the multiple pumping stations as a data server suitable to monitoing and control the system / multiple pumps through Scada page. PLC having High Processing Speed with retandunt Processor Hookup With Modems and Other IOT Extension managed ethernal switch for SCADA IPC and GPS/Printer connection (Make- Siemens/Hirshman) with GPS for time syncronization (Make-SANDS/Masibus) and Network manager comaptible with FTTH connction based modem supplied by BSNL complete all as specified and directed. (Make- Rockwell/Siemens/Schneider/ABB) Note:- Scanning time for monitoring and controlling should be less than 500 ms and data storage for RAM should be 01 minute minimum for 5 years.
Supply,Installation,Commissioning and testing of android Mobile phone (02 Nos) with App soft ware for monitoring water level in mimic format with ON/OFF button for manually controlling of delivery ling motorized valve opening/closing condition in case of emergency, non internet base for GE (E) Bly complete all as specified and directed. (Make of android phone: Samsung, NOKIA, LG.) (Make of android phone software : CIMCON/ MOTOROLA/ ABB/Schneider/ Siemens/Rockwell)
M&L for providing cement concrete 1:4:8 Type D-2 ( using 40 mm grade stone aggregate ) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6, C-1 (using 20 mm graded stone aggregate) as in coping etc laid to slope and finished smooth complete and including necessary form work complete all as specified and directed.
EXCAVATION BY TRENCHLESS TECHNOLOGY - Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa worhing pressure. complete all as specified and directed.
Supply, Installation, Testing and Commissioning of Hot Dip GI Perforated Cable Tray of size up to 150 mm Width with required MS Angle Support and Coupler plate assembly complete all as specified and directed. (Make: AKG/Dudhat/STANDARD)
Supply, installation Testing and Commissioning of Electromagnetic Flow meter in existing pipe line incl cutting, welding of flange etc. of line size up to 125 mm dia. with die cast aluminium enclosure, SS316 Electrode/Hasteelloy, OPTIFLUX2000 flow sensor, micreprocessor based IFC050 tranasmitter/ converter with 0.5 % accuracy, Lining Material Rubber/PTFE, Earthing Bolt, Total Flow and Cumulative Flow Detection with IP68 Flow meter and Transmitter. Field Mount/Remote Transmitter as per site with RS-485 Modbus/HART/Profibus Output into including Gasket, Nuts, bolts, washers etc complete all as specified and directed. (Make: Forbes Marshall / E&H/ Emerson.) (Note- CI specials such as tapers, sockets, tail piece etc will be paid seprately)
S&F and testing of cast iron pipe fittings (specials) heavy duty for spigot and socketed pipes upto 200mm bore of any type such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed.
Supply and install hi wall split units outdoor/ indoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 TR complete all as specifoed and directed. Note- For 24 hrs opreration of SCADA system 01 working AC +01 stand by AC required.
S & F Voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stablized between 220V to 240V wiyh accuracy of +/- 2.5%, with low and high voltage cut off system, overload protection and time delay relay 2 minutes device suitable for water cooler and of capacity 4.0 KVA complete all as specified and directed.
S & F of sub main wiring alongwith earthwire for the two single core 4.00 sqmm size sub main wiring with one single core 4.00 sqmm size earthwire drawn into and including one run 25 mm or higher dia PVC conduit fixed concealed. PVC insulated PVC unsheathed multi-stranded copper conductor cable in and including PVC conduit medium grade ISI marked, fixed concealed of size as mentioned below complete with all conduit all accessories / fittings as required at site and connecting of earthwire to common earth dolly complete all as specified and directed. Note :- Three run of 4.00 sqmm copper cable and one run of conduit shall be measured as one unit.
Supply & fixing of Cable route markers made of galvanized iron with supporting GI angle of size 40 X 40 X 6 mm for stand and plate size 150X150X5mm thick and primering, painting, writting of HT/LT cable route mark for suitable size letters including M/L PCC 1:3:6 type C2 using 40mm graded aggregades in mass concrete or plinth block complete all as specified and directed.
Supply , Installation Testing & commissioning of modem for new FTTH connection points in bareilly cantt for internet connectivity to water supply installation at pump houses-. (32,24,12,28,27,31,25,36,34,33,29,30,38,37/16,MH,22,21,23,20/35,26,37, 41 and central monitoring station-23 Nos) to communicate with main monitoring station to each pump houses with suitable FTTH connectivity plan ( plan id 100 GB_CUL,Speed : upto 20 mbps till 100 GB, 2 mbps beyond 100 GB ,unlimited data download,Local and STD unlimited on any network for 24 hrs)
(a) Modem
Monthly Plan with plan ID 100 GB_CUL,Speed : upto 20 mbps till 100 GB, 2 mbps beyond 100 GB ,unlimited data download, Local and STD unlimited on any network for 24 hrs. Note for item Nos 37, 37.01 & 37.02:- (i) The BSNL monthly plan for the first month shall be taken by the contractor in the name of GE (E) Bareilly. (ii) Regular monthly plan after completion of the first month mentioned as above will be done by the department.
MAINTENANCE & OPERATION WITHIN DEFECT LIABILITY PERIOD (DLP) 24 MONTHS
1. Maintenance & Operation of whole SCADA software system within defect liability period of 24 Months will comprise of monitoring of SCADA software after satisfactory completion of work in Bareilly cantt. (i.e. Maintenance & operation of all the equipments/accessories at site and master monitoring center as specified including complete Scada system). 2.The communication network between pump houses and central control station will be through BSNL FTTH connection. 3. THe SCADA communication system provided must be compatible to work effectively with BSNL FTTH connection. 4. The time delay in data communication among the monitoring and control panels, centralized control / monitoring stations, sensors, transmitters and receivers and operation of euipments/ accessories of pump houses etc should be less than milli second. It includes:-
(i) One Engineer for a Day of 8 hours three Shift round the clock for monitoring and report generation of SCADA system. (ii) Tools and Machinery for whole SCADA Automation system. (iv) The technician shall be professionally qualified engineer not less than Diploma holder in the field of information technology ,instrumentation and control, Electronics or electrical & electronics engineering and shall have knowledge of installation and operation of SCADA System. (v) The quoted rate shall also include the cost of security of entire system i.e. protection from malware attack and data theft etc.for efficient and secured operation of system.
All as per item No 39.00 & 39.01 above complete but for comprehensive maintenance and operation for further 12 month under defect liability period. (Note for sl Nos 39 & 40:- Repair/Replacement of u/s spare of any size any type for entire scada system with materials /Spares for 24 month under defect liability period after completion of work shall be provided by the contractor free of cost.)
PART-II ( MAINTENANCE & OPERATION AND AMC AFTER DEFECT LIABILITY PERIOD)
Maintenance & Operation and AMC of whole SCADA software system of Bareilly cantt. including replacement of unserviceable items/equipments for 36 month will comprise of monitoring of SCADA software after satisfactory completion of work and defect liability period in Bareilly cantt. (i.e. AMC works of all the equipments/accessories other than items covered under Item No 46 to 66 of BOQ are deemed to be included in the quoted rates. It includes:- (i) One Engineer for a Day of 8 hours three Shift round the clock for monitoring and report generation of SCADA system. (ii) Tools and Machinery for whole SCADA Automation system. (iii) Repair/Replacement of u/s spare of any size any type which is part of AMC except the items covered under item no 46 to 66 of BOQ (iv) The technician shall be professionally qualified engineer not less than Diploma holder in the field of information technology ,instrumentation and control, Electronics or electrical engineering and shall have knowledge of installation and operation of SCADA System. (v) The quoted rate shall also include the cost of security of entire system i.e. protection from malware attack and data theft etc.for efficient and secured operation of system.
All as per schedule 'A' item No 42 as mentioned here-in-before but for comprehensive maintenance and operation for further 12 month after complition of item No 42 above.
All as per schedule 'A' item No 42 as mentioned here-in-before but for comprehensive maintenance and operation for further 12 month after complition of item No 43 above.
The following items are under AMC period:-
Supply and fixing 1.0 sq mm 4 Core copper cable complete all as specifoed and directed.
Supply and fixing 1.5 sq mm 6 Core copper cable complete all as specifoed and directed.
Supply and fixing 1.5 sq mm 2 Core copper cable complete all as specifoed and directed.
Supply and fixing pressure Transmitter with accessories and sensor complete all as specifoed and directed.
Supply and fixing Ultrasonic Level Transmitter with sensor complete all as specifoed and directed.
Supply and fixing 100 mm dia, single phase, motor actuated butterfly valve with disc material of CI with nylon coated complete all as specifoed and directed.
Supply and fixing 150mm dia, single phase, motor actuated butterfly valve with disc material of CI with nylon coated complete all as specifoed and directed.
Supply and fixing 200mm dia, single phase, motor actuated butter fly valve with disc material of CI with nylon coated complete all as specifoed and directed.
Supply and fixing ARM7 based CPU card of RTU complete all as specifoed and directed.
Supply and fixing AI card of RTU complete all as specifoed and directed.
Supply and fixing DO card of RTU complete all as specifoed and directed.
Supply and fixing DO termination PCB of RTU complete all as specifoed and directed.
Supply and fixing DI termination PCB of RTU complete all as specifoed and directed.
Supply and fixing Keyboard and display unit of RTU complete all as specifoed and directed.
Supply and fixing Panel interface relay 230 Volt AC 4 C/O complete all as specifoed and directed.
Supply and fixing Panel interface relay 230 Volt DC 4 C/O complete all as specifoed and directed.
Supply and fixing 12/12/5 V DC SMPS of model I RTU 9000 complete all as specifoed and directed.
Supply and fixing 32 TPN class C, MCB complete all as specifoed and directed.
Supply and fixing 100 AH , SMF Battery inverter complete all as specifoed and directed.
Supply and fixing Online residual chlorine analyser with level sensor and temperature compensation complete all as specifoed and directed.
Supply and fixing PPM sensor Potentiostatic electrole with following features. (a) Electrodes -:2 platinum ring (b) Referance- Gel with annual junction (c) Body glass (d) Max presuure-: 10 Bar @ 20 degree C make as approved by E-in-Cs Br.
CIMCON SOFTWARE INDIA PVT. LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .