GE (AF) Jaisalmer
GE (AF) Jaisalmer
Repairs/Maint of RO Plant, Split/Window type AC, Water cooler, Desert cooler, Deep freezers, Refrigerators and misc connected items of E/M works at AF Stn Ramgarh under GE (AF) Jaisalmer
2021_MES_447398_1
8723/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹26,000
Yes
16 Jul 2021
1 Jun 2021
28 Jun 2021
1 Jun 2021
26 Jun 2021
14 Jun 2021
2 Jun 2021 - 8 Jun 2021
Amount
Cleaning down complete body including fitting and fixture of desert cooler of capacity 4000/5000 Cum/hours of any make with wire including removal of all sludges, loose paint dust, dirt etc and prepared the clean surface for painting, and for applying two coats of synthetic enamel paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank, including rewriting of MES No etc complete all as specified and directed.
Taking out fan motor single phase, 230 Volts, 1400 RPM, 3 Speed 1/8 HP from desert cooler and rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bushes and reassembling and re-fixing in same position ccomplete all as specified and directed.
PVC flexible pipe 16mm outer dia with bends complete with PVC elbow fixed in repair complete all as specified and directed.
Wood pad, minimum weight 0.80 Kg, fixed in side panels of desert coolers including taking down old unserviceable complete all as specified and directed.
Desert cooler motor of three speed, 1400 RPM, 230 volts, copper winding single phase with ring, side legs, necessary bolts and nuts of capacity 1/6 to 1/8 HP including taking down old unserviceable complete all as specified and directed.
Capacitor 4 MFD, Single Phase, 440 volt for fan motor of desert cooler with ISI marked including taking down old unserviceable complete all as specified and directed.
Supply, installation and testing desert cooler electric driven single phase having normal air flow capacity 4000/5000 Cum per Hour made out of GI plain sheet of 20 SWG and side panels of 22 SWG, front grill heavy duty having minimum weight 3.0 Kgs made out of GI sheet, wood wool pads (set of three) weight not less than 500 gms superior quality, including suitable motor, water pump, PVC pipe, PVC elbow, PVC distributor three way superior quality for desert including taking down old unserviceable desert cooler complete all as specified and directed. Note : Old unserviceable desert cooler shall be deposit to MES store by the contractor.
Side shutter made out from 0.80 mm thick galvanised iron sheet of capacity 4000/5000 cum/hours desert cooler fixed in repair complete all as specified and directed.
Submersible water lifting pump heavy duty of capacity 1/60 HP, 230 Volts 50 Hz Single Phase, including pump support plate fabricated with 0.40mm thick GI sheet with fixing screws, nuts and bolts for desert cooler including taking down old unserviceable water pump complete all as specified and directed.
Cast Iron ring of cooler Fan motor Leg set (RH & LH) with clamps suitable for desert cooler complete with nuts & bolts including taking down old unserviceable complete all as specified and directed.
PVC, 3 way distributor of water supply suitable for 15mm pipe with nut/screws including taking down old unserviceable complete all as specified and directed.
15mm size stop cock of PTMT in any colour screwed for iron pipe and weight not less than 90 gram per cock fixed in repair complete all as specified and directed.
Removing condenser Fan Motor from water cooler of capacity 40/80, 60/120 & 150/150 litres and rewinding the same with super enameled copper winding wire, same gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with washer nuts and bolts complete all as specified and directed.
15mm bore water tap (Internal thread), cast copper alloy, chromium plated, push type suitable for water cooler of any capacity fixed in repair complete all as specified and directed.
Thermostat suitable for water cooler of any capacity fixed in repair complete all as specified and directed by Engr-in-Charge.
Relay with Over Load Protector suitable for 40 to 150 liters cooling capacity water cooler complete all as specified and directed by Engr-in-Charge.
PVC drain out pipe, heavy duty 32/40mm dia, wall thickness 2mm complete with fittings such as nipple, clips etc complete fixed to water coolers of any capacity fixed in repair complete all as specified and directed.
New freezer unit with door and chill tray including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning including cutting and removing old unserviceable freezer unit of refrigerator capacity 165/170/175/300/310 litres of any make in repair complete all as specified and directed.
Thermostat suitable for refrigerator of capacity 165 to 180 liters fixed in repair complete all as specified and directed.
Compressor suitable for water cooler of capacity 40/80 litre/hour as required including necessary connections and testing fixed in repair complete all as specified and directed.
Compressor suitable for Refrigertor of capacity 165/175/185 litre as required including necessary connections and testing fixed in repair complete all as specified and directed.
Condensing coil suitable for water cooler of capacity 40/80 litre fixed in repair complete all as specified and directed.
Supply only refrigerant gas R-22 for charging where required at site as per direction of Engineer-in-Charge
Supply only refrigerant gas R-134a/407c for charging complete all as specified and directed by Engr-in-Charge.
Servicing of Deep freezer of capacity 300/320 ltrs of any make checking / testing all parts for its serviceability, oiling / greasing to condensed motor including replacing bushes / rubber packing / gasket and insulating material and including repairing door and replacing handle, hinges, nut, bolts, washers etc, checking of refrigerant standing pressure and tapping of refrigerant up to the required level complete including testing for smooth functioning complete all as specified and directed.
Compressor suitable for Deep Freezer of capacity 300/320 litre/hour as required including necessary connections and testing fixed in repair complete all as specified and directed by Engr-in-Charge.
Condenser coil suitable for Deep freezer of capacity 320 Litres fixed in repair complete all as specified and directed.
10 to 20 Amp capacity, metal clad box with top plug and socket, rupturing capacity 20 to 40 Amp, MCB capacity fixed in repair complete all as specified and directed.
Finding out the leakage with the pressure test of condenser or cooling coil of water cooler capacity 40/80 litre cooling/storage and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/ soldering including charging the gas R-22/R-134 and testing the water cooler complete all as specified and directed.
Cooling coil suitable for Deep freezer of capacity 300/320 liters fixed in repair complete all as specified and directed
Condenser coil assembly suitable for Split type Air Conditioner 1.5/2.0 TR fixed in repair complete all as specified and directed.
Condenser coil Assembly 1.5/2.0 TR suitable for window type Air Conditioner fixed in repair complete all as specified and directed.
Coil Evaporator Assembly suitable for 1.5/2.0 TR window type Air Conditioner fixed in repair complete all as specified and directed.
Condenser/Blower Motor of split/window type Air Conditioner of Capacity 1.5/2.0 TR fixed in repair complete all as specified.
Servicing of split type Air Conditioner of capacity 1.5/2.0 TR of any type or make by opening the condenser unit fixed on roof top and cooling unit fixed inside the building, and cleaning the complete condenser unit and cooling unit including fins and checking / testing of all parts for its serviceability, and oiling/greasing of motors, replacing worn-out bushes of blower, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc. and reassembling of complete unit including testing for smooth functioning complete all as specified and directed.
Servicing of window type Air Conditioner of capacity 1.5/2 TR of any type or make including cleaning of filter on front side by removing dust, cleaning the condenser including fins, blower fan motor and checking/testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, replacing worn-out rubber, bushes/rubber packing, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc. and reassembling of complete AC including testing for smooth functioning complete all as specified and directed.Note for serial item No 35.00 & 36.00: (i) Refrigerant Gas required for topping up will be measured and paid separately as supply only under respective item of this Sch 'A' price schedule. (ii) Any spare part of AC if found defective will be measured as supply and fix fixed in repairs under respective item of this Sch 'A' price schedule.
Wire remote control (Micro processor) unit suitable for split type Air Conditioner 1.5 / 2.0 TR capacity of make AMTREX complete with wires of remote fixed in repair complete all as specified and directed.
Sleeve foam Protection suitable for Split type Air Conditioner 1.5/2.0 TR fixed in repair complete all as specified and directed.
Factory made PVC drain pipe suitable for Split type Air Conditioner 1.5/2.0 TR with coupler Joint fixed in repair complete all as specified and directed.
Removing the condenser fan motor from split type Air Conditioner of capacity 1.5/2.0 TR, rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with new washer nuts & bolts complete all as specified and directed.
Running capacitor, 45 MFD and one point for blower motor suitable for Air Conditioner of capacity 1.5/2.0 TR fixed in repair complete all as specified and directed.
Aluminium fan blade suitable for condenser of window/Split type Air Conditioner of any capacity and any type or make complete all as specified and directed.
Starting relay only suitable for window/split type Air Conditioner 1.5/2.0 TR capacity and any type or make fixed in repair complete all as specified and directed.
Over load protector only suitable for window/split type Air Conditioner 1.5/2.0 TR capacities and any type or make fixed in repair complete all as specified and directed.
Reciprocating compressor sealed unit for window type Air Conditioner of capacity 1.5/2.0 TR and including testing for smooth functioning and including taking down old unserviceable compressor complete all as specified and directed.
Rotary compressor sealed unit for window/split type Air Conditioner of capacity 1.5/2.0 TR and including testing for smooth functioning and including taking down old unserviceable compressor complete all as specified and directed.
Thermostat suitable for window/split type Air Conditioner 1.5/2.0 TR capacity fixed in repair complete all as specified and directed.
Cooling fan motor of capacity 1/30 HP or 1/20 HP from split type Air Conditioner, rewinding the same with supper enamelled copper winding wire of existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush and side rubber ring and removing and re-fixing in original position and testing complete all as specified and directed.
Contactor 16 Amp, 4 pole suitable for split/window type Air Conditioner upto 2.0TR fixed in repair complete all as specified and directed.
Contactor 6 to 12 Amp, 4 pole suitable for split/window type Air Conditioner upto 2.0 TR fixed in repair complete all as specified and directed.
Cooling coil suitable for window/split type Air Conditioner of capacity 1.5/2.0 TR including checking its leakage, brazing and completely arresting its leakage, gas charging and testing and any type or make fixed in repair complete all as specified and directed.
Finding out the leakage and pressure test with filling N2 gas inside of the condensor and cooling coil of Package type AC of 10/11 TR capacity and dismantling the same for repair the leakage point by brazing/soldering including taking down and refixing the unit and testing the AC unit complete all as specified.
Induction Blower Motor capacity 2.0 HP, Three Phase, 415 Volt grade, 50 Hz, AC supply, 1400 RPM, (As per Sample) in repair complete all as specified and directed.
Condensor Motor capacity 1.5 HP, Three Phase, 415 Volt grade, 50 Hz, AC supply in repair complete all as specified and directed.
Repair and Maint of Package type AC Plant as followings:
V Belt, belt section code A, length in inches 28/29/30, Oil and Heat resistant, smooth running, belt body made of a special rubber compound in repair complete all as specified and directed.
Gas Charging Valve 1/4 inch as per existing complete all as specified and directed.
Expansion valve to control the refrigerant flow in a refrigeration system including gas welding as per site requirement complete all as specified and directed.
Relay card for condencer motor as per sample complete all as specified and directed.
High pressure/ low pressure (HP/LP) cut out MP-5 as per existing complete all as specified and directed.
P No 205 (set of two) for AC blowers including turning the shaft as per reqirement at site complete all as specified and directed.
Temperature sensor for Air Contioner Plant capacity 10 TR in repair complete all as specified and directed.
Liquid line valve for Air Conditioner Package unit 10 TR capacity in repair complete all as specified and directed.
Blower Shaft suitable for Air Conditioner Plant capacity 10 TR in repair complete all as specified and directed.
Blower suitable for Air Conditioner Plant capacity 10 TR in repair complete all as specified and directed.
MPD range 2-22 Amp as per existing complete all as specified and directed.
Gas R-22 for charging as per existing equipments complete all as specified and directed.
Refrigerant Gas R-407c for charging as per existing complete all as specified and directed.
Comprehensive maintenance for servicing, testing & commisioning of RO plant of existing capacity (01 No) including washing, cleaning, sedimentation, filteration, disinfection process, pressure pumping set & chlorine dosing unit at AF station Ramgarh area so as to supply qualitative water at permissible level of TDS complete all as specified and directed. Note: (a) Spares required for replacement will be measured and paid seperately under respective items here-in this schedule. (b) The rate quotedby the tenderer include the cost of maint/ servicing of above said plant once in a period of 30-45 days till the date of completion of work specified in WO. (c) Parts required shall be measured and paid under respective item.
Taking down the unserviceable High pressure pump (vertical type) capacity upto 5 HP, 3 Phase, 415 volt, from RO plant, dismantling the pump set, replacement of mechanical water seal as per manufacturer's specification, complete servicing the pump set including replacement of bearing and unserviceable items (lock, etc) as required and reassemling complete and refitting at site complete all as specified and directed.
Dozing pump feeder for injecting PH booster, Antiscalent, Chlorine with dosing rate 6 LPH @ 4 KG/CM2, 400 Max stroke/ Minute complete with all fittings and fixtures in repair complete all as specified and directed.
Disconnection of all pressure tubes from the RO Plant and taking out all membranes from pressure tubes cleaning the same with citric acid (low pH) and solium hyppchloride (high pH) and complete washing with RO water and re-assembling the same complete all as specified and directed by Engr-in-Charge.
Pabbels and Gravels, Fine Sand for FRP vessel in lot of 50 Kg bags premixed for filling into vessel FRP/PGV vessel and cleaning the around area and repacking the vessel after filling in new items complete by means of packing and fixing material including labour and testing for appropriate pressure complete all as specified and directed.
Activated Granular Carbon (Charcoal 900 IV) for 21X62 FRP vesseel in lot of 25 KG bags for filling into vessel including draiing out the existing used Charcoal from FRP vessel and cleaning the around area and repacking the vessel after filling in new items complete by means of packing and fixing material including labour and testing for appropriate pressure including taking down old unserviceable complete all as specified and directed.
Supply and provide (Calcium hypo chloride) 65%-70% chlorine including anti corrosive agent content granular desinfectant for water treatment plants much more stable than chlorine gas & stronger than bleaching powder and sodium hypo chloride packed in 45 Kg drum complete all as specified and directed. Note: Test Certificate from government certified lab for each batch of chlorine to be submited at the time of delivery.
Membrane suitable for RO Plant, flow 250 LPH, rejection (%) : 99.67, Model No. CPA2-4040 Nitto of Hydranautics or equivalent of Daw/GE, complete all as specified and directed by Engr-in-Charge.
FRP vessel of size 13X54 (150PSI) for RO plant, in repair complete all as per sample.
Supply only antiscalant solution (suitable for RO plants)
Supply only Jambo micro filter candle for RO Plant (Threaded), 4.50" (Inches) wound complete as per sample all as specified
Water flow meter (rotameter) suitable for RO Plant as per existing capacity, in repair complete all as specified and directed.
UV Filter of capacity 40 Watt, in repair, complete with Lamp suitable for RO Plant of Capacity 3000 LPH.
UV Lamp for UV Filter of Capacity 40 watt sutiable for RO of Capacity 3000 LPH, in repair complete all as specified.
Centrifugal Self Priming Pump of capacity 0.75KW/1.0 HP, size 25X25mm with speed 2760 RPM, insulation 'B' Class with max Current 9 Amps with head range 6/30 M, Discharge Range 60/10 LPM, Single Phase, 50 Hz, Duty-S1, in repair complete with all fittings as directed.
Rotational moulded polyethylene water storage tanks, 500 Litre capacity, double layered, cylindrical vertical with closed top, ISI marked, hoisted & fixed in position & making necessary arrangements for foundation for the tank and fixing inlet, outlet & over flow pipe & provision of wash out pipe including disconnecting & taking down the existing water tank complete as specified in SSR Part-I
Centrifugally cast (spun) Ductile Iron pressure pipes (Class K-7) of 100mm bore with internal cement mortar lining and external zinc coating (130 gm/sqm minimum) and bituminous finish layer (minimum thickness 70 microns) with socket & spigot ends (ISI marked) conforming to IS 8329-2000 (latest revision) suitable for push on rubber gasket joint complete laid in trenches, jointing and testing, including taking down old unserviceable CI/DI pipe complete all as specified & as directed by Engineer-in-Charge. Notes :- (i) All Joints, DI fittings and earth work shall be measured & paid for separately under respective items. (ii) The rates of rubber gasket Tyton Joints are inclueded in this item and nothing shall be extra paid for Tyton Joints.
Galvanized steel water tubing medium grade of 80mm bore with & including all fittings complete, laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 80mm bore, complete all as specified and directed. Note : Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
All as per Serial Item No. 74.00 above but for galvanized steel water tubing medium grade of 50mm bore.
All as per Serial Item No. 74.00 above but for galvanized steel water tubing medium grade of 40mm bore.
All as per Serial Item No. 74.00 above but for galvanized steel water tubing medium grade of 25mm bore.
All as per Serial Item No. 74.00 above but for galvanized steel water tubing medium grade of 20mm bore.
All as per Serial Item No. 74.00 above but for galvanized steel water tubing medium grade of 15mm bore.
Gun metal globe or gate valve screwed both ends with iron wheel head, screwed down high pressure, ISI marked, for 50mm bore pipe line in repair complete all as specified and directed.
All as per Serial Item No. 80.00 above but Gun metal globe or gate valve for 40mm bore pipe line.
All as per Serial Item No. 80.00 above but Gun metal globe or gate valve for 25mm bore pipe line.
All as per Serial Item No. 80.00 above but Gun metal globe or gate valve for 20mm bore pipe line.
Sluice valve cast iron body, heavy duty, class ‘PN-1.6’, long body, 100mm bore, ISI marked with confirming to IS-14846-2000, both flanged ends and drilled, gun metal spindle, Cast Iron gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing including dismantling of sluice valve complete all as specified & directed.
All as per Serial Item No. 84.00 above but Sluice valve of 80mm bore.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 10 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 50 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 70 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium conductor 1100 Volt grade cross sectional area 95 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for laying of cables, pipes, erection of poles, structs/stays etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and getting out soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified.
Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
Dry sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes:- (i) Approved dry sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.
Stone patti 40 to 50mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35cm wide and not less than 80cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
Cutting of bituminous road or any type of floor for laying of pipe not exceeding 1.5 mtr deep including refilling with material and watering well ramming / compacting and making good with PCC (1:2:4) type B-1, 10 cm thick complete all as specified and directed.
Preparation of steel surfaces for electric poles upto 9/11 mtr long extension portion and apply one coat of aluminium paint over full length and marking of pole number and five strips each 30cm wide in black & white colour using synthetic enamel paint upto 1.50mtr height from top of PCC foundation block complete all as specified and directed.
Opening and reassembling of monoblock /centrifugal pump (motor) after rewinding and replacement of worn out spare parts including taking out the burnt winding wire and rewinding of monoblock/ centrifugal pump (motor) of capacity 20/15 HP, Three Phase, 415 volts with new PVC insulated solid copper conductor (wire) superior quality of approved make, size & number of wire as per existing including insulation material, minor spares and replacement of unserviceable spare parts and reassembling the components & testing for function ability, complete, all as specified & directed. Note: (i) The include opening of motor at site for damaging of existing stator winding if found burnt/damaged in front of concerned JE/AGE (E/M) after testing on site before taking to work shop outside MD land and testing of RPM to be done after installation on Ground after rewinding. Motor will be given for repairing as per the site condition and need for repair being maintenance work. (ii) Unit rates shall be deemed to include for all minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding.
All as per Serial Item No. 100.00 above but Monoblock/Centrifugal motor of capacity 12.5/7.5 HP, 3 phase, 415 volts
Deep Groove ball/roller bearing (Double sealed ball bearing) for 20/15 HP Pump (Primary and secondary) as in repair/replacement complete all as specified and directed. Note: The rates include cost of two nos bearing as per pump design. Both the bearings(as per pump make) to be replaced at the same time.
All as per Serial Item No. 102.00 above but Deep Groove ball/roller bearing for 12.5/7.5 HP Pump.
Centrifugal/Monoblock Motor Cooling Fan for 15 HP to 20 HP Pump as in repair/replacement complete all as specified and directed.
Centrifugal/Monoblock Motor Cooling Fan for 7.5 HP to 12.5 HP Pump as in repair/replacement complete all as specified and directed.
Centrifugal/Monoblock Pump motor MS coupling suitable for 15/20 HP motor (Beam, Jaw, Gear any type) as in repair/replacement complete all as specified and directed.
Induction Motor prelubricated ZZ bearing (DE and NDE) for capacity 15/20 HP motor (Primary and secondary) as in repair/replacement complete all as specified and directed. Note: The quoted rates include cost of two nos bearing as per motor design. Both the bearings(as per motor frame type) to be replaced at the same time.
All as per Serial Item No. 107.00 above but Induction Motor prelubricated ZZ bearing (DE and NDE) for capacity 12.5/7.5 HP motor.
CI impellar for 20/15 HP pump as in repair/replacement complete all as specified and directed.
CI impellar for 12.5/7.5 HP pump as in repair/replacement complete all as specified and directed.
Contactor for capacity 20/15 HP, Motor Starter (Amp rating as per site requirement) including removing of exiting burnt and unserviceable contactor and cleaning of carbon complete all as specified and directed.
Contactor for capacity 12.5/7.5 HP, Motor Starter (Amp rating as per site requirement) including removing of exiting burnt and unserviceable contactor and cleaning of carbon complete all as specified and directed.
Motor starter relay for capacity 15/20 HP, Motor Starter (Amp rating as per site) including removing of exiting burnt/unserviceable relay complete all as specified and directed
Motor starter relay for capacity 12.5/7.5 HP, Motor Starter (Amp rating as per site) including removing of exiting burnt/unserviceable relay complete all as specified and directed
Oiling and greasing of pump motor parts (any make any size any type) by means of greasing gun or manually by unbolting and separating the pump motor set at pump house inside defence area completely for smooth operation of machinery including replacement of nut, bolts, washers of appropriate size as per site requirement and motor pump size complete making it leakage free and applying gland packing of necessary quantity and thickness and making working complete noise and leakage free and refixing in same original position complete all as specified and directed. Note: Rates for greese, lubricating oil and gland packing deemed to be included in quoted rates by the tenderer.
Electronic type Single Phase Preventor suitable for 3 Phase, 415 Volt, motor VSP-3 of any make and any size complete as per sample including disconnecting & taking down old unserviceable Single Phase Preventor, complete all as specified and directed.
Pre Stressed concrete Pole 11.00 mtr long, 102mm x 172mm at top and 102mm x 279mm at bottom, class 10 complying with requirements of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint over a coat of primer with black and white strips 30cm wide each upto 1.5mtr height from top of PCC foundation block and numbering of poles, including disconnecting & taking down old unserviceable broken RCC Pole complete all as specified and directed. Note : (i) Excavation in trenches in any types of soil, returning filling in and well ramming including watering and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (ii) PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation bedding complete all as specified and directed. (iii) PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as upto ground level complete all as specified. (iv) PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in coping including necessary form work complete all as specified and directed. (v) Painting of Pole upto 1.5mtr of height from coping level with alternative strip black and sky blue of width not less than 0.30 mtr and writing pole Number with yellow shade on black base using synthetic enamel paint having height of words exceeding 5cm complete all as specified and directed. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Demolishing old existing broken Earth pit chamber and prepare new Earth pit chamber as per site requirement and including putting CI cover complete all as specified and directed. Note: Contractor shall be responsible for removing debris of old PCC chamber from site.
LED flood lights of capacity 100 Watt, complete with all fittings and fixtures in repair complete all as specified and directed
Energy efficient LED street light fittings of Capacity 60 Watt, Aerodynamically designed street light with excellent thermal management in built tilt angle arrangement with IP-66 degree of protection, individuals LED's should have lenses for better throw across & along road range 140-280 volts fittings should be provided 10 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector in built in driver for maximised protections, should have lumens output of 100 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance & includings making electrical connections including taking down old unserviceable complete all as specified and directed. Note:- Driver should be BIS registered with "R" marking.
LED street light fitting pressure die-cast housing aluminium IP66 roadway luminaire with high power COB LED 45W 5000K as light source including taking down old unserviceable LED street light complete all as specified and directed.
Bracket made out of 32mm bore galvanized steel tubing medium grade 1.50m long including bending if required as directed, 02 Nos clamps made out of MS flat iron 50x6mm of including suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts in replacement complete all as specified.
Repair of existing street light/ fitting upto 11 mtr pole height and refixing street light/ cable all as per directed.
Cement concrete Type B2 (1:2:4) (20mm graded aggregate) in foundations, filling and mass concrete for foundation of motor pump set complete by using 10mm thick MS Sheet of approprite size and welding proper size and length of bolt and nut in foundation for avoiding vibration at the time of operation of motor pump set complete with demolition of existing foundation and considering of alignment of motor pump set complete all as specified and directed.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat primer, one under coat and one finishing coat of synthetic enamel paint including disconnecting & taking down old unserviceable complete all as specified and directed.
Trimming of trees falling at LT 1100 V overhead line at road area through radar area complete all as specified.
Garden light LED fitting bollard type 10W IP 65 protection type complete with necessary electric connection and PCC foundation of suitable size as in repair complete all as specified and directed.
Maintenance and servicing of DG Set of capacity 160 KVA complete including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter (primary and secondary), lubricating oil filter, check & clean air cleaner, change air cleaner elements, check coolant level & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc. complete all as specified and directed. Notes: (i) DHPP for testing of DG Sets and Engine Oil shall be issued by the department under Sch ‘B' free of cost. (ii) Fuel filter(Primary), Fuel filter(Secondary), oil filter, bypass filter, water filter, air filter, petroleum jelly, fan belt, fuel pipe, Air cleaner elements complete, Battery legs, Governer repair, gasket, nuts, bolts, claimps, cotton west & Minor extra items shall be provided by the contractor and cost thereof is deemed to be included in quoted rates by the tenderer. No extra cost shall be admissible for DG set servicing on this accounts.
Supply and Filling premixed coolant (35 litre) container complete all as specified and directed
Supply and Filling in sump/ topping up engine oil, multi grade 20W/ 40W in engine or replacement of engine oil complete all as specified and directed.
Dismantling and taking down of old unserviceable self starter of capacity 24 volts from engine and shifting to civil workshop for repair/overhauling of the self starter by rewinding of one field coil, repair and rewinding of armature and fixing it to the existing place after repairing, complete all as specified and directed.
Lead Acid Battery, 24 Volt, 180 AH capacity, with one year warranty, including initial charging and connecting DC cable, thimbles, nut, bolts etc including disconnecting & taking out old unserviceable battery complete all as specified and directed.
Manisha Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .