| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹11.7 L+₹24,903.55 (2.18%)Rejected-AOC | L2 | Rejected-AOC second lowest bidder |
Tender Value
₹12.7 L
EMD Value
₹31,756
Closing Date
22 Mar 2025, 11:30 amClosed
Assistant Executive Engineer
PWD Electrical Sub Division Ernakulam
GENERAL-GMC EKM- Asset Maintenance Fund for the year 2023-24Govt Medical College, Ernakulam-works-General Electrical Work
2025_PWD_747223_1
ESDE(ET)-184/AEE/2024-25
Open Tender
Electrical Works
Item Rate
270 days
Ernakulam
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,760
₹31,756
27 May 2025
15 Mar 2025
24 Mar 2025
15 Mar 2025
22 Mar 2025
15 Mar 2025
Amount
Electrification
1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell
OD50556/2024-2025:Supply and providing the following types and power rated lamps in the existing fittings as required. LED bulb 7W/9W
OD50557/2024-2025:Supply & fixing of LED crystal tube, 1200mm, 20w, 2000 lumen with internal diffused coating providing 320° light output in place of fused ones. (Havells make ST81213SSTL20WLED86S/ Philips make 20w865/ Crompton make LGT8-20-865-2-DS/ reputed make having similar properties
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
OD50558/2024-2025:Supplying and fixing two module piano type stepped electronic fan regulator on the existing switch box including connections.
OD50559/2024-2025:Supply and renewing fan condenser of ceiling fan in place of faulty one and giving connection.
OD50561/2024-2025:Supply and providing every additional length of down rod of suitable size heavy gauge GI / WI pipe with 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming in relevant ISS or with original wiring extended including painting as required.
90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
OD73369/2024-2025:Supply, installation, testing and commissioning of Inline Axial Flow Fan with 3 Phase, 1450 Rpm, 2HP Motor having airflow of 9500CFM.
OD50563/2024-2025:Supply, conveyance, installation, testing and commissioning of 36/40w constant current LED Driver with power factor greater than 0.90 at full load. Osram /Philips/ Crompton make.
OD50564/2024-2025:Supply, conveyance, installation, testing and commissioning of 150W LED Flood light Driver with IP 67 protection with power factor greater than 0.90 at full load and Aluminium pressure die-cast housing, Crompton/ Philips/Osram make
OD50565/2024-2025:Supply, conveyance, installation, testing and commissioning of 70W LED Flood light Driver with IP 67 protection with power factor greater than 0.90 at full load and Aluminium pressure die-cast housing, Crompton/ Philips/Osram make
90.15.3.1:Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete 5 Meters
OD50569/2024-2025:Scaffolding charges for repairing/replacing the light fittings in the street light poles.
OD50570/2024-2025:Providing of Hot dip galvanized G.I. round arm in the existing 7 meter Octagonal pole after dismantling the existing single arm bracket.
90.14.28.2:S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor
90.14.28.7:S & F Motor starters of the following ratingsFully automatic star delta starter for 25HP motor
OD50574/2024-2025:Supply, conveyance, installation, testing and commissioning of 12V, 75AH Tubular battery with 3 years comprehensive warranty - Exide make EL75 and giving interconnections with 10 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable & copper sockets and applying petroleum jelly in the terminals etc.
OD50586/2024-2025:Supply, conveyance and installation of Programmable 24Hrs Analog Timer switch for performing automatic ON-OFF function. Havells make/ equivalent reputed make.
OD50587/2024-2025:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required. FP enclosure for independent mounting of MCB/ RCCB/ RCBO.
OD50588/2024-2025:Supply, conveyance, fabrication and installation of G.I angle / flat frame work.
OD50589/2024-2025:Red, Green, Yellow, Orange colours LED indicator, AC/DC, 22.5 mm cut out dia
OD50590/2024-2025:Supply and providing Flush Spring Return Push button actuators with Contact Blocks, Screw & Captive Clamp 1NO+1NC
OD50591/2024-2025:Supply and Fixing of Blue colour LED indicator, AC/DC, 22.5 mm cut out dia
OD50593/2024-2025:Supply and fixing 16 Sq. mm Terminal Block in the existing panel assembly and giving connections. ( Connectwell CTS16U 76 Amp/ equivalent reputed make having similar properties.)
OD50597/2024-2025:Supplying, installation, testing and commissioning of terminal connector for the termination of cables in the street light poles and giving connection as required.
OD50598/2024-2025:Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required 2.50 cm, 4 cm or 5 cm height
OD50599/2024-2025:Steel reinforcement for RCC work including straightening, cutting, bending and placing in position and binding all complete.
90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.24.3:Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 1X20W LED Lamp with box type fixture
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD50605/2024-2025:Supply, Conveyance, Installation, testing and commissioning of wall mounting fan using mounting brackets supplied along with the fan (450mm sweep, Full metal construction, Orient make- Tornardo wall II - Gun Metal High Flow wall fan)
OD50606/2024-2025:Charges for checking the specific gravity of battery, cleaning the terminals, applying petroleum jelly in the terminals and making the same in good working condition.
OD50607/2024-2025:Charges for rewinding the 3HP blower motor of AHU including transportation to workshop, varnishing the coils with best quality insulation varnish, changing both side bearings, test running including scrapping, cleaning and painting the motor with 2 coats of Grey enamel paint.
OD50608/2024-2025:Charges for rewinding the 5HP blower motor of AHU including transportation to workshop, varnishing the coils with best quality insulation varnish, changing both side bearings, test running including scrapping, cleaning and painting the motor with 2 coats of Grey enamel paint.
OD50609/2024-2025:Supply and filling distilled water in the existing battery.
OD50610/2024-2025:Supply and renewing safety pin, rachit belt, instruction sticker, nozzle, safety clip etc. of fire extinguishers and make the same in proper working condition
OD50611/2024-2025:Supply and renewing discharge hose of 4/5 Kg ABC fire extinguishers and make the same in proper working condition
OD50612/2024-2025:Supply and renewing valve set of ABC fire extinguishers and make the same in proper working condition
OD50613/2024-2025:Supply and renewing pressure gauge of ABC fire extinguishers and make the same in proper working condition
OD267541/2024-2025:Supply and installation of ABC type fire extinguisher 6kg capacity consisting of M.S cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30cm long high pressure discharge hose, nozzle etc. Header Details
OD50614/2024-2025:Charges for cleaning and refilling ABC 5 kg Fire Extinguishers checking the safety valve, locking arrangements etc and make the same in proper working condition
OD50615/2024-2025:Charges for cleaning and refilling DCP 5 kg Fire Extinguishers checking the safety valve, locking arrangements etc and make the same in proper working condition
OD50616/2024-2025:Charges for refilling mechanical foam 9 ltr Fire Extinguishers checking the safety valve, locking arrangements etc and make the same in proper working condition
OD50617/2024-2025:Charges for refilling & servicing CO2 6.5kg Fire Extinguishers checking the discharge valve, nozzle, lock etc. and make the same in proper working condition
OD50618/2024-2025:Charges for refilling & servicing CO2 4.5kg Fire Extinguishers checking the discharge valve, nozzle, lock etc. and make the same in proper working condition
OD50619/2024-2025:Charges for refilling & servicing CO2 2kg Fire Extinguishers checking the discharge valve, nozzle, lock etc. and make the same in proper working condition
OD50620/2024-2025:Charges for cleaning and refilling ABC 6 kg Fire Extinguishers checking the safety valve, locking arrangements etc and make the same in proper working condition
OD50621/2024-2025:Charges for cleaning and refilling ABC 4 kg Fire Extinguishers checking the safety valve, locking arrangements etc and make the same in proper working condition
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
90.4.9:Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.
OD50623/2024-2025:Supply, Conveyance, Installation, testing and commissioning of 300mm sweep, 1400rpm, Heavy duty Exhaust fan working on 230V AC and fixing with necessary anchor bolts, nuts etc. as required. Almonard make
OD50624/2024-2025:Supply, Conveyance, Installation, testing and commissioning of 450mm sweep, 1400rpm, Heavy duty Exhaust fan working on 230V AC and fixing with necessary anchor bolts, nuts etc. as required. Almonard make
OD50625/2024-2025:Supply, Conveyance, Installation, testing and commissioning of 380mm sweep, 1400rpm, Heavy duty Exhaust fan working on 230V AC and fixing with necessary anchor bolts, nuts etc. as required. Almonard make
OD50626/2024-2025:Supply, Conveyance, Installation, testing and commissioning of 225mm sweep, 1400rpm, Medium duty Exhaust fan working on 230V AC and fixing with necessary anchor bolts, nuts etc. as required. Almonard make
OD50632/2024-2025:Supply of 10KVA, 3 Phase Input & 1 Phase Output Online UPS in standalone configuration with built in isolation transformer, PF 0.9, overload capacity 110% for 10minutes, output voltage regulation +/-1% for 100% unbalanced load. (Make Hykon /Numeric make)
OD50631/2024-2025:Supply, conveyance, installation, testing and commissioning of 12V, 26AH SMF battery - Exide make Powersafe Plus EP 26-12V SMF Battery and giving interconnections with 6 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable & copper sockets and applying petroleum jelly in the terminals etc.
OD267647/2024-2025:Supply, conveyance, installation, testing and commissioning of 12V, 200AH Automotive battery for existing DG set with 3 years comprehensive warranty - Exide Xpress XP2000 (200AH) at BATTERY BOSS and giving interconnections with 25 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable & copper sockets and applying petroleum jelly in the terminals etc.
OD267660/2024-2025:Supply and providing 24V, 30A manual type Battery charger suitable for 200Ah Battery, having Ammeter, Full protection against battery overcharging and reverse polarity Over voltage, overload and short circuit protection, reverse battery protection
OD50634/2024-2025:Supply, conveyance, installation, testing and commissioning of 3KVA Online UPS with inbuilt 8 nos. of 7AH SMF batteries - Hykon make. HT1103LS/96V
OD50635/2024-2025:Supply and installation of Battery rack made of G.I duly painted suitable for keeping 20nos of 26 AH SMF Battery.
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
90.6.5.9:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 0.75 sq mm
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.6.5.13:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 4.00 sq mm
90.6.5.14:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 6.00 sq mm
OD50636/2024-2025:Supply, conveyance, installation, testing and commissioning of 12V, 120AH Tubular battery with 3 years comprehensive warranty - Exide make Inva master/EI master and giving interconnections with 10 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable & copper sockets and applying petroleum jelly in the terminals etc.
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
1.23.1:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch
1.23.2:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.2 way 5/6 amps switch
1.23.3:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.15/16 amp switch
1.23.4:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 amp socket outlet
1.23.5:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outlet
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.2:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
2.18:Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.27.6:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.3:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
1.28.6:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
90.10.1.4:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )4 module moulded plastic box on surface
90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
90.10.1.6:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
OD50637/2024-2025: Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) 12 module moulded plastic box on surface
90.12.7.1:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp
90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
90.12.7.3:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
OD50638/2024-2025: Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required. 4 sqmm-16 sqmm with 12 mm wide x 1 mm thick clip
90.12.5.39:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm
90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
OD50639/2024-2025:Supplying and making end termination with brass compression gland and aluminium lug for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 2 x 4 sq mm
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door
90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
OD50640/2024-2025:Supply & fixing 80A to100A High Speed Semi Conductor Protection Fuses - DIN Type, Rated Voltage 500 Volts AC, Breaking Capacity - 120 kA
OD50641/2024-2025:Supply and fixing BS type fuse links 6A to 32 A, 80kA 500 V bolted offset tag type fuse link
OD50642/2024-2025:Supply & fixing 400A High Speed Semi Conductor Protection Fuses - DIN Type, Rated Voltage 500 Volts AC, Breaking Capacity - 120 kA
OD50643/2024-2025:Supply & fixing 315A High Speed Semi Conductor Protection Fuses - DIN Type, Rated Voltage 500 Volts AC, Breaking Capacity - 120 kA
OD50644/2024-2025:Supply & fixing 125A High Speed Semi Conductor Protection Fuses - DIN Type, Rated Voltage 500 Volts AC, Breaking Capacity - 120 kA
OD50645/2024-2025:Supply & fixing 80A to100A High Speed Semi Conductor Protection Fuses - DIN Type, Rated Voltage 500 Volts AC, Breaking Capacity - 120 kA
OD50646/2024-2025:Supply & fixing 2A to 63A High Speed Semi Conductor Protection Fuses - DIN Type, Rated Voltage 500 Volts AC, Breaking Capacity - 120 kA
OD50647/2024-2025:Supply and providing 2.00mm thick Elastomeric fire retardant insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength including fixing with suitable synthetic adhesive,
OD50648/2024-2025:Supply and providing 2.5mm thick Elastomeric fire retardant insulating mat as per IS 15652/2006 to withstand 11 KV dielectric strength including fixing with suitable synthetic adhesive,
OD50649/2024-2025:Supply and providing 3mm thick Elastomeric fire retardant insulating mat as per IS 15652/2006 to withstand 33 KV dielectric strength including fixing with suitable synthetic adhesive,
OD50650/2024-2025:Engaging Electrician for attending E.I maintenance for one day.
OD50651/2024-2025:Engaging Helper for one day for cleaning the light fittings/fan/DB etc., dismantling of existing wiring/fittings and conveying to section store.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2.1.3:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N
2.2.1:Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 16 KA, TPMCCB
2.2.3:Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.160 Amp, 16KA,TPMCCB
4.1.8:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 62.5 mm depth X 2.0 mm thickness
9.4.26:Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.31/2 X 240 sq. mm
9.4.29:Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
GK INDUSTRIES (BID ID -2165551)
Bidder Name
Edward P J
GK INDUSTRIES
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1207076.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .