| 1 | L1₹25.5 LAccepted-AOC 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | ₹25.5 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹27.2 L+₹1.6 L (6.41%)Rejected-AOC | ₹27.2 L+₹1.6 L (6.41%) | L2 | Rejected-AOC Not Being L1 |
Tender Value
₹27.5 L
EMD Value
₹55,000
Closing Date
12 Dec 2022, 6:00 pmClosed
GE(I)(CG)KOCHI
GE(I)(CG)KOCHI BUILDING NO.22/2614, OPP. SANTHOM CHURCH MUNDAMVELI POST RAMESWARAM KOCHI-682 507
DAY TO DAY MAINTENANCE REPAIRS TO INTERNAL EXTERNAL ELECTRIC SUPPLY, WATER SUPPLY, DG SET, LIGHTNING PROTECTION SYSTEM, SECURITY STREET LIGHTS, AIR CONDITIONERS AT CGAE, NEDUMBASSERY, KOCHI
2022_MES_563047_1
GE/CG/8825
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
KOCHI
AS PER NIT/TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I)(CG)KOCHI
₹55,000
Yes
10 Feb 2023
14 Nov 2022
19 Dec 2022
14 Nov 2022
12 Dec 2022
29 Nov 2022
14 Nov 2022 - 21 Nov 2022
Amount
Taking down carefully (copper/aluminum) point wiring complete of any type (batten/surface conduit) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
Material and Labour for point wiring complete using 1.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable (FR) upto and including working voltage 1100volts grade, drawn through and including PVC casing and caping including all accessories ISI marked including press fit white PVC open switch/surface board high strength and crack resistance and unsheathed copper conductor stranded cable(FR) earth continuity wire connected to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area and all other metal parts with earth dolly for the following:-. (a ) one light point controlled by one switch 5 Amps
(b ) one fan point point controlled by one switch 5 Amps
(c) One 3 pin socket outlet 5 Amps on Independent board
(d ) One 3 pin socket outlet 5 Amps on same board
( e) One bell point controlled by one bell push
All as per Item No. 2 above but with 4sq mm PVC insulated copper conductor cable(FR) including4 sq mm PVC copper conductor used as earth wire for power point on independent board for One 3 pin socket outlet, 15 Amps.
Supply and fix in repairs Switch piano Flush, single pole, one way 5 amp 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply and fix in repairs Socket outlet 2 in 1, 3pin 5 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply and fix in repairs Switch Socket Combination 2 in 1, 5 Amps /16 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply and fix in repairs Socket outlet 2 in 1, 5 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply and fix in repairs Ceiling rose in poly carbonate 3 plates flush type 6 Amps, 230 volts AC complete all as specified and directed.
Supply and fix in repairs Bell electric Ding Dong 230 Volts, AC, with ISI mark complete all as specified and directed.
Attending internal/ external electric complaint for maintenance/breakdown, round the clock for maintenance, checking, fault finding and rectification of fault in LT panels/Overhead HT/LT lines, transformers, switchgears and carry out repairs and resume electric supply complete all as specified and directed by Engineer-in-charge. Note:- (a)Day to day complaint rectified by the Electrician shall be written in complaint register and completion report recorded in complaint register and complaint document slip rectified complaints only will be paid. (b) The spares required for the rectification of fault shall be measured under items 12 to 36. (c) 5 Nos complaints will be treated as one job
Supply only Switch piano Flush, single pole, one way 5 amp 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply only of Modular switch, one way, 6Amps complete all as specified and directed.
Supply only Modular switch, one way, 16Amps complete all as specified and directed.
Supply only Bell push 5 Amps one way complete all as specified and directed.
Supply only Modular Bell push, 6 Amps complete all as specified and directed.
Supply only Bell electric Ding Dong 230 Volts, AC, with ISI mark complete all as specified and directed.
Supply only Modular socket outlet, 5 Amps, 2 and 3 pin combined complete all as specified and directed.
Supply only Modular socket outlet, 5 Amps/ 16 Amps, 2 and 3 pin combined complete all as specified and directed.
Supply only Modular fan regulator 230 volts, step type, 120 watt complete all as specified and directed.
Supply only modular white cover plate with frame 1 module complete all as specified and directed.
Supply only modular white cover plate with frame 2 module complete all as specified and directed.
Supply only modular white cover plate with frame 4 module complete all as specified and directed.
Supply only modular white cover plate with frame 6 module complete all as specified and directed.
Supply only socket outlet 2 in 1, 3 pin, 6/16 Amps flush type complete all as specified and directed.
Supply only socket outlet 2 in 1, 3 pin, 6 Amps flush type complete all as specified and directed.
Supply only Modular Switch Socket Combination 16 Amps 6 pin complete all as specified and directed.
Supply only Ceiling rose in poly carbonate 3 plates flush type 6 Amps, 230 volts AC complete all as specified and directed.
Supply only Lamp holders baklite body with back plate suitable for battern fitting/angle fitting complete all as specified and directed.
Supply only LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.Make ;CELS ct pt no CLLC-20W or Surya ct pt no SLEBT20GI or equivalant Havells/CG/Philips
Supply only LED light fitting mirror type with high out put diffuser 2 feet,10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make Cat pt no BCLSB 10WH of Bajaj / surya SLE BT 10W ARROW / Shakti ct pt no SZSLAMX010-iss or equivalant of Havells/Philips
Supply only LED luminaire 600 mm x 600 mm,40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make Shakti cat pt no SZRSRMX040-DTVT / Surya cat pt no SLE DS 40 22R-ASTRUM or equivalant to Bajaj/Havells/ CG
Supply only round shape12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.Make Surya cat pt no SLE DLS 12 W RIVO RD XX / Shati cat pt no SZSDRMX012 or eqivqlqnt ti Bajaj/havells/CG
Supply only LED bulb 9 watts, 230 volt complete all as specified and directed. Make: LED ADORE 9 W E27CDL / Shakti SZBLB22009 or equivalent in Philips/Bajaj/Surya.
Supply only Condenser 2.5 Mfd AC 240V, complete all as specified and directed.
Supply only Condenser 4 Mfd AC 240V, complete all as specified and directed.
Supply and fix MCB SPN, 240 Volts, 6 to 32 Amps rating 240 V, breaking capacity of 10 KA, 'C' Curve complete all specified and as directed.
Supply and fix MCB SPN, 240 Volts, 40 to 63 Amps rating 240 V, breaking capacity of 10 KA, 'C' Curve complete all specified and as directed.
Supply and Fixing MCB TPN 415 Volts, 50Hz, 3 phase of capacity 40 Amps, C curve 10 KA breaking capacity, fixed properly in DB and connecting/testing complete all as specified and as directed.
Supply only energy efficient LED building security light Fitting 25 Watts on existing backets including connection with twin coe flexible PVC 0.5 Sqmm cable complete all as secified and as directed. Make:Philips Model No.BRP022 LED 20CW MR S1 PSU GR or Havells Cat Part No LHETBXU7PA6S020 or Wipro Cat No.LR02-291-XXX-57-XX.
Material and labour for Sub main wiring using two runs of single core PVC insulated cable (FRLS) 6 sqmm copper conductor multi stranded and one run of 6 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including suitable size PVC casing and caping including taking down old aluminium/Copper Sub main wirng complete all as specified and directed. Note- 3 run of 6 sq mm PVC copper wire and One run of PVC casing caping shall be measured and paid as one unit.
Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 4 way with 200 Amps rated copper bus bar double door protection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer Double door, flush to wall complete all as specified and directed .
Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 8 way with 200 Amps rated copper bus bar double door protection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer Double door, flush to wall complete all as specified and directed .
Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 12 way with 200 Amps rated copper bus bar double door protection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer Double door, flush to wall complete all as specified and directed .
Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, TPN 4 way with 200 Amps rated copper bus bar double door protection, neutral bar,earth bar, single pole and neutral 415 volts, MCBs used as incommer Double door, flush to wall complete all as specified and directed .
Supply and fix in repairs single pole and neutral enclouser with a two pin and earth plug and socket complete with and including one MCB single pole 20 Amps complete all as specified and directed.
Taking down fan of any type and size after disconnecting, depositing to store yard and Hanging/fixing only after repair/reconditioning fan of any type and size all as directed. NOTE: Repair and reconditioning of fan shall be measured and paid separately under Item Nos. 48 to 51.
Collecting unserviceable ceiling fan 1200mm/1400mm sweep 230V, AC single phase from store yard of AGE E/M and transporting to local market, cutting unserviceable winding from fan stater & rewinding same with super enamelled copper winding wire of existing gauge size including throughly cleaning all the components, oiling greasing & replacement of rusted unserviceable screws, hanging clamps with rubber reel, canopy condensers, bush, bearing & flexible copper connection wire etc complete all as directed. Note : (i) Taking down and refixing after repair work shall be measured and paid under Item No.47 above. (ii) Spare such as Hanging clamps, canopy, condenser and flexible copper connection wire, painting, down rod, bearing, bush, clamps etc shall be measured & paid separatetly under item Nos.55 to 60.
All as per item No 48 above but exhaust fan 250 mm sweep
All as per item No 48 above but exhaust fan 300 mm sweep
All as per item No 48 above but wall fan 300 mm sweep
Material and Labour for Scraping down old paint of exhaust fan/ ceiling fan of any size 250/350/1200 mm sweep complete body & blade including down rod filling the cavities with filler and making smooth surface by applying sand paper painting the ceiling fan by means spray gun/brush with synthetic enamel white paint complete all as specified and directed.
Material and Labour for lathe work for proper filling/fixing of bearing/bushes in the top cover of the fan by filling a layer of matter after blazing & bottom cover of fan complete all as specified and directed.
Material and Labour for lathe work for proper filling/fixing of bearing/bushes in the top cover of the fan by filling a layer of matter after blazing & bottom cover of fan complete all as specified and directed.
Supply only Ball bearing Ser No 6201 or 6202 complete all as specified and directed. Make : MDS/SKF/NBL
Supply only Ball bearing Ser No 6203/6204 complete all as specified and directed. Make : MDS/SKF/NBL or as per existing specifications as per sample
Supply only Gun metal bush for ceiling fan complete all as specified and directed.
Supply only Shackle type rubber reel,'U' clamps, bolts, split pin & washer complete all as specified and directed.
Supply only Canopy top/bottom suitable for 20mm dia rod complete all as specified and directed.
Supply only 1.2mm thick mild steel top/bottom cover for ceiling fan any size and make complete all as specified and as directed .
Supply only Fan blades suitable for 1200mm sweep fan make & type complete all as specified and as directed .
Supply and fixing in repairs Exhaust fan blade (three leaves) of 250mm sweep complete as per sample of the following sizes complete all as specified and as directed .
Supply and fixing in repairs Exhaust fan blade (three leaves) of 300mm sweep complete as per sample of the following sizes complete all as specified and as directed .
Supply and fixing in repairs Wall mounting fan blade 450 mm sweep (three leaves) and make suitable for fixing and as per sample of existing fan complete all as specified and directed.
Supply and fixing in repairs oscillating mechanism suitable for wall mounting fan any make and type all complete all as specified and as directed.
Supply and fixing in repair of Exhaust fan Motor of 300mm sweep heavy duty complete as per sample complete all as specified and as directed.
Supply and fixing in repair of Exhaust fan Motor of 300mm sweep heavy duty complete as per sample complete all as specified and as directed.
Material and labour for servicing including cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil for split type AC of any make/ capacity after taking down the whole unit and refixing at the existing location or any other new location after servicing all as specified and directed . Note: Spare parts shall be measured and paid separately under relevant item.
Shifting of split type AC existing location/from MES yard to the new location by taking it after pumping filling and making good the opening of old location with cement mortor, applying treatment of wall to matching with existing colour and finish and making opening holes on brick wall at new location and gap well finish with cement mortor, applying finish to wall to match with existing colour of the adjacent surface , installation and commissioning with replacement of insulation of suction and discharge line complete all as specified and directed.
Shifting of water cooler electric driven single phase any make and capacity from MES yard/existing location by taking it after disconnection of electric and water line and refixing the same in any other new location including water and electric reconnection complete all as specified and as directed
Supply and fix in repairs Printed Circuit Board suitable for 2TR Capacity Split Unit Air Conditioners including remote, etc. all as specified and as directed. NOTE: Make of PCB & remote shall be of existing manufacturer as compatible with the AC.
Supply and fix in repairs Printed Circuit Board suitable for 1.5TR Capacity Split Unit Air Conditioners including remote, etc. all as specified and as directed. NOTE: Make of PCB & remote shall be of existing manufacturer as compatible with the AC.
Disconnecting, dismantling and taking out existing burnt out compressor from window/Split type Air conditioner 2 TR Capacity and supply and fixing sealed unit compresser of existing capacity 2 TR, single phase, 230 V AC supply initialy filled with compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer complete all as specified and as directed. Make : LG/ Voltas/ Samsung
Disconnecting, dismantling and taking out existing burnt out compressor from window/Split type Air conditioner 1.5 TR Capacity and supply and fixing sealed unit compresser of existing capacity 1.5 TR, single phase, 230 V AC supply initialy filled with compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer complete all as specified and as directed. Make : LG/ Voltas/ Samsung
Disconnecting, dismantling and taking out existing burnt out compressor from water cooler of capacity 40 to 80 Ltr per Hour singlephase 230 volts and supply and fixing compressor unit of water cooler of capacity 40 to 60 ltrs complete all as specified and directed. Make : LG/ Voltas/ Samsung
Supply and fix in repairs AC blower fan motor for AC suitable for 2 TR AC suitable operate on 230 Volt AC supply at 50 Hz complete all as specified and directed.
Supply and fix in repairs AC blower fan motor for AC suitable for 1.5 TR AC suitable operate on 230 Volt AC supply at 50 Hz complete all as specified and directed.
Supply and fix in repairs blower fan motor water cooler capacity 40/80 suitable operate on 230 Volt AC supply at 50 HZ complete all as specified and directed.
Supply and fix in repairs Capacitor 45 MFD complete all as specified and directed.
Supply and fix in repairs Capacitor 50 MFD complete all as specified and directed.
Supply and fix in repairs Thermostat switch for water cooler/Window AC complete all as specified and directed.
Supply and fix in repairs Drier stainer filter suitable for AC/Water cooler/Refrigertor complete all as specified and directed.
Supply and fix in repairs insulation Nytrile foam insulation suitable for 5/8 inch copper tube as per site requirement of approved make all as specified and directed .
Supply and fix in repairs insulation Nytrile foam insulation suitable for 1/4 inch copper tube as per site requirement of approved make all as specified and directed .
Supply and fix in repairs Copper tube 5/8 inch size as per site requirement of approved make all as spd and directed .
Supply and fix in repairs Copper tube 1/4 inch size of approved make all as specified and directed .
Supply and fix in repairs Evaporator unit (indoor unit ) complete suitable for 2 TR Capacity Split type Air Conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/ Voltas/Goderj
Supply and fix in repairs Evaporator unit (indoor unit ) complete suitable for 1.5 TR Capacity Split type Air Conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/ Voltas/Goderj
Supply and fix in repairs Condensing (Out door) unit complete including compressor, etc. suitable for 2 TR Capcity Air conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/Voltas/Goderj
Supply and fix in repairs Condensing (Out door) unit complete including compressor, etc. suitable for 1.5 TR Capcity Air conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/Voltas/Goderj
Supply and fix in repair Bracket stand suitable for 1.5/2 TR Capacity Split type AC including Fastners, etc. Complete all as specified and directed.
Supply and charging R-134A/ R-410A gas to maintain the required cooling effect as and when required in the water cooler, Refrigerator and other cooling applinces complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth for taking out and laying UG cable and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.
Removing excavated soil and depositing to the sides and returning filling in including spreading leveling watering and well ramming in layers n.exc 25cm thick in soft/loose soil after cable is laid complete all as specified.
Material and labour for providing dry screened river sand as in sand cushioning to under ground cable including punning down of sand by layer complete all as specified and as directed. NOTE: Punned thickness shall be measured and paid.
Supply and laying cable protection cover un- reinforced precast concrete cable covers class LV, type-1 flat size 250mmx150mmx40mm for cable protection complete all as specified laid perpendicular to cable as per directed.
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 50 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
All as per item No 98 above but of size 16 Sqmm 4 core.
All as per item No 98 above but of size 6 Sqmm 2 core.
Material and Labour for 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed.
Material and Labour for 80 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed.
Supply & Fix in repairs MCCB 4 pole 415 Volts adjustable type of capacity 63 Amps, 16 KA breaking capacity, lcs=100%lcs fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Cat part No IHLE1ABF0063 of Havells or Equivalent in L&T / Legrand.
Supply & Fix in repairs MCCB 4 pole 415 Volts adjustable type of capacity 100 Amps, 16 KA breaking capacity, lcs=100%lcs fixed properly at directed location and connecting/testing complete all as specified and directed.
Supply & Fix in repairs MCCB 4 pole 415 Volts adjustable type of capacity 160 Amps, 36 KA breaking capacity, lcs=100%lcs fixed properly at directed location and connecting/testing complete all as specified and directed.
Supply & Fix in repairs MCCB 4 pole 415 Volts adjustable type of capacity 200 Amps, 36 KA breaking capacity, lcs=100%lcs fixed properly at directed location and connecting/testing complete all as specified and directed.
Supply & Fix in repairs MCCB 4 pole 415 Volts adjustable type of capacity 400 Amps, 36 KA breaking capacity, lcs=100%lcs fixed properly at directed location and connecting/testing complete all as specified and directed.
Supply and fixing in repairs shock treatment chart duly framed using 1st class hard wood frame size 25mmx15mm treated french polish, mounted on 6mm thick AC building board or commercial plywood and fixed with wooden plugs with 5mm thick plain glass, the area of board 1.20 Square Metre complete all as specified and directed.
Supply and fix in repairs aluminium strip 25x3 mm with saddle and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed.
Supply and fix in repairs GI Strip 32x6 mm with saddle and fixing screws etc from test terminal block to earth pit complete all as specified and directed.
M & L for conducting oil filtration by stream line / Vacuum type filter machine to remove the moisture/carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for power transformer & as BDV of oil 40 to 50 KV for 1 min for distribution transformer incl routine testing after filtration for any capacity of transformers/AVR/CT/PT units all as directed. (Note : The contractor shall change the filter assy before starting the filtration of transformer / AVR in presence of Engr In charge) Note:- (i) Test results before and after filteration shall be submitted on completion in tripilicate. (ii) Necessary electric for filtration plant shall be issued by department,required length of cable/switch etc shall be arranged by the contractor.
Supply and filling of fresh transformer power oil of BDV not less than 60 KV for topping up of reduced level of transformer due to evaporation/ leakage/losses due to dehydration or for replacement complete including removing of old unservicable transformer oil into conservator tank/body tank of transformer as per IS-335 2018 complete all as specified and diredcted. Note:- 1. The taransformer oil for topping up shall beof Di-electric strength more than 60 KV for 1 miniute at 2.5 mm gap between the two electrodes. 2. Oil shall be supplied at site in sealed barrel.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 63 KVA to 400 KVA out door type transformer including taking down u/s from the transformer complete all as specified.
Supply and fix in repairs LED Street light fitting 60 Watt Out door type, made of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having top opening separate driver compartment with IP66 protection complete all as specified and as directed. Make: Crompton/Havells/Philips
Taking down existing unsv terminal box and S & F hot pressed moulded SMC junction/terminal box of internal diemension of 200x140x95 mm and hinged door,including 01 No 4 way connector 415 Volt, 63 Amp, made out of polycorbanate or bakelite and 1 No MCB of 6 AMP with DIN bar,drilling holes for cable connections connecting incomming and or out going cables by providing cable luggs/glands of suitable size fixed on pole by means of clamps made out of MS flat iron of suitable sizes,duly painted with two coats of red oxide zince primer complete all as specifiedand directed.
Supply and fixing in repairs of Omni-directional, elevated,Taxiway edge light with Blue 1Watt LED and blue lens,including electronic convertor, breakable coupling, base plate,secondary lead,set of SS bolt /washer set with suitable lamp and holder and suitable to operate with 2.8 Ampnto 6.6 Amp power source and cable coonnection from transformer to light fitting complete as per FAA L-823, including testing and commissioning all as per ICAO standards and as directed at site. Make: Havells/Polycab/Finolex/ICC/Unistar/NICCO/Asian/CCI/Gloster
Supply and fixing in repairs/replacement LED high bay lights, 150 Watt energy saving, environment friendly & robust LED luminarie with high efficacy suitable for ceiling (Surface/Suspended) all as directed. Make : Havells or equivalent
Supply and fixing in repairs cable single core 6 Sqmm, 5KV grade , PVC insulated, PVC sheathed, unarmoured stranded copper conductor as per IS-1554 Part-II as amended upto date laid in trenchs/floor/wall/drawn through pipes/conduits etc. complete including testing and commissioning all as per ICAO standards and as directed at site. Make: Havells/Polycab/Finolex/ICC/Unistar/NICCO/Asian/CCI/Gloster
Supply and fixing in repairs/replacement for series type Isolating Transformer 15W, 6.6/6.6 Amps, 5 KV grade, 50 Hz, moulded with neoprene type rubber with primary and secondary connectors for elecated type light fitting complete including testing and commissioning all as per ICAO standards and as directed at site. Make: Bildal/Vajra Transformers Pvt Lmt/Truetech Products/Insel Rectifiers India or equivalent
Supply and fixing in repairs push button switches for ON/OFF and emergency stop for hanger doors motor control all as directed.
Supply and fixing in repairs/rewinding for Electric motor for hanger doors rated 10 HP, 3 phase suitable for voltage 415 Volt + 10%, frequency 50 Hz + 5%, continuous rating (S1 Duty) IP-55 enclosure, 3000 RPM all as specified and directed. Make: Havells/Crompton/Bajaj or equivalent
Cleaning and preparation of old painted surface of steel pole 11 mtr long excluding planting depth complete and painting with one coat of aluminium paint and making black and white strips with synthetic enamel paint 30 cm height, each alternative strips ,up to 1.5 mtr height and writing pole Nos and applying one coat of cement base paint on PCC coping complete all as specified and as directed.
M & L for painting the outer surface of the transformer with two coat of greenovoc water based polymer paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing the MES/SM No with white enamelled paint all as directed for capacity of transformer 100 KVA to 600 KVA (Indoor/outdoor type).
M & L for painting of HT/LT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun all as directed.
Supply and fix galvanised steel water tubes, medium grade, 25mm bore with and including all GI fittings such as bends, L bows, short piece connections, backnuts, caps plugs, unions couplings, flanges, sockets etc., laid in trenches/floor including inter connection between buildings/pumps/pump houses and taking out old existing GI tubing complete all as specified and as directed.
Supply and fix galvanised steel water tubes, medium grade, 40mm bore with and including all GI fittings such as bends, L bows, short piece connections, backnuts, caps plugs, unions couplings, flanges, sockets etc., laid in trenches/floor including inter connection between buildings/pumps/pump houses and taking out old existing GI tubing complete all as specified and as directed.
Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20 mm bore complete all as specified and directed.
Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 25 mm bore complete all as specified and directed.
Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 40 mm bore complete all as specified and directed.
Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 50 mm bore complete all as specified and directed.
Taking out old unserviceable Foot valve and supply and fixing new CI Foot valve 50mm dia approved make including jointing complete all as specified and directed at site.
Taking out old unserviceable Foot valve and supply and fixing new CI Foot valve 80mm dia approved make including jointing complete all as specified and directed at site.
Supplying and laying 50mm 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain &brass threaded polypropylene random fittings fixed complete to walls, ceilings or infloors etc after taking out unserviceable pipe including making good disturbed surfaces complete all as specified and directed.
Supplying and laying 40mm 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain &brass threaded polypropylene random fittings fixed complete to walls, ceilings or infloors etc after taking out unserviceable pipe including making good disturbed surfaces complete all as specified and directed.
Supply and fixing of PP-R Gate valves (brass insert) as per requirement of the site in PP-R pipe line of size 50 mm bore, ISI Marked, complete with necessary arrangements for fixing complete all as specified and directed.
Supply and fix in repairs Float valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe suitable for 20mm bore complete all as specified and as directed.
Supply and fix in repairs Float valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe suitable for 25mm bore complete all as specified and as directed.
Cleaning of rain water sand filter tank of 50,000 Ltrs capacity by removing the sediments, old sand & aggregated from inside the tank and refill the sand and aggregates after cleaning and sun drying to required level by adding additional sand and aggregates of existing grading to the fillter tank as required including washing the tank using bleaching powder, removing sludge from tank until a clean bottom surface obtained and writing with white paint over black base on the tank as "TANK CLEANED ON" with date and the capacity of sump with 5 cm high letters/ numbers complete all as specified and as directed.
Cleaning of rain water sand filter tank of 1000 Ltrs capacity by removing the sediments, old sand & aggregated from inside the tank and refill the sand and aggregates after cleaning and sun drying to required level by adding additional sand and aggregates of existing grading to the fillter tank as required including washing the tank using bleaching powder, removing sludge from tank until a clean bottom surface obtained and writing with white paint over black base on the tank as "TANK CLEANED ON" with date and the capacity of sump with 5 cm high letters/ numbers complete all as specified and as directed.
Cleaning of rain water sand filter tank of 750 Ltrs capacity by removing the sediments, old sand & aggregated from inside the tank and refill the sand and aggregates after cleaning and sun drying to required level by adding additional sand and aggregates of existing grading to the fillter tank as required including washing the tank using bleaching powder, removing sludge from tank until a clean bottom surface obtained and writing with white paint over black base on the tank as "TANK CLEANED ON" with date and the capacity of sump with 5 cm high letters/ numbers complete all as specified and as directed.
Cleaning of rain water sand filter tank of 500 Ltrs capacity by removing the sediments, old sand & aggregated from inside the tank and refill the sand and aggregates after cleaning and sun drying to required level by adding additional sand and aggregates of existing grading to the fillter tank as required including washing the tank using bleaching powder, removing sludge from tank until a clean bottom surface obtained and writing with white paint over black base on the tank as "TANK CLEANED ON" with date and the capacity of sump with 5 cm high letters/ numbers complete all as specified and as directed.
Cleaning of rain water sand filter tank of 250 Ltrs capacity by removing the sediments, old sand & aggregated from inside the tank and refill the sand and aggregates after cleaning and sun drying to required level by adding additional sand and aggregates of existing grading to the fillter tank as required including washing the tank using bleaching powder, removing sludge from tank until a clean bottom surface obtained and writing with white paint over black base on the tank as "TANK CLEANED ON" with date and the capacity of sump with 5 cm high letters/ numbers complete all as specified and as directed.
Repair works to submersible motorpump set having capacity 7.5HP 3 phase 415 volts, shifting to the civil workshop for removing of burnt windings, bearing etc, including cleaning the slots, rewinding with new stove enamelled copper wire as per existing size, including changing of bearings, etc , and installation, testing complete as per manufacturer's instruction with entire satisfaction of Engr-in-charge. Note- Rate quoted shall be inclusive of cost of spares as required for repair work.
Disconnecting existing water/electric connections, dismantling unservicable electric Motor pump set having capacity 5 HP 3 Phase, opening carefully, taking out old burnt windings, cleaning of solts of motor stator and rotor complete, rewinding the same with super enamelled winding wire of existing gauge/size as per exisitng pattern with proper insulating material apply two coats of varnish and heating of windings reassemble the motor with proper sealing, including necessary lathe work to made the pump high efficiency, etc. refixing the same location, including necessary plumbing work, etc., testing and commissioning of motor pump set on full load to the entire satifcation of the Engineer-in-Charge.
M/L for Maintenance and servicing of standby DG Set 100 KVA complete including draining out of diesel from tank , cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the sump, cleaning the sump thoroughly and refilling the sump with new engine oil to it’s required level, replacing the fuel filter, lubricating oil filter , check & clean air cleaner , change air cleaner elements, check coolant level & make up the same ,drain the fuel filter & water separator ,filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the u/s brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, including M & L for V Belts, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load and record shall be made in respect of RPM , oil pressure ,oil temperature ,coolant temperature, voltage , frequency , load current , battery charging , fuel consumption etc complete all as specified and directed by Engineer in Charge for 100 KVA DG set.Make: Kirloskar. Details of DG sets: (a) 100 KVA DG Set
Note :- 1 (a). Engine oil for refilling will be measured and paid for separately (b). Coolant for make up will be measured & paid for separately (c). Testing will be carried out in presence of Engineer - in - charge and DHPP consumption will be entered in PRRB. (d). The Make of Fuel filter , Oil Filter , V belt & component will be as per manufactures recommendations ( Rate of fuel filter, oil filter, air filter and V belt shall deem to be included in quoted rate.)
(e) Charges for Major repairs / top overhauling of engine, rewinding of alternator, alternator major overhauling due to normal wear & tear will be out of scope of the work. However the damages caused due to negligence of the contractor will be made good without any extra cost by the contractor. Cost of minor spares required for proper operation of DG set and Control panel shall be deemed to be included in the rate quoted. (f) U/s spares shall be measured under Schedule of Credit.
Supply only multi-grade 15W40 lubricating oil for DG Sets as per manufacturer’s recommendations, complete all as specified and directed. Make- IOC, Castrol, Hindustan Petroleum
Supply only coolant for radiator as per manufacturer’s recommendations, complete all as specified and directed. Make- Castrol, Servo, Cummins
Supply only lubrication oil filter element with O ring of make MICCO/Kirloskar/Ruston as required at site for 100 KVA DG set all as directed by Engineer-In- Charge
Supply only fuel filter element with O ring of make MICCO/Kirloskar/Ruston as required at site for 100 KVA DG set all as directed by Engineer-In- Charge
Supply & fixing Water body,radiator system, with connecting accessories Hose pipe set , Clips of water / coolant cooled radiator system for 100 KVA DG set
Repairs & Overhauling of radiator assembly by dismantling from engine transporting to the workshop and removing the sediments and scales, corrosion etc by means of acid, cleaning and high pressure water washing and air cleaning, gas welding / soldering with good quality material for stopping the leakage etc, re-assembling the same with new gaskets and transporting to the site, fixing to the engine with hoses, clips complete to the entire satisfaction of engineer - in - charge as required for 100 KVA DG set.
Dismantling the water pump of the DG Set taking out the worn out parts, refixing the water pump in the same position after replacing the worn out parts with new water pump repair kit set for 100 KVA DG set.
Repairs to 12/24V self starter by removing, dismantling and taking it to authorised workshop and replacing unserviceable Armature including field coil tapping re-fixing to the engine testing for satisfactory function all as directed by Engineer-in-Charge
Removing and replacing the old unserviceable AVR (Automatic Voltage Regulator) suitable for Greaves Power cotton curve of capacity 100 to 250 KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hz complete all as directed by Engr-in-Charge. Make : Kirloskar / Cummins/Crompton Greaves.
Supply only Governor control cable inner and outer for the 100 KVA capacity DG Set complete all as specified and directed.
Supply only Solenoled shut off valve sup and fix new Solenoled shut off valve assembly complete suitable to operate with 12/24 volts DC
Supply only Lube oil pressure sensor for Engine complete all as specified and directed.
Supply only Push button switch for 100 KVA DG set complete all as specified and directed.
Supply only Ignition switch heavy duty with keys for 100 KVA DG set complete all as specified and directed.
Removing the silencer and replace with new gasket and manifold to arrest all exhaust leakage for Genset for 100 KVA DG set complete all as specified and directed.
Flexible over flow pipe steel armoured flexible with suitable end sockets of size 15 mm dia of suitable length and size for 100 KVA DG set complete all as specified and directed.
Supply and replacement of radiator hose of Diesel engine generating sets for 100 KVA DG set complete all as specified and directed.
Supply and repalcement of fule hose set nylon type for 100 KVA DG set complete all as specified and directed.
Supply and replacement of radiator fan belt for 100 KVA DG set complete all as specified and directed.
Supplya dn replacement of valve door packing for 100 KVA DG set complete all as specified and directed.
Supply and repalcement of turbo cooler rubber hose for 100 KVA DG set complete all as specified and directed.
Supply and replacement of controle unit for 100 KVA DG set complete all as specified and directed.
M&L for distilled water to be filled in batteries of any capacity complete all as directed by Engr-in-Charge
S& F in replacement of Contactor, 400 Amp, 3 pole,rated operational voltage <=690 Voltage AC 50 Hz, with rated making capacity of 4000 Amp at 440 Volt AC for power circuit conformoing to IEC 60947-4-1& rated breaking capacity 3200 A at 440 volt for power circuit conforming to IEC 60947, electrical durability 600000 cycles AC-13 complete all as specified and directed.
Dismatling and removing fuel injection pump (FIP) of capacity of 100 KVA DG Set and taking out it to authorised workshop and replacing unserviceable element, delivery valve, balance wait, lever, bearing after repairing fixing to the engine testing for satisfactory function all as directed by Engineer-in-Charge
Repairs to dynamo / alternator including removing from position remove the burntout armature , clean the internal surfaces , servicing, supply and fix new armature with brushes and brush holder , necessary lathe work with bushes etc all as directed
Disconnecting the existing battery of capacity 12V / 180 AH from the DG set, taking it to battery workshop, draining out the complete unserviceable electrolyte acid from the battery, filling up with new Electrolyte acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG set, start the engine for satisfactory function all as directed by Engineer-in-charge.
Repairs to 24 V battery charging alternator assembly by removing, dismantling, replacing the unserviceable burnt rotor and stator assembly, assembly reaffixing to the engine and testing for satisfactory charging of battery all as directed by Engineer-in-Charge.
Supply and fix in replacement of Dry cell tubular type 12 V , 180 AH and initial charging complete including inbuilt charger including required electrolite /distilled water etc and fixing as required at site to the concerned DG Set all as directed.Make : EXIDE
Painting of the 100 KVA capacity DG set after preparing the external surface, apply one coat of spray painting by superior quality enamel paint of appropriate colour for engine, alternator, connected panel, base frame, radiator, battery stand, and cleaning the meter panel writting of MES No etc all as directed.
Schedule of Credit (Minus) Rs. 114319.00 NOTE: Bidder shall insert credit amount of Rs. 114319.00 as rate in Green field under Col-5.
R.K. Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .