Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L1 | Accepted-AOC AOC being L1 | |
| 2 | L2₹25.7 L+₹62,024 (2.47%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹25.8 L+₹66,238 (2.64%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹26.2 L+₹1.1 L (4.32%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹26.7 L+₹1.6 L (6.48%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
14 Aug 2021, 6:00 pmClosed
GE I NAVY JAMNAGAR
INS NAVY VALSURA JAMNAGAR 361150
REPAIR REPLACEMENT AND MAINTENANCE OF WATER HEATERS SOLAR GEYSERS AND VENTILATION EQUIPMENT SUCH CEILING EXHAUST FANS ETC AND CONNECTED ITEMS UNDER GE I NAVY JAMNAGAR
2021_MES_461196_2
8529
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE I NAVY JAMNAGAR
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE I NAVY JAMNAGAR
₹50,000
Yes
2 Aug 2022
6 Aug 2021
16 Aug 2021
6 Aug 2021
14 Aug 2021
9 Aug 2021
6 Aug 2021 - 7 Aug 2021
Amount
Taking down carefully ceiling fans / exhaust fans from any height and of any make and sweep including disconnecting the cable from ceiling rose and deposited to MES store for servicing, greasing & oiling, replacing the split pin, unserviceable nut, bolt, etc. and refixing the same after servicing with necessary connection complete all as specified and as directed.
Taking out carefully unserviceable shaft bush and S&F new shaft bush of existing type / model for ceiling fans & exhaust fans complete all as specified and as directed.
Taking out carefully unserviceable ball bearing of any type/ size and S&F new ball bearing suitable for any type/ size ceiling fans & exhaust fans as per the existing standard complete all as specified and as directed.
Taking out existing unserviceable fan condenser/ capicitor of any size/ make and S&F connecting new fan condenser/ capacitor 2.0 to 2.5 mfd complete all as specified and as directed. Make: Usha/ Siemens
Taking out existing unserviceable fan condenser/ capicitor of any size/ make and S&F connecting new fan condenser/ capacitor 3.15/ 4.0 mfd complete all as specified and as directed. Make: Usha/ Siemens
S&F in repairs step type fan regulator 100 W, 2 module, AC, 230V, electronic complete all as specified and directed. Make: Legrand Cat No: 6755 30 / Indo Asian / Havells / Crabtree
S&F in repairs step type fan regulator AC, 230V, electronic on the existing phenolic laminated sheet etc complete all as specified and directed. Make: Anchor / Legrand / Havells / Crabtree / Indo Asian.
S&F in repairs step type fan regulator 100W, 1 module, AC, 230V, electronic complete all as specified and directed. Make: Legrand Cat No: 6755 31 / Indo Asian / Havells / Crabtree
Taking out carefully damaged/ worn out rubber real and S&F new rubber reel of existing size & shape complete all as specified and as directed.
Taking out carefully damaged/ worn out MS clamp and S&F new MS clamps with necessary nuts, bolts, washers, locking pins etc of existing size & shape complete all as specified and as directed.
Dismantling 1200 mm sweep ceiling fan motor of any make, removing old burnt winding wire, cleaning the armature throughty and replacing the sme with new enamelled copper wire of adequate size/gauge including class B insulation, varnishing heating etc, reassembling, resting refixing and connecting complete all as specified and as specified.
All as per Item No. 11 here in above, but for 1400 mm sweep ceiling fan motor.
All as per Item No. 11 here in above, but for 450 mm sweep exhaust fan motor.
All as per Item No. 11 here in above, but for 300 mm sweep exhaust fan motor.
All as per Item No. 11 here in above, but for 250 mm sweep exhaust fan motor.
S&F 450 mm sweep exhaust fans metal body AC single phase 230/240 V with lower shutter venti Air complete all as directed. Make: Bajaj Supreme Dlx 450mm 900 rpm 1ph Ind Ex fan or equivalent in USHA/ Khaitan/ Crompton Greaves
S&F 225 mm sweep exhaust fans metal body AC single phase 230/240 V with lower shutter venti Air complete all as directed. Make: Bajaj Freshee 250mm Metalic Grey Exhaust Fan or equivalent in USHA/ Khaitan/ Crompton Greaves
S&F 250 mm sweep exhaust fans PVC body AC single phase 230/240 V with lower shutter venti Air complete all as directed. Make: Bajaj Maxima DX Fresh Air 250 mm White Exhaust fan or equivalent in USHA/ Khaitan/ Crompton Greaves/ Havells
S&F 200 mm sweep exhaust fans PVC body AC single phase 230/240 V with lower shutter venti Air complete all as directed. Make: Bajaj Maxima DX Fresh Air 200mm White EX Fan or equivalent in USHA/ Khaitan/ Crompton Greaves/ Havells
S&F 1200 mm sweep, 3 Star Rating ceiling fans 230 V with all accessories suitable size for down rod complete all as directed. Make: Bajaj Sabse Tezz EE or equivalent in USHA/ Khaitan/ Crompton Greaves /Havells
M&L for DOs/Don't instructions for Electric geysers as per E-in-C's branch letter Instructions, printed on PVC plastic coated paper self adhesive shall be pasted on geyser.
Taking down geyser of any capacity, horizontal / vertical type after properly disconnecting from water supply lines i.e. inlet/outlet and electric supply connections and reconnecting/ refixing the same in original position after necessary repairing complete all as specified and as directed. Note: Repair works and Spare parts shall be measured and paid separately.
Taking out existing unserviceable flexible cable of any size S&F new copper flexible cable 3 core PVC insulated of size 40/0.0076 for geyser complete all as specified and as directed.
Taking out existing unserviceable indicator lamp and S&F new indicator lamp (Neon lamp) round / square in red / green / blue as required of standard make for geysers complete all as specified and as directed.
Taking out existing unserviceable thermostat switch of any model/ make and S&F thermostat switch of as per existing make/ model for 50/25 ltr capacity geysers complete all as specified and as directed.
Taking out existing unserviceable heating element and S&F new heating elements 1000 W capacity and neoprene rubber washer ISI marked for vertical/ horizontal type geysers of 50/25 Ltrs capacity complete all as specified and as directed.
All as per Item No. 26 above, here in but heating elements 1500 W capacity.
All as per Item No. 26 above, here in but heating elements 2000 W capacity.
All as per Item No. 26 above, here in but heating elements 3000 W capacity.
Taking out existing unserviceable PVC connection pipe and S&F new PVC connection pipe heavy duty size 15 mm dia, 450 mm long as per the site requirement length with brass adopter/ union washer both sides suitable for hot water supply complete all as specified and as directed.
Taking out existing unserviceable non return valve and S&F new 15 mm dia Non Return Valve, lSl marked for vertical / horizontal geysers complete all as specified and as directed
S&F in repairs plug top 3 pin, 15/ 16 Amps capacity, lSl marked complete all as specified and as directed.
Supply only 25 ltr storage capacity Electric water heater 5 star rating, glass liner inner tank, plastic outer body PUF insulation with 2kW heating element, operating on single phase, 230 V, AC supply complete all as specified. Make: Jaquar Elena Prime EPM WHT V025 / Bajaj Celenta Mechanical Model No. 150761 or equivalent in Recold / Havelles
S&F single pole enclosure with a two pin and earth plug and socket 240V with one single pole MCB 20Amp complete all as specified and as directed.
Taking down old existing sub main wiring and M&L for sub main wiring with 2 run single core 2.5 Sq.mm PVC insulated unsheathed copper multistranded conductor 1100 Volts grade drawing into and including PVC heavy duty casing and capping with PVC coated copper earth conductor 2.5 Sq.mm one run complete. Note: 2 run of 2.5 Sq.mm cable one run 2.5 Sq.mm PVC insulated cable copper multistranded conductor alongwith PVC cassing capping will be measured as one unit.
Taking out existing flow unit and S&F new flow unit/ siphon assembly including outlet and thermostat pipes with drain plug and screw for fixing the elements inclusive of clamps for holding the element with nuts & bolts complete all as specified and as directed.
Taking down solar water heater of any capacity, horizontal/ vertical type after properly disconnecting from water supply lines i.e. inlet/ outlet and electric supply connections and reconnecting/ refixing the same in original position after repair complete all as specified and as directed. Note: Repair work and spare parts shall be measured and paid separately.
M&L for servicing parts of TATA solar water heater of 100 Ltr capacity evacuated tube collector, make and model
M&L for servicing parts of TATA solar water heater of 200 / 300 Ltr capacity evacuated tube collector, make and model
M&L for servicing parts of TATA solar water heater of 100 / 300 Ltr capacity copper collector based chemical wash for collector, make and model
S&F Silicon rubber, O ring with coupler set for 100/200 Ltr capacity solar water heater
S&F CPVC pipe SDR 11 having outer dia 15 mm pipe with plain CPVC SDR 11 fitting such as bends, elbows, unions and end pieces to receive the fittings and fixed with solvent cement in walls/ceilings (concealed/surface) or laying in floors complete all as specified
All as per Item No.42 here in above, but 20 mm outer dia pipe.
All as per Item No.42 here in above, but 25 mm outer dia pipe.
S&F Evacuated Solar Tube of minimum size 1800 mm x 58 mm complete all as specified. Make: Tata BP solar or equivalent make
M&L for Mild steel angle Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated and inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paint complete all as specified.
S&F in repairs 20 mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends ISI marked for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repairs 25 mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends ISI marked for iron pipe or for unions and fixed complete all as specified and as directed.
M&L glass wool in 40-80 mm thick sheet yellow/ white colour, suitable for insulation of water heaters complete all as specified.
M&L for GI tubing 15 mm bore medium grade duly drilled with two Nos. of M8/M10 bolts of required length for hanging of ceiling fans complete all as specified.
Cutting opening, through RR masonry / brick walls for fixing exhaust fan of required size (Square/Round) up to 450 mm sweep and making good disturbed surfaces of wall of required size with CM 1:4 and painting with two coats of existing colour to match the wall complete all as specified and as directed.
M&L for hose pipe suitable for solar water heater of required 20mm size and as per required length at size
S&F in repairs louvers/ wire mesh bracket / PVC ready made Mesh to prevent bird entry suitable for 450mm sweep Exhaust fans.
All as per Item No. 53 above, here in above but for 300mm sweep Exhaust fans.
All as per Item No. 53 above, here in above but for 250mm sweep Exhaust fans.
S&F rubber anti vibrating shoes suitable for exhaust fans of 450mm sweep.
S&F capacitor clamp for ceiling fan.
S&F 600mm long down rod for ceiling fan.
S&F new canopy for ceiling fan. Make: Bajaj/ Usha/ Havells
Raj brothers
M/s.Bhavin Electricals
JAYESH TRADING CORPORATION
J J ENTERPRISE
Jyoti Refrigeration
ambika electric co
Rameshwar Enterprise
M/s Jagdish Machinery Stores
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .