Lt Col Vijay Singh GE
Garrison Engineer Naval Depot Industrial Estate Post 104 Area Visakhapatnam 530007
REPAIR MAINTENANCE OF INTERNAL WIRING AT INS DEGA AND INS EKSILA UNDER AGE EM OF GE ND VISAKHAPATNAM
2020_MES_366308_1
8896
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Visakhapatnam
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE ND Visakhapatnam
₹80,000
Yes
11 Nov 2020
4 Aug 2020
7 Sept 2020
4 Aug 2020
2 Sept 2020
19 Aug 2020
Amount
The rates quoted by the tenderer shall deemed to be inclusive for the following provisions in addition to the other conditions specified in the tender documents. No claim whatsoever shall be entertained at a later date on this account:- [i] The repairs shall be done by skilled workmen in the relevant field to the entire satisfaction of Engineer-in-Charge. The contractor shall engage sufficient manpower for the entire period so that progress of work shall not be hampered due to non availability of labour at any time. [ii] The contractor on getting information through Site order / Works diary regarding the nature of repair to be carried out, he shall immediately respond to the same and make all out efforts to carry out the same on priority within 48 hours. In case of any delay in responding / attending the repairs within 48 hours, the GE may at his absolute discretion impose penalty on the contractor at Rs. 100/- per day per each work ordered upto 05(Five) days and Rs. 200/- per day thereafter till completion of the work in case of delay without valid reasons as decided by GE. [iii] Further, the above penalty is applicable even for the multiple locations of work at the same period. It is the responsibility of contractor to make suitable arrangements for attending the repairs simultaneously at all the places. [iv] The decision of the GE as to whether a particular repair has been attended or not on a particular day will be final and binding. The above penalty shall be in addition to the provisions made in clause 50 of IAFW-2249 i.e (Compensation for delay in completion of work).
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including surface PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including modular box with plate, provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell / 5 Amps socket point controlled by one, one way switch including taking down old point wiring with fittings & fixtures complete all as specified and directed.
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 2.5 Sqmm (nominal area) 1100V grade drawn through and including surface PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including modular box with plate, provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 2.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for one power socket point on independent board including taking down old point wiring with fittings & fixtures complete all as specified and directed.
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 4.0 Sqmm (nominal area) 1100V grade drawn through and including surface PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including modular box with plate, provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 4.0 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for one power socket point on independent board including taking down old point wiring with fittings & fixtures complete all as specified and directed.
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including concealed PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including modular box with plate, provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell / 5 Amps socket point controlled by one, one way switch including taking down old point wiring with fittings & fixtures complete all as specified and directed.
M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 4.0 Sqmm (nominal area) 1100V grade drawn through and including concealed PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including modular box with plate, provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 4.0 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One power socket point on independent board including taking down old point wiring with fittings & fixtures complete all as specified and directed.
S & F modular switch single pole, 1 way, 6 Amps, 1 module
S & F modular switch single pole, 1 way, 16 Amps, 1 module
S & F modular socket outlet, 6 Amps, 2/3 pin combined 2 module
S & F modular socket outlet, 6/16 Amps, 2/3 pin combined 2 module
S & F modular electronic fan regulator, socket type, omplete all as specified and directed.
S & F ceiling rose, 3 terminals, PVC/ polycarbonate, isolated body complete all as specified and directed
S & F, Switch Piano, flush type, single pole, one way, 5 Amps, 230 Volt complete all as specified.
S & F, Switch Piano, flush type, single pole, Two way, 5 Amps, 230 Volt complete all as specified.
S & F switch socket combination multipurpose 3 pin, 5 Amps controlled by one 5 Amps switch complete all as specified and directed.
S & F switch socket combination, multipurpose, 2 in 1, 3 Pin, 5/15 Amps, flush type, universal controlled by one switch 15 Amps, 250 volts, complete all as specified and directed
S & F electronic fan regulator, socket type complete all as specified and directed.
S & F LED tube light fittings, retro bar professional WH 5700K to 6200K and minimum 1800 lumens of cool white comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F LED mirror light fittings, 2 feet long of minimum 700 lumens of cool white wall mounted batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F LED bulb non dimmable pin type 7 watts
S & F Square recessed mounted LED light (1'x1') of minimum 1800 Lumens with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F Square recessed mounted LED light (2'x2') of minimum 3600 Lumens with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F Highbay / Flood light 9000 Lumens (min) new generation LED with high luminous efficacy, IP65 protected, front toughened glass, energy saving with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F Highbay / Flood light 12000 Lumens (min) new generation LED with high luminous efficacy, IP65 protected, front toughened glass, energy saving with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F Highbay / Flood light 15000 Lumens (min) new generation LED with high luminous efficacy, IP65 protected, front toughened glass, energy saving with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F Building Security light LED type of minimum 2500 Lumens Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 40mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F 2mm thick GI hot dip galvanised / powder coated perforated type cable trays of size 100mm width, 25mm depth fixed with and including necessary MS clamps, nuts, bolts fixed to walls / ceiling including taking down old cable tray complete all as directed by the Engineer-in-Charge.
S & F 2mm thick GI hot dip galvanised / powder coated perforated type cable trays of size 75mm width, 50mm depth fixed with and including necessary MS clamps, nuts, bolts fixed to walls / ceiling including taking down old cable tray complete all as directed by the Engineer-in-Charge.
S & F 2mm thick GI hot dip galvanised / powder coated perforated type cable trays of size 100mm width, 50mm depth fixed with and including necessary MS clamps, nuts, bolts fixed to walls / ceiling including taking down old cable tray complete all as directed by the Engineer-in-Charge.
S & F PVC cable tray of size 105mm width, 50mm depth fixed with and including necessary MS clamps, nuts, bolts fixed to walls / ceiling including taking down old cable traycomplete all as directed by the Engineer-in-Charge.
S & F PVC cable tray of size 80mm width, 50mm depth fixed with and including necessary MS clamps, nuts, bolts fixed to walls / ceiling complete all as directed by the Engineer-in-Charge.
M & L for preparation of old painted steel surfaces of any description such as external surfaces of LT panels, etc over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specifried
S & F in repairs GI powder coated louvers suitable for exhaust fans 300mm sweep including replacing copper conductor wire complete all as directed. [Note: Quoted rate is deemed to be inclusive for necessary scaffolding as required for work at any height]
S & F in repairs GI powder coated louvers suitable for exhaust fans 600mm sweep including replacing copper conductor wire complete all as directed. [Note: Quoted rate is deemed to be inclusive for necessary scaffolding as required for work at any height]
Taking down existing ceiling fan of any type and sweep from any position and refixing the same in original position after necessary cleaning for dust, grease and applying one coat of synthetic enamel paint (spray painting) including filling the cavities with filler complete all as specified and directed by the Engineer-in-Charge. [Note: Quoted rate is deemed to be inclusive for writing MES Nos on the fans
M & L for removing defective / burnt out winding of ceiling fans of any capacity and rewinding with super enamelled copper winding wire of suitable size complete all as specified and directed by the Engineer-in-Charge.
Supply and replacement of bearing suitable for ceiling fans of any sweep
Supply and replacement of 2.5 mfd suitable for ceiling fans of any sweep
Supply and replacement of fan clamp with rubber bush and nuts & bolts suitable for ceiling fans of any sweep
Taking down existing exhaust fan of any type and sweep from any position and refixing the same in original position after necessary cleaning for dust, grease and applying one coat of synthetic enamel paint (spray painting) including filling the cavities with filler complete all as specified and directed by the Engineer-in-Charge. [Note: Quoted rate is deemed to be inclusive for writing MES Nos on the fans]
M & L for removing defective / burnt out winding of exhaust fans of any capacity and rewinding with super enamelled copper winding wire of suitable size complete all as specified and directed by the Engineer-in-Charge.
Supply and replacement of bearing suitable for exhaust fans of any sweep
Supply and replacement of 6 mfd suitable for exhaust fans of any sweep
Taking down existing Air circulator / Pedestal fan of any type and sweep from any position and refixing the same in new / old position after necessary over hauling / servicing and cleaning for dust, grease and applying one coat of synthetic enamel paint (spray painting) including filling the cavities with filler including replacement of defective spares complete all as specified and directed by the Engineer-in-Charge. [Note: Quoted rate is deemed to be inclusive for writing MES Nos on the fans]
Supply and replacement of twin core 1.5 Sqmm flexible copper conductor from ceiling rose to fan complete all as directed
S & F in repairs Star delta starter suitable for 7.5 HP motor with TPN isolator control to run hanger door complete all as directed
S & F in repairs Wall mounted AC distribution box (Industrial socket) including plug and socket of 16 Amps, 2 pole and earth, IP 40 protection of metal body single phase 240 Volts, 50 Hz with provision for one 16 Amps MCB 2P including necessary fixing arrangements complete all as directed by the Engineer-in-Charge.
S & F in repairs Wall mounted AC distribution box (Industrial socket) including plug and socket of 32 Amps, 3 pole, neutral and earth, IP 40 protection of metal body three phase 415 Volts, 50 Hz with provision for one 32 Amps MCB TPN including necessary fixing arrangements complete all as directed by the Engineer-in-Charge.
S & F in repairs Wall mounted AC distribution box (Industrial socket) including plug and socket of 63 Amps, 3 pole, neutral and earth, IP 40 protection of metal body three phase 415 Volts, 50 Hz with provision for one 63 Amps MCB TPN including necessary fixing arrangements complete all as directed by the Engineer-in-Charge.
S & F in repairs MCCB 4 Pole, 63 Amps, 50 Hz, 25KA, 415 Volts with all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCCB 4 Pole, 100 Amps, 50 Hz, 25KA, 415 Volts with all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCCB 4 Pole, 125 Amps, 50 Hz, 25KA, 415 Volts with all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCCB 4 Pole, 250 Amps, 50 Hz, 25KA, 415 Volts with all necessary aluminium lugs and glands, etc complete all as directed
S & F in repairs MCB DB, Vertical TPN, 8 way, double door, 415 Volts with 200 Amps rated bus bar suitable for incomer TPN MCCB with all necessary wiring connection and making good disturbed surfaces of wall complete all as specified and directed.
S & F in repairs MCB DB, horizontal SPN, 8 way, double door, 240 Volts with 200 Amps rated bus bar with all necessary wiring connection and making good disturbed surfaces of wall to match with adjoining finishes complete all as specified and directed.
S & F in repairs MCB DB, horizontal SPN, 12 way, double door, 240 Volts with 200 Amps rated bus bar with all necessary wiring connection and making good disturbed surfaces of wall to match with adjoining finishes complete all as specified and directed.
S & F in repairs MCB DB, TPN, 4 way, double door, 240 Volts with 200 Amps rated bus bar with all necessary wiring connection and making good disturbed surfaces of wall to match with adjoining finishes complete all as specified and directed.
S & F in repairs MCB DB, TPN, 8 way, double door, 240 Volts with 200 Amps rated bus bar with all necessary wiring connection and making good disturbed surfaces of wall to match with adjoining finishes complete all as specified and directed.
S & F in repairs MCB, TPN, 63 Amps
S & F in repairs MCB, TPN, 100 Amps
S & F in repairs MCB, TSPN, 40 Amps
S & F in repairs MCB, SP, 6 to 32 Amps
S & F in repairs RCB, DP, 40 Amps
S & F in repairs RCB, FP, 63 Amps
S & F in repairs sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete all as specified and directed.
M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 4.0 Sqmm, drawn through and including suitable size PVC conduit and conduit accessories including provision of 1 run of 4.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified and directed. [NOTE: 3 runs of 4.0 Sqmm copper wire and 1 run of PVC conduit shall be measured as one unit length.]
M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 6.0 Sqmm, drawn through and including suitable size PVC conduit and conduit accessories including provision of 1 run of 6.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified and directed. [NOTE: 3 runs of 6.0 Sqmm copper wire and 1 run of PVC conduit shall be measured as one unit length.]
M & L for sub main wiring with 4 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 10.0 Sqmm, drawn through and including suitable size PVC conduit and conduit accessories including provision of 1 run of 10.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified and directed. [NOTE: 5 runs of 10.0 Sqmm copper wire and 1 run of PVC conduit shall be measured as one unit length.]
S & F in replacement of flame proof switch rotary type with terminal box in LM6 single pole 250 volts complete all as directed
S & F in replacement of flame proof junction box with plain cover 3/4" ET 80 complete all as directed
S & F in replacement of flame proof switch socket & plug combined in LM6 cable termination box of 16 Amps, 250 Volts, 3 pin 5 and 3 pin 16 Amps rotary type with termination complete all as directed
S & F in repairs Earth continuity conductor or main earthing lead of 32x6mm GI strip fixed to wall on batten or recess or cases or buried in ground or drawn in conduit / pipe or fixed to poles complete all as specified.
S & F in repairs Aluminium strip 25x3.15mm as roof conductors and down conductors buried in ground / fixed on wall with epoxy based insulator and screws, bolts, nuts and lead washers complete all as specified and directed.
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 4 core 10 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / fixed on walls including taking down old cable complete all as specified and directed.
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 4 core 16 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / fixed on walls including taking down old cable complete all as specified and directed.
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 4 core 25 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / fixed on walls including taking down old cable complete all as specified and directed.
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 3.5 core 35 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / fixed on walls including taking down old cable complete all as specified and directed.
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 3.5 core 70 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / fixed on walls including taking down old cable complete all as specified and directed.
Supply, laying and testing XLPE insulated, PVC sheathed bedded unarmoured electric power cables [heavy duty] with stranded copper conductor 1100 Volt of size 2 Core 6 Sqmm including taking down old copper cable complete all as directed.
Supply, laying and testing XLPE insulated, PVC sheathed bedded unarmoured electric power cables [heavy duty] with stranded copper conductor 1100 Volt of size 4 Core 6 Sqmm including taking down old copper cable complete all as directed.
Supply, laying and testing XLPE insulated, PVC sheathed bedded unarmoured electric power cables [heavy duty] with stranded copper conductor 1100 Volt of size 2 Core 10 Sqmm including taking down old copper cable complete all as directed.
Supply, laying and testing XLPE insulated, PVC sheathed bedded unarmoured electric power cables [heavy duty] with stranded copper conductor 1100 Volt of size 2 Core 16 Sqmm including taking down old copper cable complete all as directed.
Earthing complete with Copper plate electrode of size 600x600x3.15mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to Copper earth strip 25x3mm by means of bolts, nuts, check nuts and washers all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, cast iron cover, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 32mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected to GI earth strip 32x6mm by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, cast iron cover, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 40mm dia, earthing lead upto 7.5m complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
M & L for Chemical earthing by drilling of hole upto 150mm dia to a depth not less than 3.0m and fixed sealed maintenance free chemical filled earthing electrode 48mm dia and 2.0m long product code AKE0248 of make ALFRREDKIM made up of copper buried directly and vertically in the hole with top edge not less than 1.25m below normal ground level connected with copper earth strip 30x6mm by means of bolts, nuts, check nuts and washers of copper connected to earthing test point all as specified or indicated including testing on ompletion and as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, refilling the earthing hole including earthing lead upto 7.5m complete all as specified in SSR Part-I and all as per manufacturers instructions.]
SAI POWER SYSTEMS
R AND A ASSOCIATES ENGINEERS CONTRACTORS
M/s Balaji Enterprises
MANIMADHAVI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .