Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹11.5 L+₹3,723 (0.32%)Rejected-AOC | L2 | Rejected-AOC Second lowest | |
| 3 | L3₹11.6 L+₹14,075 (1.23%)Rejected-AOC | L3 | Rejected-AOC Third lowest | |
| 4 | L4₹11.8 L+₹34,200 (2.98%)Rejected-AOC | L4 | Rejected-AOC Fourth lowest | |
| 5 | L5₹12.4 L+₹93,475 (8.15%)Rejected-AOC 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-AOC Fifth lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
16 Dec 2019, 6:00 pmClosed
GE Palampur
Holta Camp Palampur Kangra (H.P)
REPAIR MAINTENANCE AND REPLACEMENT OF SECURITY LIGHTS AND OTHER MISC EM WORKS AT PALAMPUR MIL STN
2019_MES_297219_1
GEP-47(Token)/2019-20
Open Tender
Civil Works
Item Rate
180 days
Palampur
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹30,000
Yes
21 Jan 2020
13 Nov 2019
17 Dec 2019
13 Nov 2019
16 Dec 2019
27 Nov 2019
Amount
Taking down the old unserviceable and high energy consuming HPSV/MH/4x14W Street Light fittings of any make or any capacity from the pole of 9/11 Mtr after disconnecting the electric connection carefully complete all as directed.
S&F energy efficient 45W LED street light fixtures with sufficient number of LEDs, control gear and all other associated accessories and colour temperature more than 6500 ºK and conforming to the degree of protection IP - 66 suitable for pole dia Ø 35/40 mm on existing poles complete all as specified and directed.
S&F energy efficient 60W LED street light fixtures with sufficient number of LEDs, control gear and all other associated accessories and colour temperature more than 6500 ºK and conforming to the degree of protection IP - 66 suitable for pole dia Ø 35/40 mm on existing poles complete all as specified and directed.
S&F LED flood light fitting 50W with sufficient number of LEDs, control gear and all other associated accessories and colour temperature more than 6500 ºK and conforming to the degree of protection IP - 66 complete all as specified and directed.
S&F LED flood light fitting 200W with sufficient number of LEDs, control gear and all other associated accessories and colour temperature more than 6500 ºK and conforming to the degree of protection IP - 66 complete all as specified and directed.
Refixing only old fittings after checking the serviceability and replacing the necessary unserviceable parts like CFL, Tube Rod, ignitor, choke, capacitor, lamps, wiring etc and reconnecting and testing, complete all as specified and directed. Note:- (i) Necessary parts like CFL, Tube Rod, ignitor, choke, capacitor, lamps will be measured and paid separately. (ii) The unit rate shall also include repairs to U/S wiring, Holder of any type and size, conductors at pole junction boxes / connecting from OH lines to light fittings, minor spares like, screws washers etc completely. Servicing, repair and fixing HPSV/MH/4x14W street light fittings of any make or any capacity taken down under Item Srl No. 1 above at another location carefully where required all as specified and directed.
Taking down old unserviceable post top lantern any type/size, supply and fixing 30W LED Post Top lantern with die cast aluminium spigot and lid cover, high efficient LEDs and clear acrylic cover IP65 complete all as specified and directed.
M&L for fabrication of street light bracket made out of GI pipe 40mm dia medium grade GI Pipe minimum 1.5 Mtr long including fixing with 02 Nos MS clamps made out of flat iron of size 40mm x 6 mm with nut bolts and washer complete all as specified and directed.
S&F eloctronic ballast suitable for energy conservation T5 Lamp road way lightining luminaries of capacity 4x14 watt with for plate fitting complete all as specified and directed.
S&F tube light rod suitable for energy conservation T5 Lamp road way lightining luminaries of capacity 14 watt with for plate fitting complete all as specified and directed.
S&F eloctronic ballast suitable for energy conservation T5 Lamp road way lightining luminaries of capacity 4x24 watt with for plate fitting complete all as specified and directed.
S&F tube light rod suitable for energy conservation T 5 Lamp road way lightining luminaries of capacity 24 watt with for plate fitting complete all as specified and directed.
Supply and fix street light box of PVC make sintex consisting of 01 No MCB 10 Amps, 10 KA capacity (SPN) including aluminium strip bus bar for incoming and outgoing cable with necessary connection duly fixed on the pole with suitable size of MS clamp as approved and directed.
Dismantling/taking out old defective cable form street light poles (Junction box to fitting) and supply and fix 4 Sqmm two core copper conductor multistranded including PVC conduit on poles or passing through steel or PVC conduit pipe 1100 volts grade with suitable cable lugs, clamps, nut bolts etc complete all as specified and directed.
Material and labour for servicing of high mast light including of oiling greasing of wire rope and driving motor complete all as directed.
Supply & fixing in replacement with wiring from connector to high mast light with suitable size of twin core copper wire including replacement of unserviceable connector complete all as directed.
Supply & fixing in replacement with wire rope of high mast light with clamp, nut & bolt including taking down high mast light with hydro machine complete all as directed.
Supply & fixing in replacement with 20 Watt LED Bulb complete all as specified and directed.
Supply & fixing in replacement with PVC LT line separators 4/5 way, complete all as specified and directed.
Supply & fixing in replacement with PVC LT line separators 2/3 way, complete all as specified and directed.
Supplying and fixing in replacement of PCC pole by erecting truly to vertical position steel tubular swaged pole complete with cast iron base plate welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9 metre long) including one coat of red-oxide zinc chrome primer and two coats aluminium paint on surfaces, exposed to view and making 30cm wide strips (Total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including with writing of pole No with letters/ figures of size not exc 30 mm with black paint on a yellow circle of dia 75 mm after painting, complete all as specified and directed. Note: PCC, earth work shall be measured and paid separately under respective items.
Painting to existing steel tubular LT poles/street light poles, 9 metres long including cross arms, channels, angle iron support, bracing, clamps etc with two coats of aluminium paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surfaces above PCC benching including preparation of old painted surfaces by scraping etc complete and writing of pole No with letters/ figures of size not exc 30 mm with black paint on a yellow circle of dia 75 mm after painting, complete all as specified and directed.
Supply & fixing in replacement with shackle type insulator porcelain vitreous white, brown or green 75 mm high and 90 mm dia for conductor of working pressure 1100 volts including galvanised mild steel straps of 31 x 3mm size, 12mm dia insulator bolts, washers and nuts, complete all as specified and directed.
1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hungers not more that 1m apart including 4mm dia suspension GI wire with stranded conductor 10 Sqmm twin core cable flat or circular including taking down taking down old unserviceable cable and stacking at site, complete all as specified and directed.
Taking out existing unserviceable LT XLPE cable of any type/any size and replacing of XLPE insulated electric power cables with 10 sqmm 2 core aluminium conductor served with an inner sheathing of armoured with galvanized steel wire or tape (heavy duty) of rating 1100 volts grade in trenches or passing through pipes/ducts or fixing to walls/poles etc, complete all as specified and directed.
Taking out existing unserviceable LT XLPE cable of any type/any size and replacing of XLPE insulated electric power cables with 16 sqmm 2 core aluminium conductor served with an inner sheathing of armoured with galvanized steel wire or tape (heavy duty) of rating 1100 volts grade in trenches or passing through pipes/ducts or fixing to walls/poles etc, complete all as specified and directed.
Taking out existing unserviceable LT XLPE cable of any type/any size and replacing of XLPE insulated electric power cables with 10 sqmm 4 core aluminium conductor served with an inner sheathing of armoured with galvanized steel wire or tape (heavy duty) of rating 1100 volts grade in trenches or passing through pipes/ducts or fixing to walls/poles etc, complete all as specified and directed.
Taking out existing unserviceable LT XLPE cable of any type/any size and replacing of XLPE insulated electric power cables with 16 sqmm 4 core aluminium conductor served with an inner sheathing of armoured with galvanized steel wire or tape (heavy duty) of rating 1100 volts grade in trenches or passing through pipes/ducts or fixing to walls/poles etc, complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and exceeding 1.5m in depth for foundation, and getting out in any type of soil, complete all as specified and as directed.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and directed.
Removal of excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
Sub class 'B' brick, old size, as cable protection cover, laid dry, flat transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Sand cushioning to under ground cable with a layer of sand 8cm before laying the cable and 15cm after laying the cable (10cm punned thickness above the top of the upper most cable, total 23cm), complete all as specified and directed.
M&L plain cement concrete 1:3:6 type C2 using 40 mm graded crushed stone aggregate for foundation of poles/struts/stay etc.complete all as specified and directed.
M&L plain cement concrete (1:3:6) type C1 using 20 mm graded crushed stone aggregates for pedestal of poles, all including necessary form work, fair finishing to the exposed surfaces using extra cement complete all as specified and directed.
S&F timelite Distribution Board 32 Amp, 3 pole, 230 V, 50 Hz with Astronomical time switch according to IEC 60730-1 with text based programming concept. The time switch should be microprocessor based programmable having 2 channels and should work on the principle of daily calculations of sunrise and sunset calculations by programming the date, time and positioning coordinates (Longitude and Latitude). The switching ON and switching OFF times should be adjustable asymmetrically for ±120 Minutes (Offset) complete all as specified and directed.
S&F MCCB 63 amps rupturing capacity 16 KA 4 pole 415 volts AC with fixed thermal magnetic release including taking out old unserviceable MCCB of any capacity and store in safe custody for credit complete all as specified and directed.
S&F MCCB 100 amps rupturing capacity 25 KA 4 pole 415 volts AC with adjustable thermal and adjustable magnetic setting including taking out old unserviceable MCCB of any capacity and store in safe custody for credit complete all as specified and directed.
S&F MCCB 125 amps rupturing capacity 25 KA 4 pole 415 volts AC with adjustable thermal and adjustable magnetic setting including taking out old unserviceable MCCB of any capacity and store in safe custody for credit complete all as specified and directed.
Supply & replacement driver/electronic control gear suitable for 45 W LED street light fitting of any make as per site requirement complete all as specified and directed.
Material and labour for earthing with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr deep below normal ground level, connected to 4mm dia galvanized iron wire as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel complete with 15mm dia light grade protection pipe, 20mm dia GI light grade watering pipe with funnel including char coal dust, salt, PCC 1:2:4 in pit with precast RCC M-15 cover reinforced with XPM not less then 4.00 Kg per sqm including necessary earth work in any type of soil, removal of surplus soil to a distance not exc 50m, returning filling in complete as shown in electrical plate No 3 of SSR Part-I (2009), and connected to earthing test point all as specified or indicated, including testing on completion. Note: The rates for earthing includes the cost of earth lead and protection pipe upto 7.50m length.
ranbir singh and Co Govt Contractor and Transporter
BHARDWAJ BUILDERS
M/S MALHI CONSTRUCTIONS
malghotra construction co
M/S ASHWANI KUMAR AND COMPANY
M/S RS KAUSHAL
B S Ranbir and Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .