Loading…
Loading…
| # | Company | Amount | Rank |
|---|---|---|---|
| 1 | L1₹2.1 Cr | ₹2.1 Cr | L1 |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
15 May 2026, 5:30 pmClosed
MR Rajendra nayak
NAGAR PANCHAYAT UTAI
Construction of Indoor Stadium at Ward 01 in Umarpoti Road
190201
NIT NO: / 205 / PWD/2026 UTAI, Dated 04 / 05 /2026
RESTRICTED TENDER
WORKS
PERCENTAGE
18 days
NAGAR PANCHAYAT UTAI
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
14 documents required · 14 mandatory
Urban Administration and Development Department (UADD)
WORKS
MR Rajendra nayak
RESTRICTED TENDER
PERCENTAGE
A B C
NAGAR PANCHAYAT UTAI
TENDER SECTION
NAGAR PANCHAYAT UTAI
180
18
No
1
190201
15 May, 2026 5:30:00 PM IST
19 May, 2026 4:00:00 PM IST
5 May, 2026 10:30:00 AM IST
NIT NO: / 205 / PWD/2026 UTAI, Dated 04 / 05 /2026
Construction of Indoor Stadium at Ward 01 in Umarpoti Road
142000.00 INR
Fixed Deposit Receipt (OFFLINE)
2
19 May, 2026 3:00:00 PM IST
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
10d 16h 55m
14 documents required · 10 mandatory · 4 optional
₹0
₹1.4 L
15 May 2026
5 May 2026
19 May 2026
5 May 2026
15 May 2026
5 May 2026
19 May 2026
NAGAR PANCHAYAT UTAI
PROPOSED CONSTRUCTION OF INDOOR STADIUM AT - UTAI (C.G.)
BILL OF QUANTITY
Sno Code Particulars No L B H/D Qty Unit
1 1.2 Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).
Total 3764.00 Sqm
2 1.1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
total 663.37 cum
3 1.6 Extra for every additional lift of 1.5 m or part thereof
total 63.61 cum
4 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
Total 283.00 cum
5 3.3 Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work.
3.3.1 M-20 Grade
RCC WORK IN SUPERSTRUCTURE
TOTAL 143.51 cum
6 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 1 143.51
TOTAL 143.51 cum
7 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:
3.12.1 Thermo-Mechanically treated bars FE 415 94.35 0.007 7850
TOTAL 26008.27 kg
8 4.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom, kitchen etc., by applying cement slurry mixed with water proofing cement compound consisting of following applications including surface preparation: i) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. ii) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound@ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
total 34.00 sqm
9 4.13 Grading roof for water proofing treatment with:
4.13.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
10 2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level
total 1005.27 sqm
2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape
total 752.03 sqm
2.1.6 Columns, beams & walls- circular or any other geometrical shape other than square and rectangular in all sizes
total 227.18 sqm
2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
total 109.53 sqm
2.1.8 Beams, lintels, cantilevers & walls
total 459.313 sqm
2.1.15 Stair cases of all types excluding spiral and folded plate type, including risers and landings
total 77.20 sqm
11 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
total 650.52 cum
12 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:
7.5. 4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
total 46.07 cum
13 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:
7.5 & 7.6 extra for brick work in wall superstructure
net total 162.61 cum
14 7.11 Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level:
7.11.1 Cement Mortar 1:4 (1 cement : 4 coarse sand)
total 83.55 sqm
15 7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level: As per item No.14 83.55 sqm
16 7.2 Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry. As per item No.14 83.55 sqm
17 8.1 Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position.
8.1.2 Sal, bijasal, benteak, khair, haldu
18 8.14 Providing and fixing flush door shutters, core of block board construction with frame of first class hard wood and well matched first class Indian teak ply veneering on one face and commercial ply veneering on the other face of the shutter with vertical grains, cross bands and face veneering excluding hinges.
8.14.2 35 mm. thick (single leaf)
11 total 29.91 sqm
19 8.148 Providing and fixing factory made UPVC door frame made of UPVC profile section having an overall dimension as below (tolerance ± 1mm) with wall thickness 2.0mm ± 0.2mm, corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm ± 0.1mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge
8.148.2 Extruded section Profile size 42x50 mm.Door D3 8 5 40 m
20 8.150 Providing and fixing factory made 25mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762mm X 25mm or less as per requirement with an average wall thickness of 1mm ± 0.3mm. PVC foam end cap of size 23x10mm are provided on both vertical edges to ensure the overall thickness of 25mm. An M.S. tube having dimensions 19mm x 19mm is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25mm X 11mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufactures' specification.
21 9.47 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately:
1 #REF! 2 kg 445.8 kg
9.47.2 For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
1 #REF! 2 kg 445.8 kg
22 9.48 Extra for powder coated (minimum 50 micron) aluminium sections instead of anodized. 445.8 + 445.8 891.6 kg
23 9.51 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item):
9.51.2 With float glass panes of 5 mm thickness
total 69.57 sqm
24 9.54 Providing and fixing anodized aluminium framed grill (minimum anodic coating of grade AC 15)of of approved shape, pattern and design including cutting, bending, hoisting and erecting/ fixing to door, window frame or to wall with fixing clips or hold fasteners or bolts and nuts as required etc. complete.
1 #REF! 8 kg/rm 1243.2 kg
25 9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
26 8.59 Providing and fixing bright finished brass parliamentary hinges with brass polished MS screws complete:
27 8.10 Providing and fixing M.S. bright finished or black enameled door latch with necessary iron screws:
28 8.99 Providing and fixing M.S. bright finished or black enameled sliding door bolts with bolts, nuts and necessary iron screws:
29 8.102 Providing and fixing M.S. bright finished or black enameled Tower bolts (Barrel type) with necessary iron screws:
30 8.103 Providing and fixing M.S. bright finished or black enameled handles with necessary iron screws:
31 8.3 Providing 40x5mm iron hold fast 40cm long including fixing to frame with 10mm bolts nuts and wooden plug and embedding in Cement Concrete 1:2:4 in blocks of size 30x10x15cm. 11 6 66 each
32 8.103 Providing and fixing M.S. bright finished or black enameled handles with necessary iron screws:
33 11.1 &11.1.2 Providing and making 6mm thick cement plaster of mix:
In Cement mortar 1:4 (1 cement : 4 fine sand)
total 838.72 sqm
34 11.2 Providing and making 12mm thick cement plaster of mix:
net total 1207.25 sqm
35 11.2 Providing and making 6mm thick cement plaster of mix:
11.2.32 In Cement Mortar 1:5 (1 cement : 5 fine sand)
net total 874.61 sqm
36 11.12 Extra for plastering on circular work not exceeding 6.0 meters in radius.
37 11.9 Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer As per item No.38 874.61 kg
38 11.41 Providing and fixing chicken mesh weighting not less than 250 gms/ sqm as per IS : specification in the required width with 40mm long steel nails on vertical and horizontal surface near R.C.C. and brick walls junctions including scaffolding and all lead and lifts etc. complete before plastering upto 10mts in height. As per item No.38x25% 218.65 sqm
39 12.13 Providing and laying vitrified floor tiles with double charge/ multi charge printing with water absorption less than 0.5% and conforming to IS : 15622 of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.
12.13.1 Size 600x600mm
total 49.21 sqm
40 12.45 15 mm thick Table rubbed polished Granite stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above)
12.45.1 Granite stone grey/pink
net total 110.13 sqm
41 12.46 15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m).
42 13.17 Providing and fixing 15mm thick Granite (machine cut, table rubbed & mirror polished on both sides) for partition curtain in toilets or similar locations of required size in wall with cement mortar 1:4 (1 cement : 4 coarse sand) including cutting chase in wall and joint with wall treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish.
13.17.1 Granite stone grey/pink 6 0.6 1.2 4.32 sqm
43 12.9 Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.
12.9.1 Size 300x300mm
total 26.13 sqm
44 12.7 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete.
12.7.1 Size upto 200x300mm
net total 82.80 sqm
45 12.16 Extra for fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477 (Type 1) for interior applications, using 5kg. adhesive per sqm of tile area, in 3mm-6mm thickness in place of cement mortar. As per item No.42,46 & 47
46 14.13 Providing and applying 2mm thick ready mix exterior grade approved make putty (like Birla wall care, Alltek Superfine W/R of (NCL), Asian, ICI, Nerolac, J.K. wall putty) on walls to make the surface smooth and even.
total 3021.81 sqm
47 14.10 Wall painting with acrylic premium emulsion (plastic) paint of required shade to give an even shade.
total 2045.97 sqm
48 14.16 Painting exterior surface with PREMIUM ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with:
14.16.1 On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
49 14.22 Painting on new work (two or more coats) to give an even shade with:
14.22.2 Satin synthetic enamel paint
total 247.66 sqm
50 9.3 Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.
#REF! 38 kg/sqm 5672.86 kg
51 10.61 Providing and fixing at all height false ceiling consisting of frame work "W" / "U" / "L" sections made of G.I. sheet with zinc coating of grade 120 consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.55mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including
jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed including providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part-I all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting
52 12.69 38 mm thick parquet (wood blocks) flooring of teak wood laid over 25mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm nominal size) to be paid separately coated with thin layer of hot bitumen (blown type) @ 2.45 kg/ sqm including fixing blocks after dipping in hot bitumen (blown type) upto half depth planned, leveled, smooth and finished complete.
sports hall 2 17 9 306 Sqm
53 12.7 Extra for plaining the lower surface of wooden planking As per item No.52
54 10.12 Supply and fixing of polymer precoated galvalume profile sheets (PPGL) of approved size, shape and pitch of corrugation, total coated thickness (TCT) 0.60 mm +/- 5%, epoxy primer on both side of the sheet and colour polyester top coat 18-20 microns and 6-7 microns on bottom. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
55 10.16 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete :
10.16.1 Ridges plain (500-600mm) 1 24.18 24.18 rm
10.16.6 Gutter. (600 mm over all girth). 2 24.18 48.36 rm
56 11.3 15mm thick cement plaster on the rough side of single or half brick wall of mix: 924.00 SQM
57 14.6 White washing with whiting to give an even shade. 924.00 SQM
58 Distempering with acrylic washable distemper to give an even shade. 924.00 SQM
On new work (Two or more coats)
59 1.4 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared 500.00 Sqm
60 22.1 Trenching in ordinary soil upto a depth of 60cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly leveling with in a lead of 50m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 200.00 cum
61 22.2 Supplying and stacking of good earth at site including royalty, loading, unloading and carriage upto 5 km (earth measured in stacks will be reduced by 20% for payment). 200.00 cum
62 22.4 Supplying and stacking at site well decayed cow dung manure from approved source, including loading, unloading and carriage upto 5 km (manure measured in stacks will be reduced by 8% for payment). 50.00 cum
63 22.6 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. 500.00 Sqm
64 22.7 Fine dressing the ground 500.00 Sqm
65 22.8 Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/ and good earth to be paid separately). 250.00 cum
66 22.9 Mixing earth and sludge or manure in proportion specified or directed. 250.00 cum
67 22.10 Grassing with ‘Doob’ grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed (the good earth shall be paid for separately). 1000.00 Sqm
68 22.14 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : 501.00 each
69 22.25 Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil andsand:
22.25.1 Hedges like Alife, Dorenta, Tikoma etc 1500.00 Each
22.25.2 Furn like Arica , china etc (3 year old) 1500.00 Each
22.25.3 Hibiscus (Flower)/ Rose 1200.00 Each
22.25.4 Carpet grass (well developed) 1193.00 Sqm
70 22.16 Providing and fixing M.S. flat iron tree guard 60cm dia. and 2m height above ground level formed of 4 nos. 25x6mm and 8 nos. 25x3mm vertical M.S. flats riveted to 3 nos. 25x6mm M.S. flat iron rings in two halves, bolted together with 8mm dia. and 30mm long bolts including painting two coats with paint of approved brand and manufacture over a coat of priming, complete in all respects. 40.00 each
71 9.3 Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer. 4500.00 KG
72 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). 16.88 cum
73 7.5.4 In Cement mortar 1:3 (1 cement : 3 fine sand) 4.00 Sqm
74 11.2 12mm thick cement plaster of mix:
11.2.4 In Cement Mortar 1:6 (1 cement : 6 fine sand) 9.60 Sqm
75 14.14 Finishing walls with water proofing cement paint to give an even shade. 9.60 Sqm
76 12.6 Palm tree 40.00 each
77 12.14 Cement art Mural work 385.00 SQM.
78 21.1 Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by itable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge upto 90 metre depth below ground level. 15.00 Rmt
79 21.1.2 Rocky strata including Boulders. 45.00 Rmt
80 21.2 Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants &
machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level. 15.00 Rmt
81 21.3 Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe ofrequired dia,conforming to IS: 12818, including required hire and labour charges,fittings & accessories etc. all complete, for alldepths, as per direction of Engineer –in-charge. 27.50 Rmt
82 21.10 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully
developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw downetc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete,including hire& labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge 5.00 hour
83 21.11 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 1.00 each
84 21.17 Carrying out the resistivity survey by VES method using Schlumberger configuration for locating the proper spot for drilling of tubewell within the selected habitation, including photography, interpretation of resistivity data and submission of report in the desired format along with resistivity readings, necessary graph and photographs. (only successful point is payable 1.00 each
85 10.7 Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete: 45.00 Rmt
86 23.3 Supplying, installation, testing and commissioning of submersible pump set for water supply system with submersible motor directly coupled to multi-stage submersible pump of specified discharge capacity, head, delivery size in existing bore well including 2 sets of suitable size holding clamps made out of 50 mm X 6 mm MS flat, connection with suitable submersible cable of standard length etc. as required.
23.3.5 5 HP, 750 LPM, 20 m head, suction size 80 mm, delivery size 65 mm 1.00 Nos
87 23.7.2 Supplying and fixing of following sizes GM gate valve ISI mark in the suction/ delivery line etc. as required. 1.00 Nos
88 23.5.2 Supplying and fixing of following sizes 'B' class G I pipe with all necessary Tee's, bends, sockets in the suction/ delivery line including cutting and threading etc. as required. 40.00 RM
89 19.9 Providing and laying in trenches G.I. pipes medium class complete with G.I. fittings including excavation of trenches, refilling the same and testing of joints complete:
19.9.1 15 mm nominal bore 320.00 Rm
19.9.3 25 mm dia. nominal bore 310.00 Rm
19.9.6 50 mm dia. nominal bore 290.00 Rm
90 19.10 Making connection of G.I. distribution branch in G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: (dia of main line to be measured)
19.10.3 25 mm nominal bore 35.00 Each
19.10.4 50 mm nominal bore 25.00 Each
91 19.13 Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality:
92 19.13 Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality:
19.13.2 Bib cock (350 grams) 45.00 Each
93 19.17 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 45.00 Each
94 19.16 Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end):
19.16.1 25 mm nominal bore 25.00 Each
19.16.4 50 mm nominal bore 20.00 Each
95 19.47 Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design : 25.00 Each
96 19.24 Providing and filling fine sand or coarser grade all-round the G.I. pipes in external work.
19.24.1 15 mm diameter pipe 320.00 Rm
19.24.3 25 mm diameter pipe 310.00 Rm
19.24.6 50 mm diameter pipe 290.00 Rm
97 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (1:2:4)
3.1.5 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). 31.60 Cum
98 12.65 Providing & laying 60mm thick precast interlocking concrete blocks of approved size (approx 305 sqcm) and shape/ pattern, over 40 mm thick average complete coarse sand bed with joints of 3mm thick filled by fine sand including leveling with surface vibrator, temping and sweeping etc. complete of minimum compressive strength of 250 kg/sq.cm
12.65.2 Pigment Coloured (rubber mould) precast interlock concrete blocks 789.90 Cum
99 9.6 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.
9.6.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 1500.00 Kg
23.14 Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification 400.00 RM
100 15.4 Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing masonry open duct as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1).
101 15.6 Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 25x3 mm M.S flat clamp and steel dash fastener/ G.I. bolts and nuts as per specification , IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1).
102 6.29 Supplying of following 230/250 volts LED Flood light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt
103 19.18 Supplying erection testing and commissioning of hot dipped galvanised (single dip, minimum 86 micron) 12 metre High mast pole on existing RCC foundation with all accessories and equipments, main detailed as below to withstand max wind pressure as per IS 875 Part-3: a) HM shaft made of approx weight 340 kg, sheet thickness 3 & 4 mm, nominal dia 360mm on bottom and 150 mm on top, base plate 25mm thick 520mm dia, approved no of sections (not more than 2) having suitable sectional lengths with slip joints between sections without any circumpherencial welding. b) Double drum winch with Integral single phase power tool (electrical) for lowering & raising of lantern carriage on high mast with separate handle for manual operation of winch with a torque limiting device for safe locking of carriage. c) Raising/lowering type lantern carriage designed to carry specified nos of luminaries, control gear box, junction box. d) Top pulley assemble with weather proof cover. e) Necessary suitable length and size stainless steel wire ropes (minimum 6mm dia and 7/19 construction) for lowering & rising of lantern carriage. f) Suitable size and length multicore flexible copper power trailing cable (minimum 6 sqmm) g) Hinged service door in base section h) Base plate earthing terminal. i) Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast. j) Lightning conductor finial made of 25mm dia 300 mm long G.I.tube having single prong. k) Anchor plate, tem-plates, GI foundation bolts min 6 Nos of 24mm dia 750 mm long (EN 8 Grade) along with nuts washers etc. (RCC fooundation and luminaries will be paid separately)
104 6.18 Supplying, installation, testing and commissioning of following COB LED Spot Light fitting complete with Electronic Driver Heat sink Capacitor and all other accessories including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio a 100 lumens /watt.
105 27.2 Supplying installation testing and commissioning of ANALOGUE TYPE DOME AHD 2MP CAMERA of 1080P real time high resolution, CMOS progressive scan, True day/night capability Minimum illumination: 0 Lux (IR ON), TDN (IR-cut), AWB, AGC, Defog, 3:6mm & 2.8-12mm lens, IR distance: upto 40 meters, Power. 12VDC, Vandal resistant, Dual output AHD & CVBS as per specifications. 3.00 Each
106 27.3 Supplying installation testing and commissioning of ANALOGUE TYPE BULLET AHD 2MP CAMERA VF of 1080P real time high resolution, CMOS progressive scan, True day/night capability. Minimum illumination: 0 Lux (IR ON), TDN (IR-cut), AWB, AGC, Defog, 3.6mm & 2.8-12mm lens, IR distance: upto 40 meters, Power: 12VDC, Vandal resistant, Dual output AHD & CVBS as per specifications. 3.00 Each
107 27.4 Supplying installation testing and commissioning of ANALOGUE TYPE DOME AHD 2MP CAMERA VF of 1080P real time high resolution, CMOS progressive scan, True day/night capability. Minimum illumination: 0 Lux (IR ON), TDN (IR-cut), AWB, AGC, Defog, 3.6mm & 2.8-12mm lens, IR distance: upto 40 meters, Power: 12VDC, Vandal resistant, Dual output AHD & CVBS as per specifications 2.00 Each
108 27.8 Supplying, installation testing and commissioning of 08 CHANNEL AHD 1080P DVR high resolution recording, H.264 High profile compression, Playback 4/8/16 channels simultaneously, Multiple recording options: manual, schedule, motion detection, Pentaplex operation: live view, record, play back, backup and remotely access, HDMI and VGA output simultaneously upto 1080P resolution, 1 SATA HDD, DHCP, DDNS, IE browser and CMS supported, Mobile app for Android and los, Power: DC12V as per the specifications. 2.00 Each
109 27.9 Supplying, installation testing and commissioning of 16 CHANNEL AHD 1080P DVR high resolution recording, H.264 High profile compression, Playback 4/8/16 channels simultaneously, Multiple recording options: manual, schedule motion detection, Pentaplex operation: live view, record, play back, backup and remotely access, HDMI and VGA output simultaneously upto 1080P resolution, 1 SATA HDD, DHCP, DDNS, IE browser and CMS supported, Mobile app for Android and los, Power: DC12V as per the specifications. 2.00 Each
110 27.11 Supplying, installation, testing and commissioning of 4 MP Bullet Camera weather & dust proof IP based Fixed Lens day/night Camera (IP67, IK 10), 1/3" 4MP PS CMOS Image Sensor, H.265 and H.264 triple-stream encoding, WDR(120dB). Day/Night Support, UL CE FCC Certified as per the specifications. 2.00 Each
110 27.22 Supplying installation, testing and commissioning of 32 Channel NVR 8 Sata Port Up to 32 channel IP camera input, Max 320Mbps incoming bandwidth, Smart H.265+/H.265/Smart H.264+/H.264/MJPEG, Up to 12MP resolution preview and playback, Support 8 SATA HDDs up to 10TB each, 1 eSata, 4 USB(2 USB3.0, 2USB2.0), 2 HDMI / 2 VGA simultaneous video output ONVIF Version 2.4 conformance, Alarm In/out 16/6, Two way talk 1 Channel Input, 2 Channel Output RCA, 1 RS485, 1 RS232 2 RJ-45 port (10/100/1000Mbps), Support ANPR Camera as per the specifications. 2.00 Each
111 27.16 Supplying, Installation, testing and commissioning of 2 MP PTZ Camera weather & dust proof IP based Dome PTZ (Pan Tilt & Zoom) true day & night camera, 1/2.8" 2MP PS CMOS Image sensor, Max. 50/60fps@1080P, Color: [email protected]; [email protected] (IR on), Powerful 30x (4.5~135 mm) Optical and 16x Digital zoom, WDR(120dB), 3D DNR, Day/Night(ICR), Defog, ROI, EIS, AGC, BLC, HLC, Support Starlight Function, Up to 300 presets, auto scan, 8 tour, 5 pattern, auto pan, Tripwire, Intrusion, Abandoned/Missing, Face Detection, Heat Map, IR Range of 200 Mtr., Max 300° /s pan speed, 360° endless pan rotation, Built-in 7/2 alarm in/out, Micro SD card 256GB, IP67, IK10, Support PoE+, UL, CE,FCC certified as per the specifications 2.00 Each
112 27.26 Supplying, Installation, testing and commissioning of 4 Port Industrial POE Switch 10/100/1000 4 Port with 2 Giga SFP Uplink, Industrial PQE Switch, Support Dual DC Power Backup as per the specifications. 2.00 Each
113 27.29 Supplying, installation, testing and commissioning of 8 Port Industrial POE Switch 10/100/1000 8 Port with 4 Giga SFP Uplink, Industrial POE Switch, Support Dual DC Power Backup as per the specifications. 1.00 Each
114 27.31 Supplying, installation, testing and commissioning of 16 Port Giga PoE switch 10/100/1000 16 Port with 2 Giga SFP uplink, PoE switch Power Budget 150 watt, Single Port Max 30W, Al Extend AI VLAN as per the specifications 2.00 Each
115 27.34 Supplying, installation, testing and commissioning of 24 Port Managable POE Switch 10/100/1000 24 Port Managed PoE Switch with 2 Giga RJ45 & 2 Giga SFP combo uplink, Power Budget250W as per the specificatons. 2.00 Each
116 27.37 Supplying, installation, testing and commissioning of 4 TB Surveillance Hard disk drive Complete as required 2.00 Each
117 27.41 Supplying, installation, testing and commissioning of 16 Port Non PoE Giga Byte Switch 10/100/1000 16 Port Gigabit Network Switch as per the specifications. 1.00 Each
118 27.39 Supplying, installation, testing and commissioning of 8 TB Surveillance Hard disk drive Complete as required 2.00 Each
119 27.43 Supplying, installation, testing and commissioning of 24 Port Non PoE Managable Giga Byte Switch 10/100/1000 24Port Gigabit Managed L3 Network Switch with 4 Gigabyte SFP Port 2.00 Each
120 27.41 Supplying, installation, testing and commissioing of following size LED Monitor, table/wall mount with inbuild speaker minimum 5Wx2,with minimum 1 No of HDMI and USB port including remote control, connecting cable, batteries, and all accessories, connection etc complete as per specification
27.41.4 55 inch 1.00 Each
121 1.15 Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5)
122 2.13 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in surface FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) etc as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
2.13.6 3 X 4 sq. mm in 25mm conduit 180.00 Metre
2.13.9 3 X 16 sq. mm in 32mm conduit 190.00 Metre
123 30.1 Earth work in all type soil except soft rock / hard rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling of excavated soil in trench / pit to ground level complete as per specification. 17.50 Cum
124 30.5 Filling of excavation stuff of any kind made available for filling except B.C. soil in layers including ramming and watering. 5.25 Cum
125 30.13 Providing and laying Cast-in-situ cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm including mixing with mechanical mixer, compacting with vibrator, finishing and currying etc. complete but excluding form work. 8.75 Cum
126 19.7 Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 3mm thick anchor plate, 4 nos 20mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3)
19.7.1 6 metre high, dia 130mm at bottom and 90mm at top, base plate size 220x220x12mm, foundation bolts 600mm long 35.00 Each
127 19.12 Designing and providing suitable RCC foundation in Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for 3 mere to 12 metre high GI octagonal pole including steel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as per specification 17.50 Cum
128 19.4 Supply of GI PIPE POLE made of "B" class GI pipe making necessary hole for cable entry and providing earthing stud (welded at specified height) including painting with one coat of red oxide zinc chromate primer.
50 mm dia 1400.00 Metre
129 15.1 Supplying and laying following sizes one number FRLS PVC insulated/XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground at a depth not less than 40 cm and upto 90 cm including excavtion, sand cushioning, protective covering and refilling the trench etc as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1).
17.1.24 4x25 sq.mm 245.00 Metre
130 15.23 Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification.
131 9.10 Supplying and fixing SP MCB, 240 volts, 'B' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification.
9.10.1 6 amps to 32 amps 35.00 Nos
132 19.16 Supplying and fixing water tight terminal box made of 1.6mm thick M.S. sheet with detachable gland plate in bottom, hinged front open able cover, rubber gasket, having 1 Nos 4way connector and 1 No SPMCB inside the box for cable connection, fixed to pole with 2 Nos clamp made from 40x3mm M.S. flat with 2 No nut bolt dully painted with 2 coat of red oxide paint and 2 coat aluminium paint complete as per specification.
133 3.11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit /PVC casing caping as per specification and IS: 694 (2010)
134 12.2 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016) 35.00 Set
135 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M. 10.20
136 non sor Dustbin 12.00 Nos
SUB ENGINEER C.M.O.
boq_comp_chart.xls
BOQ Comparative Chart • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.10 MB
8981736664262932083_184172_Form A PDF.pdf
NIT • 8.71 MB
5719164515198646352_190201_NIT_189.doc
NIT • 0.28 MB
7529230892018038920_175164_BOQ - INDOOR STADIUM ,UTAI.xlsx
BOQ • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .