Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC 1ST FLOOR SCO 3 SECTOR 41 U T CHANDIGARH | NA | NA | 160001 | L1 | Accepted-AOC work awarded to M/s Hipath Tech. being L1 firm | |
| 2 | L2₹10.8 L+₹66,943 (6.59%)Rejected-Finance | L2 | Rejected-Finance rejected being L2 firm | |
| 3 | Rejected-Technical | - | Rejected-Technical BID RESPONSIVE BUT DISQUALIFIED | |
| 4 | Rejected-Technical PLOT NO F28 COMPLETE COOLING SOLUTIONS LLP PHASE 8 INDUSTRIAL AREA SAS NAGAR MOHALI PUNJAB 160055 | S A S NAGAR | PUNJAB | 160055 | - | Rejected-Technical BID RESPONSIVE BUT DISQUALIFIED | |
| 5 | Rejected-Technical | - | Rejected-Technical BID RESPONSIVE BUT DISQUALIFIED |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
17 May 2022, 10:00 amClosed
Executive Engineer, Electrical Division, HP.PWD M
Executive Engineer, Electrical Division, HP.PWD Mandi
Supplying, Installation Testing and Commissioning of Fire Alarm and PA System Warehouse for storage of EVM and VVPAT at Bhiuli District Mandi HP
2022_PWD_60436_1
PW/MED/TA/NIT/ e-notice/21-22-557-67 dt 29.04.22
Open Tender
Electrical Works
Item Rate
120 days
MANDI
please refer to bid doc
11 documents required · 11 mandatory
₹350
₹19,800
22 Nov 2022
9 May 2022
17 May 2022
9 May 2022
17 May 2022
9 May 2022
Amount
SITC of UL268 6th and 7th edition compliance and FM approved Intelligent Addressable multi-criteria detector (optical and thermal sensors) complete with standard base, facility to mount in different comprehensive environment, Tri-color detector-status LED with 360 ° view, microprocessor circuitry with error check; detector self-diagnostics and supervision programs,Rate-of-Rise Detection: 15°F / min. (8.3°C / min.) - Fixed: 135°F (57°C) , Field programmable as rate-of-rise or fixed temperature, Polarity insensitive, Superior EMI and RFI immunity, RoHS compliant. Detector shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature in detector shall consider Isolator base in place of standard base OR separate Isolator before and after every detector to comply the same without any extra cost. Make : Cerberus by Siemens/ Esser by Honeywell/Autronica
SITC of UL Listed Sounder cum Strobe rated at 75 dBA @ 3m for Audible annunciation and 75cd flashintg at 1 Hz for visual indication. Make : Cerberus by Siemens/ Esser by Honeywell/Autronica
SITC of UL listed and FM approved Intelligent addressable Class X type (Style 7), Manual Pull Station Single Action, Shock and Vibration Resistant, with built in dual isolator, polarity insensitive, Tri color LED for status (Green for Normal,Yellow for Faulty and RED for activation), T-45 Key Reset lockset for easy maintenance, Operating Temp and RH: 0-49degC and <=95%. MCP shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature shall provide separate Isolator before and after every MCP to comply the same without any extra cost. Make : Cerberus by Siemens/ Esser by Honeywell/Autronica
SITC of UL listed and FM approved Intelligent addressable Class X type (Style 7), Control Module with built in dual isolator, polarity insensitive, Tri color LED for status (Green for Normal,Yellow for Faulty and RED for activation), Operating Temp and RH: 0-49degC and <=95%. Module shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature shall provide separate Isolator before and after every Module to comply the same without any extra cost. (For AHU & Staircase Pressurization Fans, Hooters / Sounders / Strobes etc.) Make : Cerberus by Siemens/ Esser by Honeywell/Autronica
SITC of UL listed and FM approved Intelligent addressable Class X type (Style 7), Mini Monitor Module with built in dual isolator, polarity insensitive, Tri color LED for status (Green for Normal,Yellow for Faulty and RED for activation), Operating Temp and RH: 0-49degC and <=95%. Module shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature shall provide separate Isolator before and after every Module to comply the same without any extra cost. (For Sprinkler Flow Switches and door holders) Make : Cerberus by Siemens/ Esser by Honeywell/Autronica
SITC of UL 864 10th edition UL Listed and FM approved Analog addressable 2 Loop Fire Alarm Control Panel having the total panel capacity of 252 devices. The panel shall be able to give pin point location of all Fire /fault and Isolation conditions of addressable units via the address codes.The panel shall have the capacity of storing upto 10000 events. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel shall have a 2”x4-3/4” Size VGA monochromoe LCD display and having maximum 320 (8 x 40) Characters in the display with optional 24 Zones LED indicators. The panel shall have a built in power supply of 170 Watts and battery charger. Battery charger shall be able to charge the system batteries of up to 33AH capacity. The Panel shall have the capacity of connecting additional 31 panels or Network terminals using network card, with redundancy in the network. The panel shall have the capacity of connecting maximum 16 Remote terminals /16 remote displays or combined by using 2 X RS 485 Card. Make : Cerberus by Siemens/ Esser by Honeywell/Autronica
SITC of UL Listed and FM approved Repeater Panel. The panel shall be able to give location of all fire/fault and Isolation conditions of addressable units of main Fire Alarm panel via the address codes and also having remote-system-control capabilities. The panel shall have a 2”x4-3/4” Size VGA monochrome LCD display and having maximum 320 (8 x 40) Characters in the display along with RS485 Module. Make : Cerberus by Siemens/ Esser by Honeywell/Autronica
Supply and erection of PVC insulated two core FR copper conductor cable ISI marked in PVC pipe recess/surface complete in all respect Make - Finolex / Polycab /Hawells i) 2 core x 1.5 sq. mm
Supply and erection of PVC pipe 25mm dia ISI marked (Medium) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work. Make: BEC/Diplast /Polyplast
Supply, Installation, Testing and commissioning of IEC 60849 Approved Glow Type EXIT/Stair /Emergency Exit Sign Board as finalized by Engineer In Charge, on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener complete the work upto the entire satisfaction of Engineer In Charge. Make: PES /HEINRICH/ OMEX/ COOPER/Agni/Falcon
Supply,installation ,testing and commissioning of wall mounted 6 watt speaker as required complete in all respect. Make: JBL/Honeywell/Ahuja
Supply, Installation & comm. Of 120 W Power Amplifier as required complete in all respect. Make: Honeywell, Ahuja, JBL
Supply, installation ,testing and commissioning of 6 zone controller /paging control unit as required compelete in all respect. Make: Honeywell, Ahuja, JBL.
Saar Technologies
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .