Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC MEDICAL COLLEGE KOTTAYAM PHASE I GENERAL ELECTRICAL WORK ADDITIONAL WORKS OF BASEMENT FLOOR KERALA KL | L1 | Accepted-AOC L1 |
Tender Value
₹5.5 L
EMD Value
₹14,400
Closing Date
12 Dec 2019, 6:00 pmClosed
AEE,LSGD,DIVISION,KOTTAYAM
AEE,LSGD,DIVISION,KOTTAYAM
Electrification
2019_LSGD_317737_2
90/AEE/LSGD/KTM
Open Tender
Electrical Works
Item Rate
60 days
Ramapuram
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,210
Yes
EE,LSGD,DIVISION,KOTTAYAM
₹14,400
Yes
6 Feb 2020
5 Dec 2019
18 Dec 2019
5 Dec 2019
12 Dec 2019
5 Dec 2019
Amount
ELECTRIFICATION
Supply and wiring Single control light point through existing conduit using 1.00 sq mm PVC insulated stranded single core FR copper conductor cable including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FR wire ete according to IS 732-1989 and as per PWD specification (2012). with suitable size modular type metal switch boxes and front plates including 6 A modular type ROHS compliant SP switches 6A, 3 plate ceiling rose etc (Modular boxes ,switches and accessaries ,Make-Legrand Myrius/MK Blenz/Havells Oro/Hager/L&T)
Supply and installation of LED tube light fittings (Philips Endura high efficiency BN 108 C 20S CDL white ) directly on wall/ceiling with company made mounting accessaries and giving connection with 16/0.20mm 3 core copper conductor flex wire.
Supply and installation of LED Street light fittings LSTS-25-CDL Crompton make on 25 mm size GI Pipe 1 mtr long (minimum) bend/welded to shape and fixing to wall using sitable clamps and giving connection with with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS
Supply and providing 450 mm (18 inch) wall mounting Air circulator Almounard make (Tempest ) 100 w,Air delivry 150 m3/min, suitably mounted on wall.
Supply and fixing 20 mm dia light gauge PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including making good the damages etc as required.
Specification of work as detailed above with 25 mm dia PVC conduit on surface
Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.(Legrand/OBO/MK)
Supply and fixing External Angle 90°on existing CMS
Supply and fixing End Cap on existing CMS
Reducer 100 x 50 to 50 x 50 mm
Supply and fixing 50x 50 mm PVC Cable Management System with base and lid conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.(Legrand/OBO/MK)
Supply and fixing End Cap on existing CMS
Supply and drawing 1.50 sq mm 3 run 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections.
Specification of work as detailed above drawing 1.50 sq mm 4 run copper cable
Specification of work as detailed above drawing1.50 sq mm 5 run copper cable
Specification of work as detailed above drawing1.50 sq mm 6 run copper cable
Specification of work as detailed above drawing1.50 sq mm 7 run copper cable
Specification of work as detailed above drawing1.50 sq mm 8 run copper cable
Specification of work as detailed above drawing 2.50 sq mm 3 run
Specification of work as detailed above drawing 2.50 sq mm 6 run
Specification as detailed above drawing 4.00 sq mm 3 run
Specification of work as detailed above drawing 1.00 sq mm 3 run copper cable
Specification of work as detailed above drawing 1.00 sq mm 4 run copper cable
Specification of work as detailed above drawing 1.00 sq mm 5 run copper cable
Specification of work as detailed above drawing 1.00 sq mm 6 run copper cable
Specification of work as detailed above drawing 1.00 sq mm 7 run copper cable
Specification of work as detailed above drawing 1.00 sq mm 8 run copper cable
Supply and laying of 1.5 Sq.mm twin wire speaker cables in the existing conduit. (Approved makes: Belden/MX/Chetan)
Supply and fixing 3 plate ceiling rose on existing junction box
Supply and fixing 4 to 6 way PVC/Bakelite connector (Best quality) on existing modular switch box as looping of cables to switches
Supply & Fixing 2module metal box with white/ off-white front plate with blank plate in recess including making good the damages, colour washing etc as required (ROHS) including giving connections (speaker cable junction box) (Modular boxes ,switches and accessaries ,Make-Legrand Myrius/MK Blenz/Havells Oro/Hager/L&T)
Supply & Fixing 2module metal box with white/ off-white front plate provided with one 20A DP switch modular type in recess including making good the damages, colour washing etc as required (ROHS) including giving connections (Modular boxes ,switches and accessaries ,Make-Legrand Myrius/MK Blenz/Havells Oro/Hager/L&T)
Supply & Fixing 3 module metal box with white/ off-white front plate provided with 1 set of 16A SP switch and 6/16 A universel socket modular type in recess including making good the damages, colour washing etc as required (ROHS) including giving connections (Modular boxes ,switches and accessaries ,Make-Legrand Myrius/MK Blenz/Havells Oro/Hager/L&T)
Supply & Fixing 9 module metal box in recess with front plates provided with 3 nos of 6A SP switch and 3 nos 6 A universel socket modular type in recess including making good the damages, colour washing etc as required (ROHS) including giving connections(Modular boxes ,switches and accessaries ,Make-Legrand Myrius/MK Blenz/Havells Oro/Hager/L&T)
Supply & Fixing 4 module PVC box with front plates suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (ROHS)
Specification of work as detailed above for 6 module box with front plates
Specification of work as detailed above for 8 module box with front plates
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof (IP 42/43) double cover 8 way (8+18) - double cover TPN vertical DB with provision for fixing MCB as incomer and SP/ TP MCB as outgoing (IP 42/43) including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required (Legrand/Hager/L&T/ABB/Indo-Asian optipro)
Supply and installation of 6-32A 10KA, SP MCB( C curve) suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 in the existing enclosure and giving connections as required
Specification of work as detailed above with 63 A, 4 pole, 100 mA RCCB
Specification of work as detailed above with 63 A four pole mini break isolator
Supply, laying and clamping of 4 core 10 sq mm PVC insulated and PVC sheathed armoured aluminium power cable1.1 KV grade with factory made clamp , spacing of clamps not exceeding 60cms, making good the damages on wall , colour washing etc. as required.
Supply, laying and clamping of 2 core 6 sq mm PVC insulated and PVC sheathed armoured aluminium power cable 1.1 KV grade with factory made clamp , spacing of clamps not exceeding 60cms, making good the damages on wall , colour washing etc. as required.
Supplying and providing earth clamps for siemens/ tropodur type cable glands of size 4sqmm-16 sq mm with 12 mm wide x 1 mm thick as required.
Supplying and providing Brass cable gland for armoured aluminium conductor cable 1.1 KV grade, and making end termination,crimping aluminium tubular cable socket and providing earth clamps for cable gland as per KPWD standards suitable for 16 sq mm 4 core cable
Supply and installation of 100 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over switch switch in sheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement of the following ratings on existing angle iron frame work or directly to wall using necessary bolts & nuts, fixing the unit to wall, making good the damages, colour washing etc. including giving necessary connections as required.
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps including inspection chamber complete with 300 x 300 x 6 mm cast iron gully trap with covering at the top of the inspection chamber of earth pit and providing as test joint 25 x 3 mm GI strip of minimum length 20 cm and providing earth lead from the test joint to the earth electrode using 25 x 3 mm GI strip including cutting, drilling necessary holes on the test joint (in Hard soil)as per KPWD standard
Supply and drawing bare earthing conductors 3.15 mm copper (10 SWG) along with wiring/ cables and giving connection as required.
Supply and drawing bare earthing conductors 2.65 mm copper (12 SWG) along with wiring/ cables and giving connection as required.
Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
Supply and Installation of Outdoor type Thermo plastic meter box (600X300x214 ) suitable to fix 3 Phase Energy Meter with provision to fix in the box / base plate with 3 set of 80 A,415 V bakelite fuse fitting , fuse holder suitably rated HRC fuse and 80 A,2 way neutral link etc complete complete.
Supplly and providing iron hook grouted on wall /fixed suitably for service wire (Anchor bolt type)
Painting letters or figures of 2.50 cm, 4 cm or 5 cm height with enamel paint as identification mark to SB, DB, panel board etc as required
Charges for preparing drawing of the complete Electrical installation after completion of the present work and preparing completion report with KSEB service connection application form and submitting to the consumer for availng 3 phase service connection/Load regularisation
Bidder Name
Mighty
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_452298.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .