Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC LOWEST REASONABLE BID | |
| 2 | L2₹28.2 L+₹1.7 L (6.43%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹28.2 L+₹1.7 L (6.53%)Rejected-Finance SHOP NO 13 MOHINI MARKET KISHORE BAGH MANDORE JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹30.7 L+₹4.2 L (15.9%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹30.9 L+₹4.4 L (16.8%)Rejected-Finance MANDI PILIBANGA HANUMANGARH RAJ | HANUMANGARH | RAJASTHAN | 335063 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
26 Jan 2023, 6:00 pmClosed
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR-342010
REPAIR/MAINT AND IMPROVEMENT OF LT DISTRIBUTION NETWORK LT PANEL FB BOX AND OTHER ALLIED WORKS IN SECTOR F OTM AND MD ACCN AND REPAIR / MAINT AND IMPROVEMENT OF LT DISTRIBUTION NETWORK CABLES AND OTHER ALLIED WORKS IN AA UNDER GE ARMY NO 01 JODHPU
2022_MES_571879_1
82223/80/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY NO. 01
₹76,000
Yes
20 Mar 2023
29 Dec 2022
30 Jan 2023
29 Dec 2022
26 Jan 2023
13 Jan 2023
30 Dec 2022 - 12 Jan 2023
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation/ pipes/ cable etc, not exceeding 10sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in depth for foundation/ pipes/ cable etc, not exceeding 10sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for sand cushioning to underground cable screened unwashed Tibba Sand including watering and consolidation complete all as specified and as directed. Note:- Only punned thickness shall be measured and paid
Supplying and laying reinforced precast concrete cable cover, class LV, type 1 with flat, size 250mm x 150mm x 40mm complete laid over the cable perpendicular to the cable for protection complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, in soil complete all as specified and directed.
Removing of excavated surplus soils, not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for Cement concrete 1:3:6, type C2, using 40 mm graded stone aggregate for foundation of pole/struts/stay assembly etc complete all as specified and as directed.
M&L for Cement concrete 1:3:6, type C2, using 20 mm graded stone aggregate, all exposed surfaces finished fair for pedestal of poles/copping including necessary form work fair finishing to exposed surfaces using extra cement complete all as specified and as directed.
M&L for replacement of Prestressed cement concrete poles 9.0 M long of size 102mm x 172mm at top and 102mm x 279mm at bottom, class-10, conforming to relevant latest IS including dismantling and refixing of cross arm, security light fittings, brackets or any other existing fittings etc and connecting, testing, including dismantling and removal of old broken/unserviceable pole and cement concrete coping etc., at site. NOTE: - (i) Earthwork, PCC will be measured and paid separately under relevant item. (ii) Removal of dismantled items from site are included in rate quoted by the contractor. complete all as specified and as directed.
Supply and laying & testing in replacement of LT cable XLPE insulated, armoured, electric power cables (heavy duty) with multistranded aluminium conductor, 1100 volts grade, cross sectional area 25 sqmm, 4 core complete all as specified and as directed.
Supply and laying & testing in replacement of LT cable XLPE insulated, armoured, electric power cables (heavy duty) with multistranded aluminium conductor, 1100 volts grade, cross sectional area 35 sqmm, 3.5 core complete all as specified and as directed.
Supply and laying & testing in replacement of LT cable XLPE insulated, armoured, electric power cables (heavy duty) with multistranded aluminium conductor, 1100 volts grade, cross sectional area 50 sqmm, 3.5 core complete all as specified and as directed.
Supply and laying & testing in replacement of LT cable XLPE insulated, armoured, electric power cables (heavy duty) with multistranded aluminium conductor, 1100 volts grade, cross sectional area 70 sqmm, 3.5 core complete all as specified and as directed.
Supply and laying & testing in replacement of LT cable XLPE insulated, armoured, electric power cables (heavy duty) with multistranded aluminium conductor, 1100 volts grade, cross sectional area 95 sqmm, 3.5 core complete all as specified and as directed.
Re-routing/relaying of existing LT cable XLPE insulated aluminum conductor armoured with glavanized steel wire complete of any size and core from any position i.e ground /wall/poles/ culverts etc complete with protection pipe all as directed by Engineer-in-charge. Note:- (i) Old cable as obtained shall be re-used. (ii) Old serviceable protection cover, protection pipe and sand obtained under this item shall be reused if found serviceable. (iii) Earth work and any other new items shall be measured and paid separately under relevant items.
M&L for notice board of size not less than 1200 x 900 mm, suitable aluminium alloy frame, soft front surface used for pin-up any information, laminated back surface for damp resistant, wall mounted including all fixing arrangement complete all as specified and as directed.
S&F in repairs GI tubing of size 80 mm bore medium grade with all fitting/accessories for protection of cable on pole/wall/under road crossings complete all as specified and directed.
S&F in repairs GI tubing of size 50 mm bore medium grade with all fitting/accessories for protection of cable on pole/wall/under road crossings complete all as specified and directed.
S&F in repairs GI tubing of size 40 mm bore medium grade with all fitting/accessories for protection of cable on pole/wall/under road crossings complete all as specified and directed.
M&L for Auguring/ Drilling /Boring of holes under road, pavement, hard standing by trenchless technology by manual /machine, including fixing of HDPE pipe of 100 mm bore complete all as specified and directed.
M&L in replacement of unserviceable end termination/jointing kit, outdoor type heat shrinkable, suitable for 95 to 150 sqmm, 3.5 core 1100V, XLPE electric cable including disconnection and connection of LT cable to OH line complete all as specified and directed.
M&L in replacement of unserviceable end termination/jointing kit, indoor type heat shrinkable, suitable for 95 to 150 sqmm, 3.5 core 1100V, XLPE electric cable including disconnection and connection of LT cable to OH line complete all as specified and directed.
M&L in replacement of unserviceable end termination/jointing kit, outdoor type heat shrinkable, suitable for 185 to 400 sqmm, 3.5 core 1100V, XLPE electric cable including disconnection and connection of LT cable to OH line complete all as specified and directed:
M&L in replacement of unserviceable end termination/jointing kit, indoor type heat shrinkable, suitable for 185 to 400 sqmm, 3.5 core 1100V, XLPE electric cable including disconnection and connection of LT cable to OH line complete all as specified and directed:
M&L in replacement for LT straight through, hear shrinkable, suitable for 35 to 70 sqmm, 3.5 core 1100V, XLPE electric cable including disconnection and connection of LT cable to OH line complete all as specified and directed:
M&L in replacement for LT straight through, hear shrinkable, suitable for 95 to 240 sqmm, 3.5 core 1100V, XLPE electric cable including disconnection and connection of LT cable to OH line complete all as specified and directed:
M&L for disconnecting and reconnecting of burnt LT, XLPE cable to OH conductor on pole/ equipment including removing of faulty part of cable, preparation of cable for connection, suitable AL lugs, nut bolts etc complete all as specified and as directed. Note:- The cost of earth work for taking out LT cable loop and refilling will deemed to be included in above quoted rate.
M&L in replacement for steel structure, cross arms, bracing supports, clamps, back plates of any type, section incl. nuts, bolts, washers, welding, fabrication/bending cold or hot in any size and shape required at site complete applying of two coats of aluminum paints over a coat of red oxide primer including dismantling complete all as directed by Engineer-in-charge.
Dismantling insulators of any type and any size from existing poles complete all as specified and as directed.
Fixing only of any type and any size dismantled insulators (serviceable insulators retrieved from above item) complete all as specified and as directed at site.
S&F Pin type, porcelain, vitreous, white, green & brown insulator including one galvanised iron long steel spindle, two galvanised iron washer and one galvanised iron nut, working pressure 1100 Volts and of size 100 mm height x 65 mm dia complete all as specified and as directed.
S&F shackle type, porcelain, vitreous, white, green & brown insulator including galvanised iron straps of size 31x3mm, insulator bolt of 12mm dia, washers and nuts, working pressure 1100 Volts and of size 90 mm dia x 75 mm height complete all as specified and as directed.
Supply, fixing, stringing, testing and commissioning of ACSR insulated rabbit conductor of size 6+1/3.35 mm (as phase wire) binding with insulators including binding material and connection of all service connections/existing cables complete all as specified and as directed. Note :- (i) Rate of dismantling of old conductor is deemed to be included in quoted rate.
Supply, fixing, stringing, testing and commissioning of ACSR rabbit conductor of size 6+1/3.35 mm (as neutral wire) binding with insulators including binding material and connection of all service connections/existing cables complete all as specified and as directed. Note :- (i) Rate of dismantling of old conductor is deemed to be included in quoted rate.
M&L in replacement of stay assembly complete with 230mm x 230mm x 6mm thick plate and 16 mm dia stay rod all as shown in Elect Plate NO-1 of SSR-Part -1 including stay wire of 7/4 mm dia of suitable loop insulator of appropriate size complete all as specified and directed by Engineer-in-charge. Note: - Rate quoted is deemed to be inclusive of necessary excavation, PCC, stay wire, Loop insulator, clamps etc and dismantling of old stay assembly
M&L for Trimming and pruning of one tree complete cutting of all branches of any dia but not exceeding 75 mm up to a safe distance from the over head lines complete all as directed at site and disposal of branches/bushes to a distance and clearing the site all as directed by Engineer-in-charge. NOTE:- The necessary man power, tool & plant, cutting tools and JCB required for cutting/pruning of branches is deemed to included in the rate quoted for the job.
M&L for ZEBRA painting of PCC poles 9/11 m long along with road up to 1.5 m height from pedestal, with two coats of enamel synthetic paints in 30 cm height including painting of pole coping with white paint all as directed by Engineer-in-charge.
M&L for preparation of surfaces of steel tubular pole/rail pole up to 9 mtr long and painting with two coats of synthetic enamel silver paint over a coat of red oxide primer including painting the pole coping with white paint and zebra painting up to 1.5 mtr from pole coping complete all as directed by Engineer-in-Charge.
M&L for writing pole number of minimum 10 cm height with black paint over yellow paint base on PCC/steel poles of LT supply complete all as directed by Engineer-in-Charge.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red color and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and as directed.
M&L for Earthing complete with galvanized steel earth plate electrodes 600mmx600mmx6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection, watering pipe of 20 mm bore medium grade, all excavation, earth work in any type of strata, earth pit in PCC 1:3:6 type C1 RCC cover including, charcoal, salt, funnel, etc complete all as specified and directed. Note : Rate included for dismantling of old earth pit and removal from site.
M&L for spray painting to outdoor type, double door, LT panels/feeder pillar box and replacement of door hinges, sliding bolts, cable entry MS sheets, cable glands, pedestal locks, bow handle and connected accessories where required by welding, cutting, drilling etc and including fixing with MS nuts and bolts and painting two coats of spray painting by synthetic enameled paint complete all as specified and directed by Engineer-in-Charge. Note:- Panel should be vermin proof and close properly after repair.
Supply, fixing, testing and commissioning as in replacement of LT Panel board, outdoor type, floor mounted, factory made CPRI approved suitable for 415 volt, 3 PH, 4 wire, 50 Hz, AC supply system having bus bar chamber with copper bus bars duly insulated by insulation of RYB color 630 Amps rating mounted on porcelain insulators. The panel shall be powder coated, factory made double door made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40mm x40mm x6mm duly embedded in PCC (1:3:6) type C-1 platform and including wiring of multistranded copper cable of suitable size including lugs and cable gland to incoming and outgoing cables and re-routing of LT cables of change over within 10 mtr of distance etc all as directed at site and comprising of following:-
INCOMING:- (a) MCCB 4 Pole 415 volts 36 KA 400 Amps rating adjustable thermal type (Icu=Ics=100%) - 01 Nos (b) Panel mounted multifunction energy meter of accuracy Cl-0.5 rating - 01 No (c) RYB LED indication lamp panel mounting type (Set of three) - 01 No OUTGOING:- (a) MCCB 4 Pole 415 volts 25 KA 160 Amps rating adjustable thermal type (Icu=Ics=100%) - 02 Nos (b) MCB TPN 415 volts 10 KA 63 Amps - 01 Nos (c) MCCB 4 Pole 415 volts 25 KA 100 Amps rating adjustable thermal type (Icu=Ics=100%) - 06 Nos
Supply, fixing, testing and commissioning as in replacement of LT Panel board, outdoor type, floor mounted, factory made CPRI approved suitable for 415 volt, 3 PH, 4 wire, 50 Hz, AC supply system having bus bar chamber with copper bus bars duly insulated by insulation of RYB color 630 Amps rating mounted on porcelain insulators. The panel shall be powder coated, factory made double door made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40mm x40mm x6mm duly embedded in PCC (1:3:6) type C-1 platform and including wiring of multistranded copper cable of suitable size including lugs and cable gland to incoming and outgoing cables and re-routing of LT cables of change over within 10 mtr of distance etc all as directed at site and comprising of following:-
INCOMING:- (a) MCCB 4 Pole 415 volts 36 KA 400 Amps rating adjustable thermal type (Icu=Ics=100%) - 01 Nos (b) Panel mounted multifunction energy meter of accuracy Cl-0.5 rating - 01 No (c) RYB LED indication lamp panel mounting type (Set of three) - 01 No OUTGOING:- (a) MCCB 4 Pole 415 volts 25 KA 160 Amps rating adjustable thermal type (Icu=Ics=100%) - 02 Nos (b) MCB TPN 415 volts 10 KA 63 Amps - 01 Nos (c) MCCB 4 Pole 415 volts 25 KA 100 Amps rating adjustable thermal type (Icu=Ics=100%) - 04 Nos
Supply, fixing, testing and commissioning as in replacement of LT Panel board, outdoor type, floor mounted, factory made CPRI approved suitable for 415 volt, 3 PH, 4 wire, 50 Hz, AC supply system having bus bar chamber with copper bus bars duly insulated by insulation of RYB color 500 Amps rating mounted on porcelain insulators. The panel shall be powder coated, factory made double door made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40mm x40mm x6mm duly embedded in PCC (1:3:6) type C-1 platform and including wiring of multistranded copper cable of suitable size including lugs and cable gland to incoming and outgoing cables and re-routing of LT cables of change over within 10 mtr of distance etc all as directed at site and comprising of following:-
INCOMING:- (a) MCCB 4 Pole 415 volts 36 KA 320 Amps rating adjustable thermal type (Icu=Ics=100%) - 01 Nos (b) Panel mounted multifunction energy meter of accuracy Cl-0.5 rating - 01 No (c) RYB LED indication lamp panel mounting type (Set of three) - 01 No OUTGOING:- (a) MCCB 4 Pole 415 volts 16 KA 63 Amps rating adjustable thermal type (Icu=Ics=100%) - 08 Nos (b) MCB TPN 415 volts 10 KA 63 Amps - 01 Nos
S&F in replacement spreader terminals including required size nut, bolt etc suitable for MCCB, FP, 63 to 100 Amps complete all as specified and as directed.
S&F in replacement spreader terminals including required size nut, bolt etc suitable for MCCB, FP, 160 to 250 Amps complete all as specified and as directed.
S&F in replacement spreader terminals including required size nut, bolt etc suitable for MCCB, FP, 400 Amps complete all as specified and as directed.
S&F Fuse wire, 40 amp to 60 Amp all as directed by Engineer-in- Charge.
S&F lugs of size 16 sqmm to 35 sqmm all as directed by Engineer-in- Charge.
S&F lugs of size 50 sqmm to 95 sqmm all as directed by Engineer-in- Charge.
S&F lugs of size 120 sqmm to 185 sqmm all as directed by Engineer-in- Charge.
Nvimal Engineers and Contractor
Sachiyay maa Electricals
RISING ELECTRICALS
SARASWATI ELECTRIC STORE
M/S SHREE AAINATH ENTERPRISES
Shri Electrical Enterprises
L C ASSOCIATES
SAGGI ELECTRIC COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .