| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.7 LAccepted-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹51.0 L+₹3.2 L (6.70%)Rejected-Finance | L2 | Rejected-Finance Other then lowest bidder | |
| 3 | L3₹51.3 L+₹3.5 L (7.30%)Rejected-Finance | L3 | Rejected-Finance Other then lowest bidder |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
28 Mar 2022, 6:00 pmClosed
CWE (AF) CHILODA
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
SPECIAL REPAIR / REPLACEMENT OF BER E/M ITEMS AT AF STN BARODA
2022_MES_508306_1
82106/BRD/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BARODA
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE (AF) BARODA
₹97,000
Yes
7 Apr 2022
16 Feb 2022
5 Apr 2022
16 Feb 2022
28 Mar 2022
16 Mar 2022
17 Feb 2022 - 3 Mar 2022
Amount
Dismantling & removing of BER AC plants (03 Nos x Package AC) safely and deposited to EM store yard as directed by Engr-in Charge
Dismantling & removing of UNSV PGI ducting of size 80cm x80cm with all material all as directed by Engr-in -Charge
Dismantling & removing of BER AC unit of any type or capacity from any height safely and deposited to EM store yard as directed by Engr-in Charge
Supply , install , commissioning and testing of Air Cooled Packaged Air Conditioners of 415Volt, 50Hz, 3 Phase four wire AC supply, comprising of Hermetic or Hermetically sealed Scroll Compressors with microprocessor based control, including copper refrigerant piping, electrical interconnection between indoor and outdoor units , suitable for operation on R - 22/R - 407c/R -410a refrigerants(Echo Friendly refrigerants) and of nominal capacity of 11 Ton all as specified and directed by Engr-in-Charge. Above installation consisting with following items. (a) All refrigerant piping between indoor and out door units duly insulated with 19mm /13mm nitrile rubber insulation. All piping inside the room shall be properly supported with 11 TR ,50Mtr (b) SITC of insulated grey PVC drain piping for ducted indoor unit 30 Mtr . (c) Control cabling indoor and outdoor unit 75 RM. (d) GI Sheet metal work of 22 G 60 Sq mtr (e) Flexible canvass connection with insulated GI duct piece for all ducted indoor units 3 Nos . (f) Thermal & Acoustic Insulation of ducting-: (i) Thermal insulation of GI ducts with class 'O' nitrite rubber 09mm thick 70 Sq Mtr. (ii) Acoustic insulation of GI duct with 10mm thick nitrite rubber 20 Sq Mtr (g) SA Grilles/RA grilles VCD /diffuser/Dampers etc. (h) Supply air/Return air grilles continuous 5 Sq Mtr . (j) Testing & Commissioning of AC system 03 Nos unit . (k) Acoustic Insulation for AC unit room with 50 mm thick fibre glass/ rock wool - 48 kg/m3 density covered with 30 g aluminium perforated sheet 110 Sq Mtr- (l) Ladder type tray with cover for exposed refrigerant piping 20 RM. Note : All civil works required for fixing of AC plant , ducting passing cables , pipes including necessary floor and wall fininshing shall be carried out as per existing to match etc complete and the cost of civil works shall be deemed included in quoted rates
M&L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground. (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. Below ground level connecting to galvanised iron wire of 4 mm as earth lead by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe light grade, 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM ( weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified and testing on completion. Note: Cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt, 15mm dia, medium grade, GI pipe as protection to earth lead and earth lead as 4 mm dia GI wire (main earthling lead from earth electrode to test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing.
Supply, installation, testing & commissioning of hi wall split units indoor/outdoor complete with cordless remote control unit and within built air ioniser and plasma filter for better indoor air quality of capacity 1.5 TR 230 volt AC 50 c/s of 5 star rating including excess copper tubing if required beyond the length supplied with AC unit , PVC conduit of 15mm dia not exceeding 2.5 mtr long for water drain and making good to disturbed surface with cement mortar 1:3 including testing complete comprising of the following: - (a) 1.5 Ton capacity using Eco friendly refrigerant cooling unit wall mounting type complete with remote control draining out arrangement manually adjustable cover for cool air from front with and inter connection with the condensing unit etc all as specified and directed by Engr-in-charge. (b) One No condensing unit of 1.5 ton capacity comprising of all fitting such as single phase electric driven compressor, condensing fan motor, condenser with fixing of stand on wall and all necessary controls and accessories all as specified and directed by Engr-in-charge.
Supply, installation, testing & commissioning of hi wall split units indoor/outdoor complete with cordless remote control unit and within built air ioniser and plasma filter for better indoor air quality of capacity 2.0 TR 230 volt AC 50 c/s of 4 star rating including excess copper tubing if required beyond the length supplied with AC unit , PVC conduit of 15mm dia not exceeding 2.5 mtr long for water drain and making good to disturbed surface with cement mortar 1:3 including testing complete comprising of the following: - (a) 2.0 Ton capacity using Eco friendly refrigerant cooling unit wall mounting type complete with remote control draining out arrangement manually adjustable cover for cool air from front with and inter connection with the condensing unit etc all as specified and directed by Engr-in-charge. (b) One No condensing unit of 2.0 ton capacity comprising of all fitting such as single phase electric driven compressor, condensing fan motor, condenser with fixing of stand on wall and all necessary controls and accessories all as specified and directed by Engr-in-charge.
M & L Sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing caping wire size 2x4.0 sq. mm + 1x2.5 sq. mm earth wire complete all as specified
S&F Sheet metal enclosure with 20 Amp 240 V socket plug top and MCBs single pole and neutral enclosure with two pin and earth plug and socket with one single pole 20 Amp MCB complete as in repairs all as specified
S&F Automatic Voltage Stabilizer digital type of 5 KVA capacity single phase input varying from 130 to 300 Volts and output Voltage Stabilizer 230 V fixing on wall with necessary support as required complete including testing on completion
S&F Automatic Voltage Stabilizer digital type of 4 KVA capacity single phase input varying from 130 to 300 Volts and output Voltage Stabilizer 230 V fixing on wall with necessary support as required complete including testing on completio
M & L Mild steel framed work for support/hanging with angle iron section as required size or other section with gasket plates, rails, braces, etc of grade Fe-410W, E-250 quality A complete, Doors, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engr- in- Charge
Supplying, installation, testing and commissioning of diesel engine driven Generating Set of 62.5 KVA(59KW) capacity, brushless type alternator self exited, self regulated and fitted with AVR and screen protected Drip proof with IP 23 protection , AMF panel of under at N. T. P condition fully wired 415 V AC 3 phase, 4 wire 4 stroke 50 Hz, at a power factor of 0.8 lagging all as per IS-4722/2001 mounted on common base plate and directly coupled through flexible coupling closed couple to diesel engine with Dunlop cushion foot mountings (anti vibration) pad in and including acoustic insulated enclosure/canopy with ARAI approved and as per CPCB norms and size of PCC/RCC foundation as per manufactures recommendation and complete all as specified and as directed by engineer-in-charge at site etc & consisting of the following:- (A) Diesel Engine:- the engine shall be vertical multi cylinder four stroke 1500 RPM water cooled developing 79.09 BHP confirming to BS:5514 suitable for continuous running fitted with electric governor, safety protection of LLOP & HWT complete with water pump assembly turbo charger, battery charging alternator of 12 V instrument panel, electronic in built, battery heavy duty with leads of suitable size and exhaust pipe of suitable length inclusive of exhaust coupling inside acoustic enclosure and residential silencer pipe above canopy all as specified & directed by OEM and all other standard fittings/fixtures and all as per OEM specification complete as per IS-1602 for the generator including the following:- (a) Engine protection devices including audio visual indicators & OFF system during low lube oil pressure high water temperature over speeding of engine (b) Radiator cooling system comprising of radiator fan blade water pump with belts thermostat guard (c) Hour meter
(B) AMF panel:- the AMF panel shall be fabricated & mounted on 100 mm MS channel frame shall be totally enclosed cubical type fabricated out of 2mm thick CRCA sheet duly powder coated with 7 tank chemical powder coated process locking arrangement provn of self ventilation with wire mesh etc complete including with base etc 2 Nos contactors with 01 No as spare, 4 pole 415 V 50 Hz AC supply DG auxiliary contactors relays for automatic operation of DG set in case of failure commercial supply & vice versa tinned copper busbars of 1.8 times of alternator rated capacity with heat shrinkable PVC sleeves cable termination box with suitable size of glands and comprising following accessories all as specified & directed by Engineer-in -Charge (C) Acoustic insulated enclosure/canopy for gen set:- The gen set to be provided with acoustic insulated enclosure/canopy fabricated out of CRCA sheet 16 SWG & pre treated with 7 tank phosphating prior to polyester coating painting close fit type compact enclosure provided with adequate ventilation system to ensure perfect aspiration and cooling of the DG set to bel housed inside and avoid over heating /power deration. Acoustic insulation sound proofing should be made with a high quality insulation conforms to UL94-HF1 class for flammability and suitable including the following:- (a) Control panel should have blanking windows made out of toughen glass provided with rubber beading (b) Emergency stop button should be easily accessible (c) Provn of fitting of branded make including wiring inside canopy (d) Access to fill fuel tank control shall be from outside the canopy enclosure
(e) All door, windows panels should be lockable with single key (f) Single/multi point lifting facility should be available on the base frame (g) Access to fill the radiator from outside the canopy (h) Specially designed as per manufacturers standard alternators are to be provided control sound at entry to canopy and exist from canopy (j) Adequate ventilation has to be provided to meet the air requirement of engine and alternator Note:- (i) Temperature rise in the compartment/canopy should be less than 5 degree centigrade (ii) It should adhere to mandatory noise regulation norms (iii) It should be duly approved and guaranteed by the engine manufacture(iv) The acoustic insulated enclosure/canopy must be designed as per relevant IS and control the noise level all as specified in Govt of India notification.(v) LT cable from DG set to AMF panel shall be measured & paid separate(vi) The FOL etc required for commissioning and testing of DG set shall be supplied by the contractor. This shall be deemed to be including in the quoted rate of gen set (vi) Inverter canopy light of 10 W capacity luminous/narcotic make with necessary connecting from DG set battery.
M&L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground. (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. Below ground level connecting to galvanised iron strip 32x6 mm as earth lead by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe light grade, 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM ( weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified and testing on completion. Note: Cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt, 40mm dia, light grade, GI pipe as protection to earth lead and GI earth strip 32x6 mm (main earthling lead from earth electrode to test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing.
M&L Lowering of submersible pump and motor set alongwith existing column pipe of any size with including provision of new jointing materials such as rubber gasket, nuts and bolts and washers, pipe connection, jointing with M-Seal Jointing cable kit connection and testing complete.
Supply, install, testing and commissioning Submersible Pump set, electric driven motor of 15 HP/11KW, 415 V,50Hz, coupled with multistage pump of suitable capacity and discharge on required head (not less than 25mtr) as directed by Engr-in-Charge, size of 200/250 mm dia bore well Install complete all as specified and directed.
Supply, install, testing and commissioning Submersible Pump with suitable stages with 100 mm size head not less than 30 mtr discharge >2000LPM, coupled with electric driven motor of 30 HP, 415 V,50Hz, including stainless steel impeller, mechanical seal & stainless steel shaft complete assembled on tie rod recommended by OEM . Install complete all as specified and directed. Note- 1. Rate of Fixing, lowering, flanged fabrication and fixing of nipple etc other accessories used for fixing of pump are deem included in quoted rate. 2.Rate of 5Mtr of MS pipe of 150 mm dia also included in quoted rate.
S&F Monoblock pumping set of 65x50 mm size with 3000 RPM and discharge of 550-300 LPM on 45-60Mtr head suitable for 415 V 3 phase of 10 HP capacity motor including stainless steel impeller, mechanical seal & stainless steel shaft complete assembled on common iron frame recommended by OEM and grouted on foundation including testing and commissioning complete all as specified .Note- PCC /RCC foundation for grouting of Pump is dim included in quoted rate. Required length of MS pipe and fabrication of suction and delivery pipe also included in quoted rate.
S&F PVC insulated flat Submersible Cable with copper conductor 3 core 10 sqmm as in repairs all as specified
S&F PVC insulated flat Submersible Cable with copper conductor 3 core 06 sqmm as in repairs all as specified
S&F Fully automatic Star Delta Starter suitable for 15HP submersible pump set 415 V 3 Ph supply complete as in repairs all as specified and directed.
S&F Fully automatic Star Delta Starter suitable for 30HP Centrifugal pump set 415 V 3 Ph supply complete as in repairs all as specified and directed.
S&F Fully automatic DOL Starter suitable for 10HP Monoblock Centrifugal pump set 415 V 3 Ph supply complete as in repairs all as specified and directed.
S&F Chemical feed dozer model RC series Chemical Dosing (metering) Pump electromagnetic type with suction & discharge tubing, spring loaded anti siphon valve, foot valve etc complete with maximum discharge of 6 ltrs / hr with 4 kg back pressure motor operated suitable for mixing hypo chloride of capacity 100 ltr tank with stroke adjustment of 0 to 6 LPH complete with fittings and piping network.
Supply install testing and commissioning of Non clog vertical Submersible Pumps 15 HP suitable for operation on 415 Volt AC 50Hz 3 Ph supply with 1000 LPM discharge on 40 mtr head incl. chrome steel impeller and cutter, non-clog to pass 40 mm size particles including Supply, installation with guide rail and lifting chain complete with lowering of pump and fixing of HDPE delivery of suitable size as directed by Engr in Charge. Note- 1. Rate of HDPE Pipe of 10 Mtr length are inclusive in quoted rates. 2. Rate of Flat submersible cable & DOL starter will be measured and paid separately.
Chamunda Kruparefrigeration
Jyoti Refrigeration
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .