Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 204 205 KAILASH TOWER TONK ROAD JAIPUR RAJASTHAN | JAIPUR | JAIPUR | RAJASTHAN | 302015 | Admitted-Finance |
| 2 | Admitted-Finance B WING 601 602 DELPHI BUILDING CENTRAL AVENUE HIRANANDANI BUSINESS PARK POWAI MUMBAI MAHARASHTRA 400076 | MUMBAI SUBURBAN | MAHARASHTRA | 400076 | Admitted-Finance |
| 3 | Admitted-Finance 96 ELECTRONIC CITY COMPLEX BANGALORE KARNATAKA 560100 | BENGALURU URBAN | KARNATAKA | 560100 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
8 Dec 2020, 6:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Mr. Puneet Khanna (Dir-Supply Chain Management)
Worley India Private Limited, (formerly Jacobs Engineering India Private Limited) New Energy House, Ramakrishna Mandir Road, Kondivita, Andheri (East), Mumbai-400 059, India
FIELD INSTRUMENTS TRANSMITTERS (P, DP, F, L, T, TD) LOT 3
2020_REFHQ_127536_1
44AD0600-ER-64-0244
Limited
Instrumentation-Goods
Supply
120 days
IOCL GUJARAT REFINERY
3 documents required · 3 mandatory
Exempted
3 Feb 2021
24 Nov 2020
9 Dec 2020
24 Nov 2020
8 Dec 2020
1 Dec 2020
120 days
Flow Transmitters - Total QTY: 10 Nos. (Line item 1.1 to 1.10) & Pressure Differential Transmitter QTY: 1 No (Line Item 1.11), Refer Doc. No. 44AD0600-00/J.04/0244 for Datasheets
Sensor Material: GOLD PLATED MONEL, Range: 0-24000 Nm3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: SS 316 (As Min), Range: 0-55 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: SS 316 (As Min), Range: 0-55 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: SS 316 (As Min), Range: 0-55 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: SS 316 (As Min), Range: 0-55 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: SS 316 (As Min), Range: 0-30 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: SS 316 (As Min), Range: 0-68 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: SS 316 (As Min), Range: 0-68 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: SS 316 (As Min), Range: 0-68 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: SS 316 (As Min), Range: 0-68 m3/h, DP @ Full Scale: 2500 mmH2O, With Kidney Flange Adapter
Sensor Material: SS 316 (As Min), Range: 0-3 kgf/cm2, With Kidney Flange Adapter
Integral Orifice with Flow Transmitters - Total QTY: 03 Nos. (Line item 2.1 to 2.3), Refer Doc. No. 44AD0600-00/J.04/0244 for Datasheets
Integral Orifice Meter Run with flanges - 1" RF/300#, 125 AARH, Plate MOC:MONEL Sensor Material: GOLD PLATED MONEL, Range: 0-0.8 m3/h, DP @ Full Scale: 2500 mmH2O, With 3-Way Manifold
Integral Orifice Meter Run with flanges – 1”, RF/300#, 125 AARH, Plate MOC: SS316. Sensor Material: SS316 (As Min), Range: 0-20 Nm3/h, DP @ Full Scale: 1250 mmH2O, With 3-Way Manifold
Integral Orifice Meter Run with flanges – 1”, RF/300#, 125 AARH, Plate MOC: SS316. Sensor Material: SS316 (As Min), Range: 0-75 Nm3/h, DP @ Full Scale: 1250 mmH2O, With 3-Way Manifold
Description of Work / Item(s)
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.01 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.02 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.03 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.04 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.05 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.06 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.07 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.08 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.09 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.10 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.11 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.01 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.02 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.03 OF BOQ1
Emerson Process Management
YOKOGAWA INDIA LTD
YOKOGAWA INDIA LTD
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .