Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.9 L+₹6,331.80 (1.08%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹6.0 L+₹12,231.80 (2.08%)Rejected-Finance 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L3 | Rejected-Finance NOT L1 | |
| 4 | L4₹8.0 L+₹2.1 L (35.8%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-Finance NOT L1 |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
20 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I A Jamnagar
INFANTRY LINES JAMNAGAR
REPAIR REPLACEMENT OF LT UG CABLES AND UNSERVICABLE PANELS AT INF LINES JAMNAGAR
2020_MES_354836_1
8710
Open Tender
Electrical and Maintenance Works
Item Wise
180 days
Jamnagar
AS PER TENDER
6 documents required · 6 mandatory
₹500
Yes
₹18,000
Yes
29 Jul 2020
23 Jun 2020
21 Jul 2020
3 Jul 2020
20 Jul 2020
3 Jul 2020
60 days
Amount
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations and laying of cable, erection of RCC pole and getting out in any type of soil etc complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed.
Removing excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L dry river sand in trenches for cable cushioning & protection including spreading, ramming all as specified and directed.
Supply & Laying precast PCC cable concrete cable cover LV low voltage type -I flat size 250 mm x 150 mm x 40 mm complete
S&F GI Pipe light grade 80 mm for road crossing/ on pole/ on wall for protection of LT Cable.
S&F GI Pipe light grade 40 mm for road crossing/ on pole/ on wall for protection of LT Cable.
Supply & Laying only in trenches / poles / walls XLPE insulated, armoured, heavy duty electric power cable with aluminium conductor 1100 volts grade for following size with lugs including taking out old unserviceable cable/ACSR complete all as specified and directed by Engineer-in-Charge (Make :- Polycab/Havells/Finolex. NOTE : (i) Excavation and earth work, GI pipe protection, sand cushioning shall be measured and paid under relevant items.
(a) 6 Sqmm x 2 core
(b) 10 Sqmm x 2 core
(c) 10 Sqmm x 4core
(d) 16 Sqmm x 4 core
(e) 25 Sqmm x 3.5 core
(f) 35 Sqmmx 3.5 core
(g) 50 Sqmm x 3.5 core
(h) 70 sqmm x 3.5 core
Supply & fix in replacement of Prestressed concrete pole, 9.0 mtrs long, 102 x 172 mm at top and 102 x 279 mm at bottom (class 10), all as specified and directed. Note: Excavation, earth work and PCC will be measured and paid separately.
M&L in replacement of shackle type Insulator porcelain vitreous white/ brown or green, 75 mm high and 90mm dia suitable for working pressure of 1100 Volt including Galvanized steel straps of size 31x3 mm , nut, bolt of dia 12 mm and washers of suitable size, complete all as specified and directed.
M&L in replacement of pin type Insulators Porcelain vitreous white or green including one Galvanized mild steel spindle, two GI washers and one GI nut complete for insulators of 100mm high and 65mm dia suitable for 1100 Volt electric pressure complete.
Taking down old ACSR conductor from LT line complete as directed by Engineer-in- Charge.
Material and labour for aluminium conductor, steel reinforced (ACSR) of any size, stringing properly on insulators on pole and binding with aluminium tape / binding with conductors, jumpers etc complete all as specified and directed
M&L for stringing and fixing of aluminium conductor steel reinforced (ACSR) on LT poles including binding wire complete all as specified and directed at site of any type ACSR conductor and all as reinforced and directed.
M/L for replacement of cross arms, bracings, supports, clamps, straps D-clamps, back plates and MS frames fabricated from structural steel sections such as MS channel, angle iron and flats etc including nuts, ,bolts, washers eye hooks, welding, bending cold or hot drilling holes for bolts in any shape or size including two coats of synthetic aluminium paint over a coat of red oxide primer after preparation of steel surface complete all as specified.
S&F in replacement of stay wire galvanised strand size 7/3.15mm complete all as specified and directed by Engr-in-charge
S&F in replacement of stay assembly complete with 16mm dia stay rod accessories shown in electric plate No. 1 SSR 2009 all as specified and directed by Engr-in-Charge Note: Loop insulator, Stay clamp, excavation and concrete measured and paid separately.
S&F in replacement of loop type insulator vitreous porcelain white/ brown green small size with overall dimension 65x90mm, clearance of hole 16mm for fixing on stay wire all as specified and directed by Eng.-in-charge
M&L for earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to GI wire 4 mm by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways including charcoal dust and salt in layers all as shown in electrical plate No. 3 of SSR Part-I all as specified and directed.
Supply, stretching and fixing in position GI earth wire on poles for continuous earth wire of 4 mm dia or 3.15 mm dia galvanised steel wire including stretching and proper binding complete all as specified and directed including taking down the existing & removing from site.
M&L for PCC 1:2:4 typeB-1 using 20 mm graded broken stone aggregate as in mass concrete in coping of existing and new PCC/steel poles etc complete all as specified and directed .
M&L PCC (1:3:6) type C-2 using (40mm) graded stone aggregates as in foundation filling and mass concrete (for foundation bed concrete in poles or any other directed site)
Pruning of tree branches n. exec 30cm girth to clear LT/ HT Over head lines up to a distance of 3 Mtr clear span around the over head line and disposed off tree branches including repairing/ stretching/ binding of copper / aluminium conductor damage during the pruning. Note- Pruning distance only measure not full span .
M&L for trial boring 80 mm dia in road crossing/drains with mechanical help and other necessary arrangement to be provided by the contractor during execution complete all as specified and directed by the Eng -in - charge.
J J ENTERPRISE
fakhrie apostrical
JAYESH TRADING CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .