| 1 | L1₹1.9 CrAccepted-AOC | ₹1.9 Cr | L1 | Accepted-AOC Being L1 agency and meeting NIT criteria |
| 2 | L2₹2.1 Cr+₹11.0 L (5.68%)Rejected-Finance 201 PLOT NO 32 SHALAKA BLDG TPS II JUHU ROAD SANTACRUZ WEST MUMBAI SUBURBAN MAHARASHTRA 400054 | MUMBAI SUBURBAN | MAHARASHTRA | 400054 | ₹2.1 Cr+₹11.0 L (5.68%) | L2 | Rejected-Finance Being L2 agency |
| 3 | L3₹2.1 Cr+₹12.3 L (6.35%)Rejected-Finance NO 2 429 VOLTECH ECO TOWER MOUNT POONAMALLE ROAD AYYAPPANTHANGAL CHENNAI KANCHIPURAM TAMIL NADU 600056 | THIRUVALLUR | TAMIL NADU | 600056 | ₹2.1 Cr+₹12.3 L (6.35%) | L3 | Rejected-Finance Being L3 agency |
Tender Value
₹2.3 Cr
EMD Value
₹4.5 L
Closing Date
12 Oct 2020, 6:00 pmClosed
Asst.Gen.Manager(E-E)
Airports Authority of India, Trichy International Airport, Trichy -620007
Operation and carrying out day today maintenance of 11KV substation, Power supply system of operational area, Runway and associated E and M installations
2020_AAI_58784_1
ARMO-03/TRY/20-21
Open Tender
Electrical Works
Item Rate
730 days
Power house and Opeartional Area of Trichy Airport
Meeting the NIT criteria as per tender notice published
7 documents required · 7 mandatory
₹1,180
Airports Authority of India
₹4.5 L
4 Nov 2020
30 Sept 2020
16 Oct 2020
1 Oct 2020
12 Oct 2020
1 Oct 2020
1 Oct 2020 - 8 Oct 2020
Amount
Job contract for operation & Maintenance of various Electrical & Mechanical Installations and GLF Installations as detailed in "Annexure-B" of operational and non operational area such as 11KV Sub-Station, OTB, CCR including operation, repairs & maintenance, attending faults / breakdown rectifications, ensuring serviceability / satisfactory working conditions of the system, attending complaints, preventive maintenance on daily / weekly / monthly / quarterly / half yearly / yearly basis maintenance of records / documentation etc., as per scope of work given in special conditions of contract in all days including sunday and holidays. The services of DG Sets, AMF Panels at power house shall be ensured round the clock (i.e. in three shifts daily, each shift of 8 hours) and the services of all others E&M Installations shall be ensured for three shifts (each of 8 hours) daily as required. by engaging minimum number of staff as stipulated in the special conditions of the contract .
Providing maintenance vehicle for use in day to day maintenance of Electrical installation, operational requirement and office purpose on all days including national holidays and sunday as per special terms and conditions in addition to general terms and conditions of contract as required for a maximum of 1500KM per month (Type of vehicle :SCORPIO/ TAVERA / QUALIS / BOLERO / TATA SUMO GOLD) (Approx. 1500 KM per Month)
For First Year
For Second Year
Dehydration and filtration of transformer oil at site with high vacuum filtration apparatus to obtain BDV value 40 KV for 1 minute as required, topping of oil and submission of test reports etc. as required for following Transformers. (Make: Kirloskar, Capacity 1250 KVA, Oil Capacity 850 Ltrs, Qty - 3 Nos)
1st Year
2nd Year
Supply of transformer top-up oil suitable for kirloskar make, 1250 KVA Transformer.
Testing the BDV value and PH value by applying minimum 40 KV for 1 minute of transformer oil of two samples (top and bottom) and submission of report as required.
1st Year (3 Transformers 6 tests)
2nd Year (3 Transformers 6 tests)
Inspection, servicing and testing of 630A, Avera make, 11 KV Vaccum Circuit Breakers as per OEM method and practice including carrying out preventive maintenance and submission of test reports etc. as required.
1st Year
2nd Year
Carrying out secondary injection tests & calibration of over current, earth fault, auxilary, supervision and triping relay set (2 Over current,1 Earth fault, 2 Auxilary, 1 Trip and 1 Supervision relay) of 11 KV HT panel including submission of reports as required.
1st Year
2nd Year
Inspection, servicing and testing of following GE make Air circuit breakers including carrying out preventive maintenance asper OEM recommendations and submission of test reports etc. as required. (Two services per year) a) 2500A - 8 Nos b) 2000A - 12 Nos c) 1600A - 1 No d) 1250A - 4 Nos e) 800A - 10 Nos
1st Year
2nd Year
Rewinding, servicing, repairing of ceiling fan upto 1400mm sweep including replacement of wornout / defective parts like bearings, capacitors etc., i/c transportation from site to workshop & back to site. (Dismantled Material belongs to contractor).
Rewinding, servicing, repairing upto 450mm sweep wall mounted fans/exhaust fans/pedestal fans including replacement of wornout / defective parts like bearings, capacitors etc., i/c transportation from site to workshop & back to site. (Dismantled Material belongs to contractor).
Rewinding, servicing, repairing above 450 - 600mm sweep wall fan / Exhaust fan/Pedestal fan including replacement of wornout / defective parts like bearings, capacitors etc., i/c transportation from site to workshop & back to site. (Dismantled Material belongs to contractor).
Repair and rewinding of submersible / monoblock pump motor set below & upto 3 HP capacity Job include transportation of motor dismantling and rewinding with the same gage insulated copper wire including replacement of all the internal worn out / defective parts i.e bushes, impellers, sleeves, upper and lower bushes sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required.
Repair and rewinding of submersible / mono block pump motor upto 5 HP Job include transportation of motor dismantling and rewinding with the same gage insulated copper wire including replacement of all the internal worn out / defective parts i.e bushes, impellers, sleeves, upper and lower bush sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required.
Repair and rewinding of submersible / mono block pump motor set of above 3 HP and upto 7.5 HP Job include transportation of motor dismantling and rewinding with the same gage insulated copper wire including replacement of all the internal worn out / defective parts i.e bushes, impellers, sleeves, upper and lower bush sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required.
Annual maintenance, service contract of following UPS complete with all electrical, electronic, mechanical, equipment, safety controls and instrumentations with all associated systems including all minor spare parts carrying out preventive / scheduled maintenance as per OEM's & AAI recommendations etc., as required.
For First Year Capacity: 80 KVA, Make: Power One 1 visit - 1 Job (Quarterly visit per year - 4 visit)
For First Year Capacity: 80 KVA, Make:Numeric 1 visit - 1 Job (Quarterly visit per year - 4 visit)
For Second Year Capacity: 80 KVA, Make: Power One 1 visit - 1 Job (Quarterly visit per year - 4 visit)
For Second Year Capacity: 80 KVA, Make:Numeric 1 visit - 1 Job (Quarterly visit per year - 4 visit)
Annual comprehensive maintenance service contract of Technocrat make sliding gate & boom barrier by carrying out one mandatory visit in quarterly and attending any number of breakdown calls in additional to quarterly visit Job include all electrical, electronic, mechanical, equipment, safety controls and instrumentations with all associated systems including all minor spare / worn out / defective parts (excluding gate & boom barrier), carrying out preventive maintenance as per OEM & AAI recommendations etc. as required. a). Sliding gate of size 6.10 Mtr x 2.02 Mtr - 01 No. b). Boom barrier of size 5.10 Mtr - 01No.
1st Year
2nd Year
Calibration of tools from Electronics Test & Development Centre For First Year
Calibration of True RMS Multimeter of the maximum rating of 20A, 1000V, 40M.Ohms, AC/DC TRMS Make :FLUKE Model no:179 EJKCT, including adjustment of settings as required
Calibration of Digital clamp meter of the maximum rating of 1000A, 1000V, 60M.Ohms AC/DC TRMS Make :Fluke Model No : 376, including adjustment of settings as required
Calibration of Digital insulation tester of the maximum rating of with setting 500V & 1000V and maximum rating of 1000V, 50MW Make : Fluke Model No : 1507-1kV, including adjustment of settings as required
Calibration of AC Digital Earth Tester the maximum range 20V, 2000W Make : Fluke , Model No : 1621 kit,including adjustment of settings as required
Calibration of tools from Electronics Test & Development Centre For Second Year
Calibration of True RMS Multimeter of the maximum rating of 20A, 1000V, 40M.Ohms, AC/DC TRMS Make :FLUKE Model no:179 EJKCT, including adjustment of settings as required
Calibration of Digital clamp meter of the maximum rating of 1000A, 1000V, 60M.Ohms AC/DC TRMS Make :Fluke Model No : 376, including adjustment of settings as required
Calibration of Digital insulation tester of the maximum rating of with setting 500V & 1000V and maximum rating of 1000V, 50MW Make : Fluke Model No : 1507-1kV, including adjustment of settings as required
Calibration of AC Digital Earth Tester the maximum range 20V, 2000W Make : Fluke , Model No : 1621 kit,including adjustment of settings as required
Execution of items of schedule of rates CPWD DSR-2018 as and when required for attending breakdowns, repair & maintenance and upkeep of internal and external electrical installations as per direction of E-I-C at different locations in operational area/OTB/Colony as per the special Terms and Conditions in addition to General Terms and Conditions of Contract as required. The bidder shall quote the rate for 01 (one) job corresponding to the value of Rs.4,00,000/- (Ex.GST) in INR only and percentage (%) above / below shall be calculated by AAI and paid accordingly. Note: The rate provided in DSR 2018 is inclusive of GST @12%, however the contractor has to quote the amount in rate column, excluding GST, the payment shall be made to contractor as mentioned in special conditions of tender document. For First Year
Execution of items of schedule of rates CPWD DSR-2018 as and when required for attending breakdowns, repair & maintenance and upkeep of internal and external electrical installations as per direction of E-I-C at different locations in operational area/OTB/Colony as per the special Terms and Conditions in addition to General Terms and Conditions of Contract as required. The bidder shall quote the rate for 01 (one) job corresponding to the value of Rs.4,00,000/- (Ex.GST) in INR only and percentage (%) above / below shall be calculated by AAI and paid accordingly. Note: The rate provided in DSR 2018 is inclusive of GST @12%, however the contractor has to quote the amount in rate column, excluding GST, the payment shall be made to contractor as mentioned in special conditions of tender document. For Second Year
DElite System Engineering (India) Pvt. Ltd.
VOLTECH O AND M SERVICES PVT LTD
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .