Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC H NO 670 SECTOR 10 PANCHKULA HRY 134115 | PANCHKULA | HARYANA | 134115 | ₹29.9 L Quoted ₹30.9 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹32.7 LRejected-AOC 67 MANNUGANJ HAKIKAT RAI NAGAR DEHRADUN 248001 UK | DEHRADUN | UTTARAKHAND | 248001 | ₹32.7 L | L2 | Rejected-AOC Rejected |
| 3 | L3₹33.6 LRejected-AOC 4 3 KISHANPUR RAJPUR ROAD DEHRADUN UK | ₹33.6 L | L3 | Rejected-AOC Rejected |
| 4 | L4₹34.4 LRejected-AOC VILLAGE POST ATAL TYUNI CHAKRATA DEHRADUN UK PIN 248199 | DEHRADUN | UTTARAKHAND | 248199 | ₹34.4 L | L4 | Rejected-AOC Rejected |
| 5 | L5₹36 LRejected-AOC WING NO 7 2 10 PREM NAGAR DEHRADUN UTTARAKHAND DEHRADUN 248 007 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248007 | ₹36 L | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | M/S RAJESH AGARWAL L3 | M/s Teg Singh Negi L7 | M/S S P BUILDERS L5 | IMPERIAL ENGINEERS L1 | M/S J R S CONSTRUCTION L6 | avtarsinghchaddha L2 | M/s Yashwant Singh L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. | 5 | Cum | 20 ₹100 | 111 ₹555 | 100 ₹500 | 150 ₹750 | 99 ₹495 | 333 ₹1,665 | 100 ₹500 |
| 2.00 | Material and labour for brick work with sub class 'B' brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. | 5 | Cum | 3,000 ₹15,000 | 4,444 ₹22,220 | 3,500 ₹17,500 | 2,800 ₹14,000 | 2,600 ₹13,000 | 3,433 ₹17,165 | 4,500 ₹22,500 |
| 3.00 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. | 230 | Sqm | 10 ₹2,300 | 11 ₹2,530 | 10 ₹2,300 | 6 ₹1,380 | 10 ₹2,300 | 39 ₹8,970 | 30 ₹6,900 |
| 4.00 | Material and labour for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:6, surface finished even and smooth (without using extra cement) complete all as specified and directed. | 100 | Sqm | 150 ₹15,000 | 150 ₹15,000 | 150 ₹15,000 | 120 ₹12,000 | 180 ₹18,000 | 163 ₹16,300 | 220 ₹22,000 |
| 5.00 | Material and labour for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:4, surface finished even and fair (without using extra cement) complete all as specified and directed. | 100 | Sqm | 170 ₹17,000 | 160 ₹16,000 | 150 ₹15,000 | 125 ₹12,500 | 200 ₹20,000 | 163 ₹16,300 | 250 ₹25,000 |
| 6.00 | Material and labour for 10mm thick rendering on brick work or concrete surface in cement mortar 1:3 surface finished and smooth as in ceiling complete all as specified and directed. | 50 | Sqm | 170 ₹8,500 | 180 ₹9,000 | 150 ₹7,500 | 125 ₹6,250 | 180 ₹9,000 | 183 ₹9,150 | 180 ₹9,000 |
| 7.00 | Material and labour for preparation of newly plastered surface of walls including corners and applying two coats of distemper oil emulsion over applying one coat of 1mm wall care putty finish wall surface even & smooth all as specified and directed. | 100 | Sqm | 26 ₹2,600 | 80 ₹8,000 | 30 ₹3,000 | 20 ₹2,000 | 50 ₹5,000 | 43 ₹4,300 | 30 ₹3,000 |
| 8.00 | Material and labour for two coats of exterior grade 1st quality weather coat paints over a coat of alkali resistant priming paint over applying of 1-2 mm thick wall care putty finish wall surface even and smooth including preparation of new plaster external surfaces of wall etc with scrap wire brush and washing with water complete all as specified and directed. | 100 | Sqm | 28 ₹2,800 | 100 ₹10,000 | 40 ₹4,000 | 50 ₹5,000 | 70 ₹7,000 | 73 ₹7,300 | 40 ₹4,000 |
| 9.00 | Material and labour for preparation of newly plastered surface of wall and applying two coat of cement base paint over a coat of primer complete all as specified and directed. | 50 | Sqm | 18 ₹900 | 40 ₹2,000 | 25 ₹1,250 | 10 ₹500 | 20 ₹1,000 | 43 ₹2,150 | 20 ₹1,000 |
| 10.00 | Material and labour for preparation of newly plastered surface of ceiling and applying two coat of oil bound distember over one coat of 1mm wall care putty finish surface complete all as specified and directed. | 50 | Sqm | 16 ₹800 | 80 ₹4,000 | 30 ₹1,500 | 18 ₹900 | 50 ₹2,500 | 43 ₹2,150 | 32 ₹1,600 |
Updated dates
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
3 Mar 2026, 6:00 pmClosed
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Welcome Maintenance of Md and FAFA Accns under AGE B/R-II of GE Dehradun
2026_MES_750611_2
8130/A/E8
Open Tender
Civil Works
180 days
GE Dehradun
Class D cat a (i)
8 documents required · 8 mandatory
₹500
GE Dehradun
₹80,000
Yes
17 Mar 2026
12 Feb 2026
5 Mar 2026
12 Feb 2026
3 Mar 2026
18 Feb 2026
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Material and labour for brick work with sub class 'B' brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
Material and labour for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:6, surface finished even and smooth (without using extra cement) complete all as specified and directed.
Material and labour for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:4, surface finished even and fair (without using extra cement) complete all as specified and directed.
Material and labour for 10mm thick rendering on brick work or concrete surface in cement mortar 1:3 surface finished and smooth as in ceiling complete all as specified and directed.
Material and labour for preparation of newly plastered surface of walls including corners and applying two coats of distemper oil emulsion over applying one coat of 1mm wall care putty finish wall surface even & smooth all as specified and directed.
Material and labour for two coats of exterior grade 1st quality weather coat paints over a coat of alkali resistant priming paint over applying of 1-2 mm thick wall care putty finish wall surface even and smooth including preparation of new plaster external surfaces of wall etc with scrap wire brush and washing with water complete all as specified and directed.
Material and labour for preparation of newly plastered surface of wall and applying two coat of cement base paint over a coat of primer complete all as specified and directed.
Material and labour for preparation of newly plastered surface of ceiling and applying two coat of oil bound distember over one coat of 1mm wall care putty finish surface complete all as specified and directed.
Material and labour Complete removal of existing treatment to wall and applying one coat of wall putty 1mm thick (internal or external ) on walls internal applying two coats of oil bound distemper on internal wall putty surfaces in any height complete all as specified and directed.
Material and labour for preparation of old plastered/ treated surfaces of wall and applying one coats of oil bound distemper complete all as specified and directed.
Description all as per itme No 12 but 02 coats of oil bound distemper, complete all as specified and directed.
Material and labour Preparation old treated surfaces of walls and applying two coats of white wash complete all as specified and directed.
Material and labour Preparation old treated surfaces of ceiling and applying one coat of oil bounnd distember complete all as specified and directed.
Material and labour Preparation old treated surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
Material and labour for preparation of old decorated surfaces of walls and applying one coat of cement base paint in any tint complete all as specified.
Material and labour for preparation of old painted surfaces of wood of any description over 10 cm width or girth and applying one coat of synthetic enamel Paint complete all as specified and directed.
Material and labour for applying one coat of synthetic enamel paint on old painted steel surfaces/concrete surface of any description including preparation complete all as specified and directed.
Material and labour for vitrified ceramic coloured tiles 8-9 mm thick dark shed (square/rectangular) polished area of each tiles not exceeding 0.72 sqm, in floor etc. set and jointed in neat cement slurry @ 3kg/sqm and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 and dismantling of existing floor tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Description all as per item No 20 here in above but as in skirting and including 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed.
Material and labour for glazed ceramic colour tiles size 300 mm x 450 mm/ 300 mm x 600mm x 6-7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry @ 3kg/sqm and pointed in coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 and dismantling of existing wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Material and labour for non-skid / mat finish designed coloured joint free ceramic tiles of size not less than 400 mm x 400 mm x 6-7 mm thick in floor, set and jointed in neat cement slurry @ 3kg/sqm and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:6 and dismantling of existing tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Description all as per item No 23 here in above but as in skirting and including 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed.
Material and labour for 18-20 mm thick Granite, of any type, table rubbed and polished in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with the shade of granite including moulding complete and demolition of old stone slabs all as specified and directed.
Demolition of Cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and directed.
Material and labour 25 mm thick PCC 1:2:4 type B-0 using 12.50 mm graded stone aggregate as in leveling course to floors complete all as specified and directed.
Material and labour for 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement complete all as specified and directed.
Material and labour for 75mm thick cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed.
Material and labour for heavy duty endura ceramic coloured tiles 9-10 mm thick dark shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floor etc. set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
Material and labour polished rubber moulded coloured machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming IS 15658-2006 of 60mm thickness, M-35 grade laid over and incl 25mm thick sand cushioning complete all as specified and directed.
Material and labour for rubber moulded coloured glossy finish cement concrete chequered tiles of size 30cm X 30cm X 20mm thick jointed in neat cement slurry and pointed in white or coloured cement and pigment to match the surface of tile as in floor over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed
Material and labour for cement concrete type B1 1:2:4 (20mm graded aggregate) as in window or door cills, lintels, copings. kneelers, apex stones, posts, boundary pillars, bonders (for stone walling), brackets, etc. with plain fair faces, including chamfers, weatherings, throating etc. complete all as specfied and directed.
Taking down chowkhats or frames exc 1.5 sqm and n.exc 4 sqm each (without taking off shutters from the frame) and removing from the site complete all as specified and directed.
Description all as per ser Item No 34 above but n.exc 1.5 sqm each complete all as specified and directed.
Taking down shutters of any description exc 1.0 sqm and n.exc 2.0 sqm each and removing from the site complete all as specified and directed.
Supply and fixing in Aluminum powder coated fixed type windows including suitable nylon beading channel gasket etc complete with following specification :- Frame :- 60mmx40mmx1.50mm Panel :- 4mm thick ACP sheet / 4mm thick tinted/frosted glass of approved colour and design
Supply and fixing 30mm thick second class hardwood glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge complete all as specified in SSR Pt I-2009 section 8 clause 8.24 (a) complete all as specified and directed.
Supply and fix stainless steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with rails complete all as specified and directed.
Supply and fixing 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
Material and labour for applying two coats of Synthetic enamel paint on new wooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and directed.
Supply and fix factory made 100 % solid wood plastic composite (WPC) door frame 125x60 mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termiteproof, fire retardant and having good screw holding capacity all as per specification and drawing complete all as specified.
Supply and fix factory made 100 % solid wood plastic composite (WPC) door frame 105x60 mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termiteproof, fire retardant and having good screw holding capacity all as per specification and drawing complete all as specified.
Supply and fixing 30 mm thick moulded WPC factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side plain with density not less than 600 Kg/cum. Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fire etardant and having screw holding capacity complete all as specified.
Supply and fixing 30 mm thick WPC factory made Glazed and skeleton shutter (conforming as per IS-4020) made from 100% lead free single extruded open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge with density not less than 600 Kg/cum. Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fire retardant and having screw holding capacity complete all as specified
Supply and fixing PVC solid factory made door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS Square tube, supplying & fixing in opening, as per specification and drawing complete all as specified and directed.
Supply and fixing Factory made solid panel PVC door shutter 24 to 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded both side prelam PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side prelam PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of both side prelam PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement as per specification & drawing complete all as specified and directed.
Supply and fixing for stainless steel Butt Hinges medium weight, cold rolled mild steel 100 mm fixed to steel/wooden shutters complete all as specified and directed.
Supply and fixing for stainless steel barrel tower bolts 150 mm size, stove enamelled black, with bright bolt fixed in repairs complete all as specified and directed.
Supply and fixing for stainless steel pressed handles 150 mm size stove enamelled black complete fixed complete all as specified and directed.
Supply and fixing for stainless steel sliding door bolts 'bolt type' 250 mm size stove enamelled black with and including 6 nuts and bolts complete fixed all as specified and directed.
Supply and fix in repair stainless steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with rails complete all as specified and directed.
Hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/springs clips complete all as specified and directed.
Supply and fixing for Glazing with plain sheet glass, ordinary quality, 3 mm thick and glazing with oil putty or aluminium or PVC beading in squares not exceeding 0.5 Sq.m in each pane, complete all as specified and directed
Supply and fixing for Glazing with plain/tinted sheet glass, ordinary quality, 5.5 mm thick and glazing with oil putty or aluminium or PVC beading in squares not exceeding 0.5 Sq.m in each pane, complete all as specified and directed
Supply and fixing for Glazing with plain sheet glass, ordinary quality, 5.5 mm thick and glazing with oil putty or aluminium or PVC beading in squares exceeding 0.5 Sq.m in each pane, complete all as specified and directed.
Supply and fixing for Glazing with frosted sheet glass, ordinary quality, 3 mm thick and glazing with oil putty or aluminium or PVC beading in squares not exceeding 0.5 Sq.m in each pane, complete all as specified and directed
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness incl cover fillets complete all as specified and directed.
Supply and fixing of 18 mm thick PVC board one side prelaminated, density 600 and other side plain white colour as in cup board shutters and frames, kitchen cabinet front shutter, partion, shelf, & drawer, fixed with screws, solvent cement / adhesive complete all as specified and directed by the Engineer-in-Charge.
Supply & fix 6 mm thick PVC board both side plain white colour as in cub board selves etc fixed with screws, salvent cement/ adhessive , complete all as per specifications & directed.
Supply and fixing magnetic catcher and striking plate including letting in and fixed complete all as specified and directed.
Supply and fixing Continuous (PIANO) hinges, mild steel, bright finish or electrogalvanised 30 mm width of flaps (when open) complete all as specified as directed.
Supply and fixing D-type cabinet handles premium quality, stainless steel 304/gloss chrome/SN finished 150mm long matt finished complete fixed in position all as specified. Make Hettich/Harrison/Dorsel as approved by EIC/GE
Supply and fixing in repair chrome plated stainless steel wire basket (storage basket) pull out type for large utensils of size 480 x 500 x 150 mm of grade 304 with necessary fixing clips etc. complete all as specified and as directed.
Supply and fixing in repair chrome plated stainless steel wire basket (plate basket) pull out type for large utensils of size 380 x 500 x 100 mm of grade 304 with necessary fixing clips etc. complete all as specified and as directed.
Supply and fixing in repair chrome plated stainless steel wire basket (cutlery basket) pull out type for large utensils of size 380 x 500 x 100 mm of grade 304 with necessary fixing clips etc. complete all as specified and as directed.
Supply and fixing in repair chrome plated stainless steel wire basket (grain trolly basket) pull out type for large utensils of size 480 x 500 x 200 mm of grade 304 with necessary fixing clips etc. complete all as specified and as directed.
Supply and fixing in repair chrome plated stainless steel wire basket (bottle pull out basket) pull out type for large utensils of size 120 x 500 x 432 mm of grade 304 with necessary fixing clips etc. complete all as specified and as directed.
Repair to steel window of any size by replacing worn out hinges or worn out portion such as glazing bars, fitting and fixture positioning of shutters etc. and cleaning the window surrounding and renewal of fitting and fixture (unserviceable) including greasing, oiling complete all as specified and directed.
Resecuring or easing and adjusting without taking down shutters of any description exc 1 sqm and n exc 2 sqm each, complete all as specified and directed.
Supply and fixing in repair SS grade 204 drapery rod 20mm dia including decorative brackets, decorative finals at both ends complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Supply and fixing for prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Supply and fixing for prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick (AZ-150) of an ecofriedly colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.
Dismantling of timber scantlings 40 sq cm and over in section in any position in unframed work complete all as specified and directed.
Supply and fixing for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410-W(Gde E-250) quality-A complete all as specified and directed.
Supply and fixing of mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; staircase; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 including necessary welding, drilling hole complete all as specified and directed.
Material and labour for two coats of synthetic enamel paint over a coat of red oxide primer on new or previously untreated steel surfaces of any description over 10 cm width or girth including preparation of steel surfaces complete all as specified and directed.
Supply and fixing in repairs Vitreous China wash down water closet pan, white including Plastic water closet seat, black, closed pattern with flat bottom, cover and mild steel chormium plated or aluminised hinging device complete all as specified and directed.
Supply and fixing in repairs vitreous China squatting pan, 'Orissa' pattern, size 580 x 440 mm white, with integral foot rests including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor and fixed complete all as specified and directed.
Supply and fixing in repairs PVC valveless, syphonic action type flushing cistern (Dual action ISI Marked), low level , white, with inlet ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC 32 mm dia for low level cistern for 10 litres capacity of approved make .Complete all as specified and directed
Supply and fix in repair vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and directed.
Supply and fixing in repairs angle stop valve cast copper alloy screwed down high presure screwed both end for iron pipe 15 mm dia fancy type cromium plated (ISI Marked) complete all as specified and directed.
Supply and fixing in repair brass CP bib tap 15mm bore fancy type screwed for iron pipe complete with wall flange complete all as specified and directed.
Supply and Fixing in repairs 15 mm bore Pillar cocks chromium plated brass with capstain head screwed down high pressure complete all as specified and directed.
Supply and fixing in repair health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections fixed in position complete in all respect as specified and directed .
Supply & fix wall mixer with over head shower chromium plated for mixing hot and cold water screwed for iron pipe suitable for 15 mm bore pipes complete all as specified and directed .
Supply and fixing in repair 15mm dia brass CP sink mixer with swinging spout (wall mounted model) with connecting legs and wall flanges screwed down for iron pipe and fixed complete all as specified and directed.
Supply and fixing in repair 15mm dia chromium plated central hole wash hand basin mixer without PWS with 450mm BRAIDED HOUSE hose screwed down high pressure screwed for iron pipe completed all as specified and directed.
Supply & fix in repair front glass shelf assembly consisting of 5.5 mm thick toughened glass with CP railing and brass brackets of size 500x125 mm complete all as specified and directed.
Supply and fixing corner self 300mm radius of 10mm thick toughened glass with CP railing with bracket Supply and fixingixed with brass screw complete all as specified and directed .
Supply and fixing in repair CP shower rose with or without swivel joints of 125 mm size with shower arm including fixing to steel pipe or union complete all as specified and directed
Supply and fixing in repair CP Grating doom 125mm dia with/without waste hole of steel fixed on floor/nahani trap with cement mortar, complete all as specified and directed.
Supply and fixing in repair CP toilet paper holder with flat recessed type stainless steel fixed to wall with CP brass screw complete all as specified and directed.
Supply and fixing in repair cast copper alloy, chromium plated Towel Rail 20 mm dia, D-type, 600 mm long fixed with and including Chromimum plated brass screws and wooden plastic cleats Complete all as specified and directed .
Supply and fixing in repair for SS towel ring of standard quality complete all as specified and directed.
Supply and fixing in repair SS soap dish fixed to wall with screw complete all as specified and directed.
Supply and fixing in repair medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 15 mm bore GI tubing including dismantling of old tubing complete all as specified and directed.
Supply and fixing in repair medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 20 mm bore GI tubing including dismantling of old tubing complete all as specified and directed.
Supply & Fix in repairs PVC connection 15 mm dia 450 mm long with brass fly nut at both ends complete all as specified and directed.
Taking down CI/AC/PVC pipes incl fittings upto 110mm dia and removing from site complete all as specified and directed.
Supply and fixing PVC (SWR) pipes of 110 mm dia, single socketed fixed to walls or laid in trenches or floors complete all as specified and directed.
Supply and fixing PVC (SWR) pipes of 75 mm dia, single socketed fixed to walls or laid in trenches or floors complete all as specified and directed.
Supply and fixing PVC (SWR) bends of 110 mm dia, any radius complete all as specified and directed.
Supply and fixing PVC (SWR) bends of 75 mm dia, any radius complete all as specified and directed.
Supply and fixing PVC (SWR) junction single Tee equal or unequal 110 mm dia complete all as specified and directed.
Supply and fixing PVC (SWR) junction single Tee equal or unequal 75 mm dia complete all as specified and directed.
Supply and fixing rotational moulded polyethylene water storage tanks capacity of tank 500 litres tripple layer, white colour, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including dismantling of existing unserviceable tank and removing from site complete all as specified and directed.
Supply and fixing rotational moulded polyethylene water storage tanks Capacity of tank 1000 litres tripple layer, white colour, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including dismantling of existing unserviceable tank and removing from site complete all as specified and directed.
Supply and fixing in repair PTMT Ball valves 20 mm bore, high pressure with epoxy coated Aluminium rods & high density plastic ball screwed and fixed complete all as specified and directed.
Supply and fixing in repair heavy duty thread type PVC water tank cover with fixing frame fixed on PVC tank with 4 Nos of screws for 500/1000 ltrs tank complete all as specified and directed.
Supply and fixingin repair for hollow PVC wall lining consisting of 5 mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing complete all as specified and directed.
Material and labour for providing & fixing false ceiling of Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grams, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and cross 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable wire of 4mm dia with galvanised butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 4mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width complete all as specified and directed.
Supply and fixing galvanised iron sheet 1.2mm thick cut in circular shapes of size 450mm dia and bent to the shape of cover of PVC overhead tank with edges turned. Spikes made of 1.2mm thick GI sheet cut in triangular shape with sharp edge 50mmx25mm size bent and fixed to circular sheet with rivets at 100mm c/c spacing bothways. The sheet with spikes shall be fitted to overhead tank with 4 Nos self tightening screws complete all as specified and directed.
Material and labour for taking down of existing sunken slab treatment from the sunken portion (Area n.exc 2 Sqm) and cleaning the surfaces washing down with water and rubbish of the premises, cleaning and filling cracks with sealing compound, brushing neat cement slurry @ 3.00Kg/Sqm and gouting 25mm thick cement concrete type B-0 (1:2:4) (using12.5mm graded stone aggregate) on sunken slab portion and finishing the top surfaces even and smooth without using extra cement . (b) Material and labour for two coat of acrylic cementitious water proofing coating (Dr FIXIT pidifin 2K manufactured by M/S Pidilite Industries Ltd or equivalent) and followed by a overlay protective screed (15mm thick CM 1:3 alongwith liquid water proofing compound approved make) on top surfaces of sunken slab after preparations as mentioned above method of application for acrylic cementitious water proofing coating is followed as per manufactures instructions, complete all as specified and directed.
Material and labour for cleaning of water storage tank capacity exceeding 500 litres but not exceeding 1000 litres, mechanically using pressure pump with disinfectant chemical including cleaning & removing all scale & dirt etc from existing tanks, mouths of circulating pipes and outer surface of any description & washing down in the manner and marking the outer surface of overhead tank with synthetic enamel paint using stancils (Date of cleaning month & Year) complete all as specified and directed.
Material and labour for cleaning of water storage tank capacity not exceeding 500 litres, mechanically using pressure pump with disinfectant chemical including cleaning & removing all scale & dirt etc from existing tanks, mouths of circulating pipes and outer surface of any description & washing down in the manner and marking the outer surface of overhead tank with synthetic enamel paint using stancils (Date of cleaning month & Year) complete all as specified and directed.
One light point, controlled by one way switch, complete all as specified and directed.
One fan point, controlled by one way switch through regulator, complete all as specified and directed.
One bell point, controlled by bell push switch, complete all as specified and directed.
One three pin 5 Amp socket on same board with other switches, complete all as specified and directed.
One three pin 5 Amp socket on independent board, complete all as specified and directed.
Two way light point controlled by two two way switch, complete all as specified and directed.
Description all as per Item No 120 mentioned here-in- before but one three pin 15 Amps switch socket outlet on the independent board with 2.5 sq mm PVC insulated FRLSH copper conductor and 2.5 Sqmm FRLSH copper conductor for continuous earthing complete all as specified and directed.
Material and labour for point wiring using approved colour coding as per IS, with 1100 Volts, grade 1.5 Sqmm (nominal area), PVC insulated but unsheathed multistranded copper conductor single core FRLSH cable drawn through existing concealed conduit of any size or type complete including factory made MS pressed modular metal flush boxes with zinc coated duly concealed in wall of thickness 1.2 mm for mounting of modular switches, sockets, fan regulators etc including logic modular white frame with cover plates of suitable size/module as required at site and 1.5 sqmm (nominal area) single core FRLSH, PVC insulated 1100 Volts, grade multi stranded unsheathed FRLSH copper conductor cable green colour as earth wire upto common earth and connected to earth dolly including cutting chases for conduits and sunken boxes including taking down existing unserviceable copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc as existing for the followings: Note : The wiring to be done as per IE rule and as per colour code.
One light point, controlled by one way switch,complete all as specified and directed.
One fan point, controlled by one way switch through regulator, complete all as specified and directed.
One bell point, controlled by bell push switch, complete all as specified and directed.
One three pin 5 Amp socket on same board with other switches, complete all as specified and directed.
One three pin 5 Amp socket on independent board, complete all as specified and directed.
Two way light point controlled by two two way switch, complete all as specified and directed.
Description all as per Item No 121 mentioned here-in- before but one three pin 15 Amps switch socket outlet on the independent board with 2.5 sq mm PVC insulated FRLSH copper conductor and 2.5 Sqmm FRLSH copper conductor for continuous earthing complete all as specified and directed.
One light point, controlled by one way switch, complete all as specified and directed.
One fan point, controlled by one way switch through regulaor, complete all as specified and directed.
One bell point, controlled by bell push switch, complete all as specified and directed.
One three pin 5 Amp socket on same board with other switches, complete all as specified and directed.
One three pin 5 Amp socket on independent board, complete all as specified and directed.
Description all as per Item No 122.00 mentioned here-in- before but one three pin 15 Amps switch socket outlet on the independent board with 2.5 sq mm PVC insulated FRLSH copper conductor and 2.5 Sqmm FRLSH copper conductor for continuous earthing complete all as specified and directed.
Material and labour for point wiring using approved colour coding as per IS, with 1100 Volts, grade 1.5 Sqmm (nominal area), PVC insulated but unsheathed multistranded copper conductor single core FRLSH cable drawn through existing concealed conduit any type or size complete including pressed iron/steel suction box of thickness 1.2 mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm (nominal area) single core FRLSH, PVC insulated 1100 Volts, grade multi stranded unsheathed FRLSH copper conductor cable green colour as earth wire upto common earth and connected to earth dolly including cutting chases for sunken boxes after taking down existing unserviceable copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc as existing for the followings: Note : The wiring to be done as per IE rule and as per colour code.
One light point, controlled by one way switch, complete all as specified and directed.
One fan point, controlled by one way switch through regulator, complete all as specified and directed.
One bell point, controlled by bell push switch, complete all as specified and directed.
One three pin 5 Amp socket on same board with other switches, complete all as specified and directed.
One three pin 5 Amp socket on independent board, complete all as specified and directed.
Description all as per Item No 123.00 mentioned here-in- before but one three pin 15 Amps switch socket outlet on the independent board with 2.5 sq mm PVC insulated FRLSH copper conductor and 2.5 Sqmm FRLSH copper conductor for continuous earthing complete all as specified and directed.
2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, complete all as specified and directed.
2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, complete all as specified and directed.
Material and labour for sub main wiring with 2 single core wire for phase and neutral and one run of earth wire PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded drawn in existing concealed conduit any type or size including one single core green colour PVC insulated unsheathed cable FRLSH copper conductor multistranded as earth wire upto common earth and connected to earth dolly complete after taking out old unserviceable submain and making good disturbed surfaces of walls, floors, etc as existing for the followings sizes of wires all as directed. Note : (i) The wiring to be done as per IE rule and as per colour code. (ii) 3 run of cable shall be measured as 1 unit.
2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, complete all as specified and directed.
2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, complete all as specified and directed.
Supply and fixing of modular switch single pole one way, one module, 230 Volts 6 Amp complete all as specified and directed.
Supply and fixing of modular socket 6 Amps, 2/3 pin combined, two module, 230 Volts complete all as specified and directed.
Supply and fixing of modular switch single pole one way, one module, 230 Volts 16 Amp complete all as specified and directed.
Supply and fixing of modular socket 6/16 Amps, 2/3 pin combined, two module, 230 Volts complete all as specified and directed.
Supply and fixing of modular switch single pole two way, one module, 230 Volts 6 Amp complete all as specified and directed.
Supply and fixing of bell push modular flush type, single pole one way 6 Amps, one module, 230 volts complete all as specified and directed.
Supply and fixing of calling bell ding dong type AC 230 Volt single pole complete all as specified and directed.
Supply and fixing of lamp holder polycarbonate insulated body, with back plate suitable for batten fitting complete all as specified and directed.
Supply and fixing of step type modular fan regulator two module 5 step for ceiling fan 1200/1400 mm size 230 volts, 6 Amps 120 watts complete all as specified and directed.
Supply and fixing of modular ceiling rose, three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified and directed.
Supply and fixing of switch piano flush type single pole one way 230 Volts 6 Amp complete all as specified and directed.
Supply and fixing of socket outlet 3 pin, 230 Volts 5/6 Amps flush type multipurpose 5 pin complete all as specified and directed.
Supply and fixing of switch piano flush type, single pole, one way, 230 Volts 15/16 Amps complete all as specified and directed.
Supply and fixing of socket outlet multipurpose having provision for 3 pin, 230 Volts 15/16 Amp and 3 pin, 5/6 Amp, piano flush type complete all as specified and directed.
Supply and fixing of bell push flush type 5 Amps 230 Volts single pole complete all as specified and directed.
Supply and fixing of ceiling rose, three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified and directed.
Supply and fixing of energy efficient LED tube light fittings 20 Watts, 230 volts with efficiency of not less than 100 lumens per watt, PC extruded body with PC diffuser including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing of energy efficient LED tube light fittings 10 Watts, 230 volts with efficiency of not less than 100 lumens per watt, PC extruded body with PC diffuser including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing of LED Bulk head light fitting 10 Watt capacity die cast alluminum including surface mounted, with decorative oval diffuser comprrising of high brightness LEDs complete all as specified and directed.
Supply and fixing of LED building security light fitting 35 Watt 230 Volts, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including bracket made out of 32 mm bore medium grade GI pipe made to shape with bolts, nuts & washers of min 1.2 mtr including grouting of nuts or fasteners clamps and conductor to fitting with 3 core 1.5 sqmm PVC insulated cable complete all as specified including taking out old u/s fitting complete all as specified and directed.
Supply and fixing of distribution board SPN 8 Way double door, for mounting MCBs isolator, ELCBs etc factory made fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar 100 Amps rating of IP 43 protection and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing MCB DB etc complete all as specified and directed. Note:- DB and MCCB/MCB shall be of same make.
Supply and fixing of distribution board SPN 12 Way double door, for mounting MCBs isolator, ELCBs etc factory made fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar 100 Amps rating of IP 43 protection and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing MCB DB etc complete all as specified and directed. Note:- DB and MCCB/MCB shall be of same make.
Supply and fixing of distribution board Triple pole and neutral double door 415 Volt 4 way DBs IP-43 suitable for 160 Amps rated bus bar and also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing MCCB DB etc complete all as specified and directed. Note:- DB and MCCB/MCB shall be of same make.
Supply and fixing of distribution board vertical Triple pole and neutral double door 415 Volt 4 way DBs IP-43 IK- 09 Vertical type suitable for 160 Ams rated bus bar & including one MCCB 100 Amp 4 pole as incoming iand also incoming and outgoing connections with suitable size of lugs/thimbles/glands including taking down existing MCCB DB etc complete all as specified and directed. Note:- DB and MCCB/MCB shall be of same make.
Supply and fixing of MCB single pole and neutral 240 volt 10 KA 40 Amp 'C' series conforming to ISI marked including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of MCB single pole and neutral 240 volt 10 KA 32 Amp 'C' series conforming to ISI marked including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of MCB single pole 240 volt 10 KA 6- 32 Amp 'C' series conforming to ISI marked including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing of MCB TPN 415 volt 10 KA 63 Amp 'C' series conforming to ISI marked including connection with suitable size copper lugs complete all as specified and directed.
Supply and fixing BLDC ceiling fan complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated PVC AC single Phase 230 V / 240V 50 Hz complete all as specified and directed. Note : Old fan shall be deposited to AGE E/M-II store yard and necessary RV enclosed with RAR and final bill.
Supply and fixing of exhaust fan, steel body AC single Phase, 230V of size 300m sweep with, blades, and frame and louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep complete and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed. Note : Old fan shall be deposited to AGE E/M-II store yard and necessary RV enclosed with RAR and final bill.
Description all as per item No 155.00 above but fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm, complete all as specified and directed. Note : Old fan shall be deposited to AGE E/M-II store yard and necessary RV enclosed with RAR and final bill.
Supply and fixing of electric water heater, storage type ABS body with EPAC coated steel inner tank having minimum 8 kg/cm2 pressure bearing capacity and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed. Note : Old geyser shall be deposited to AGE E/M-II store yard and necessary RV enclosed with RAR and final bill.
Material and labour in replacement for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with a 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00mm dia by means of bolts, nuts, Check nuts and washers of galvanised iron and thimbles and other end of the earth wire all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board and protected by galvanized iron pipe medium 15 mm bore, and water pipe 20 mm bore GI light grade with funnel and wire mesh, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) 75mm thick cover, reinforced with 8mm dia deformed or TMT bars 100mm C/C both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI light grade earth lead protection pipe etc complete all as specified and directed. NOTE: (i) Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted. (iii) If the desired earth resistance is not found within permissible limit shall be re done by contractor at no extra cost.
Material and labour for laying, jointing and testing of underground XLPE insulated & PVC sheathed, armoured heavy duty multistranded electric cable with aluminium conductor, 1100 volts grade in trenches/ ducts/ along poles/ through pipe/ under road/ PCC etc and connecting with new aluminium lugs including taking out existing unserviceable of any size/ type complete for the following cables of cross sectional area all as directed: Notes: (a) Excavation, returning, removal, sand cushioning, cable protection covers, GI protection pipe etc shall be measured and paid separately. (b) Any damage done during cable excavation to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses. (c) Cost of T&P required for handling/ laying of cable is deemed to be included in the rate quoted by the contractor.
10.0 Sqmm, 4 core, complete all as specified and directed.
16.0 Sqmm, 4 core, complete all as specified and directed.
25.0 Sqmm, 4 core, complete all as specified and directed.
Excavation in trenches in any type of soil not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for laying of cable, foundation etc and getting out complete all as specified and directed.
Material and labour for sand cushioning & covering of UG cable using crushed metal sand in trenches for cable protection complete all as specified and directed.
Material & labour for sub class B bricks well burnt of size 23 x 11.5 x 7.5 cm for protection of UG cable laid dry flat over the cable width wise across the length of the cable and abutting each other with gap less than 10mm between the adjacent bricks in trenches complete all as specified and directed.
Returning, filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and directed.
Removing of excavated soil to a distance n exc 50 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and laying GI tubing light grade with all fittings and accessories for protection of cables on ploe/ wall or under road crossings including clamps, nuts, bolts etc of size 50 mm complete all as specified and directed.
NOTE:- Amount of credit of Rs. 91712.00 for retrieved materials is mentioned in Schedule of Credit Page No 36 & 37 of tender documents in pdf form which will be deducted offline while acceptance of tender.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
8130Tenderdocuments.pdf
Tender Documents • 1.50 MB
BOQ_842820.xls
BOQ • 4.07 MB
Download all tender documents and submit your bid