| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC HOUSE NO 413 MAGADH COLONY SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | L1 | Accepted-AOC Bid is lowest and reasonable | |
| 2 | L2₹30.4 L+₹3.5 L (12.8%)Rejected-AOC VIKASH NAGAR ROAD NO 1 NEAR GAUSHALA RAMGARH CANTT JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L2 | Rejected-AOC Bid is not lowest and reasonable | |
| 3 | L3₹31.8 L+₹4.9 L (18.0%)Rejected-AOC Q 49 NEAR DEOGHAR COLLEGE MAIN GATE PO PS DEOGHAR JH 814112 | DEOGHAR | DEOGHAR | JHARKHAND | 814112 | L3 | Rejected-AOC Bid is not lowest and reasonable | |
| 4 | L4₹32.9 L+₹6.0 L (22.1%)Rejected-AOC | L4 | Rejected-AOC Bid is not lowest and reasonable | |
| 5 | L5₹33.3 L+₹6.3 L (23.3%)Rejected-AOC 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L5 | Rejected-AOC Bid is not lowest and reasonable |
Tender Value
Refer Docs
EMD Value
₹75,640
Closing Date
23 Sept 2023, 6:00 pmClosed
GE RAMGARH
GE RAMGARH
SPECIAL REPIAR TO BLDG NO P484 AND BLDG NO P94 ROOF TREATMENT ONLY AT PRC RAMGARH CANTT UNDER GE RAMGARH
2023_MES_614777_1
8300/3186/E8
Open Tender
Civil Works
Item Rate
180 days
GE RAMGARH
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE RAMGARH
₹75,640
Yes
2 Nov 2023
21 Aug 2023
30 Sept 2023
21 Aug 2023
23 Sept 2023
16 Sept 2023
Amount
Taking down complete existing roof /parapet treatment any thickness including plastering, leaping plaster of any thickness cuting & up rooting tree roots/Vegitable growth & removing the debris from the premises upto 500 m from the MOD land including cleaning/washing down and keeping surfaces clean complete all as specified and as directed.
M & L for brushing neat cement slurry (@ 3 Kg of cement per Sqm) mixed with water proofing compound in the proportion ,water proofing compound, water and cement (1:4:7) or as per manufacturer's instructions for bonding of old concrete surface to new concrete, complete all as specified and as directed. (Note:Water proofing compound shall be measured and paid seprerately under respective item of "BoQ")
M & L for plain cement concrete 1:2:4 ,type B-0 (using 12.5mm graded crushed stone aggregate) mixed with integral water proofing chemical compound, mixed in proportion 200 milli litre per 50 Kg of cement as in padding, benching, sunken portion etc., on roof surface for correcting/making proper slope on roof, etc.,complete all as specified and directed.
M&L Rendering 10 mm thick in cement mortar 1:4 on concrete / brick surfaces with liquid water proofing compound @ 200 ml/50 Kg per Bag of cement , finished, even and smooth without using extra cement over roof / sunken slab /wall complete all as specified and directed. Note:Water proofing compound will be measured and paid seprerately under respective item of "BoQ".
M & L for application of water proofing treatment using APP modified roof membrane over non accessible/non approachable RCC roof slab /chajjah/canopy /parapet wall( horizontal /vertical surface) to be executed through approved applicator of the membrane manufacturer/authorized applicator of the manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying approved bituminous based primer( conforming to IS: 3384-1995) @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface & a coat of hot blown grade bituminen softeng point 115 degree C @ 1.2 Kg/Sqm over primer . (c) Laying not less than 3mm thick APP (Atactic polypropylene Polymer modified prefabricated membrane) modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gms/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.00 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gms/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 150 Kg / Sqcm and transverse not less than 450 Kg /Sq.cm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP modified polymeric membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) Applying two coat of bituminious based Aluminium Paint @ 0.3 Kg /Sqm over APP Membrane.
M& L for applying evenly a tack coat of industrial hot blown grade bitumin 85/25 @ 1.2 Kg/Sqm including cleaning of surface complete all as specified & directed.
M & L for cement concrete (1:5:10), type E-2 (using 40 mm graded brick aggregate) as in filling in sunken portion, sub-base, etc.,complete all as specified and as directed.
S & F 50 mm bore GI tube, light grade as in spout pipe, complete with all fittings laid as in floor etc., complete all as specified and as directed.
Supply only liquid water proofing compound ISI marked. complete all as specified and directed.
Taking down chowkhats or frames with shutter (without taking off shutter from the frames) of any description not exceeding 1.5 Sqm each, complete all as specified and directed by Engineer-in-Charge .
Taking down chowkhats or frames with shutter (without taking off shutter from the frames) of any description exceeding 1.5 Sqm but not exceeding 4.0 Sqm each, complete all as specified and directed by Engineer-in-Charge .
Taking down shutters of any description exceeding 1.00 Sqm but not exceeding 2.0 Sq m each, and removing from site, complete all as specified and directed by Engineer-in-Charge .
Dismantling boarding, any description, fixed in any position with screws complete all as specified and directed.
S&F for 1.25 mm thick pressed steel door frames of size 125mm x 60 mm for single or double doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including plain cement concrete 1:3:6, type C-0 (using 12.5 mm graded crushed stone aggregate) as in filling in pressed steel door complete all as specified and directed. Note: The quoted unit rate under this item shall deemed to be included one shop coat of primer.
S & F 30 mm thick, factory made flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed .
S & F 35 mm thick, factory made, IInd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauze, etc. (divided into squares with plain, chamfered or rounded, mitred and rebated sash bars any number size of members), beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24 (a); kiln seasoned & chemically pressure treated etc complete all as specified and directed . Note:- (i)Glass / wire cloth shall be measured & paid separately. (ii) Sample of shutter in sample room of GE office.)
S&F steel window with side hung shutters including projecting type hinges with steel handles and steel peg stay complete with glazing bars, dovetailed or welded with four Nos mild steel flat iron 25 mm X 3mm ,200 mm length (appx) & two Nos mild steel tower bolt 200 mm long and one peg stay on each leaf complete all as specified and directed
S&F steel window with side hung shutters including projecting type hinges with steel handles and steel peg stay complete without glazing bars, dovetailed or welded with four Nos mild steel flat iron 25 mm X 3mm ,200 mm length (appx)& two Nos mild steel tower bolt 200 mm long and one peg stay on each leaf complete all as specified and directed
M&L taking down old steel window projecting type by machanical cutter and fixed in same opening by providing box type hinges 02 Nos in each shutter, not exceeding 1.00 sqm and making good disturbed surface, fineshing to match with existing surface & panting to distrubed portion all as directed by Engr-in-Charge.
S & F for steel windows or ventilators, fixed type, with glazing bars complete including prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
M&L for hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe -290 Gde E-165 complete all as specified & directed.
M&L for framed work such as grills,gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railing; framework of water tanks and similar work conforming to Fe 290- Gde E -165 & for portions framed and hung as gates, including pintle hinges, stops,hand-made sliding bolts, etc.complete all as specified and as directed
S & F solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tubes suppyling & fixing in opening as per specification & drawing complete all as spcefied and directed by Engineer-in-Charge.
S & F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails. mild steel framed shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail &bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS framed welded/sealed to stiles & rails with suitable PVC sheet beading & joined together with solvent cement complete all as fixing in the frame at site as per specification and drawing including 3 Nos stainless steel butt hinges 100 mm long for each door, complete all as specified and as directed.
S&F mild steel cupboard shutter with frame as Godrej pattern ,made out of 22 gauge mild steel sheet including chromium plated mild steel handle with proper locking arrangement (brass mortice lock vertical type size 65mm ,4 livers with escutcheon plates & two keys )with and including two coats of spray painting with synthethic enamel paint of approved tint over a coat of red oxide primer including fixing with 6 Nos 12 mm dia bolts 150mm long grouted in brick wall /concrete including makng good the disturbed surface as original complete all as specified and directed by Engineer-in-Charge. Make of brass mortice lock - Godrej/ Harrison/ Link
S&F 30mm width of flaps (when open) continues piano hinges mild steel bright finish or elec-trogalvanised complete all as specified and directed.
S&F 40mm dia cupboard knobs fixed with nut, screw and washer of mild steel with brass polish,bright finish complete all as specified and directed
S&F ball catcher with 8mm dia steel ball and brass body and striking plate including letting and fixed complete all as specified and directed
S & F in repair for Stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
M & L for 3mm thick plain sheet glass ordinary quality and glazing with oil putty not exceeding 0.50 Sqm in each pane,complete all as specified and as directed by Engineer-in-Charge .
S&F 3.0 mm thick figured glass pin headed type in squares/ rectangular not exceeding 0.5 Sqm in each pane glazing with oil putty or aluminium frame/shutters with rubber neoprene beading complete etc all as specified & directed.
S&F 125 mm size of hasp and staple safety type aluminium anodized hinges pin including bolt to hinges plate complete etc all as specified & directed.
S & F 100mm size butt hinges medium weight cold rolled stainless steel (SS) complete all as specified and directed
S & F 75 mm size butt hinges medium weight cold rolled stainless steel (SS) complete all as specified and directed
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed all as specified and directed.
S&F 125 mm long aluminium anodised barrel tower bolts of extruded section and fixed all as specified and directed.
S&F 125 mm aluminium alloy handles of extruted section type, anodised complete all as specified & directed.
S & F aluminium sliding door bolts 250mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections and fixed, complete all as specified and directed by Engineer-in-Charge .
S&F in repair mild steel 200 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed.
S & F 150 mm (overall length of cover plate) floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring,fixed in floor complete all as specified & directed.
M&L plain cement concrete 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) in for inserting hold fast of doors & window & similar work etc. including necessary form work complete all as specified and directed
S&F in repair harrison rails, mild steel, chromium plated with fixing brackets,stops,rollers etc with bracket etc.complete all as specified and as directed .
S & F in repair brass chromium plated bracket fancy type suitable for fixing to 20mm dia curtain rod complete all as specified and as directed .
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the all rubbish off from the premises complete all as specified and directed.
Demolition of plain cement concrete(un-reinforced) in ground floors, terrazo tiles floor & paving not exceeding 15cm thickness (below or above ground level) and removal of rubbish off from site complete all as directed by Engineer-in-Charge.
M & L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust,etc.complete with & including brushing neat cement slurry (@ 3 Kg of cement per Sqm) for bonding of old concrete surface to new concrete, complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 18mm -20 mm thick of size not less than 575 mm X 575 mm, over laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing & polishing over & including 20 mm thick screed bed in CM (1:6) complete all as specifed & directed.
M & L for machine cut kota stone slab flooring 18mm -20 mm thick over & including 20mm thick screed bed in cement mortar (1:4) as in step tread in one piece in one step,laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
M&L for machine cut 16-18mm thick white Marble stone flooring as in border,etc at kota stone flooring , laid over 20mm thick screed base in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing & polishing complete all as specifed & directed.
M&L for machine cut kota stone slab in skirtings,riser of steps ,dado & pillar 10 to 12 mm thick laid and jointed with grey cement slurry pointed with cloured cement to match the shade of the slab including grinding rubbing & polishing over 10 mm thick backing coat in CM (1:4) etc complete all as specifed & directed.
M & L glazed ceramic coloured tiles of size 375 mm x 250 mm x7mm/450 mm x 300 mm x7 mm thick ,as in dado/skirting etc ,set and jointed in neat cement slurry and pointed in colour cement to match the tiles over & including 10 mm thick rendering in cement plaster in CM (1:4) complete all as specified and directed.
M&L for joint free non skid coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc over & including 15mm thick screed bed in CM 1:4, set & jointed in neat cement slurry and pointed with white or coloured cement to match complete
M&L for joint free non skid coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in, skirting, dado, etc incl 10mm thick rendering in CM 1:4, set & jointed in neat cement slurry and pointed with white or coloured cement to match complete
M & L for 75 mm thick plain cement concrete (1:3:6) mix, type C-1 (using 20mm graded crushed stone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 75mm deep joints made at 3.00 m in length and filled with bitumen 85/25 grade and sand in the ratio 1:3 including necessary form work , complete all as specified and directed.
M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in kerb/benching/copings/window cill etc. including weathering,slightly rounded or chamfered angle and throating including use & waste of necessary form work etc complete all as specified and directed
M & L for rendering 5 mm thick in CM 1:4 on concrete surfaces as in ceiling finished even and fair complete all as specified and directed.
Demolition of cement concrete reinforced as in chullah hoods, shelves, cover slab and platform, etc,complete all as directed by Engineer-in-Charge
M&L for precast reinforced cement concrete 1:2:4 ,type B-1 (using 20 mm graded crushed stone aggregate) as in kitchen platform, shelves , cover slab, etc. including necessary formwork complete all as specified and directed. Note : Reinforcement will be measured & paid seperately under respective item of BOQ.
M&L for machine cut cudappah stone slab 20-25mm thick ,over & including 15 mm thick screed bed in CM (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including over laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing, polishing ,rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specifed & directed.
M & L for rounding of edges of Kota/Cuddapah stone slab one edge, such as in steps, cooking platform and other similar work, complete all as specified and as directed.
Taking up or down steel tubing and connections of 15 mm bore or removal to store complete etc and making good the surface in cement mortar 1:3 complete all as specified & directed.all as specified & directed.
Taking up or down steel tubing and connections of 20 mm bore or removal to store complete etc and making good the surface in cement mortar 1:3 complete all as specified & directed.all as specified & directed.
Taking up or down steel tubing and connections of 25 mm bore or removal to store complete etc and making good the surface in cement mortar 1:3 complete all as specified & directed.all as specified & directed.
S&F for GI water tubing medium grade, ISI marked, galvanised, 15 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chasees for brick walls and making good the surface in cement mortar 1:3 complete all as specified & directed.
S&F for GI water tubing medium grade, ISI marked, galvanised, 20 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls /laid in trenches and ceiling or laid in floors including cutting chasees for brick walls and making good the surfacein cement mortar 1:3 complete all as specified & directed.
S&F for GI water tubing medium grade, ISI marked, galvanised, 25 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls /laid in trenches and ceiling or laid in floors including cutting chasees for brick walls and making good the surfacein cement mortar 1:3 complete all as specified & directed.
Refixing for 15 mm bore old steel tubing and connections in new or old position (Walls, ceiling,floors, etc.)complete all as specified & directed.all as specified & directed.
Refixing for 20 mm bore old steel tubing and connections in new or old position (Walls, ceiling,floors, etc.)complete all as specified & directed.all as specified & directed.
Refixing for 25 mm bore old steel tubing and connections in new or old position (Walls, ceiling,floors, etc.)complete all as specified & directed.all as specified & directed.
S&F rotational moulded polythene water storage tank of capacity 500 ltrs (Cylindrical/vertical with closed type), triple layer construction, ISI marked, hoisted and fixed in position including 20 mm bore GI nipple and 20 mm bore ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms) including taking down of existing tank complete all as specified and directed.
S & F in repair PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including all standard accessories such as inlet ball valve float and handle, PVC flush pipe 32 mm bore & PVC connection 15 mm bore 450 mm long with PTMT nuts and brackets complete set & making good disturbed surface with CM 1:3 complete all as specified and directed.
S & F in repair for PVC connection pipe of 15 mm dia and 45 cm long to WHB and flushing cistern complete all as specified and directed.
S & F in repair angle stop valve /cock of 15mm bore, chromium plated with long shank and cup cast copper alloy, screwed down, high pressure, with crutch handle, screwed both ends for brass ferrule complete all as specified and directed.
S & F in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F in repair 15mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair bib taps , cast copper alloy with capstan head or butter fly handle,chromium plated screwed down with high pressure screwed for iron pipe and fixed 15 mm bore complete all as specified & directed.
S & F in repair, 15mm bore stop valve cast copper alloy, fancy type chromium plated with long shank and cup (concealed) screwed down,high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed.
S&F brass chromium plated shower rose with swivel joints, 125 mm size in square with CP long shank arm including fixing to steel pipe or union complete all as specifed & as directed.
S & F in repair vitreous China wash hand basin, flat back type, size 550X400mm including , 32 mm PVC waste pipe, chain & plug ,stopper, bracket ,cutting,pinnings in ends of brackets and making good disurbed surfaces in CM (1:3), complete all as specified and directed.
S&F vitreous China WC squatting pan " Orissa Pattern" of size 580 mm X 440 mm white with integral foot rest including cast iron "P" or "S" trap, front or back inlet and making connection to trap & to flushing cistern complete including taking down existing pan & making good disturbed surface complete all as specified & directed
S & F in repair pillar taps long body chromium plated, cast copper alloy with capstan head, chromium plated, screwed down with or without lettered 'Hot' or 'Cold' with long screw shanks and fly nuts, screwed for iron pipe and fixed for 15 mm bore complete all as specified & directed.
S & F in repair shelf of PTMT fixed with and including chromium plated brass screws and wooden/ plastic cleats (minimum weight 300 gms), complete all as specified and as directed.
S&F in repair towel rail brass chromium plated towel rail , 20 mm dia ,D-type 600 mm long between flanges fixed with and including chromium plated brass screw & wooden /plastic cleats complete set all as specified and directed.
Taking down cement plaster of brick or stone masonry etc including raking out joints , hacking for key & scrubbing down with water etc & removal of rubbish out off from site etc complete all as specified and directed.
Demolition of brick work of any description and in any position built in cement or cement lime mortar including all quoins, arches, pillars including segregation of serviceable bricks for reuse & removal of rubbish out off from site etc complete all as specified and directed.
M&L for Brick work with sub class bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 etc complete all as specified & directed.
M&L for rendering 15 mm thick on external surface of brick masonry/concrete surface etc in cement mortar (1:6) surface finished even & smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on brick masonry/concrete surface etc in CM (1:4) ,mixed with water proofing compound , trowelled to fair finished even & smooth without using extra cement complete all as specified and directed. (Note:Water proofing compound shall be measured and paid seprerately under respective item of "BoQ")
M&L for repair and rendering 10mm thick in cement mortar 1:3 on chajjas not exceeding 60cm width after removing cracked plaster and concrete surface including cleaning of visible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete 1:2:4 type B-O( using 12.5mm graded crushed stone aggregate )including necesssary scaffolding work for double/single storey building complete all as specified and directed.
S&F in repair for 110 mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed.
S&F in repair for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed.
S&F in repair 75 mm PVC(SWR) bends any radius complete all as specified and directed.
S&F in repair 110 mm PVC(SWR) bends any radius complete all as specified and directed.
S&F in repair 110 mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F in repair 75 mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F in repair 110 mm PVC (SWR) vent cowl complete all as specified and directed.
S&F in repair 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement with chromium plated grating with or without hole complete all as specified and directed.
S & F 110 mm dia PVC(SWR) WC connector with lip ring, complete all as directed and as specified.
M&L applying two coat of synthetic enamelled paint over a coat of pink primer on new wooden surfaces of any description not otherwise described, over 10cm width or girth including preparation of new wooden surface complete all as specified and directed
M&L for preparing the newly steel surface of any description not otherwise described, over 10 cm width or girth on steel surface and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
M & L for preparation of old treated surfaces of steel of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint on steel surface complete all as specified and directed.
M&L for applying three coats of white wash on newly plastered surfaces on wall after necessary preparation of the surface, complete all as specified and directed.
M & L for applying three coats of white wash on newly plastered surfaces of ceilings after necessary preparation of the surface, complete all as specified and directed.
M & L for preparation of old treated plastered surfaces of ceiling and applying one coat of white wash on ceiling complete all as specified and directed.
M&L for complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces with preparation of plastered surfaces including preparation of surfaces of walls and apply two coats of distemper oil emulsion (OBD) over a coat of primer (from same manufacturer of OBD) over a layer of wall care putty not less than 2mm thick etc complete all as specified and directed.
M & L preparation of old plastered surfaces of walls and applying one coat of oil bound distemper on walls, white or tinted applying by pump roller applicator complete all as specified & directed.
M&L for post construction anti termite treatment of soil under existing floors using emulsion @ one litre per hole,300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified & directed .
M&L for post construction anti termite treatment for treating along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified & directed .
M&L for applying two or more coats of 100 %premium acrylic emulsion paint having VOC less than 50gm/litr and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as specified & directed .
S&F mild steel deformed bars 8 to 10mm dia and over cut to length bend to shape required including cranking bending spirally for hooping for columns, hooking and binding with and including mils steel wire (annealed) not less than 0.9 mm dia quality conforming to Fe-410-S or F-410-0 etc all as spd.
Taking down eaves gutters and rainwater pipes (any size of pattern) including all fittings , heads , shoes , bnds , swanecks ,etc including removing from site .
Taking down carefully unserveciable/damaged copper/aluminium surface (batten/coduit or casing caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets ,light fittings etc) and removing material from site and making good to the disturbed surface to match with existing finish etc complete all as specified and directed.
M&L for following point wiring controlled by one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 1.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only) & 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steel sheet terminal box (normal & modular type) made out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including PVC board with bakelite sheet 2.8 mm thick laminated cover make sheet for housing/ fixing switches etc., including cutting holes for switches,sockets,regulators etc as per requirement including fixing with machine screw,washer etc complete all as specified and directed. Note: Proper colour coding to be adopted.
(a) One light point controlled by one , one way switch
(b) One fan point controlled by one, one way switch with Existing Conduit will be used
(c) One 3/5 pin socket outlet 5 amp on same board with other switches
(d) One 3/5 pin ,5 amp socket outlet on independent board
All as per Item No 113 above here with 2.5 Sqmm (Nominal Area) FRLSH cable PVC for the 15 Amp 3/5 pin socket power point including 2.5 Sqmm copper conductor green as color for earth continuity all as specified and directed.
M & L Sub main wiring with two runs of single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 6.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia/appropriate dia with accessories & fittings complete and making good disturbed surface wall including taking down existing sub main wiring complete all as specified and as directed. Note : - Two runs of 6.0 Sqmm cable and one run of earth wire 6.0 sqmm & conduit shall be measured as one unit length and extra length of cable required for connection to MCBs shall be deemed to be include in unit rate quoted by bidder.
S & F switch piano flush button single pole one way 5 Amp, complete all as specified and as directed.
S & F socket outlet 2 in 1, 3 pin, 5Amp/6 Amp, flush type, universal, complete all as specified & as directed
S & F ceiling rose three terminals PVC/ Polycarbonate, isolated body complete all as specified & as directed
S & F fan regulator electronic, step type hum free, socket type, suitable for ceiling fans of any capacity 230 Volts complete all as specified & as directed
S & F lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked), complete all as specified.
S&F in replacement 15 watt LED bulb PAG series B-22 base (ISI mark) ,three star rated lamp with all accessories complete all as specified and as directed.
S & F socket outlet 2 in 1, 3 pin, 5/16 Amp, flush type, universal, complete all as specified & as directed
S & F switch piano flush button single pole one way 15 Amp/16 Amp,240 volt complete all as specified and as directed.
S & F LED tube light fitting 1 x 20watt , 220 V, AC, decorative box type with driver ,holder including LED tube light surface and wall mounted LED batten PVC housing with polycarbonate diffuserand integrated electronic driver complete with all accessories ,driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified & as directed
S & F in repair LED mirror type light fittings 1 x 9/10 watts integral slim LED batten with high out put diffuser 2 feet long ,220 volt ,AC decorative type with driver holder & LED lamp & all other accessories duly pre wired and making connection with and including three core copper flexible wire from connector to ceiling rose not less than 1 mtr fixed on wall with plastic gutties complete all as specified & directed.
S&F for distribution board (DB) made out of steel sheet metal enclosure (CRCA sheet) dust and vermin proof Triple pole and neutral(TPN) 6 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar 415volts ,flush to wall including taking down carefully existing unserveciable /old main switches, DBS along with MCBs complete all as specified and directed.
S& F 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN/FP 40 amp to 100 amp and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
S & F in replacement of double door SPN distribution boards steel sheet powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 415 Volts suitable Amps rated busbar 8 way complete all as specified and directed.
S & F in replacement of double door SPN distribution boards steel sheet powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 415 Volts suitable Amps rated busbar 4 way complete all as specified and directed.
S & F miniature circuit breaker (MCB) SP 6 to 32 Amps ('B' Series) having current rating 10 KA,240 Volt in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
S & F miniature circuit breaker (MCB) double pole 40 Amps ('B' Series) ISI marked having current rating 10 KA,240 Volt in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
M&L for Earthing complete for poles/DBs with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below normal ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point,GI tubing 20mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel & wire mesh,charcoal dust and common salt 15cm in layers all round the earth plate, 40 mm thick pre-cast RCC cover (1:2:4) type B-1(using 20 mm graded crushed stone aggregate )reinforced with 8mm dia TMT bar @ 75mm c/c both way with mild steel handle 20mm dia round bar , plastering 15mm thick with CM (1:6:) internally and upto 150mm below ground level externally and chamber of (size of pit 300 mm x 300 mm x 300mm internal diamentions) PCC (1:3:6) type C-1(using 20 mm graded crushed stone aggregate ) (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m & returning filling) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I including taking down old/ unserveciable existing earthing & making good disturbed surface of wall ,floors etc.complete all as directed. Notes: -(i) Earth lead & protection pipes length upto & including 7.50 metre. (ii) Earth filling shall be done by vegetable soil. (iii) Soil should be free from stone, boulders, aggregate, gravels etc.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 35 Sqmm 3.5 core including taking down of existing unserveciable/old cable complete all as specified and directed.
S & F in repair 40 mm bore GI tube, light grade with all fitting for cable protection including clamp ,nut,bolts & washer etc complete all as specified and as directed.
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated soil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Supply and spreading clean, dry, fine river sand for under ground electric cable in two layers (8cm thick before laying of cable & 15cm thick after laying cable to a total of 23cm) including gentle punning the sand upto 18cm (total thickness) and consolidated around cable for protection of UG cable complete all as specified and directed. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I.
Supplying & Laying factory made un-reinforced pre-cast flat concrete cable protection cover of class LV , type- I, size 250 mm x 150mm x 40mm, complete all as specified and directed by the Engineer-in-Charge.
S & F building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaries with high power LEDs as light source & exclusively designed polycarbonate cover along with electronic driver type street light fitting 35/36 watt capacity LED and including all necessary accessories duly pre-wired, fixing on bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete including taking down old / unserveciable security lights any type and description complete all as specified and directed.
S & F in repair bracket made out of 40 mm dia GI pipe light grade 1.20 mtr long bend to shape as per site requirement fixed to pole /wall with 40mm x 5 mm size flat iron clamp -02 Nos,nuts & bolt of 12 mm dia 100 mm long with washer etc duly painted applying two coats of synthetic enamel paint over a coat of red oxide primer on mild steel exposed surface including prepartion of new or previously untreated steel surface of any description,not otherwise described over 10 cm in width or girth complete all as specified & directed.
S & F in repair 1X9 W/1X10 W watt LED Bulkhead fitting with IP 65 environmental frendly, ultra modern, energy saving mounted decorative oval bulk head edge lit LED luminaire comprising of high brightness LED 230 Volts AC circuit connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed .
Taking down ceiling fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M Ramgarh complete all as specified and as directed.
Refixing ceiling fan after rewinding of ceiling fans of various makes of size 1200 mm /1400 mm sweep from working on 230/250 volt single phase AC supply and re-winding with supper enamelled new copper wire of appropriate gauge including varnishing with good quality varnish' baking up, reassembling the fan, testing including replacement of connector and repair/ replacement of bearing, flexible wire of size 23/0.0040 three core up to one metre complete all as specified and as directed.Note : Cutting of winding coil of exhaust fans shall only be done in presence of Engineer-in-charge.
Refixing of ceiling fan after Servicing ceiling fans of 1200mm sweep for repairing / overhauling by cleaning/greasing/oiling etc and repairing of nearng , reassembling the same complete all as directed by Engineer-in-Charge.
Taking down exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan for repair and cutting of existing winding of exhaust fans of 300 mm /450 mm sweep and rewinding with same/suitable size super enamelled copper winding wire and including insulating the same with super enamelled varnish,bush/bearing and painting one coat of synthetic enamelled paint after preparation of old surface and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of exhaust fans shall only be done in presence of Engineer-in-charge.
Boring of hole under road, pavement, hard standing without disturbing existing surface by trenchless technology using ultra sound technique and necessary machine complete all as specified and directed by Engineer-in-Charge. Note : Pipes shall be laid minimum 1.00 mtr below/under existing road surfaces/taxi track / apron /floors etc.complete all as specified and as directed.
S & F in repair for High density polyethylene (HDPE) pipe of 40 mm dia sutable for 6 Kgf / sq.cm working pressure complete all as specified and directed by Engineer-in-Charge.
S & F in repair for High density polyethylene (HDPE) pipe of 20 mm dia sutable for 6 Kgf / sq.cm working pressure complete all as specified and directed by Engineer-in-Charge.
S & F Inverter LED bulb of capacity 12 Watts lumes output (1200) length 140 mm width 70mm base cap B22 ,3 Star ,(ISI Marked) complete all as specified and directed by Engineer in Charge.
M/S KAMLESHWAR SINGH
simplex infra project
M/s friend enterprises
JP ENTERPRISES
M/S Parmar Construction
M/S PARAS NATH SINGH
SHUBHAM CONSTRUCTION COMPANY
SARKAR BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .