Loading…
Loading…
Tender Value
₹2.6 Cr
EMD Value
₹5.2 L
Closing Date
9 Jul 2026, 3:00 pmClosed
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SNT TENDER
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of 'V/N' or 'V' whichever is less; where, V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Similar Nature of Work :- Any RI or EI or CLS or ABS or IBS work involving indoor & outdoor work (cable laying & termination).
6 conditions · 2 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Checklist for Tenderer: The Tenderer shall submit signed copy of Check-list placed in documents attached with tender. The Tenderer shall also submit relevant documents of compliance of the checklist if any.
While bidding, bidder should submit the MOU of RDSO approved source (OEM or his RDSO approved source) of existing MEDHA make EI at the time of bidding covering supply of the equipment of EI, installation, alteration, testing and commissioning of EI including after sales support required during the warranty period and beyond the warranty period, failing which tender/offer shall be summarily rejected.
Bhavnagar Division: Supply installation, Testing, Commissioning of Signalling gears and alteration in Medha make Electronics Interlocking system in connection of Bhimnath- Provision of Additional Loop Line.
DRMSnT-BVP-Sig11of26-27
DRMSnT-BVP-Sig11of26-27
Open
Works - General
12 Months
Bhavnagar, Gujarat
₹0
₹5.2 L
9 Jul 2026
17 Jun 2026
25 Jun 2026
286 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | Above/ Below/Par | ||
| — | — | — | 1,24,33,366.44 | ||
| — | 4.00 | — | — | ||
| Supply of IOCOM CPU CARD of Medha make EI system. | — | — | — | 3,37,376 | |
| — | 4.00 | — | — | ||
| IOCOM VOLTAGE AND HEALTH MONITORING CARD of Medha make EI system. | — | — | — | 1,32,016 | |
| — | 6.00 | — | — | ||
| INPUT WFM CPU CARD of Medha make EI system. | — | — | — | 2,60,838 | |
| — | 4.00 | — | — | ||
| OUTPUT WFM CPU CARD of Medha make EI system. | — | — | — | 2,14,004 | |
| — | 4.00 | — | — | ||
| WFM RELAY DRIVER CARD of Medha make EI system. | — | — | — | 1,45,532 | |
| — | 2.00 | — | — | ||
| OCM VITAL CUT-OFF CARD of Medha make EI system. | — | — | — | 1,18,002 | |
| — | 4.00 | — | — | ||
| POWER SUPPLY CARD TYPE B of Medha make EI system. | — | — | — | 1,03,212 | |
| — | 4.00 | — | — | ||
| POWER SUPPLY CARD TYPE C of Medha make EI system. | — | — | — | 1,78,652 | |
| — | 6.00 | — | — | ||
| SINGLE MODE RS485-OFC BI-DIR. CONVERTER of Medha make EI system. | — | — | — | 6,61,146 | |
| — | 10.00 | — | — | ||
| 24V EMI FILTER of Medha make EI system. | — | — | — | 1,13,600 | |
| — | 2.00 | — | — | ||
| OC Card files, Enclosure with mounting arrangement, Consisting of OC TOP & BOTTOM BACK PLANES (Two object controllers are accommodated in single enclosure) of Medha make EI system. | — | — | — | 6,79,740 | |
| — | 2.00 | — | — | ||
| Supply of Relay Racks and Wiring accessories of Medha make EI system. | — | — | — | 17,50,000 | |
| — | 6.00 | — | — | ||
| Supply of DC-DC Converters of Medha make EI system. | — | — | — | 2,10,000 | |
| — | 1.00 | — | — | ||
| Supply of Remote Craft Terminal as per specification Intel i5, 15.6-inch, preloaded windows10 OR higher, RAM 8 GB DDR4 expandable upto 32GB, SSD 512 GB, Wifi, Bluetooth, with 3 years Onsite OEM warranty of Dell, Lenovo, HP Make. Prior approval to be taken before supply for make and specification. | — | — | — | 75,762.36 | |
| — | 100.00 | — | — | ||
| Rubber Mat for Power Equipment room. (5mm thick). | — | — | — | 11,004 | |
| — | 10.00 | — | — | ||
| Relay QNA1, AC immunized,08F/08B, 12F-4B, 24VDCalong with plug board, retaining clip and connectors conforming to BRS: 931A, IRS: S60, IRS: S34 & IRS: S24. | — | — | — | 57,789.4 | |
| — | 1.00 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq. mm. (85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest. | — | — | — | 44,446.73 | |
| — | 1.00 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest. | — | — | — | 1,23,096.69 | |
| — | 1.00 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductor's cross section 25 Sq. mm (0.4x196) as per specn. IS 694/2010 with latest amendment, and test parameters as per IRS(S) 76/89. | — | — | — | 1,19,877.38 | |
| — | 10.00 | — | — | ||
| Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest. | — | — | — | 64,783.4 | |
| — | 5.00 | — | — | ||
| Extinguisher CO2 type (capacity 4.5 kg. or above). | — | — | — | 40,255.55 | |
| Module | 2.00 Each | — | — | ||
| Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 32 nos. of external Non-Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in signaling circuits. The system shall have 8 cards with a monitoring arrangement of 4 fuses in one card. | — | — | — | 68,664 | |
| Module | 1.00 Each | — | — | ||
| Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 24 nos. of external Non-Deteriorating Type or 'G' type fuses from 4 Amp to 10 Amp capacities which are in signaling circuits. The system shall have 6 cards with a monitoring arrangement of 4 fuses in one card. | — | — | — | 58,494.08 | |
| — | 300.00 | — | — | ||
| Indicative type Fuse suitable to G type fuse base/holder of capacity 0.63 A - 3.0 A. (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 7,761 | |
| — | 100.00 | — | — | ||
| Indicative type Fuse base/ holder with cap, suitable to G type fuse of capacity 0.63A - 3.0A. (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 7,217 | |
| — | 50.00 | — | — | ||
| Indicative type Fuse Without holder 6A (System, Rapid or Malnad or RBCO make or similar) as per IRS: S-80/92. | — | — | — | 1,722 | |
| — | 50.00 | — | — | ||
| Round head type non deteriorating type low voltage cartridge fuse as per Spec No IRS/S/78/92 with latest amendments 2A/4A/6A capacity. | — | — | — | 2,860.5 | |
| — | 8.00 | — | — | ||
| Miniature, Plug in Type, M to C, DC Neutral, Track relay, ACI, Style QTA2, 9 Ohm, 2F-1B contact, Code - FGHKX Spec: BRS :939-A & 966 (Appx-F2) & IRS: S-23, S-23, S-34 & 60. | — | — | — | 49,399.44 | |
| — | 8.00 | — | — | ||
| Miniature, Plug in Type, DC Neutral, Line Relay QSPA1, 24V DC, Slow to Pick up AC Immunized, 12F- 4B/8F-4B Contact, Code ABDEJ Spec: BRS:933A; IRS S 34; IRS S 23; IRS S 60-78. | — | — | — | 53,978.4 | |
| — | 8.00 | — | — | ||
| Track feed battery chargers, 110V AC input, 2 to 6/10 V DC Output; as per Specn. No. IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery. | — | — | — | 32,117.92 | |
| — | 8.00 | — | — | ||
| Adjustable Track Feed Resistance disc type 30 ohms as per RDSO Drg. No. SA 20166/M (Adv.) with latest amendments (with Phenolic molded base). | — | — | — | 8,731.36 | |
| — | 30.00 | — | — | ||
| Track Lead Junction Boxes as per C. Rly Drg. No. RST 11509 made from fibre glass/SMC/FRP along with terminal blocks. | — | — | — | 37,326.3 | |
| — | 2000.00 | — | — | ||
| GI wire 8 SWG (4mm Dia) suitable for track circuit rail bonding. | — | — | — | 1,67,840 | |
| — | 500.00 | — | — | ||
| Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm Dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M. | — | — | — | 2,730 | |
| — | 15.00 | — | — | ||
| Point insulation Complete set as per RDSO Specification IRS: S-40/84 for Switch bracket, Split- Stretcher bar & Gauge tie plates (52 Kg/60Kg as per site requirement). | — | — | — | 26,208.75 | |
| — | 4.00 | — | — | ||
| Key Lock Relay working on 24V DC, AC immunize with different ward combinations (Three ward plates to be supplied with each relay). Key ward shall be specified by engineer in charge as per requirement. | — | — | — | 40,178.8 | |
| — | 10.00 | — | — | ||
| Apparatus Case Single NE Rly Type as per Drg. No. W. Rly/SW/47/68 Alt-A, fitted with two no.s of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377 Note: This item includes the supply & fixing of 2 No.s E Type Lock fitted on both doors, along with two Keys. | — | — | — | 1,98,897.4 | |
| — | 5.00 | — | — | ||
| Apparatus Case half NE Rly Type as per Drg. No. W. Rly/SW/47/68 Alt-A fitted two no.s E Type lock of (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377. Note: This item includes the supply & fixing of 2 No.s E Type Lock fitted on both doors, along with two Keys. | — | — | — | 73,851.85 | |
| — | 15.00 | — | — | ||
| IS 13410: Glass Reinforced Polyester Sheet Moulding Compounds (SMC) Size of Sheet: 1000x1000x8. | — | — | — | 79,807.5 | |
| — | 50.00 | — | — | ||
| Supply of 4 connection points single potential through screw less terminal block for 6 Sq.mm - 35 Sq.mm, 4 connection points 284-621/624 or superior, suitable for power cable connection. | — | — | — | 12,251.5 | |
| — | 1000.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Note: Make to be approved by Railway before supply. | — | — | — | 52,950 | |
| — | 20.00 | — | — | ||
| Supply of End plate 2.5mm/0.091 in thick as per site requirement. | — | — | — | 200.4 | |
| — | 20.00 | — | — | ||
| Supply of End Stopper 10mm/0.0394 in width as per site requirement. | — | — | — | 196.6 | |
| — | 10.00 | — | — | ||
| Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. | — | — | — | 1,030.3 | |
| — | 3000.00 | — | — | ||
| ARA Terminal blocks with links made of PBT Spec Nos/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. | — | — | — | 2,74,050 | |
| — | 25.00 | — | — | ||
| Magneto telephone with generator as per RDSO specification No. IRS:TC 36/97 amendment 1 weight per unit 2 kg. | — | — | — | 1,29,564 | |
| — | 2000.00 | — | — | ||
| Supply Polyolefin cable channel of size width 240/340 mm, height 155/230 internal/external, length 1 meter produced of polyolefin with fire protection class K-1 in accordance with DIN 53438 Part-II for laying signaling/telecom cables, channel attachable to each other with male female swallow tail connectors and having a suitable detachable cover, as per RDSO STS/E/cable laying Precise Vol-IV and as per technical specifications. | — | — | — | 39,41,100 | |
| — | 100.00 | — | — | ||
| Supply and fixing of polyolefin cable channel (Injection Moulded Plastic cable Duct) of size width 100/200 mm, height 155/230 internal/external, length 1 meter produced of polyolefin with fire, protection class K-1 in accordance with DIN 53438 part all for laying signaling/telecom cables, channel attachable to each other with male female swallowtail connectors and having suitable detachable cover including supply of all fixing materials like Brackets, etc. , as per RDSO STS/E/cable laying Precise Vol-IV and as per technical specifications. | — | — | — | 1,90,008 | |
| — | 500.00 | — | — | ||
| Supply of Half Round RCC pipes & collars of 300 mm outer dia & 250 mm internal dia (1 meter long) along with collars with material strength as per IS No. 458/2003 of NP type. | — | — | — | 1,79,675 | |
| — | 25.00 | — | — | ||
| Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 120 mm outer die, & 103.5 mm inner dia. One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Color -Bright Orange; Min Weight = 4kg. Test Check by Consignee & Sample check by JAG officer. | — | — | — | 54,824.25 | |
| — | 7.00 | — | — | ||
| Colour Light Signal Complete. This includes: - (1). Post Tubular 140 mm Dia, as per IRS: S-6/81 or Latest & RDSO Drg. No. SA- 24625 (Advance). (2). CI Base (As per IRS S-10 & RDSO Drg. No. 2011/M with latest assembly). (3). Pinnacle. (4).Ladder Assembly, as per RDSO Drg. No. SA-23156, with Base, Ladder Guards, Platform, Front Maintenance Platform, MS Supporting bracket to Support Ladder. (5). Signal Front Staging Complete Assembly for CLS Unit. (6). Signal back staging as per extent WR Practice. Note: Height of the Post shall be 5.5 Long. | — | — | — | 1,02,233.46 | |
| — | 5.00 | — | — | ||
| Non Metallic (FRP) color light signal housing multi-unit type for railway signaling suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | — | — | — | 1,49,575.8 | |
| — | 4.00 | — | — | ||
| Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23002/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol.1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | — | — | — | 1,24,878.68 | |
| — | 2.00 | — | — | ||
| Junction route indicator unit 2 way as per Drg. No. RDSO SA 23402 is suitable for LED Signal Lighting Units & as IRS: S-66/84 amndt-1 or latest. | — | — | — | 37,980.68 | |
| — | 1.00 | — | — | ||
| — | 16.00 | — | — | ||
| Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197with latest Amd. | — | — | — | 1,80,339.04 | |
| — | 40.00 | — | — | ||
| Earth Electrode as per Drg. No. CSTE / 6091. | — | — | — | 1,10,543.2 | |
| — | 500.00 | — | — | ||
| Supply of copper strip for earthing (25mm x 3mm). | — | — | — | 3,06,640 | |
| — | 1000.00 | — | — | ||
| Supply of GI flat for earth (50 X 6 mm). | — | — | — | 2,21,140 | |
| — | — | — | Above/ Below/Par | ||
| — | — | — | 1,01,82,474.25 | ||
| — | 1.00 | — | — | ||
| Modification of EI System of Medha at BHIMNATH Station of WR, as per RDSO spec no: RDSO/SPN/192/2019. Modification to the existing Application Logic circuits and Interface circuits. Alteration to the MT and VDU software. Up-gradation of Data-logger database at MEDHA end. FAT (Factory Acceptance Test), SAT and commissioning as per the Modified Application Logic. ASMADES | — | — | — | 52,75,000 | |
| — | 2.00 | — | — | ||
| Supply, Installation and Commissioning of EI VDU (Visual Display Unit, 4K with all suitable accessories Compatible to El Interlocking in Safe Mode 24x7 at controlling station. The item must comply minimum following specification:- a) Screen Size (Diagonal):- As below b) Resolution :- 4K c) Viewing angle degree: - 178x178 degree d) Brightness :- 500 Nits e) contrast ratio 4000:1 f) Backlit :- Direct LED g) Jack Interface: - HDMI -3 no. 1.2 DP, DVI USB 2.0 -2 no. CI Slot RF In AV In Component In (RCA5 Type) Digital Audio Out RGB In (D-sub 15pin)-PC PC Audio Input RS232C (D-Sub 9pin) RJ45 Stereo mini jack. h) Optical Out :- Available Note: - Screen size will be decided as per instruction of engineer in charge. Approximate Screen size 55 inch. | — | — | — | 1,56,760.98 | |
| — | 2.00 | — | — | ||
| Supply and Installation of Modular power supply arrangement for VDU and industrial PC (Embedded PC) with input and output redundancy arrangement and Hot pluggable Modules as per RDSO specification. Make Gallant or similar. One set consists of 1. Input O- ring diode module with potential free -1 No contacts (PFC) for two 110 V DC sources from IPS and single 110 VDC bus Qty 1 No. 2. Isolated Inverters (Master / slave) - Input-110 V DC Output: 120 V AC/220V A500VA - 02 Nos. 3. Isolated DC-DC convertors- Input: 110 v DC Output: 24 V DC/ 10A, Qty - 10 Nos 4. 3 U SS rack with back panel mother board /front panel power connectors inverter auto change over switch and all required over switch and all required protection circuits (3U height for main rack 132.5mm +/-10% & 1U height for mounting 44.5mm +/- 10%) Qty - 1 No. Make Gallant or similar. | — | — | — | 5,45,724 | |
| — | 2.00 | — | — | ||
| Supply & installation of Industrial Grade Embedded PC as per RDSO TAN no. STS/E/TAN/3007 dated 2.11.12 or latest. Prior approval to be taken before supply. | — | — | — | 3,24,533.98 | |
| — | 24.00 | — | — | ||
| Additional Functional testing (SAT) of PI/RRI/IBS /Auto signal etc. as per Selection table, control table etc. Contractor shall depute one Engineer, one Supervisor & wiremen technically qualified to carry out functional testing as per approved design. Technical knowledge of contractor's staff will be judged by Railways Engineer incharge before permitting them to do the testing. Contractor has to note down all the discrepancies found in testing noted during functional test in a separate design register and to be counter signed by Railways representative. Rectification of circuit discrepancies to be done after taking approval of changes in circuit diagrams by Railways. Mistakes found to be rectified free of cost by contractor. Omission in testing or wrong testing found after functional test will be penalized @ 5% pf rate per route. | — | — | — | 8,333.04 | |
| — | 1.00 | — | — | ||
| Earthing of EI equipment, relay racks and Power equipment etc. to be done along with the supply of all requisite materials. Earthing shall be in the form of Ring Earth conforming to RDSO specification No. RDSO/SPN/197/2008 (with a min. of 6 maintenance free earth electrodes) & RDSO Drawing issued under Railway Board letter No. 2010/Sig./SGF/EI (Ansaldo) Dated 22.06.11, made using copper rings with earth resistance less than 1 ohm. The earthing shall be maintenance free & earth enhancement compound should be used. The ring earth shall be connected to copper flat of size 25x3 mm in the relay room and IPS room. This copper flat shall be fixed on the wall to the entire breadth of the Relay room and IPS room as an earth bus bar and all earth connections shall be taken from it. A, B, C, & D class protection shall be provided for all EI equipment. Note: - This will also cover the earthing& necessary protection of EI equipment as per details given in the scope of work of Special Condition of Contract and other requirement given in Chapter of tender document & Pre-commissioning check list of EI system. | — | — | — | 1,20,568.88 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-2022-uptoACS10_merged_compressed.pdf
ATTACHMENT
SignedJPOBVPDivisionforundertakingdiggingworkinthevicinityofSTandElectricalcablesmerged._1.pdf
ATTACHMENT
CHECKLISTFORTENDERERmorethan50Lacs.pdf
ATTACHMENT
GCCACS11Merged_compressed.pdf
ATTACHMENT
TenderConditionandScheduleofworkBNH.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .